Plan Review Details - Permit 16081018
Plan Review Stops For Permit 16081018
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2016-10-17 Cont ID  
Sent By skennedy Date 2016-10-17 Time 14:24 Rev Time 0.00
Received By skennedy Date 2016-10-17 Time 14:24 Sent To  
Notes
2016-10-17 15:05:481ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL
  
  
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  
2016-09-12 15:35:23ADJUSTED VALUE TO $60,000.00 PER EMAIL FROM APPLICANT
 SEE NOTES.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-10-17 Cont ID  
Sent By skennedy Date 2016-10-17 Time 15:06 Rev Time 0.00
Received By skennedy Date 2016-10-17 Time 15:05 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-09-12 Cont ID  
Sent By mvaldes Date 2016-09-12 Time 12:08 Rev Time 0.00
Received By mvaldes Date 2016-09-12 Time 10:38 Sent To  
Notes
2016-09-12 12:10:55JOB PERMIT NUMBER: 16081018
 JOB ADDRESS: 1105 21 STREET
 WEST PALM BEACH FLORIDA
 DATE: SEPTEMBER 12, 2016
  ELECTRICAL PLAN REVIEW COMMENTS
  
 THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION
 HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF
 THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC,
 (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST
 PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF
 SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED.
  
 1] PLEASE CLEARLY DEFINE THE EXTENT OF THE ELECTRICAL
 SCOPE OF WORK. FURTHER COMMENTS MAY BE ADDED TO ENSURE
 A SAFE CODE COMPLIANT DOCUMENT IS PASSED. FBC 107
 MINIMUM PLAN REVIEW
  
 2] ELECTRICAL LOAD CALCS DON'T REFLECT PROPER DEMANDS
 IN ACCORDANCE WITH NEC 220.82(A)&(B) OPTIONAL METHOD.
 MISSING 2 SMALL APPLIANCE, DISHWASHER, MICROWAVE, HOOD,
 AND FYI THE RECEPTACLE LOAD IS INCLUDED IN THE 3VA PER
 SQFT GENERAL LIGHTING DEMAND. UNLESS 4 SEPARATELY
 CONTROLLED UNITS THE AC HEAT LOADS CANNOT BE DEMANDED
 AT 40 % PLEASE VERIFY NEC 220.82(C). CORRECT PANEL
 SCHEDULES TO MATCH CURRENT LOADS AND ADJUST
 CALCULATIONS ACCORDINGLY.
  
 3] SMOKE ALARMS SHALL BE 3' AWAY FROM AC AND BATHROOMS
 PLUS BE PROTECTED BY AN ARC-FAULT BREAKER PER NFPA 29 &
 FBC-R SECTION E3902.13
  
 4] ALL NEWLY INSTALLED RECEPTACLES SHALL BE
 TAMPER-RESISTANT. FBC-R SECTION E4002.12
  
 5] ALL NEWLY INSTALLED LIGHTING SHALL BE 75 % HIGH
 EFFICIENCY AND RECESSED FIXTURES WILL BE IC-RATED
 SEALED TO NOT COMPROMISE BUILDING THERMAL ENVELOPE.
 FBC-E SECTIONS R402.4.4 & R404.1
  
 PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE
 MENTIONED DEFICIENCIES.WHEN RESUBMITTING, FOR A QUICKER
 RETURN ON YOUR RE-SUBMITTAL, PROVIDE A RESPONSE LETTER
 (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE
 STANDARD CITY RE-SUBMITTAL FORM.
 CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED. IF
 YOU HAVE FURTHER QUESTIONS, PLEASE DON'T HESITATE TO
 CONTACT ME DIRECTLY.
  
 FBC 2014 5TH ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-10-21 Cont ID  
Sent By lmarchan Date 2016-10-21 Time 13:05 Rev Time 0.00
Received By lmarchan Date 2016-10-18 Time 10:46 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-10-17 Cont ID  
Sent By skennedy Date 2016-10-17 Time 15:06 Rev Time 0.00
Received By skennedy Date 2016-09-02 Time 10:08 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2016-10-17 Cont ID  
Sent By skennedy Date 2016-10-17 Time 14:23 Rev Time 0.00
Received By skennedy Date 2016-09-12 Time 15:39 Sent To  
Notes
2016-10-17 14:23:55THERE ARE NO DETAILS PROVIDED FOR MECHANICAL WORK.

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-10-17 Cont ID  
Sent By skennedy Date 2016-10-17 Time 14:23 Rev Time 0.00
Received By skennedy Date 2016-09-12 Time 15:38 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2016-10-17 Cont ID  
Sent By skennedy Date 2016-10-17 Time 14:21 Rev Time 0.00
Received By skennedy Date 2016-10-17 Time 14:21 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2016-10-17 Cont ID  
Sent By skennedy Date 2016-10-17 Time 15:06 Rev Time 0.00
Received By skennedy Date 2016-10-17 Time 15:06 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2016-10-21 Cont ID  
Sent By njwira Date 2016-10-21 Time 12:03 Rev Time 0.00
Received By njwira Date 2016-10-21 Time 12:03 Sent To I
Notes
2016-10-21 12:03:5210/21/16- PASSED
  
 SF-14
  
 MEETS REAR SETBACK
  
 PLEASE CONTACT
 NATHAN WIRA
 [email protected]
 (561)822-1442
  

Review Stop Z ZONING
Rev No 1 Status F Date 2016-09-20 Cont ID  
Sent By nwira Date 2016-09-20 Time 09:18 Rev Time 0.00
Received By njwira Date 2016-09-20 Time 09:22 Sent To I
Notes
2016-09-20 09:22:219/20/16- FAILED
  
 SF-14 SINGLE FAMILY LOW DENSITY RESIDENTIAL
  
 FAILED
 1. WHAT IS THE REAR SETBACK?
  
 PASSED
 1. FRONT SETBACK IS 27FT. AND MEETS THE 25FT. SETBACK
 REQUIREMENT
 2. SIDE SETBACK IS 21FT. TOTAL 10FT. MINIMUM MEETING
 THE 5FT. MINIMUM 15FT. TOTAL.
 3. NO TREES BEING REMOVED
 4. ELEVATION IS 23.75 MEETING THE 30FT. MAXIMUM
 ELEVATION
 5. FENCE IS 6FT. HIGH IN THE BACK 4FT. IN THE FRONT
 MEETING THE 6FT. IN THE REAR 4FT. IN THE FRONT MAXIMUM
 HEIGHT FOR A FENCE.
 6. WOOD FENCE IS PERMITTED IN THIS ZONE.
 7. NOT ON A CORNER LOT.
  
 PLEASE CONTACT
 NATHAN WIRA
 [email protected]
 (561)822-1442
  