Plan Review Details - Permit 16070884
Plan Review Stops For Permit 16070884
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2017-01-23 Cont ID  
Sent By   Date 2017-01-23 Time   Rev Time 0.00
Received By jwitmer Date 2017-01-23 Time 16:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-11-30 Cont ID  
Sent By jwitmer Date 2016-11-30 Time 08:31 Rev Time 0.00
Received By jwitmer Date 2016-11-30 Time 07:32 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2016-08-11 Cont ID  
Sent By jwitmer Date 2016-08-11 Time 11:27 Rev Time 0.00
Received By jwitmer Date 2016-08-11 Time 10:35 Sent To  
Notes
2016-08-11 11:27:14BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16070084
 ADD: 770 NORTHPOINT PARKWAY SUITE 102
 CONT: LEIGHTON MCGINN
 TEL: 561-902-4046
 E-MAIL: PHILIP @LMCGC.COM
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. AUGUST 11/ 2016
 ACTION: BUILDING PROVISO
  
 1) SHEET A-2 DETAIL A, KITCHENETTE. MICROWAVE NOR
 CONCECTION OVEN WILL BE ABLE TO BE PLACED ON THE SHELF
 WITH ELECTRICAL OUTLET.
 2014 FBC-ACCESSIBILITY CODE REACH RANGES 308.2 & 308.3
 309.1-4 OPERABLE PARTS
  
 2) SHEET A-2 DETAIL, RECEPTION DESK. AS BUILT
 REQUIREDSHOW COMPLIANCE WITH: 2014 FBC-ACCESS. CODE
 904.4 SALES AND SEERVICE COUNTERS,
 904.4.1. PARALLEL APPROACH
 OR
 904.4.2. FORWARD APPROACH
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2017-02-08 Cont ID  
Sent By vperez Date 2017-02-08 Time 11:40 Rev Time 0.00
Received By vperez Date 2017-02-08 Time 11:40 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-12-08 Cont ID  
Sent By mvaldes Date 2016-12-08 Time 16:38 Rev Time 0.00
Received By mvaldes Date 2016-12-08 Time 15:17 Sent To  
Notes
2016-12-08 16:40:112ND REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
  
 PASSED WITH THE FOLLOWING PROVISO
  
 1] NEC 700.12 (F) (4) ? EMERGENCY/EXIT LIGHTING SHALL
 BE FED BY LIGHTING CIRCUIT OF SAME LOCAL AREA. *IF 3 OR
 MORE LIGHTING CIRCUITS SUPPLY THE AREA, EM LIGHTS MAY
 BE ON OWN CIRCUIT.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-08-08 Cont ID  
Sent By mvaldes Date 2016-08-08 Time 14:12 Rev Time 0.00
Received By mvaldes Date 2016-08-08 Time 11:35 Sent To  
Notes
2016-08-08 14:14:26JOB PERMIT NUMBER: 16070884
 JOB ADDRESS: 770 NORTHPOINT PARKWAY
 WEST PALM BEACH FLORIDA SUITE # 102
 DATE: AUGUST 8, 2016
  ELECTRICAL PLAN REVIEW COMMENTS
  
 THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION
 HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF
 THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC,
 (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST
 PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF
 SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED.
  
 1) CLARIFY IF ELECTRICAL POLES FOR CUBICLES ARE
 EXISTING? IF NOT PROVIDE MANUFACTURE SPECS. FBC 107
 MINIMUM PLAN REVIEW
 2) IF HAND DRYER OUTLET IS CORD AND PLUG CONNECTED THE
 RECEPTACLE SHALL BE GFCI PROTECTED. NEC 210(B)(1)
 3) ADD EMERGENCY LIGHTING TO CUBICLE AREA FBC-1006.2.
 ILLUMINATION FOR THE MEANS OF EGRESS SHALL NOT BE LESS
 THAN 1' CANDLE AT THE WALKING SURFACE.
 4) NEC 700.12 (F) (4) ? EMERGENCY/EXIT LIGHTING SHALL
 BE FED BY LIGHTING CIRCUIT OF SAME LOCAL AREA. *IF 3 OR
 MORE LIGHTING CIRCUITS SUPPLY THE AREA, EM LIGHTS MAY
 BE ON OWN CIRCUIT.
 5) PROVIDE MANDATORY LIGHTING CONTROLS FOR CUBICLE AREA
 FBC-E SECTION C405.2
 5A) FBC-E SECTION C405.2.1.2 LIGHTING REDUCTION
 5B) FBC-E SECTION C405.2.2.1 AUTOMATIC TIME SWITCH
 5C) FBC-E SECTION C405.2.2.3 DAYLIGHT ZONE CONTROL
 5D) FBC-E SECTION C405.3 TANDEM WIRING
 6) NEC 410.36(B) SUSPENDED CEILING SHALL BE SECURELY
 ATTACHED TO THE BUILDING STRUCTURE AND LUMINAIRES
 FASTENED TO THE CEILING GRID FRAMING MEMBERS BY
 MECHANICAL MEANS, PLEASE VERIFY ANSI STANDARDS FOR FIRE
 RATED ASSEMBLY LOAD CAPACITY. PROVIDE A SUPPORTING
 DETAIL OR ADD A BLOCK NOTE.
 7) FBC-E C405.7 AT THE LEAST 50% OF ALL 125-VOLT, 15-
 AND 20-AMPERE RECEPTACLES SHALL BE AUTOMATICALLY
 CONTROLLED WHERE INSTALLED IN PRIVATE OFFICES, OPEN
 OFFICES, AND COMPUTER CLASSROOMS. THIS INCLUDES THOSE
 INSTALLED IN MODULAR PARTITIONS.
  
 PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE
 MENTIONED DEFICIENCIES. WHEN RESUBMITTING, FOR A
 QUICKER RETURN ON YOUR RE-SUBMITTAL, YOU ARE REQUIRED
 TO PROVIDE A RESPONSE LETTER (NARRATIVE) ADDRESSING
 EACH ITEM ALONG WITH THE STANDARD CITY RE-SUBMITTAL
 FORM.
 THE NARRATIVE SHOULD INCLUDE THE PLAN REVIEWER'S
 COMMENTS AND YOUR RESPONSE OR ACTION TO SAME.
 ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO THE
 SUBMITTAL AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR
 COMPARISON.
 CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED. IF
 YOU HAVE FURTHER QUESTIONS, PLEASE DON'T HESITATE TO
 CONTACT ME DIRECTLY.
  
 FBC 2014 5TH ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2017-01-23 Cont ID  
Sent By pleduc Date 2017-01-23 Time   Rev Time 0.00
Received By pleduc Date 2017-01-20 Time 16:45 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2016-12-02 Cont ID  
Sent By wjolin Date 2016-12-02 Time 12:45 Rev Time 0.00
Received By wjolin Date 2016-12-02 Time 12:41 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2016-08-10 Cont ID  
Sent By wjolin Date 2016-08-10 Time 12:32 Rev Time 0.00
Received By wjolin Date 2016-08-10 Time 12:32 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2017-02-08 Cont ID  
Sent By vperez Date 2017-02-08 Time 11:41 Rev Time 0.00
Received By vperez Date 2017-02-08 Time 11:41 Sent To  
Notes
2017-01-19 13:41:11B10

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-01-03 Cont ID  
Sent By ccole Date 2017-01-03 Time 08:20 Rev Time 0.00
Received By ccole Date 2016-12-28 Time 14:50 Sent To  
Notes
2016-12-29 14:50:29RESUB ROUTED TO CCOLE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-12-13 Cont ID  
Sent By gjohnson Date 2016-12-13 Time 12:35 Rev Time 0.00
Received By gjohnson Date 2016-11-22 Time 07:55 Sent To  
Notes
2016-11-23 07:55:18B03

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-08-22 Cont ID  
Sent By tklarge Date 2016-08-22 Time 10:46 Rev Time 0.00
Received By tklarge Date 2016-07-22 Time 11:10 Sent To  
Notes
2016-07-22 11:11:27B14

Review Stop M MECHANICAL (A/C)
Rev No 4 Status N Date 2017-01-30 Cont ID  
Sent By ccole Date 2017-01-30 Time 14:03 Rev Time 0.00
Received By ccole Date 2017-01-30 Time 14:03 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2017-01-03 Cont ID  
Sent By ccole Date 2017-01-03 Time 08:15 Rev Time 0.00
Received By ccole Date 2017-01-03 Time 08:15 Sent To  
Notes
2017-01-03 08:18:211ST REVIEW FBC-2014 MECHANICAL
 PERMIT #16070884
 1/3/17
  
 1) AS PREVIOUSLY REQUESTED PROVIDE A SCOPE OF WORK ON
 THE PLANS, AND MINIMUM VENTILATION CALCULATIONS.
  
 2) THE AC PLAN MUST BEAR THE NAME AND SIGNATURE OF THE
 PERSON RESPONSIBLE FOR THE DESIGN- SECTION 107.2.1 WPB
 AMENDMENTS TO THE FBC.
  
 3) PROVIDE THE SUPPLY DUCT SIZES IN OFFICES #1, 4, 5 *
 6.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2016-12-01 Cont ID  
Sent By ccole Date 2016-12-01 Time 09:00 Rev Time 0.00
Received By ccole Date 2016-12-01 Time 09:00 Sent To  
Notes
2016-12-01 09:03:382ND REVIEW FBC-2014 MECHANICAL
 PERMIT #16070884
 12/1/16
  
 1) 2ND REQUEST FOR MECHANICAL PLANS- SEE 1ST REVIEW
 COMMENT PRINTED BELOW AND COMPLY.
  
 1ST REVIEW FBC-2014 MECHANICAL
 PERMIT #16070884
 8/11/16
  
 1) SUBMIT MECHANICAL PLANS FOR THE PROPOSED TENANT
 REMODEL INCLUDING BUT NOT LIMITED TO:
  
 A) SCOPE OF WORK FOR MECHANICAL DEMOLITION AND
 ALTERATIONS.
  
 B) EXISTING AND NEW HVAC EQUIPMENT SCHEDULES.
  
 C) DUCT LAYOUT PLAN INDICATING NEW, EXISTING, AND
 RELOCATED DUCTS, DIFFUSERS AND RETURN GRILLS.
  
 D) MINIMUM VENTILATION CALCULATIONS FOR ALL ROOMS AND
 SPACES.
  
 E) AIR DISTRIBUTION AND DEVICE SCHEDULES.
  
 2) PLEASE NOTE AC LOAD CALCULATIONS MAY BE REQUIRED FOR
 NEW AC SYSTEMS, AND ADDITIONAL COMMENTS MAY OCCUR
 PENDING REVIEW OF CORRECTED PLANS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-08-11 Cont ID  
Sent By ccole Date 2016-08-11 Time 17:25 Rev Time 0.00
Received By ccole Date 2016-08-11 Time 17:25 Sent To  
Notes
2016-08-11 17:27:471ST REVIEW FBC-2014 MECHANICAL
 PERMIT #16070884
 8/11/16
  
 1) SUBMIT MECHANICAL PLANS FOR THE PROPOSED TENANT
 REMODEL INCLUDING BUT NOT LIMITED TO:
  
 A) SCOPE OF WORK FOR MECHANICAL DEMOLITION AND
 ALTERATIONS.
  
 B) EXISTING AND NEW HVAC EQUIPMENT SCHEDULES.
  
 C) DUCT LAYOUT PLAN INDICATING NEW, EXISTING, AND
 RELOCATED DUCTS, DIFFUSERS AND RETURN GRILLS.
  
 D) MINIMUM VENTILATION CALCULATIONS FOR ALL ROOMS AND
 SPACES.
  
 E) AIR DISTRIBUTION AND DEVICE SCHEDULES.
  
 2) PLEASE NOTE AC LOAD CALCULATIONS MAY BE REQUIRED FOR
 NEW AC SYSTEMS, AND ADDITIONAL COMMENTS MAY OCCUR
 PENDING REVIEW OF CORRECTED PLANS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2017-01-26 Cont ID  
Sent By gjohnson Date 2017-01-26 Time 12:50 Rev Time 0.00
Received By gjohnson Date 2017-01-26 Time 12:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-12-13 Cont ID  
Sent By gjohnson Date 2016-12-13 Time 12:35 Rev Time 0.00
Received By gjohnson Date 2016-12-13 Time 12:11 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-08-22 Cont ID  
Sent By tklarge Date 2016-08-22 Time 10:46 Rev Time 0.00
Received By tklarge Date 2016-08-22 Time 10:33 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved