Plan Review Stops For Permit 16080757 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2016-09-29 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-09-29 |
Time |
13:29 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-09-29 |
Time |
13:29 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2016-09-12 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-09-12 |
Time |
14:48 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-09-12 |
Time |
14:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-08-25 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-08-25 |
Time |
08:55 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-08-25 |
Time |
08:55 |
Sent To |
E |
|
Notes |
2016-08-25 08:58:27 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER ? PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1. VALUE APPEARS LOW. PROVIDE COPY OF CONTRACT SIGNED | | BY OWNER. | | | | FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | FAILURE TO PROVIDE DOCUMENTATION OF ESTIMATED COSTS MAY | | DELAY THE APPLICATION PROCESS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2016-09-29 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-09-29 |
Time |
14:35 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-09-29 |
Time |
14:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2016-09-12 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-09-12 |
Time |
17:56 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-09-12 |
Time |
17:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-08-25 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-08-25 |
Time |
12:04 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-08-25 |
Time |
12:04 |
Sent To |
|
|
Notes |
2016-08-25 12:05:16 | REVIEW 2014 5TH FBC ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | | | | | 1] FBC-E SECTION C405.2.4 EXTERIOR LIGHTING CONTROLS. | | LIGHTING NOT DESIGNATED FOR DUSK-TO-DAWN OPERATION | | SHALL BE CONTROLLED BY EITHER A COMBINATION OF A | | PHOTOSENSOR AND A TIME SWITCH, OR AN ASTRONOMICAL TIME | | SWITCH. LIGHTING DESIGNATED FOR DUSK-TO-DAWN OPERATION | | SHALL BE CONTROLLED BY AN ASTRONOMICAL TIME SWITCH OR | | PHOTOSENSOR. | | ALL TIME SWITCHES SHALL BE CAPABLE OF RETAINING | | PROGRAMMING AND THE TIME SETTING DURING LOSS OF POWER | | FOR A PERIOD OF AT LEAST 10 HOURS. | | | | 2] PROVIDE AN OWNER SIGNED CONTRACT FOR THE PROPOSED | | WORK BECAUSE THE VALUATION SEEMS A BIT LOW. FBC 109.3 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-09-29 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-09-29 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-09-26 |
Time |
09:37 |
Sent To |
|
|
Notes |
2016-09-27 09:37:44 | RESUB ROUTED TO KMARTIN VIA ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-09-12 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-09-12 |
Time |
17:56 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-09-02 |
Time |
14:55 |
Sent To |
|
|
Notes |
2016-09-02 14:55:36 | RESUB ROUTED TO KMARTIN VIA ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-08-25 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-08-25 |
Time |
12:05 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-08-18 |
Time |
12:40 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2016-09-28 |
|
|
Cont ID |
|
Sent By |
|
Date |
2016-09-28 |
Time |
|
Rev Time |
0.00 |
Received By |
kmartin |
Date |
2016-09-28 |
Time |
09:27 |
Sent To |
B |
|
Notes |
2016-09-28 08:14:32 | ROUTED TO KEVIN MARTIN |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2016-09-08 |
|
|
Cont ID |
|
Sent By |
|
Date |
2016-09-08 |
Time |
|
Rev Time |
0.00 |
Received By |
kmartin |
Date |
2016-09-08 |
Time |
09:43 |
Sent To |
B |
|
Notes |
2016-09-08 09:48:25 | 1. SIGN EXCEEDS MAXIMUM VERTICAL DIMENSION OF 36 | | INCHES. | | | | FOR MORE INFORMATION PLEASE CONTACT KEVIN MARTIN, URBAN | | DESIGN PLANNER AT [email protected]. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2016-08-24 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-08-25 |
Time |
12:05 |
Rev Time |
0.00 |
Received By |
kmartin |
Date |
2016-08-24 |
Time |
09:24 |
Sent To |
B |
|
Notes |
2016-08-24 09:27:49 | PROVIDE DIMENSIONS FOR THE TOTAL AREA OF THE SIGN. SIGN | | MUST BE IN LINE WITH ALL OTHER SIGNS ON THE FACADE. | | | | FOR MORE INFORMATION PLEASE CONTACT KEVIN MARTIN, URBAN | | DESIGN PLANNER AT (561) 822-1426 OR [email protected]. | 2016-08-19 16:26:05 | ROUTED TO KEVIN MARTIN |
|
|