Plan Review Stops For Permit 16071217 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2016-12-06 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-12-06 |
Time |
09:44 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-12-06 |
Time |
09:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-08-15 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-08-15 |
Time |
06:57 |
Rev Time |
|
Received By |
jwitmer |
Date |
2016-08-15 |
Time |
|
Sent To |
|
|
Notes |
2016-08-15 06:57:04 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 16071217 | | ADD: 505 BANYAN ST./ COUNTY PARKING GARAGE | | CONT: CARRICK | | TEL: 561-844-5322 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: MON. AUGUST 15/ 2016 | | ACTION: DENIED | | | | 1) PLANS SUBMITTED FROM JOBY L. BALINT AR 0016653 | | APPEAR TO BE PLANS THAT WERE SHRUNK NOT TO SCALE. 2014 | | FLORIDA BUILDING CODE W 2014 WEST PALM BEACH AMENDMENTS | | TO THE FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION | | 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS | | SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON | | SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. | | THE BUILDING OFFICIAL MAY ESTABLISH THROUGH | | DEPARTMENTAL POLICY, OTHER STANDARDS FOR PLANS AND | | SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO ITS | | RECORD RETENTION PROGRAM. | | | | 2) PLANS SUBMITTED FROM JOBY L. BALINT AR 0016653 ARE | | NOT SIGNED NOR SEALED. FL ADMIN CODE 61G16.003 | | ARCHITECTS PLANS ARE TO BE SIGNED WITH A FULL SIGNATURE | | FROM THE ARCHITECT OF RECORD PER 481.221 WITH A MINIMUM | | OF FIRST AND LAST NAME AS SHOWN ON THE ARCHITECTS' | | LICENSE, FAC 61G1-16.003. | | | | 3) PLEASE NOTE THE SUBMITTALS/ ENERGY DOCUMENTS WERE | | SUBMITTED FOR THE STATE APPROVED PLANS NO. 16-089 | | PAR-KUT INTERNATIONAL BUT NO APPROVED PLANS!!!! | | | | 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | THIS REVIEW. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2016-11-16 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-11-16 |
Time |
10:58 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-11-16 |
Time |
10:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-08-01 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-08-01 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-08-01 |
Time |
14:08 |
Sent To |
|
|
Notes |
2016-08-01 14:35:01 | REVIEW 2014 5TH FBC ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | | | 1) FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS | | SHALL BE SUBMITTED WHEN APPROVED BY THE BUILDING | | OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL | | CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT | | LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED | | BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND | | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM | | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, | | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE | | TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC, | | AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE | | OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | SECTION 107.3.5). | | | | 2) FBC-107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING | | PLANS SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON | | SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. | | THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, | | SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO | | RECORDS MANAGEMENT | | | | 3) NEC 215.5 PROVIDE A DIAGRAM SHOWING FEEDER ROUTING, | | SERVICE RISER DIAGRAM TO SHOW POWER SOURCE FROM UTILITY | | SERVICE. | | | | 4) FBC-E C405.7.3 VOLTAGE DROP. FEEDERS & CUSTOMER | | OWNED SERVICE CONDUCTORS SHALL BE SIZED FOR A MAXIMUM | | OF 2% VOLTAGE DROP. BRANCH CIRCUITS SHALL BE SIZED FOR | | A MAXIMUM OF 3% VOLTAGE DROP. | | | | 5) PROVIDE AIC RATING OF OCPD AND ELECTRICAL EQUIPMENT | | NEC 110.9 & 110.10, FPL LETTER MIGHT BE REQUIRED TO | | VERIFY AVAILABLE FAULT CURRENT NEC 110.24(A) | | | | 6) OUTDOOR ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN | | SUITABLE ENCLOSURES AND SHALL BE PROTECTED FROM | | ACCIDENTAL CONTACT BY UNAUTHORIZED PERSONNEL, OR BY | | VEHICULAR TRAFFIC, OR BY ACCIDENTAL SPILLAGE OR LEAKAGE | | FROM PIPING SYSTEMS. IF APPLICABLE PLEASE PROVIDE | | PROPER GUARDING NEC 110.27 | | | | ADDITIONAL COMMENTS MAY BE ADDED ON THE NEXT SUBMITTAL | | IF NECCESSARY. | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2016-11-22 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-11-22 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-11-22 |
Time |
16:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2016-08-08 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-08-08 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-08-08 |
Time |
16:51 |
Sent To |
|
|
Notes |
2016-08-08 17:05:55 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | FIRE DOES NOT HAVE AN OBJECTION TO THE PROPOSED; | | HOWEVER, IT WILL NOT BE REVIEW STAMPED BASED ON THE | | BELOW COMMENT. | | | | 1) FOUR (4) PLAN SHEETS WERE SUBMITTED; HOWEVER, TWO | | (2) SHEETS APPEAR TO HAVE MATCHING PAPERWORK AND TWO | | (2) SHEETS DO NOT. WHICH PLAN SETS ARE CORRECT? | | | | PLEASE REVIEW AND CORRECT/CLARIFY AND PROVIDE MATCHING | | PAPERWORK FOR ALL FOUR (4) SHEETS. | | | | | | 2) WILL THERE BE FIRE EXTINGUISHERS PROVIDED IN OR | | AROUND EACH BOOTH? | | | | PLEASE INDICATE WITH A NOTE THE NEAREST FE WITHIN THE | | GARAGE OR PROVIDE ONE AT THE CENTER BOOTH. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-12-22 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2016-12-22 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2016-11-09 |
Time |
12:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-08-26 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-08-26 |
Time |
07:34 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2016-07-29 |
Time |
11:38 |
Sent To |
|
|
Notes |
2016-08-25 11:28:22 | TO LMERCHANT | 2016-07-29 11:38:10 | C11 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2016-11-18 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-11-18 |
Time |
16:35 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-11-18 |
Time |
16:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-08-04 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-08-04 |
Time |
07:55 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-08-04 |
Time |
07:55 |
Sent To |
|
|
Notes |
2016-08-04 08:03:00 | 1ST REVIEW FBC-2014 MECHANICAL, ENERGY CONSERVATION | | PERMIT #16071217 | | 8/3/16 | | | | 1) SUBMIT ORIGINAL PLANS FOR ALL SITE-RELATED WORK ON | | THE PROJECT INCLUDING FOUNDATION DETAILS, ELECTRICAL | | AND MECHANICAL CONNECTIONS ETC.- SEE FLORIDA STAUTES | | 553.38. ALL SUBMITTED SITE RELATED PLANS SHALL BEAR THE | | ORIGINAL SIGNATURE AND SEAL OF THE DESIGN PROFESSIONAL | | PER FLORIDA STATURE AND FAC 61G15. | | SEE ALSO SECTION 107.1 WPB AMENDMEMTS TO THE FBC: | | FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF | | CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL | | INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL | | BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT | | APPLICATION. THE CONSTRUCTION DOCUMENTS SHALL BE | | PREPARED BY A REGISTERED DESIGN PROFESSIONAL WHERE | | REQUIRED BY CHAPTER 471, FLORIDA STATUTES& 61G15 | | FLORIDA ADMINISTRATIVE CODE OR CHAPTER 481, FLORIDA | | STATUTES & 61G1 FLORIDA ADMINISTRATIVE CODE. WHERE | | SPECIAL CONDITIONS EXIST, THE BUILDING OFFICIAL IS | | AUTHORIZED TO REQUIRE ADDITIONAL CONSTRUCTION DOCUMENTS | | TO BE PREPARED BY A | | REGISTERED DESIGN PROFESSIONAL. ELECTRONIC MEDIA | | DOCUMENTS SHALL BE SUBMITTED WHEN REQUIRED BY THE | | BUILDING OFFICIAL, AND MAY REQUIRE ONLY ONE SET OF | | SUBMITTALS. | | | | 2) PROVIDE AC PLANS AND COOLING AND HEATING | | CALCULATIONS IN COMPLIANCE WITH SECTION C403.2.1 FBC-14 | | ENERGY CONSERVATION. | | | | 3) PLEASE NOTE SITE SPECIFIC WIND LOAD ENGINEERING IS | | REQUIRED FOR ALL EXTERIOR MECHANICAL EQUIPMENT | | INSTALLATIONS- SECTION 301.15. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2016-11-29 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-11-29 |
Time |
17:19 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-11-29 |
Time |
17:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2016-08-24 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-08-24 |
Time |
04:22 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-08-24 |
Time |
04:09 |
Sent To |
|
|
Notes |
2016-08-24 04:19:20 | SECTION 403.3.3 OF THE 2014 FBC-PLUMBING REQUIRES | | SANITARY FACILITIES TO BE ON A PATH OF TRAVEL NOT TO | | EXCEED A DISTANCE OF 500 FEET. INDICATE ON THE SITE | | PLAN THAT SANITARY FACILITIES ARE WITHIN A DISTANCE OF | | 500 FEET OF THESE TICKET BOOTHS. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2016-12-22 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2016-12-22 |
Time |
14:23 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2016-12-22 |
Time |
14:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2016-08-25 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2016-08-25 |
Time |
11:28 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2016-08-25 |
Time |
11:28 |
Sent To |
|
|
Notes |
|
|