Plan Review Details - Permit 16080524
Plan Review Stops For Permit 16080524
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-09-22 Cont ID  
Sent By jwitmer Date 2016-09-22 Time 06:56 Rev Time 0.00
Received By jwitmer Date 2016-09-22 Time 06:27 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-08-17 Cont ID  
Sent By jwitmer Date 2016-08-17 Time 05:59 Rev Time 0.00
Received By jwitmer Date 2016-08-17 Time 05:41 Sent To  
Notes
2016-08-17 05:56:06BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16080524
 ADD: 1501 S. FLAGLER DR. SUITE # 6-H
 CONT: J & G CARPENTRY
 TEL: 561-855-4052
 E-MAIL: CHERYL@ JANDGCARPENTRY.COM
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. AUGUST 17/ 2016
 ACTION: DENIED
  
 1) PLEASE SEE PAGE 4 OF 17 IN THE CONTRACT. J & G WILL
 DEMO EXISTING TILE INSTALL NEW OWNER SUPPLIED TILE.
 J & G WOULD SUPPLY UNDERLAYMENT.
 BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION (FBC-B
 2014)
 FOR TILE, STONE, MARBLE AND WOOD FLOORING ALL NEED TO
 HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES
 TO THE FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS
 LISTED UNDER EACH OF THE STANDARDS FOR A 6 INCH
 CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING:
 PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH:
  
 A) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 B) FBC-B 2014 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 C) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 DEVELOPMENT SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-09-26 Cont ID  
Sent By mvaldes Date 2016-09-26 Time 17:00 Rev Time 0.00
Received By mvaldes Date 2016-09-26 Time 16:41 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-08-18 Cont ID  
Sent By mvaldes Date 2016-08-18 Time 14:05 Rev Time 0.00
Received By mvaldes Date 2016-08-18 Time 13:30 Sent To  
Notes
2016-08-18 14:09:23REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
 1) PROVIDE GFCI PROTECTION FOR THE KITCHEN COUNTER-TOP
 RECEPTACLES. NEC 210.8.A.6 [ADD TO OUTLET SYMBOL]
  
 2) TAMPER-RESISTANT RECEPTACLES REQUIRED PER NEC 406.12
 [ADD A NOTE]
  
 3) SMOKE ALARMS REQUIRED PER FBC-R 314 & 315. IF
 EXISTING MAKE A NOTE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-10-05 Cont ID  
Sent By tklarge Date 2016-10-05 Time 04:12 Rev Time 0.00
Received By tklarge Date 2016-09-12 Time 14:57 Sent To  
Notes
2016-09-12 14:57:40B20

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-09-09 Cont ID  
Sent By gjohnson Date 2016-09-09 Time 15:38 Rev Time 0.00
Received By gjohnson Date 2016-08-11 Time 15:25 Sent To  
Notes
2016-08-11 15:25:58B38

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-10-05 Cont ID  
Sent By tklarge Date 2016-10-05 Time 04:12 Rev Time 0.00
Received By tklarge Date 2016-10-05 Time 03:59 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-09-09 Cont ID  
Sent By gjohnson Date 2016-09-09 Time 15:38 Rev Time 0.00
Received By gjohnson Date 2016-09-09 Time 15:38 Sent To  
Notes
***NONE***