Plan Review Stops For Permit 16080290 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2016-11-07 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-11-07 |
Time |
15:45 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-11-07 |
Time |
15:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2016-10-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-10-14 |
Time |
07:59 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-10-14 |
Time |
07:31 |
Sent To |
|
|
Notes |
2016-10-14 07:49:23 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 16080290 | | ADD: 321 S. DIXIE HWY. | | CONT: MASTER CONTRACTOR | | TEL: 561-248-5498 | | E-MAIL: MASTERCONTRACTORS@?????????? | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE: SAT. AUGUST 13/ 2016 | | ACTION: DENIED | | | | 1) COMPLIED. THE COVERSHEET INDICATES THIS 2 STORY | | BUILDING IS A BUILDING TYPE IIA-SPRINKLERED. PLEASE | | NOTE THIS 2 STORY BUILDING WAS BUILT IN 1925 THE 1ST | | FLOOR CONSISTING OF EITHER BUSINESS AND OR MERCANTILE. | | THIS BUILDING TYPE IS NOT A TYPE IIA BUILDING, MORE | | LIKELY A TYPE VB. A TYPE IIA MEANS THERE IS NO WOOD IN | | THE STRUCTURE AND ALL OF THE STRUCTURAL MEMBERS ARE 1 | | HOUR FIRE PROTECTED PER TABLE 601. | | | | 2)2ND REQUEST. PLEASE PROVIDE HOW MANY SQUARE FEET MAKE | | UP THE RETAIL PORTION OF THIS TENANT SPACE TO SEE IF IT | | IS A MIXED USE OCCUPANCY. THE COVERSHEET ALSO LIST THE | | OCCUPANCY TYPE AS BUSINESS/ RETAIL, THE TENANCY SQUARE | | FOOTAGE OF 827 AND AN OCCUPANT LOAD OF 13. PLEASE | | PROVIDE THE SQUARE FOOTAGE FOR THE BEAUTY SALOON | | PORTION THAT WILL BE BUSINESS OCCUPANCY AND THE POTION | | THAT WILL BE MERCANTILE OCCUPANCY. THIS TENANCY MAY BE | | CLASSIFIED AS A MIXED USE OCCUPANCY. | | 2014 FBC-B 508.2.1 AREA LIMITATIONS. AGGREGATE | | ACCESSORY OCCUPANCIES SHALL NOT OCCUPY MORE THAN 10 | | PERCENT OF THE BUILDING AREA OF THE STORY (TENANT | | SPACE) IN WHICH THEY ARE LOCATED AND SHALL NOT EXCEED | | THE TABULAR VALUES IN TABLE 503, WITHOUT BUILDING AREA | | INCREASES IN ACCORDANCE WITH SECTION 506 FOR SUCH | | ACCESSORY OCCUPANCIES. | | | | 3-4) COMPLIED. | | | | 5) SEMI COMPLIED. SHEET A-1. PLEASE NOTE THERE IS AN | | EXISTING STAIR TO A TENANCY ABOVE THIS UNIT. THE PLANS | | INDICATE AN EXISTING WATER HEATER BELOW THE STAIR | | ENCLOSURE. PLEASE PROVIDE COMPLIANCE WITH 2014 FBC-B | | 1009.9.3 ENCLOSURES UNDER INTERIOR STAIRWAYS. THE PLANS | | SHOW 2 OF THE 3 WALLS BEING FIRE RATED AND THE CEILING | | OF THE CLOSET NEEDS TO BE FIRE RATED AS WELL. | | THE WALLS, SOFFIT AND OR CEILING WITHIN ENCLOSED USABLE | | SPACES UNDER ENCLOSED AND UNENCLOSED STAIRWAYS SHALL BE | | PROTECTED BY 1-HOUR FIRE-RESISTANCE-RATED CONSTRUCTION | | OR THE FIRE-RESISTANCE RATING OF THE STAIRWAY | | ENCLOSURE, WHICHEVER IS GREATER. ACCESS TO THE ENCLOSED | | SPACE SHALL NOT BE DIRECTLY FROM WITHIN THE STAIR | | ENCLOSURE. | | | | 6) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-08-13 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-08-13 |
Time |
10:57 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-08-13 |
Time |
09:57 |
Sent To |
|
|
Notes |
2016-08-13 10:57:32 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 16080290 | | ADD: 321 S. DIXIE HWY. | | CONT: MASTER CONTRACTOR | | TEL: 561-248-5498 | | E-MAIL: MASTERCONTRACTORS@?????????? | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: SAT. AUGUST 13/ 2016 | | ACTION: DENIED | | | | 1) THE COVERSHEET INDICATES THIS 2 STORY BUILDING IS A | | BUILDING TYPE IIA-SPRINKLERED. PLEASE NOTE THIS 2 STORY | | BUILDING WAS BUILT IN 1925 THE 1ST FLOOR CONSISTING OF | | EITHER BUSINESS AND OR MERCANTILE. THIS BUILDING TYPE | | IS NOT A TYPE IIA BUILDING, MORE LIKELY A TYPE VB. A | | TYPE IIA MEANS THERE IS NO WOOD IN THE STRUCTURE AND | | ALL OF THE STRUCTURAL MEMBERS ARE 1 HOUR FIRE PROTECTED | | PER TABLE 601. | | | | 2) THE COVERSHEET ALSO LIST THE OCCUPANCY TYPE AS | | BUSINESS/ RETAIL, THE TENANCY SQUARE FOOTAGE OF 827 AND | | AN OCCUPANT LOAD OF 13. PLEASE PROVIDE THE SQUARE | | FOOTAGE FOR THE BEAUTY SALOON PORTION THAT WILL BE | | BUSINESS OCCUPANCY AND THE POTION THAT WILL BE | | MERCANTILE OCCUPANCY. THIS TENANCY MAY BE CLASSIFIED AS | | A MIXED USE OCCUPANCY. | | 2014 FBC-B 508.2.1 AREA LIMITATIONS. AGGREGATE | | ACCESSORY OCCUPANCIES SHALL NOT OCCUPY MORE THAN 10 | | PERCENT OF THE BUILDING AREA OF THE STORY (TENANT | | SPACE) IN WHICH THEY ARE LOCATED AND SHALL NOT EXCEED | | THE TABULAR VALUES IN TABLE 503, WITHOUT BUILDING AREA | | INCREASES IN ACCORDANCE WITH SECTION 506 FOR SUCH | | ACCESSORY OCCUPANCIES. | | | | 3) THE COVERSHEET LIST 13 OCCUPANTS BUT THE FLOOR PLAN | | INDICATES IF EACH CHAIR IS TAKEN BY AN OCCUPANT AND | | BEAUTICIAN AT EACH STATION THE OCCUPANT LOAD WOULD BE | | CLOSER TO 30 OCCUPANTS. | | 2014 FBC-B 1004.2 INCREASED OCCUPANT LOAD. THE OCCUPANT | | LOAD PERMITTED IN ANY BUILDING, OR PORTION THEREOF, IS | | PERMITTED TO BE INCREASED FROM THAT NUMBER ESTABLISHED | | FOR THE OCCUPANCIES IN TABLE 1004.1.2, PROVIDED THAT | | ALL OTHER REQUIREMENTS OF THE CODE ARE ALSO MET BASED | | ON SUCH MODIFIED NUMBER AND THE OCCUPANT LOAD DOES NOT | | EXCEED ONE OCCUPANT PER 7 SQUARE FEET (0.65 M2) OF | | OCCUPIABLE FLOOR SPACE. | | | | 4) SHEET A-1. THE DOOR SWING OF THE LAUNDRY ROOM DOOR | | SWINGS OVER ? OF THE REQUIRED EGRESS PATH. 1005.7.1 | | DOORS. | | DOORS, WHEN FULLY OPENED, SHALL NOT REDUCE THE REQUIRED | | WIDTH BY MORE THAN 7 INCHES (178 MM). DOORS IN ANY | | POSITION SHALL NOT REDUCE THE REQUIRED WIDTH BY MORE | | THAN ONE-HALF. | | | | 5) SHEET A-1. PLEASE NOTE THERE IS AN EXISTING STAIR TO | | A TENANCY ABOVE THIS UNIT. THE PLANS INDICATE AN | | EXISTING WATER HEATER BELOW THE STAIR ENCLOSURE. PLEASE | | PROVIDE COMPLIANCE WITH 2014 FBC-B 1009.9.3 ENCLOSURES | | UNDER INTERIOR STAIRWAYS. | | THE WALLS AND SOFFITS WITHIN ENCLOSED USABLE SPACES | | UNDER ENCLOSED AND UNENCLOSED STAIRWAYS SHALL BE | | PROTECTED BY 1-HOUR FIRE-RESISTANCE-RATED CONSTRUCTION | | OR THE FIRE-RESISTANCE RATING OF THE STAIRWAY | | ENCLOSURE, WHICHEVER IS GREATER. ACCESS TO THE ENCLOSED | | SPACE SHALL NOT BE DIRECTLY FROM WITHIN THE STAIR | | ENCLOSURE. | | | | 6) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | THIS REVIEW. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2016-11-09 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-11-09 |
Time |
16:39 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-11-09 |
Time |
14:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2016-11-03 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-11-03 |
Time |
10:21 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-11-03 |
Time |
10:21 |
Sent To |
|
|
Notes |
2016-11-03 10:21:33 | PREVIOUSLY APPROVED BY MIKE ALBARRAN |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2016-09-29 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-09-29 |
Time |
14:13 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-09-29 |
Time |
13:30 |
Sent To |
|
|
Notes |
2016-09-29 14:14:42 | ELECTRICAL REVIEW APPROVED. ALL PREVIOUSLY MENTIONED | | DEFICIENCIES HAVE BEEN SATISFACTORILY ADDRESSED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-08-12 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-08-12 |
Time |
10:43 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-08-12 |
Time |
10:00 |
Sent To |
|
|
Notes |
2016-08-12 10:43:26 | ELECTRICAL REVIEW NOTES | | REVIEWED FOR COMPLIANCE WITH: | | 5TH EDITION FBC 2014 & NFPA 70 2011 (NEC) | | | | PROJECT NAME: FUSION HAIR SALON | | JOB ADDRESS: 321 S. DIXIE HWY. | | DESCRIPTION: INTERIOR IMPROVEMENT ? NEW HAIR SALON | | MASTER PERMIT: 16080290 | | | | BELOW ARE COMMENTS RELATED TO THE FAILED ELECTRICAL | | REVIEW: | | | | 1. NEC 700.12 (F) (4) - EMERGENCY LIGHTING SHALL BE FED | | BY LIGHTING CIRCUIT OF SAME LOCAL AREA. *IF 3 OR MORE | | LIGHTING CIRCUITS SUPPLY THE AREA, EM LIGHTS MAY BE ON | | OWN CIRCUIT, OTHERWISE THEY SHALL BE ON THE SAME | | CIRCUIT AS FOR THE LIGHTING OF THE ROOM THEY OCCUPY. | | 2. NEC 600.5 - EACH COMMERCIAL BUILDING AND EACH | | COMMERCIAL OCCUPANCY ACCESSIBLE TO PEDESTRIANS SHALL BE | | PROVIDED WITH AT LEAST ONE 20 AMP DEDICATED OUTLET IN | | AN ACCESSIBLE LOCATION AT EACH ENTRANCE TO EACH TENANT | | SPACE FOR SIGN OR OUTLINE LIGHTING. SERVICE HALLWAYS OR | | CORRIDORS SHALL NOT BE CONSIDERED ACCESSIBLE TO | | PEDESTRIANS. THE SUBMITTED DRAWING DOES NOT INDICATE | | THIS ON THE PANEL SCHEDULE OR THE FLOOR PLAN. | | 3. NEC 210.62 SHOW WINDOWS. AT LEAST ONE RECEPTACLE | | OUTLET SHALL BE INSTALLED WITHIN 18? OF THE TOP OF A | | SHOW WINDOW FOR EVERY 12 LINEAR FT. OR MAJOR PORTION | | THEREOF AREA MEASURED HORIZONTALLY. THE SUBMITTED | | DRAWING DOES NOT INDICATE THIS ON THE PANEL SCHEDULE OR | | THE FLOOR PLAN. | | 4. NEC 422.31. PERMANENTLY CONNECTED APPLIANCE OF OVER | | 300 VA OR 1/8 HP REQUIRES A DISCONNECT WITHIN SIGHT OF | | THE APPLIANCE. MARK ON THE PLANS THE DISCONNECT FOR THE | | WATER HEATER. | | 5. NEC 110.16 ARC-FLASH HAZARD WARNING: ELECTRICAL | | EQUIPMENT IN OTHER THAN DWELLING UNITS LIKELY TO | | REQUIRE SERVICE WHILE ENERGIZED SHALL BE FIELD MARKED | | TO WARN AGAINST POTENTIAL ARC-FAULT HAZARDS. THIS CAN | | BE ADDRESSED WITH A BLOCK NOTE ON THE PLANS. | | 6. NEC 110.24 THE MAXIMUM AVAILABLE FAULT CURRENT SHALL | | BE DURABLY MARKED AND DATED ON ALL NON-DWELLING | | ELECTRICAL APPARATUS. THIS CAN BE ADDRESSED WITH A | | BLOCK NOTE ON THE PLANS. | | 7. NEC 110.26(D) ILLUMINATION. ILLUMINATION SHALL BE | | PROVIDED FOR ALL WORKING SPACES ABOUT SERVICE | | EQUIPMENT, SWITCHBOARDS, AND PANELBOARDS. THIS LIGHT | | SHALL NOT BE CONTROLLED BY AUTOMATIC MEANS ONLY. | | 8. FBC-E SECTION C405 REQUIRES MANDATORY LIGHTING | | CONTROL. | | 9. FBC-EC 405.2.2.2 REQUIRES OCCUPANCY SENSORS IN THE | | RESTROOMS, STORAGE CLOSET, PRIVATE OFFICES AND SIMILAR | | ROOMS. | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER | | (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER | | WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | GREATLY APPRECIATED. | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | | | THANK YOU, | | MIKE ALBARRAN | | ELECTRICAL PLANS EXAMINER | | PH: 561-805-6746 | | EMAIL: [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2016-09-16 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2016-09-16 |
Time |
12:01 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2016-09-16 |
Time |
10:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2016-08-10 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2016-08-10 |
Time |
12:19 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2016-08-10 |
Time |
12:02 |
Sent To |
|
|
Notes |
2016-08-10 12:18:59 | 321 SOUTH DIXIE HIGHWAY | | PERMIT #16080290 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | SHEET A2: WATER HEATER DOES NOT APPEAR TO BE FIRE | | SEPARATED FROM THE EXISTING STAIR. PER NFPA 101 SECTION | | 7.2.2.5.3.2, ENCLOSED, USABLE SPACE SHALL BE PERMITTED | | UNDER STAIRS, PROVIDED THAT THE SPACE SHALL BE | | SEPARATED FROM THE STAIR ENCLOSURE BY THE SAME FIRE | | RESISTANCE AS THE EXIT ENCLOSURE. | | | | SHEET A2: LAUNDRY DOOR SWING OBSTRUCTS EGRESS. PER NFPA | | 101 SECTION 7.2.1.4.3.1, DURING ITS SWING, ANY DOOR IN | | A MEANS OF EGRESS SHALL LEAVE NOT LESS THAN ONE-HALF OF | | THE REQUIRED WIDTH OF AN AISLE, CORRIDOR, HALLWAY OR | | LANDING UNOBSTRUCTED AND SHALL PROJECT NOT MORE THAN | | 7-INCHES INTO THE REQUIRED WIDTH OF THE EGRESS PATH | | WHEN FULLY OPEN. | | | | WESLEY JOLIN | | ASSISTANT FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2016-11-09 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-11-09 |
Time |
16:39 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-11-09 |
Time |
14:22 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-11-07 |
|
|
Cont ID |
|
Sent By |
|
Date |
2016-11-07 |
Time |
|
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2016-10-27 |
Time |
13:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-10-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-10-14 |
Time |
07:59 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-09-06 |
Time |
11:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-08-26 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-08-26 |
Time |
12:30 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-08-08 |
Time |
09:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2016-08-13 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-08-13 |
Time |
10:57 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-08-13 |
Time |
09:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2016-11-09 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-11-09 |
Time |
16:38 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-11-09 |
Time |
16:38 |
Sent To |
|
|
Notes |
2016-11-09 16:50:31 | MECHANICAL PROVISOS: | | FBC-14 MECHANICAL | | 11/9/16 | | | | 1) THE OUTSIDE AIR INTAKE SHALL BE LOCATED A MINIMUM OF | | 10' HORIZONTALLY FROM THE REAR DRIVEWAY AND PARKING | | AREA- SECTION 401.4 | | | | 2) THE EXHAUST OUTLETS SHALL TERMINATE A MINIMUM OF 10' | | ABOVE ADJOINING GRADE- SECTION 501.3.1 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2016-10-28 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-10-28 |
Time |
15:36 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-10-28 |
Time |
15:36 |
Sent To |
|
|
Notes |
2016-10-28 15:46:43 | 3RD REVIEW FBC-2014 MECHANICAL | | PERMIT #16080290 | | 10/28/16 | | | | 1) SHEET M1: THE AC SYSTEM IS NOTED AS EXISTING WITH NO | | CHANGES IN HOWEVER THERE IS AN EQUIPMENT SCHEDULE FOR A | | NEW 7.5 TON SPLIT SYSTEM ON THE PLAN, AND ALSO A NOTE | | SPECIFYING RELOCATION AND INSTALLATION OF DROPS AND | | RETURNS. PLEASE NOTE THE ELECTRICAL PQNEL SCHEDULE | | INDICATES AN RTU. PLEASE CLARIFY THE SCOPE OF THE | | PROPOSED PROJECT. | | | | 2) M-1: PROVIDE A DETAIL FOR INSTALLATION OF THE NEW | | AIR HANDLER (IF APPLICABLE) AND HOW THE RETURN DUCT | | SPECIFED AS "SURFACE MOUNTED" WILL CONNECT TO THE UNIT. | | INDICATE THE HEIGHT FROM THE FINISHED FLOOR TO THE | | UNDERSIDE OF THE SURFACE MOUNTED RETURN. | | | | 3) M-1: SHOW THE COMPONENTS OF THE SOURCE CAPTURE | | SYSTEM AT THE NAIL STATIONS INCLUDING THE EXHAUST DUCT | | RUNS FROM THE POINT OF CAPTURE TO THE DISCHARGE | | LOCATIONS AND THE TYPES AND SIZES OF DUCTWORK. SUBMIT | | MANUFACTURER'S SPECIFICATIONS FOR THE MANICURE TABLES | | AND ALL ASSOCIATED PRODUCTS WITH APPROVAL SIGNATURES BY | | THE DESIGNER OF RECORD. | | | | 4) M-1: INDICATE THE TYPE AND SIZE OF OUTSIDE AIR VENT | | TO BE INSTALLED AND SUBMIT MANUFACTURER'S | | SPECIFICATIONS AND A FL. PRODUCT APPROVAL AND/OR | | MIAMI-DADE NOA- SECTION 401.5. INDICATE WITH A NOTE, OR | | SHOW MEASUREMENTS TO VERIFY THE LOCATION OF THE AIR | | INLET MEETS THE MNINIMUM REQUIRED CLEARANCE DISTANCES | | PER SECTION 401.4. | | | | 5) SHOW THE LOCATION OF THE NEW AC CONDENSER AND | | PROVIDE ENGNEERING FOR INSTALLATION. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2016-09-19 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-09-19 |
Time |
17:36 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-09-19 |
Time |
17:36 |
Sent To |
|
|
Notes |
2016-09-19 17:51:39 | 2ND REVIEW FBC-2014 MECHANICAL | | PERMIT #16080290 | | 9/19/16 | | | | 1) THE REVISED PLAN SHOWS BOTH AN EXISTING 3TON AC | | SYSTEM TO REMAIN AND A NEW 5TON AC SYSTEM. IT APPEARS | | BY THE 1800 CFMS OF SUPPLY AIR SHOWN THAT THE NEW 5TON | | SYSTEM IS BEING INSTALLED- PLEASE REMOVE THE 3TON | | SCHEDULE AND ALL OTHER REFERENCES TO THE EXISTING 3 TON | | SYSTEM. | | | | 2) PLEASE CONSULT WITH A MECHANICAL ENGINEER AND AC | | MANUFACTURER FOR ACCURATE O/A CAPACITY IF THE NEW 5TON | | UNIT. VERY TYPICALLY, THE RATIO OF O/A TO SUPPLY AIR | | WILL BE 15-20%. 600 CFMS SHOWN WOULD REQUIRE A UNIT | | SIZED AT 7 OR 7.5 TONS. | | | | 3) A DUCT SMOKE DETECTOR IS REQUIRED IN THE RETURN AIR | | SYSTEM OF THE NEW 5TON SYSTEM, UNLESS MANUFACTURER'S | | SPECIFICATIONS INDICATE THE SYSTEM WILL NOT PRODUCE | | OVER 2000 CFMS OF SUPPLY AIR- SECTION 606.2.1. | | | | 4) PLEASE REVIEW COMMENTS #1, 2, & 4 FROM THE 1ST | | REVIEW PRINTED BELOW. THE REVISED PLAN DOES NOT A | | SOURCE CAPTURE SYSTEM AT THE NAIL STATIONS, DOES NOT | | SHOW EXHAUST FOR THE BEAUY SALON, AND THE O/A AND AIR | | BALANCE CALCULATIONS ARE INCORRECT. REQUIRED CLEARANCES | | FOR EXHAUSDT TERMINATION NOT SHOWN. | | | | 1) THE PLAN IS NOT IN COMPLIANCE WITH TABLE 403.3 AND | | FOOTNOTES B AND H. THE 4 NAIL STATIONS SHOWN REQUIRE 50 | | CFMS OF EXHAUST EACH, AND EACH NAIL STATION IS REQUIRED | | TO HAVE A SOURCE CAPTURE SYSTEM. THE BEAUTY SALON SPACE | | IN TOTAL IS REQUIRED TO HAVE AN EXHAUST VENTILATION | | SYSTEM DESIGNED AT 0.6 CFMS PER SQ. FT. PLEASE REVISE | | THE PLANS AND CALCULATIONS TO SHOW COMPLIANCE. | | PLEASE NOTE THAT O/A FOR THE SALON SHALL BE PROVIDED AT | | A RATE 20 CFMS PER PERSON AND 0.12 CFMS PER SQ. FT. OF | | SPACE. | | | | 2) PROVIDE AIR BALANCE CALCULATIONS- REFER TO SECTION | | 501.4 | | | | 4) INDICATE THE TYPES AND SIZES OF THE NEW EXHAUST | | DUCTS, AND VERIFY COMPLIANCE WITH SECTION 501.3.1 FOR | | OUTLET TERMINATION LOCATION, AND 501.3.2 FOR OPENING | | PROTECTION. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-08-15 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-08-15 |
Time |
15:28 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-08-15 |
Time |
15:28 |
Sent To |
|
|
Notes |
2016-08-15 15:57:52 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #16080290 | | 8/15/16 | | | | 1) THE PLAN IS NOT IN COMPLIANCE WITH TABLE 403.3 AND | | FOOTNOTES B AND H. THE 4 NAIL STATIONS SHOWN REQUIRE 50 | | CFMS OF EXHAUST EACH, AND EACH NAIL STATION IS REQUIRED | | TO HAVE A SOURCE CAPTURE SYSTEM. THE BEAUTY SALON SPACE | | IN TOTAL IS REQUIRED TO HAVE AN EXHAUST VENTILATION | | SYSTEM DESIGNED AT 0.6 CFMS PER SQ. FT. PLEASE REVISE | | THE PLANS AND CALCULATIONS TO SHOW COMPLIANCE. | | PLEASE NOTE THAT O/A FOR THE SALON SHALL BE PROVIDED AT | | A RATE 20 CFMS PER PERSON AND 0.12 CFMS PER SQ. FT. OF | | SPACE. | | | | 2) PROVIDE AIR BALANCE CALCULATIONS- REFER TO SECTION | | 501.4 | | | | 3) PROVIDE BOTH A REFLECTIVE CEILING PLAN, AND AN AC | | LAYOUT PLAN SHOWING THE LOCATIONS OF ALL SUPPLY AND | | RETURN DIFFUSERS AND GRILLS. THERE IS AN AIR DEVICE | | SCHEDULE ON M-1 BUT NO DETAILS ON THE PLAN. | | | | 4) INDICATE THE TYPES AND SIZES OF THE NEW EXHAUST | | DUCTS, AND VERIFY COMPLIANCE WITH SECTION 501.3.1 FOR | | OUTLET TERMINATION LOCATION, AND 501.3.2 FOR OPENING | | PROTECTION. | | | | 5) INDICATE HOW THE EXHAUST FANS WILL ACTIVATE. THE | | ELECTRICAL PLANS TO DO NOT INDICATE SWITCHES OR OTHER | | METHODS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2016-11-03 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-11-03 |
Time |
08:44 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-11-02 |
Time |
16:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2016-10-13 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-10-13 |
Time |
10:43 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-10-12 |
Time |
15:52 |
Sent To |
|
|
Notes |
2016-10-13 11:11:49 | 1ST REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | PREVIOUS COMMENTS | | 1. NOT COMPLIED SHT. A-3 DETAIL #6 SHOULD REFLECT THE | | PLAN.THE SIDE DIMENSION OF 60IN SHALL NOT HAVE ANY | | OTHER FIXTURES IN THAT SPACE THE DETAIL IS SHOWING THE | | LAVATORY. PER FBC ACC | | 604.3.1 AND 604.3.2 OVERLAP. | | THE REQUIRED CLEARANCE AROUND THE WATER CLOSET SHALL BE | | PERMITTED TO OVERLAP THE WATER CLOSET, ASSOCIATED GRAB | | BARS, DISPENSERS, SANITARY NAPKIN DISPOSAL UNITS, COAT | | HOOKS, SHELVES, ACCESSIBLE ROUTES, CLEAR FLOOR SPACE | | AND CLEARANCES REQUIRED AT OTHER FIXTURES, AND THE | | TURNING SPACE. NO OTHER FIXTURES OR OBSTRUCTIONS SHALL | | BE LOCATED WITHIN THE REQUIRED WATER CLOSET CLEARANCE. | | | | 2. NOT COMPLIED. LAVATORY'S IN PUBLIC BATHROOMS SHALL | | HAVE TEMPERED WATER DELIVERED FROM A TEMPERATURE | | LIMITING DEVICE THE THERMOSTAT ON THE WATER HEATER DOES | | NOT COMPLY. PER FBC PL 416.5 TEMPERED WATER FOR PUBLIC | | HAND-WASHING FACILITIES. | | TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES AND | | GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET FACILITIES | | PROVIDED FOR CUSTOMERS, PATRONS AND VISITORS. TEMPERED | | WATER SHALL BE DELIVERED THROUGH AN APPROVED | | WATER-TEMPERATURE LIMITING DEVICE THAT CONFORMS TO ASSE | | 1070 OR CSA B125.3. AND 607.1.1 TEMPERATURE LIMITING | | MEANS. | | A THERMOSTAT CONTROL FOR A WATER HEATER SHALL NOT SERVE | | AS THE TEMPERATURE LIMITING MEANS FOR THE PURPOSES OF | | COMPLYING WITH THE REQUIREMENTS OF THIS CODE FOR | | MAXIMUM ALLOWABLE HOT OR TEMPERED WATER DELIVERY | | TEMPERATURE AT FIXTURES. | | | | 8. NOT COMPLIED THE WATER HEATER SHALL BE PROVIDED WITH | | A MEANS OF CONTROLLING THERMAL EXPANSION THE | | TEMPERATURE AND PRESSURE RELIER VALVE DOES NOT COMPLY | | WITH THIS CODE SECTION. PER FBC PL 607.3 THERMAL | | EXPANSION CONTROL. | | A MEANS OF CONTROLLING INCREASED PRESSURE CAUSED BY | | THERMAL EXPANSION SHALL BE PROVIDED WHERE REQUIRED IN | | ACCORDANCE WITH SECTIONS 607.3.1 AND 607.3.2. AND 504.4 | | RELIEF VALVE. | | STORAGE WATER HEATERS OPERATING ABOVE ATMOSPHERIC | | PRESSURE SHALL BE PROVIDED WITH AN APPROVED, | | SELF-CLOSING (LEVERED) PRESSURE RELIEF VALVE AND | | TEMPERATURE RELIEF VALVE OR COMBINATION THEREOF. THE | | RELIEF VALVE SHALL CONFORM TO ANSI Z21.22. THE RELIEF | | VALVE SHALL NOT BE USED AS A MEANS OF CONTROLLING | | THERMAL EXPANSION. | | | | 11. NOT COMPLIED. SHOW THE SHUT OFF ON THE COLD WATER | | MAIN AND ALL THE DROPS. PER FBC PL | | 606.1 LOCATION OF FULL-OPEN VALVES. | | FULL-OPEN VALVES SHALL BE INSTALLED IN THE FOLLOWING | | LOCATIONS: | | | | 2. ON THE WATER DISTRIBUTION SUPPLY PIPE AT THE | | ENTRANCE INTO THE STRUCTURE. | | | | | | 5. ON THE TOP OF EVERY WATER DOWN-FEED PIPE IN | | OCCUPANCIES OTHER THAN ONE- AND TWO-FAMILY RESIDENTIAL | | OCCUPANCIES. | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2016-08-26 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-08-26 |
Time |
12:07 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-08-26 |
Time |
11:54 |
Sent To |
|
|
Notes |
2016-08-26 12:30:23 | 1ST REVIEW | | | | | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | 1. SHT. A-3 THE DETAIL # 6 DOES NOT COMPLYY WITH THE | | FLORIDA ACCESSIBILITY CODE 2014 IT SHA COMPL WITH FBC | | ACC. SEC 606 AND 604. | | | | 2. THE LAVATORY IN THE BATH ROOM SHALL COMPLY WITH FBC | | PL. 416.5 TEMPERED WATER FOR PUBLIC HAND-WASHING | | FACILITIES. | | TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES AND | | GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET FACILITIES | | PROVIDED FOR CUSTOMERS, PATRONS AND VISITORS. TEMPERED | | WATER SHALL BE DELIVERED THROUGH AN APPROVED | | WATER-TEMPERATURE LIMITING DEVICE THAT CONFORMS TO ASSE | | 1070 OR CSA B125.3. | | | | 3. THE FIXTURE DRAIN FOR WASHING MACHINE SHALL BE 3IN. | | PER FBC PL 406.2 | | | | 4. THE STACK FOR THE WASHING MACHINE SHALL BE VENTED. | | PER FBC PL 901.2-901.2.1 | | | | 5. WATER SUPPLY'S FOR THE WASHING MACHINE SHALL COMPLY | | WITH FBC PL 604.9 WATER HAMMER. | | THE FLOW VELOCITY OF THE WATER DISTRIBUTION SYSTEM | | SHALL BE CONTROLLED TO REDUCE THE POSSIBILITY OF WATER | | HAMMER. A WATER-HAMMER ARRESTOR SHALL BE INSTALLED | | WHERE QUICK-CLOSING VALVES ARE UTILIZED. WATER-HAMMER | | ARRESTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE | | MANUFACTURER?S INSTRUCTIONS. WATER-HAMMER ARRESTORS | | SHALL CONFORM TO ASSE 1010. 6. | | | | 6. A MINIMUM OF 1 VENT SHALL EXTEND THROUGH THE ROOF. | | PER FBC PL 904.1 REQUIRED VENT EXTENSION. | | THE VENT SYSTEM SERVING EACH BUILDING DRAIN SHALL HAVE | | NOT LESS THAN ONE VENT PIPE THAT EXTENDS TO THE | | OUTDOORS. | | | | 7. THE FIXTURE BRANCH FOR THE TOILET SHALL BE A MINIMUM | | OF 3IN. PER FBC PL 420.3 | | | | 8. THE HOT WATER SYSTEM SHALL COMPLY WITH FBC PL | | 607.3 THERMAL EXPANSION CONTROL. | | A MEANS OF CONTROLLING INCREASED PRESSURE CAUSED BY | | THERMAL EXPANSION SHALL BE PROVIDED WHERE REQUIRED IN | | ACCORDANCE WITH SECTIONS 607.3.1 AND 607.3.2 | | AND | | 607.2 HOT OR TEMPERED WATER SUPPLY TO FIXTURES. | | THE DEVELOPED LENGTH OF HOT OR TEMPERED WATER PIPING, | | FROM THE SOURCE OF HOT WATER TO THE FIXTURES THAT | | REQUIRE HOT OR TEMPERED WATER, SHALL NOT EXCEED 50 FEET | | (15 240 MM). RECIRCULATING SYSTEM PIPING AND | | HEAT-TRACED PIPING SHALL BE CONSIDERED TO BE SOURCES OF | | HOT OR TEMPERED WATER. | | | | 9. SHOW PIPE SIZES ON THE PIPING FOR THE BATHROOM | | GROUP. WPB AMEND TO FBC 107.2.1 | | | | 10. SHOW PIPE SIZES ON THE PIPING FOR THE WATER RISER. | | WPB AMEND TO FBC 107.2.1 | | | | 11. SHOW THE COLD WATER MAIN AND SHUT OFF ON THE WATER | | RISER | | . WPB AMEND TO FBC 107.2.1 | | | | DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND | | THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON | | RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS. | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | | | | | | | | |
|
|