Plan Review Details - Permit 16080089
Plan Review Stops For Permit 16080089 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2016-08-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-08-05 |
Time |
11:35 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-08-05 |
Time |
11:35 |
Sent To |
HIST |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2016-08-15 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-08-15 |
Time |
17:41 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-08-15 |
Time |
17:35 |
Sent To |
M |
|
Notes |
2016-08-15 17:41:15 | REVIEW 2014 5TH FBC ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | | | | | - PASSED WITH THE FOLLOWING PROVISO. [ RED LINED ON | | PLANS ] | | | | - NEC 210.63 HVAC EQUIPMENT SERVICE OUTLET. A 125 VOLT, | | SINGLE-PHASE, 15 OR 20-AMPERE-RATED RECEPTACLE OUTLET | | SHALL BE INSTALLED AT AN ACCESSIBLE LOCATION FOR THE | | SERVICING OF HVAC EQUIPMENT. THE RECEPTACLE SHALL BE | | LOCATED WITHIN 25 FT. OF THE EQUIPMENT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-08-04 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-08-04 |
Time |
10:41 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-08-04 |
Time |
10:23 |
Sent To |
B |
|
Notes |
2016-08-04 10:41:00 | REVIEW 2014 5TH FBC ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | | | | | - PROVIDE A SITE SPECIFIC PLAN SHOWING A/C DISCONNECT | | WITHIN SIGHT FOR BOTH INDOOR AND OUTDOOR UNITS PER NEC | | 440 | | | | - NEC 210.63 HVAC EQUIPMENT SERVICE OUTLET. A 125 VOLT, | | SINGLE-PHASE, 15 OR 20-AMPERE-RATED RECEPTACLE OUTLET | | SHALL BE INSTALLED AT AN ACCESSIBLE LOCATION FOR THE | | SERVICING OF HVAC EQUIPMENT. THE RECEPTACLE SHALL BE | | LOCATED WITHIN 25 FT. OF THE EQUIPMENT. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-08-19 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2016-08-19 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2016-08-12 |
Time |
10:31 |
Sent To |
|
|
Notes |
2016-08-15 10:31:58 | RESUB ROUTED TO MVALDES |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-08-05 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2016-08-05 |
Time |
14:08 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2016-08-02 |
Time |
13:03 |
Sent To |
|
|
Notes |
2016-08-03 19:07:04 | ROUTED TO MARIO V. 8/3/2016 JDV | 2016-08-03 13:03:37 | ROUTED TO MECHANICAL INBOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2016-08-18 |
|
|
Cont ID |
|
Sent By |
jvalido |
Date |
2016-08-18 |
Time |
16:06 |
Rev Time |
0.00 |
Received By |
jvalido |
Date |
2016-08-18 |
Time |
16:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-08-03 |
|
|
Cont ID |
|
Sent By |
jvalido |
Date |
2016-08-03 |
Time |
18:59 |
Rev Time |
0.00 |
Received By |
jvalido |
Date |
2016-08-03 |
Time |
18:50 |
Sent To |
|
|
Notes |
2016-08-03 18:59:46 | CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA | | BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION | | | | 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1 | | INFORMATION ON CONSTRUCTION DOCUMENTS | | | | (1) PROVIDE LOCATION OF WHERE MINI-SPLIT AHU IS | | LOCATED. | | | | FLORIDA ENERGY CODE FBC 2014 | | | | R101.4.5 CHANGE IN SPACE CONDITIONING. | | ANY NONCONDITIONED SPACE THAT IS ALTERED TO BECOME | | CONDITIONED SPACE SHALL BE REQUIRED TO BE BROUGHT INTO | | FULL COMPLIANCE WITH THIS CODE. | | | | R405.4 DOCUMENTATION. | | DOCUMENTATION OF THE SOFTWARE USED FOR THE PERFORMANCE | | DESIGN AND THE PARAMETERS FOR THE BUILDING SHALL BE IN | | ACCORDANCE WITH SECTIONS R405.4.1 THROUGH R405.4.3. | | | | (2) PROVIDE HEAT LOAD CALCULATIONS MANUAL J | | | | (3) PROVIDE ENERGY CALCULATIONS FORM R405-2014 | | | | (4) PROVIDE EXHAUST FOR BATHROOM | | | | JORGE VALIDO | | WPB MECHANICAL INSPECTOR/PLANS EXAMINER | | [email protected] | | 561-805-6716 | | |
|
|
|