Plan Review Stops For Permit 16080974 |
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2016-12-30 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-12-30 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-12-30 |
Time |
12:58 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2016-11-21 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-11-21 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-11-21 |
Time |
16:32 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2016-09-16 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-09-16 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-09-16 |
Time |
12:14 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2016-08-29 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-08-29 |
Time |
:02 |
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-08-29 |
Time |
16:02 |
Sent To |
M |
|
Notes |
2016-08-29 16:04:53 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | INSPECTION. | | | | | | 1) THE APPROVAL OF ANY SUPPRESSION SYSTEM IS NOT | | INCLUDED NOR APPROVED WITH THIS PERMIT. | | | | ANY PROPOSED SUPPRESSION SYSTEM SHALL BE SUBMITTED | | UNDER SEPARATE SHOP DRAWINGS. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2017-01-13 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-01-13 |
Time |
07:32 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-01-11 |
Time |
14:27 |
Sent To |
|
|
Notes |
2017-01-11 14:27:57 | RESUB ROUTED TO CCOLE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2017-01-03 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-01-03 |
Time |
09:06 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-12-28 |
Time |
09:22 |
Sent To |
|
|
Notes |
2016-12-29 09:22:58 | RESUB ROUTED TO FIRE INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2016-11-29 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-11-29 |
Time |
11:53 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-11-17 |
Time |
11:18 |
Sent To |
|
|
Notes |
2016-11-18 11:18:46 | RESUB ROUTED TO FIRE INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-11-04 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-11-04 |
Time |
12:53 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-11-02 |
Time |
12:53 |
Sent To |
|
|
Notes |
2016-11-03 12:54:01 | RESUB ROUTED TO CCOLE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-09-19 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-09-19 |
Time |
12:37 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-09-09 |
Time |
10:46 |
Sent To |
|
|
Notes |
2016-09-12 10:46:23 | RESUB ROUTED TO FIRE INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-09-12 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2016-09-02 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2016-08-23 |
Time |
14:30 |
Sent To |
|
|
Notes |
2016-08-23 14:30:45 | ROUTED TO FIRE INBOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
6 |
Status |
P |
Date |
2017-01-13 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-01-13 |
Time |
07:32 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-01-13 |
Time |
07:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
F |
Date |
2017-01-03 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-01-03 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-01-03 |
Time |
09:06 |
Sent To |
|
|
Notes |
2017-01-03 10:33:30 | 5TH REVIEW FBC-2014 MECHANICAL | | PERMIT #16080974 | | 1/3/17 | | | | 1) COMMENTS FROM THE PREVIOUS REVIEWS REGARDING MAKEUP | | TEMPERATURE STILL EXISTS. IF CHOOSING TO SHOW THAT THE | | EXISTING OR PROPOSED AC SYSTEM HAS THE CAPACITY TO | | ACCOMODATE THE ADDITIONAL HEAT GAIN FROM THE MAKEUP | | AIR, PLEASE PROVIDE AN EQUIPMENT SCHEDULE FOR THE | | SYSTEM AND A LOAD CALCULATION FOR THE SPACE THAT | | INCLUDES THE ADDITIONAL HEAT LOAD. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
F |
Date |
2016-11-29 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-11-29 |
Time |
11:53 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-11-29 |
Time |
11:53 |
Sent To |
|
|
Notes |
2016-11-29 11:56:12 | 2ND REVIEW FBC-2014 MECHANICAL | | PERMIT #16080974 | | 11/29/16 | | | | 1) COMMENT #1 FROM THE 1ST REVIEW STILL EXISTS. I HAVE | | REPRINTED BELOW. | | | | 1ST REVIEW COMMENT #1: IF CHOOSING NOT TO PROVIDE | | CONDITIONED MAKEUP AIR, PLEASE PROVIDE AN AC | | CALCULATION THAT INCORPORATES THE ADDITIONAL HEAT LOAD | | FROM THE MAKEUP AIR. THE CALCULATION MUST INDICATE THAT | | THE EXISTING SYSTEM CAN HANDLE THE ADDITINAL LOAD. | | PLEASE SEE SECTION R302.1 FBC-14 ENERGY CONSERVATION | | FOR INTERIOR DESIGN TEMPERATURE (75 DEGREES F FOR | | COOLING). | | | | THE SUBMITTED CALCULATION INDICATES AN INTERIOR DESIGN | | DRYBULB TEMPERATURE OF 75 DEGREES. THE ENGINEER HAS | | WRITTEN IN HIS REPONSE NARRATIVE THAT THE TEMPERATURE | | WILL BE SET AT 81 DEGREES IN THE KITCHEN AREA, HOWEVER | | THERE IS ONE AC SYSTEM THAT IS PROVIDING COOLING TO | | BOTH THE DINING AND KITCHEN AREAS. PROVIDE EVIDENCE ON | | THE PLAN THAT THE INTERIOR DESIGN TEMPERATURE IN THE | | | | KITCHEN WILL BE 81 DEGREES. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2016-11-04 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-11-04 |
Time |
12:37 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-11-04 |
Time |
12:37 |
Sent To |
|
|
Notes |
2016-11-04 12:53:46 | 3RD REVIEW FBC-2014 MECHANICAL | | PERMIT #16080974 | | 11/4/16 | | | | 1) REFER TO SECTION 508.1.1: IF CHOOSING NOT TO PROVIDE | | CONDITIONED MAKEUP AIR, PLEASE PROVIDE AN AC | | CALCULATION THAT INCORPORATES THE ADDITIONAL HEAT LOAD | | FROM THE MAKEUP AIR. THE CALCULATION MUST INDICATE THAT | | THE EXISTING SYSTEM CAN HANDLE THE ADDITINAL LOAD. | | PLEASE SEE SECTION R302.1 FBC-14 ENERGY CONSERVATION | | FOR INTERIOR DESIGN TEMPERATURE (75 DEGREES F FOR | | COOLING). | | | | 2) PROVIDE THE TYPES AND SIZES OF MAKEUP AIR DUCTS, AND | | REFER TO SECTION 507.9 FOR CLEARANCES TO COMBUSTIBLES. | | | | 3) AS PREVIOUSLY REQUESTED IN THE 1ST REVIEW, PROVIDE | | THE PROJECT ADDRESS ON THE PLANS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2016-09-19 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-09-19 |
Time |
12:38 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-09-19 |
Time |
12:38 |
Sent To |
|
|
Notes |
2016-09-19 12:44:25 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #16080974 | | 9/19/16 | | | | 1) SUBMIT THE NOA'S FOR THE FANS. | | | | 2) CLARIFY HOW COMPLIANCE IS BEING MET FOR MAKEUP AIR | | TEMPERATURE- SEE SECTION 508.1.1 FBC-14 MECH. | | | | 3) PROVIDE AN ENLARGED DETAIL FOR THE GREASE DUCT | | ENCLOSURE AT THE ROOF PENETRATION. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-09-02 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2016-09-02 |
Time |
07:28 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2016-09-01 |
Time |
15:34 |
Sent To |
|
|
Notes |
2016-09-02 07:26:33 | PLAN DENIED | | NO ADRESS ON PLANS PER SECTION107 | | 2014 FBC. | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 |
|
|