Plan Review Stops For Permit 16070884 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2017-01-23 |
|
|
Cont ID |
|
Sent By |
|
Date |
2017-01-23 |
Time |
|
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-01-23 |
Time |
16:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2016-11-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-11-30 |
Time |
08:31 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-11-30 |
Time |
07:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2016-08-11 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-08-11 |
Time |
11:27 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-08-11 |
Time |
10:35 |
Sent To |
|
|
Notes |
2016-08-11 11:27:14 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 16070084 | | ADD: 770 NORTHPOINT PARKWAY SUITE 102 | | CONT: LEIGHTON MCGINN | | TEL: 561-902-4046 | | E-MAIL: PHILIP @LMCGC.COM | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: THURS. AUGUST 11/ 2016 | | ACTION: BUILDING PROVISO | | | | 1) SHEET A-2 DETAIL A, KITCHENETTE. MICROWAVE NOR | | CONCECTION OVEN WILL BE ABLE TO BE PLACED ON THE SHELF | | WITH ELECTRICAL OUTLET. | | 2014 FBC-ACCESSIBILITY CODE REACH RANGES 308.2 & 308.3 | | 309.1-4 OPERABLE PARTS | | | | 2) SHEET A-2 DETAIL, RECEPTION DESK. AS BUILT | | REQUIREDSHOW COMPLIANCE WITH: 2014 FBC-ACCESS. CODE | | 904.4 SALES AND SEERVICE COUNTERS, | | 904.4.1. PARALLEL APPROACH | | OR | | 904.4.2. FORWARD APPROACH | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2017-02-08 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2017-02-08 |
Time |
11:40 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2017-02-08 |
Time |
11:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2016-12-08 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-12-08 |
Time |
16:38 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-12-08 |
Time |
15:17 |
Sent To |
|
|
Notes |
2016-12-08 16:40:11 | 2ND REVIEW 2014 5TH FBC ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | | | | | PASSED WITH THE FOLLOWING PROVISO | | | | 1] NEC 700.12 (F) (4) ? EMERGENCY/EXIT LIGHTING SHALL | | BE FED BY LIGHTING CIRCUIT OF SAME LOCAL AREA. *IF 3 OR | | MORE LIGHTING CIRCUITS SUPPLY THE AREA, EM LIGHTS MAY | | BE ON OWN CIRCUIT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-08-08 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-08-08 |
Time |
14:12 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-08-08 |
Time |
11:35 |
Sent To |
|
|
Notes |
2016-08-08 14:14:26 | JOB PERMIT NUMBER: 16070884 | | JOB ADDRESS: 770 NORTHPOINT PARKWAY | | WEST PALM BEACH FLORIDA SUITE # 102 | | DATE: AUGUST 8, 2016 | | ELECTRICAL PLAN REVIEW COMMENTS | | | | THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION | | HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF | | THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC, | | (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST | | PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF | | SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED. | | | | 1) CLARIFY IF ELECTRICAL POLES FOR CUBICLES ARE | | EXISTING? IF NOT PROVIDE MANUFACTURE SPECS. FBC 107 | | MINIMUM PLAN REVIEW | | 2) IF HAND DRYER OUTLET IS CORD AND PLUG CONNECTED THE | | RECEPTACLE SHALL BE GFCI PROTECTED. NEC 210(B)(1) | | 3) ADD EMERGENCY LIGHTING TO CUBICLE AREA FBC-1006.2. | | ILLUMINATION FOR THE MEANS OF EGRESS SHALL NOT BE LESS | | THAN 1' CANDLE AT THE WALKING SURFACE. | | 4) NEC 700.12 (F) (4) ? EMERGENCY/EXIT LIGHTING SHALL | | BE FED BY LIGHTING CIRCUIT OF SAME LOCAL AREA. *IF 3 OR | | MORE LIGHTING CIRCUITS SUPPLY THE AREA, EM LIGHTS MAY | | BE ON OWN CIRCUIT. | | 5) PROVIDE MANDATORY LIGHTING CONTROLS FOR CUBICLE AREA | | FBC-E SECTION C405.2 | | 5A) FBC-E SECTION C405.2.1.2 LIGHTING REDUCTION | | 5B) FBC-E SECTION C405.2.2.1 AUTOMATIC TIME SWITCH | | 5C) FBC-E SECTION C405.2.2.3 DAYLIGHT ZONE CONTROL | | 5D) FBC-E SECTION C405.3 TANDEM WIRING | | 6) NEC 410.36(B) SUSPENDED CEILING SHALL BE SECURELY | | ATTACHED TO THE BUILDING STRUCTURE AND LUMINAIRES | | FASTENED TO THE CEILING GRID FRAMING MEMBERS BY | | MECHANICAL MEANS, PLEASE VERIFY ANSI STANDARDS FOR FIRE | | RATED ASSEMBLY LOAD CAPACITY. PROVIDE A SUPPORTING | | DETAIL OR ADD A BLOCK NOTE. | | 7) FBC-E C405.7 AT THE LEAST 50% OF ALL 125-VOLT, 15- | | AND 20-AMPERE RECEPTACLES SHALL BE AUTOMATICALLY | | CONTROLLED WHERE INSTALLED IN PRIVATE OFFICES, OPEN | | OFFICES, AND COMPUTER CLASSROOMS. THIS INCLUDES THOSE | | INSTALLED IN MODULAR PARTITIONS. | | | | PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE | | MENTIONED DEFICIENCIES. WHEN RESUBMITTING, FOR A | | QUICKER RETURN ON YOUR RE-SUBMITTAL, YOU ARE REQUIRED | | TO PROVIDE A RESPONSE LETTER (NARRATIVE) ADDRESSING | | EACH ITEM ALONG WITH THE STANDARD CITY RE-SUBMITTAL | | FORM. | | THE NARRATIVE SHOULD INCLUDE THE PLAN REVIEWER'S | | COMMENTS AND YOUR RESPONSE OR ACTION TO SAME. | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO THE | | SUBMITTAL AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | COMPARISON. | | CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED. IF | | YOU HAVE FURTHER QUESTIONS, PLEASE DON'T HESITATE TO | | CONTACT ME DIRECTLY. | | | | FBC 2014 5TH ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2017-01-23 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-01-23 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-01-20 |
Time |
16:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2016-12-02 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2016-12-02 |
Time |
12:45 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2016-12-02 |
Time |
12:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2016-08-10 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2016-08-10 |
Time |
12:32 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2016-08-10 |
Time |
12:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2017-02-08 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2017-02-08 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2017-02-08 |
Time |
11:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-01-03 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-01-03 |
Time |
08:20 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-12-28 |
Time |
14:50 |
Sent To |
|
|
Notes |
2016-12-29 14:50:29 | RESUB ROUTED TO CCOLE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-12-13 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-12-13 |
Time |
12:35 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-11-22 |
Time |
07:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-08-22 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-08-22 |
Time |
10:46 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-07-22 |
Time |
11:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
N |
Date |
2017-01-30 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-01-30 |
Time |
14:03 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-01-30 |
Time |
14:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2017-01-03 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-01-03 |
Time |
08:15 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-01-03 |
Time |
08:15 |
Sent To |
|
|
Notes |
2017-01-03 08:18:21 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #16070884 | | 1/3/17 | | | | 1) AS PREVIOUSLY REQUESTED PROVIDE A SCOPE OF WORK ON | | THE PLANS, AND MINIMUM VENTILATION CALCULATIONS. | | | | 2) THE AC PLAN MUST BEAR THE NAME AND SIGNATURE OF THE | | PERSON RESPONSIBLE FOR THE DESIGN- SECTION 107.2.1 WPB | | AMENDMENTS TO THE FBC. | | | | 3) PROVIDE THE SUPPLY DUCT SIZES IN OFFICES #1, 4, 5 * | | 6. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2016-12-01 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-12-01 |
Time |
09:00 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-12-01 |
Time |
09:00 |
Sent To |
|
|
Notes |
2016-12-01 09:03:38 | 2ND REVIEW FBC-2014 MECHANICAL | | PERMIT #16070884 | | 12/1/16 | | | | 1) 2ND REQUEST FOR MECHANICAL PLANS- SEE 1ST REVIEW | | COMMENT PRINTED BELOW AND COMPLY. | | | | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #16070884 | | 8/11/16 | | | | 1) SUBMIT MECHANICAL PLANS FOR THE PROPOSED TENANT | | REMODEL INCLUDING BUT NOT LIMITED TO: | | | | A) SCOPE OF WORK FOR MECHANICAL DEMOLITION AND | | ALTERATIONS. | | | | B) EXISTING AND NEW HVAC EQUIPMENT SCHEDULES. | | | | C) DUCT LAYOUT PLAN INDICATING NEW, EXISTING, AND | | RELOCATED DUCTS, DIFFUSERS AND RETURN GRILLS. | | | | D) MINIMUM VENTILATION CALCULATIONS FOR ALL ROOMS AND | | SPACES. | | | | E) AIR DISTRIBUTION AND DEVICE SCHEDULES. | | | | 2) PLEASE NOTE AC LOAD CALCULATIONS MAY BE REQUIRED FOR | | NEW AC SYSTEMS, AND ADDITIONAL COMMENTS MAY OCCUR | | PENDING REVIEW OF CORRECTED PLANS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-08-11 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-08-11 |
Time |
17:25 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-08-11 |
Time |
17:25 |
Sent To |
|
|
Notes |
2016-08-11 17:27:47 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #16070884 | | 8/11/16 | | | | 1) SUBMIT MECHANICAL PLANS FOR THE PROPOSED TENANT | | REMODEL INCLUDING BUT NOT LIMITED TO: | | | | A) SCOPE OF WORK FOR MECHANICAL DEMOLITION AND | | ALTERATIONS. | | | | B) EXISTING AND NEW HVAC EQUIPMENT SCHEDULES. | | | | C) DUCT LAYOUT PLAN INDICATING NEW, EXISTING, AND | | RELOCATED DUCTS, DIFFUSERS AND RETURN GRILLS. | | | | D) MINIMUM VENTILATION CALCULATIONS FOR ALL ROOMS AND | | SPACES. | | | | E) AIR DISTRIBUTION AND DEVICE SCHEDULES. | | | | 2) PLEASE NOTE AC LOAD CALCULATIONS MAY BE REQUIRED FOR | | NEW AC SYSTEMS, AND ADDITIONAL COMMENTS MAY OCCUR | | PENDING REVIEW OF CORRECTED PLANS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2017-01-26 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-01-26 |
Time |
12:50 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-01-26 |
Time |
12:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2016-12-13 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-12-13 |
Time |
12:35 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-12-13 |
Time |
12:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2016-08-22 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-08-22 |
Time |
10:46 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-08-22 |
Time |
10:33 |
Sent To |
|
|
Notes |
|
|