Plan Review Stops For Permit 16080657 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2017-06-21 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-06-21 |
Time |
12:26 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-06-21 |
Time |
11:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2016-12-01 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-12-01 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-12-01 |
Time |
10:20 |
Sent To |
|
|
Notes |
2016-12-01 10:20:53 | BUILDING PLAN REVIEW | | W. P. B. REVISION: 16080657 | | W. P. B. PERMIT: 14120431 | | ADD: 312 23RD ST. | | CONT: BRADLEY CONSTRUCTION | | TEL: (727)641-2367 | | E-MAIL: ???????????????????? PLEASE PROVIDE E-MAIL | | ADDRESS THAT IS HOW WE NOTIFY YOU!!!!!! | | | | PARK PALM BEACH MULTIFAMILY RESIDENTIAL | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | 3RD REVIEW | | DATE: THURS. DEC. 01/ 2016 | | ACTION: DENIED | | | | 1) REV. # 5 WAS SUBMITTED AND APPROVED BY BUILDING BUT | | NOT ALL TRADES. WHEN RESUBMITTED REV. # 6 WAS ALSO | | INCLUDED IN THIS REVIEW. REVISION # 6 SHOULD HAVE BEEN | | NOTED ON THE REVISION FORM, SINCE REVISION # 5 WAS NOT | | APPROVED BY ALL DISCIPLINES AND THE NEW SHEETS INSERTED | | IN THE PLANS, OLD ONES REMOVED AND MARKED VOID. | | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION 107.2.1.4 | | QUALITY OF BUILDING PLANS. THE BUILDING OFFICIAL MAY | | ESTABLISH THROUGH DEPARTMENTAL POLICY, OTHER STANDARDS | | FOR PLANS AND SPECIFICATIONS, IN ORDER TO PROVIDE | | CONFORMITY TO ITS RECORD RETENTION PROGRAM. THIS POLICY | | MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, SHAPE, | | CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO RECORDS | | MANAGEMENT. | | | | 2) FAIR HOUSING PLEASE REVIEW SHEET A-3.22. THE SWING | | OF THE SHOWER DOOR IN THE MASTER BATH, UNIT B3 | | INFRINGES ON THE REQUIRED 30 X48 INCH CLEAR FLOOR SPACE | | PARALLEL TO THE SHOWER. | | | | 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2016-10-11 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-10-11 |
Time |
08:30 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-10-11 |
Time |
08:00 |
Sent To |
|
|
Notes |
2016-10-11 08:30:18 | PASSED FAIR HOUSING GUIDELINE (2) USEABLE BATHROOMS | | (B)(VI).SHEET A-3.10. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-09-06 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-09-06 |
Time |
09:30 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-09-02 |
Time |
14:17 |
Sent To |
|
|
Notes |
2016-09-06 09:30:55 | BUILDING PLAN REVIEW | | W. P. B. REVISION: 16080657 | | W. P. B. PERMIT: 14120431 | | ADD: 312 23RD ST. | | PCN:74-43-43-10-19-003-0143 | | CONT: BRADLEY CONSTRUCTION | | TEL: (727)641-2367 | | E-MAIL: ??????????????? | | | | PARK PALM BEACH MULTIFAMILY RESIDENTIAL | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 1ST REVIEW | | DATE: FRI. SEPT. 02/ 2016 | | ACTION: DENIED | | | | 1) SHEET A-3.10 A SINGLE BEDROOM/ BATH UNIT. THE BATH | | MUST BE A SPECIFICATION A OR SPECIFICATION B, THIS | | DESIGN IS NEITHER AN A OR B SPECIFICATION. TO HAVE THE | | VALVES AS SHOWN YOU WOULD HAVE TO HAVE A 30X 48 INCH | | PARALLEL APPROACH WITH THE 48 INCHES STARTING AT THE | | CONTROL WALL AND PARALLELING THE TUB. THE WATER CLOSET | | IS IN THE WAY. THE WATER CLOSET WOULD NEED TO BE A | | MINIMUM OF 30 INCHES AWAY FROM THE TUB TO THE EDGE OF | | THE WATER CLOSET. THE ORIGINAL DESIGN THE FAIR HOSING | | GUIDELINES SHOW THE CONTROL VALVES ARE ON THE SAME WALL | | AS THE WATER CLOSET THIS CONFORMS TO THE SPECIFICATION | | A. | | | | THE DESIGN PROFESSIONAL IS REQUIRED TO DESIGNATE TO | | WHICH STANDARD THE UNIT BATHROOMS WERE DESIGNED. | | IF SPECIFICATION A IS SELECTED AS THE BASIS FOR | | DESIGNING A BATHROOM, ALL BATHROOMS IN THE DWELLING | | UNIT ALSO MUST COMPLY WITH THE A SPECIFICATION. IF | | SPECIFICATION B IS SELECTED, ONLY ONE BATHROOM IN THE | | DWELLING UNIT MUST MEET THOSE REQUIREMENTS: ALL OTHER | | BATHROOMS IN THE DWELLING UNIT MUST BE ON AN ACCESSIBLE | | ROUTE, DOORS HAVING A 32-INCH CLEAR OPENING. | | | | 2A) SHEET A3.22 SHOWS A DWELLING UNIT WITH 2 BEDROOMS | | AND 2 BATHROOMS, ONE HAS A TUB THE OTHER A SHOWER. THE | | DESIGN PROFESSIONAL IS REQUIRED TO DESIGNATE TO WHICH | | STANDARD THE UNIT BATHROOMS WERE DESIGNED. | | IF SPECIFICATION A IS SELECTED AS THE BASIS FOR | | DESIGNING A BATHROOM, ALL BATHROOMS IN THE DWELLING | | UNIT ALSO MUST COMPLY WITH THE A SPECIFICATION. IF | | SPECIFICATION B IS SELECTED, ONLY ONE BATHROOM IN THE | | DWELLING UNIT MUST MEET THOSE REQUIREMENTS: ALL OTHER | | BATHROOMS IN THE DWELLING UNIT MUST BE ON AN ACCESSIBLE | | ROUTE, DOORS HAVING A 32-INCH CLEAR OPENING. | | IF THE DESIGNER INDICATES THAT BATHROOM # 2 IS DESIGNED | | AS THE SPECIFICATION B THEN THE REQUIREMENTS HAVE BEEN | | SATISFIED. | | | | 2B) SHEET A3.22 DETAIL # 9 ONLY GIVE THE REQUIRED | | LOCATION FOR THE BACKING AND GRAB BAR FOR THE TOE END | | OF THE TUB. NOT THE BACK WALL NOR THE HEAD OF THE TUB. | | SEE EXAMPLE ?B? FAIR HOUSING. | | | | 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2016-08-25 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-08-25 |
Time |
08:39 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-08-25 |
Time |
07:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2017-06-15 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2017-06-15 |
Time |
17:15 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2017-06-15 |
Time |
16:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2016-11-10 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2016-11-10 |
Time |
11:06 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2016-11-10 |
Time |
10:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2016-08-31 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2016-08-31 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2016-08-31 |
Time |
09:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-06-21 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-06-21 |
Time |
12:34 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-06-09 |
Time |
10:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-12-01 |
|
|
Cont ID |
|
Sent By |
|
Date |
2016-12-01 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2016-11-01 |
Time |
12:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-09-19 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2016-09-19 |
Time |
11:37 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2016-08-16 |
Time |
15:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2017-06-21 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-06-21 |
Time |
12:33 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-06-21 |
Time |
12:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2017-06-20 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-06-20 |
Time |
08:57 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-06-20 |
Time |
08:36 |
Sent To |
|
|
Notes |
2017-06-20 09:00:08 | 4TH REVIEW: FBC 2014 5TH EDITION | | | | PLUMBING COMMENTS: PREVIOUS COMMENT 2ND REQUEST | | | | NOT COMPLIED 1) SHT. A-3.22 - THE SWING OF THE SHOWER | | DOOR IN THE MASTER BATH IN UNIT B3 INFRINGES ON THE | | REQUIRED 30 INCH BY 48 INCH CLEAR FLOOR SPACE PARALLEL | | TO THE SHOWER . CHANGING THE DOOR SWING WILL CORRECT | | THIS ISSUE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2016-11-28 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-11-28 |
Time |
05:23 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-11-28 |
Time |
04:51 |
Sent To |
|
|
Notes |
2016-11-28 05:22:16 | 1) SHT. A-3.22 - THE SWING OF THE SHOWER DOOR IN THE | | MASTER BATH IN UNIT B3 INFRINGES ON THE REQUIRED 30 | | INCH BY 48 INCH CLEAR FLOOR SPACE PARALLEL TO THE | | SHOWER . CHANGING THE DOOR SWING WILL CORRECT THIS | | ISSUE. | | 2) THE REVISED SHEETS A-0.00, A-0.01, A-3.10 & A-3.22 | | SHALL BE SUBMITTED INTO THE FULL SET OF PLANS AND THE | | OLD PAGES REMOVED. 3RD REQUEST. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2016-10-13 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-10-13 |
Time |
10:04 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-10-13 |
Time |
09:24 |
Sent To |
|
|
Notes |
2016-10-13 09:46:51 | 1) THE DESIGN PROFESSIONAL IS REQUIRED TO DESIGNATE TO | | WHICH DESIGN SPECIFICATION ( A OR B) OF THE FAIR | | HOUSING ACT THE UNIT BATHROOMS WERE DESIGNED. 2ND | | REQUEST | | IF SPECIFICATION A IS SELECTED AS THE BASIS FOR | | DESIGNING A BATHROOM, ALL BATHROOMS IN THE DWELLING | | UNIT ALSO MUST COMPLY WITH THE A SPECIFICATION. IF | | SPECIFICATION B IS SELECTED, ONLY ONE BATHROOM IN THE | | DWELLING UNIT MUST MEET THOSE REQUIREMENTS: ALL OTHER | | BATHROOMS IN THE DWELLING UNIT MUST BE ON AN ACCESSIBLE | | ROUTE, DOORS HAVING A 32-INCH CLEAR OPENING. | | 2A) SHEET A3.22 - UNIT B3 - SHOWS A DWELLING UNIT WITH | | 2 BEDROOMS AND 2 BATHROOMS, ONE HAS A TUB THE OTHER A | | SHOWER. THE DESIGN PROFESSIONAL IS REQUIRED TO | | DESIGNATE TO WHICH DESIGN SPECIFICATION OF THE FAIR | | HOUSING ACT (A OR B) THE UNIT BATHROOMS WERE DESIGNED. | | IF SPECIFICATION A IS SELECTED AS THE BASIS FOR | | DESIGNING A BATHROOM, ALL BATHROOMS IN THE DWELLING | | UNIT ALSO MUST COMPLY WITH THE A SPECIFICATION. IF | | SPECIFICATION B IS SELECTED, ONLY ONE BATHROOM IN THE | | DWELLING UNIT MUST MEET THOSE REQUIREMENTS: ALL OTHER | | BATHROOMS IN THE DWELLING UNIT MUST BE ON AN ACCESSIBLE | | ROUTE, DOORS HAVING A 32-INCH CLEAR OPENING. | | 3) SHT. A-3.10 & A-.21 - WATER SUPPLY VALVES FOR THE | | STACKED WASHER/DRYER UNIT SHALL BE ACCESSIBLE PER 2010 | | FPC SEC.606.3. NOTE THIS ON THE PLAN.2ND REQUEST. | | 4) SHT. A-3.41 - SHOW THE LENGTH AND WIDTH DIMENSIONS | | OF THE ACCESSIBLE TOILET ROOMS ON DETAILS #3 & #4. 2ND | | REQUEST. | | 5)WHEN SUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2016-09-14 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-09-14 |
Time |
05:10 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-09-14 |
Time |
03:35 |
Sent To |
|
|
Notes |
2016-09-14 03:38:24 | | | PARK PALM BEACH MULTIFAMILY RESIDENTIAL | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 1ST REVIEW | | DATE: 9/14/2016 | | ACTION:DENIED | | | | 1) SHEET A-3.10 - SINGLE BEDROOM/ BATH UNIT. THE BATH | | MUST BE A SPECIFICATION A OR SPECIFICATION B, THIS | | DESIGN IS NEITHER AN A OR B SPECIFICATION. TO HAVE THE | | VALVES AS SHOWN YOU WOULD HAVE TO HAVE A 30X 48 INCH | | PARALLEL APPROACH WITH THE 48 INCHES STARTING AT THE | | CONTROL WALL AND PARALLELING THE TUB. THE WATER CLOSET | | IS IN THE WAY. THE WATER CLOSET WOULD NEED TO BE A | | MINIMUM OF 30 INCHES AWAY FROM THE TUB TO THE EDGE OF | | THE WATER CLOSET. THE ORIGINAL DESIGN OF THE FAIR | | HOSING GUIDELINES SHOW THE CONTROL VALVES ARE ON THE | | SAME WALL AS THE WATER CLOSET. THIS CONFORMS TO THE | | SPECIFICATION A. | | | | THE DESIGN PROFESSIONAL IS REQUIRED TO DESIGNATE TO | | WHICH STANDARD THE UNIT BATHROOMS WERE DESIGNED. | | IF SPECIFICATION A IS SELECTED AS THE BASIS FOR | | DESIGNING A BATHROOM, ALL BATHROOMS IN THE DWELLING | | UNIT ALSO MUST COMPLY WITH THE A SPECIFICATION. IF | | SPECIFICATION B IS SELECTED, ONLY ONE BATHROOM IN THE | | DWELLING UNIT MUST MEET THOSE REQUIREMENTS: ALL OTHER | | BATHROOMS IN THE DWELLING UNIT MUST BE ON AN ACCESSIBLE | | ROUTE, DOORS HAVING A 32-INCH CLEAR OPENING. | | | | 2A) SHEET A3.22 SHOWS A DWELLING UNIT WITH 2 BEDROOMS | | AND 2 BATHROOMS, ONE HAS A TUB THE OTHER A SHOWER. THE | | DESIGN PROFESSIONAL IS REQUIRED TO DESIGNATE TO WHICH | | STANDARD THE UNIT BATHROOMS WERE DESIGNED. | | IF SPECIFICATION A IS SELECTED AS THE BASIS FOR | | DESIGNING A BATHROOM, ALL BATHROOMS IN THE DWELLING | | UNIT ALSO MUST COMPLY WITH THE A SPECIFICATION. IF | | SPECIFICATION B IS SELECTED, ONLY ONE BATHROOM IN THE | | DWELLING UNIT MUST MEET THOSE REQUIREMENTS: ALL OTHER | | BATHROOMS IN THE DWELLING UNIT MUST BE ON AN ACCESSIBLE | | ROUTE, DOORS HAVING A 32-INCH CLEAR OPENING. | | IF THE DESIGNER INDICATES THAT BATHROOM # 2 IS DESIGNED | | AS THE SPECIFICATION B THEN THE REQUIREMENTS HAVE BEEN | | SATISFIED. | | | | 2B) SHEET A3.22 DETAIL # 9 ONLY GIVE THE REQUIRED | | LOCATION FOR THE BACKING AND GRAB BAR FOR THE TOE END | | OF THE TUB. NOT THE BACK WALL NOR THE HEAD OF THE TUB. | | SEE FIGURE "4" FROM FAIR HOUSING REQS. IN 2010 FAC & | | ALSO 24 CFR 100.205. | | | | 3) SHT. A-3.10 & A-.21 - WATER SUPPLY VALVES FOR THE | | STACKED WASHER/DRYER UNIT SHALL BE ACCESSIBLE PER 2010 | | FPC SEC.606.3. | | | | 4) SHT. A-3.41 - SHOW THE LENGTH AND WIDTH DIMENSIONS | | OF THE ACCESSIBLE TOILET ROOMS ON DETAILS #3 & #4. | | | | 5)WHEN SUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2016-11-17 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2016-11-17 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2016-11-17 |
Time |
09:56 |
Sent To |
|
|
Notes |
2016-11-17 14:20:36 | PROVISO | | | | ALL ZONING PROVISOS (DATED 6/15/15) AND SHOWN ON THE | | ORIGINALLY-PERMITTED PLANS REMAIN IN EFFECT. | | | | | | QUESTIONS/COMMENTS, CONTACT | | JOHN ROACH, PRINCIPAL PLANNER, AT | | [email protected] OR (561) 822-1448. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2016-09-19 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2016-09-19 |
Time |
11:37 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2016-09-19 |
Time |
11:37 |
Sent To |
|
|
Notes |
2016-09-19 11:41:00 | PROVISO | | | | ALL ZONING PROVISOS (DATED 6/15/15) AND SHOWN ON THE | | ORIGINALLY-PERMITTED PLANS REMAIN IN EFFECT. | | | | | | QUESTIONS/COMMENTS, CONTACT | | JOHN ROACH, PRINCIPAL PLANNER, AT | | [email protected] OR (561) 822-1448. | | |
|
|