Plan Review Details - Permit 16070715
Plan Review Stops For Permit 16070715 |
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
P |
Date |
2016-11-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-11-19 |
Time |
08:42 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-11-19 |
Time |
08:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2016-10-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-10-05 |
Time |
08:17 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-10-05 |
Time |
08:17 |
Sent To |
|
|
Notes |
2016-10-05 08:18:08 | ADDRESS WILL BE ASSIGNED PRIOR TO PERMIT ISSUANCE. | | |
|
|
Review Stop |
AIPP |
ART IN PUBLIC PLACES |
Rev No |
1 |
Status |
P |
Date |
2016-11-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-11-22 |
Time |
16:47 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-11-22 |
Time |
16:47 |
Sent To |
|
|
Notes |
2016-11-22 16:47:31 | OK PER EMAIL FROM SYBILLE WELTER DATED 11/22/16 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2017-01-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-01-17 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-01-17 |
Time |
07:38 |
Sent To |
|
|
Notes |
2017-06-26 12:42:34 | 16070715 - BUILDING DATA FOR C.O. AND REPORTING | | USC-404 TYPE 105 - NEW:RES FIVE OR MORE UNITS | | SQUARE FEET - 641051 | | | | CONSTRUCTION TYPE: 14-1-A | | UNITS: 290 | | FLOORS: 25 | | BEDROOMS: 391 | | ROOMS: 3101 | | SQ FT LIVABLE: 641051 | | SQ FT FOOTPRINT: 38078 | | SQ FT ROOF: 38078 | | | | SETBACKS FRONT (USE THIS TO ENTER VERTICAL DATUM IF | | KNOWN): | | SETBACKS BACK (USE THIS TO ENTER FIRST FLOOR IF KNOWN): | | XX.XX | | SETBACKS LEFT (USE THIS TO ENTER SECOND FLOOR IF KNOWN: | | XX.XX | | OCC LOAD: 4837 | | PROP USE: GAR/R2/M/A | | SPRINKLER SYS? Y | | SPRK REQ'D? Y | | BATHRMS: 391 | | | | BLDG CODE: FL 2014 | | OCC CLASS: 5TH ED R-2 | 2017-01-17 14:43:45 | ****PROVISOS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | A. PROVISO: TCO AT EACH PHASE IS SUBJECT TO APPROVAL OF | | THE BUILDING OFFICIAL (OR HIS REPRESENTATIVE) AND FIRE | | DEPARTMENT, AND MAY INCLUDE ITEMS NOT WITHIN THE SCOPE | | OF THIS REVIEW. A TCO REQUEST FORM AND FEE WILL BE | | REQUIRED. THIS FORM IS AVAILABLE UPON REQUEST BY EMAIL. | | | | C. SEPARATE PERMITS (APPLICATION, PLANS, REVIEWS, AND | | FEES) REQUIRED FOR ALL ITEMS OTHER THAN MECHANICAL, | | ELECTRICAL, AND PLUMBING FOR THE BUILDING AS SHOWN ON | | THE PLANS. THIS INCLUDES SIGNS, FIRE ALARM, FIRE | | SPRINKLERS, LANDSCAPING. | | | | SUB PERMITS (APPLICATION, SUB PERMIT FEE) ARE REQUIRED | | FOR MECHANICAL, ELECTRICAL, AND PLUMBING PRIOR TO | | COMMENCEMENT OF WORK. | | | | A ROOFING SUB PERMIT IS REQUIRED PRIOR TO COMMENCEMENT | | OF ROOFING WORK. AS ROOF DOCUMENTS HAVE NOT BEEN | | PROVIDED, THIS IS A DEFERRED SUBMITTAL. PRODUCT | | APPROVALS REVIEWED BY DESIGNER OF RECORD, SELECTED | | ASSEMBLY, ENGINEERING IF APPLICABLE ARE TO BE SUBMITTED | | AS A REVISION WITH A ROOF PERMIT APPLICATION. | | | | D. COMPONENTS AND CLADDING PRODUCT APPROVALS ARE TO BE | | REVIEWED BY DESIGNER OF RECORD AND SUBMITTED PRIOR TO | | INSTALLATION. | | | | E. PROVISO, THIS STUCTURE SERVES A BUILDING WHICH HAS | | NOT BEEN REVIEWED BY THIS DEPARTMENT (TRAIN STATION). | | ACCESSIBLE ROUTE IN COMPLIANCE WITH FBC 5TH EDITION | | ACCESSIBILITY IS REQUIRED AND WILL BE VERIFIED IN THE | | FIELD. | | | | F. PROVISO, THE PROJECT MANUAL HAS NOT BEEN REVIEWED. | | DOOR HARDWARE TO COMPLY WITH FBC BUILDING, FBC | | ACCESSIBILITY. | | G. PROVISO, ALL DOORS AND GATES IN THE MEANS OF EGRESS | | FOR ASSEMBLY OCCUPANCY ARE TO INCLUDE PANIC DEVICES OR | | FIRE EXIT HARDWARE, FBC 1008. | | H. PROVISO, PRODUCT APPROVALS FOR COMPONENTS AND | | CLADDING HAVE NOT BEEN SUBMITTED. THEY MAY BE | | SUBMITTED, PRIOR TO INSTALLATION, AS A REVISION, PRIOR | | TO INSTALLATION. | | | | I. PROVISO, FLOORING UNDERLAYMENT IS TO COMPLY WITH FBC | | 1207.2, 1207.3, AND 603.1. THIS MAY BE A DEFERRED | | SUBMITTAL. IF DEFERRED, THE TEST REPORTS ARE TO BE | | SUBMITTED AS A REVISION PRIOR TO INSTALLATION. AS | | STRUCTURAL PLANS SHOW AN 8 INCH SLAB, PRODUCTS TESTED | | WITH EITHER A 6 INCH OR AN 8 INCH SLAB ARE ACCEPTABLE. | | | | 1. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. | | THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM | | CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | 2. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED | | GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | 3. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | OR UL 723. | | | | J. FBC ACCESSIBILITY 207, MEANS OF EGRESS SHALL COMPLY | | WITH IBC 2000 WITH 2001 SUPPLEMENT 1003.2.13 OR IBC | | 2003 1007. | | | | PER ARCHITECT, BOTH BANKS OF ELEVATORS (EAST SIDE AND | | WEST SIDE) WILL HAVE A MINIMUM OF ONE ELEVATOR OPERABLE | | ON STANDBY POWER. | | | | K. STANDBY POWER, FBC 403.4.8, EMERGENCY POWER 403.4.9 | | REQUIRED. | | | | L. FBC ACCESSIBILITY 208.3.1(2) ADVISORY, EV SPACE WITH | | AN ACCESS AISLE, LOCATED ON AN ACCESSIBLE ROUTE, IS | | REQUIRED. A REVISION IS TO BE SUBMITTED, REVIEWED AND | | ISSUED PRIOR TO C.O. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2016-11-23 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-11-23 |
Time |
06:50 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-11-19 |
Time |
08:42 |
Sent To |
|
|
Notes |
2016-11-23 06:50:59 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 14. SPECIFY ACCESSIBLE MEANS OF EGRESS SELECTED, FBC | | BUILDING 1007, FBC ACCESSIBILITY 207. REVISE PLAN TO | | SHOW COMPLIANCE WITH METHOD SELECTED IF ALL ITEMS ARE | | NOT IMMEDIATELY APPARENT (FOR EXAMPLE, IBC2000 ELEVATOR | | AS MEANS OF EGRESS COMPONENT). | | | | 2ND REVIEW, IT IS NOT CLEAR WHICH METHOD WAS SELECTED. | | RESPONSE STATES STAIRS ARE THE ACCESSIBLE MEANS OF | | EGRESS. | | | | APPLICABLE TO THE TRANSIT PORTION OF THIS BUILDING, SEE | | FBC 1007, ACCESSIBLE MEANS OF EGRESS SHALL BE PROVIDED | | IN ACCORDANCE WITH THE APPLICABLE SECTIONS OF THE FBC | | ACCESSIBILITY. | | | | FBC ACCESSIBILITY 207, MEANS OF EGRESS SHALL COMPLY | | WITH IBC 2000 WITH 2001 SUPPLEMENT 1003.2.13 OR IBC | | 2003 1007. | | | | YOU MAY FIND THIS SITE HELPFUL: | | | | HTTPS://WWW.ACCESS-BOARD.GOV/GUIDELINES-AND-STANDARDS/B | | UILDINGS-AND-SITES/ABOUT-THE-ADA-STANDARDS/GUIDE-TO-THE | | -ADA-STANDARDS/CHAPTER-4-ACCESSIBLE-MEANS-OF-EGRESS?TMP | | L=COMPONENT&PAGE= | | | | REVISE PLAN TO CLARIFY COMPLIANCE. | | | | 15. A200 REGARDING SIGNAGE ITEM 2; CLARIFY ACCESSIBLE | | MEANS OF EGRESS SELECTED AND REVISE NOTE IF APPLICABLE. | | | | RESPONSE STATES REVISION IS NOT NECESSARY; THIS ITEM | | NOT REVIEWED AT THIS TIME PENDING RESPONSE TO ITEM 14. | | | | 16 - 26, OK. | | | | 27. SEE PLUMBING COMMENTS REGARDING ACCESSIBILITY AND | | FAIR HOUSING AND REVISE PLAN TO SHOW COMPLIANCE. | | DISREGARD IF COMMENT IS NOT APPLICABLE. | | | | 28 - 31. OK | | | | | | 32. REVISE PLAN TO SHOW THE 18IN MANEUVERING CLEARANCE, | | PULL SIDE (FBC ACCESSIBILITY 404.2.4), DOOR LOCATED ON | | SHEET A301, DOOR R03H (FBC 5TH ED. ACCESSIBILITY | | 206.4.5), OR OTHERWISE INDICATE THAT THIS WILL NOT BE | | THE ONLY DOOR SERVING A TENANT SPACE, OR PROVIDE AN | | OPENER. | | | | 2ND REVIEW, THIS WAS DISCUSSED, BUT IT IS NOT CLEAR HOW | | THIS WAS ADDRESSED. PLAN HAS BEEN REDLINED (18IN | | REQUIRED), AND WHEN SCALED APPEARS COMPLIANT. NO ACTION | | REQUIRED UNLESS THIS SHEET IS REVISED FOR OTHER | | REASONS. | | | | 33 - 40. OK | | | | 41. STANDBY POWER, FBC 403.4.8, EMERGENCY POWER 403.4.9 | | REQUIRED. | | | | 2ND REVIEW, THE SPECIFICATION BOOK WAS NOT REVIEWED AND | | IS CONSIDERED SUPPLEMENTARY TO THE PLANS. THIS ITEM | | WILL BE A PROVISO BUT CLARIFICATION REGARDING THE | | ELEVATOR(S) REQUIRED FOR THE ACCESSIBLE MEANS OF EGRESS | | IS REQUESTED. | | | | 42-50. OK | | | | 51. SMOKE CONTROL REFERENCED, BUT REPORT NOT PROVIDED, | | FBC 909.4. | | | | SEE MECHANICAL COMMENTS AND ADDRESS ACCORDINGLY. | | | | 52. OK | | | | 53. THIS PERMIT WILL BE ISSUED WITH THE FOLLOWING | | PROVISOS: | | | | A. PROVISO: TCO AT EACH PHASE IS SUBJECT TO APPROVAL OF | | THE BUILDING OFFICIAL (OR HIS REPRESENTATIVE) AND FIRE | | DEPARTMENT, AND MAY INCLUDE ITEMS NOT WITHIN THE SCOPE | | OF THIS REVIEW. A TCO REQUEST FORM AND FEE WILL BE | | REQUIRED. THIS FORM IS AVAILABLE UPON REQUEST BY EMAIL. | | | | C. SEPARATE PERMITS (APPLICATION, PLANS, REVIEWS, AND | | FEES) REQUIRED FOR ALL ITEMS OTHER THAN MECHANICAL, | | ELECTRICAL, AND PLUMBING FOR THE BUILDING AS SHOWN ON | | THE PLANS. THIS INCLUDES SIGNS, FIRE ALARM, FIRE | | SPRINKLERS, LANDSCAPING. | | | | SUB PERMITS (APPLICATION, SUB PERMIT FEE) ARE REQUIRED | | FOR MECHANICAL, ELECTRICAL, AND PLUMBING PRIOR TO | | COMMENCEMENT OF WORK. | | | | A ROOFING SUB PERMIT IS REQUIRED PRIOR TO COMMENCEMENT | | OF ROOFING WORK. AS ROOF DOCUMENTS HAVE NOT BEEN | | PROVIDED, THIS IS A DEFERRED SUBMITTAL. PRODUCT | | APPROVALS REVIEWED BY DESIGNER OF RECORD, SELECTED | | ASSEMBLY, ENGINEERING IF APPLICABLE ARE TO BE SUBMITTED | | AS A REVISION WITH A ROOF PERMIT APPLICATION. | | | | D. COMPONENTS AND CLADDING PRODUCT APPROVALS ARE TO BE | | REVIEWED BY DESIGNER OF RECORD AND SUBMITTED AS A | | REVISION PRIOR TO INSTALLATION. | | | | E. PROVISO, THIS STUCTURE SERVES A BUILDING WHICH HAS | | NOT BEEN REVIEWED BY THIS DEPARTMENT (TRAIN STATION). | | ACCESSIBLE ROUTE IN COMPLIANCE WITH FBC 5TH EDITION | | ACCESSIBILITY IS REQUIRED AND WILL BE VERIFIED IN THE | | FIELD. | | | | F. PROVISO, THE PROJECT MANUAL HAS NOT BEEN REVIEWED. | | DOOR HARDWARE TO COMPLY WITH FBC BUILDING, FBC | | ACCESSIBILITY. | | G. PROVISO, ALL DOORS AND GATES IN THE MEANS OF EGRESS | | FOR ASSEMBLY OCCUPANCY ARE TO INCLUDE PANIC DEVICES OR | | FIRE EXIT HARDWARE, FBC 1008. | | H. PROVISO, PRODUCT APPROVALS FOR COMPONENTS AND | | CLADDING HAVE NOT BEEN SUBMITTED. THEY MAY BE | | SUBMITTED, PRIOR TO INSTALLATION, AS A REVISION, PRIOR | | TO INSTALLATION. | | | | I. PROVISO, FLOORING UNDERLAYMENT IS TO COMPLY WITH FBC | | 1207.2, 1207.3, AND 603.1. THIS MAY BE A DEFERRED | | SUBMITTAL. IF DEFERRED, THE TEST REPORTS ARE TO BE | | SUBMITTED AS A REVISION PRIOR TO INSTALLATION. AS | | STRUCTURAL PLANS SHOW AN 8 INCH SLAB, PRODUCTS TESTED | | WITH EITHER A 6 INCH OR AN 8 INCH SLAB ARE ACCEPTABLE. | | | | A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. | | THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM | | CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED | | GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | OR UL 723. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-09-15 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-09-15 |
Time |
18:00 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-08-17 |
Time |
15:43 |
Sent To |
|
|
Notes |
2016-09-15 18:01:36 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. UPDATE PLANS WITH THE CHANGES MADE TO PERMIT | | 16040755, STRUCTURE PERMIT. SOME OF THE COMMENTS IN | | THIS LIST HAVE ALREADY BEEN CORRECTED IN THE STRUCTURE | | PERMIT AND HAVE BEEN FOUND CODE COMPLIANT. | | | | 2. FOR C.O. INFORMATION, PROVIDE THE FOLLOWING: | | TOTAL NUMBER OF BEDROOMS | | TOTAL NUMBER OF BATHROOMS | | TOTAL NUMBER OF ROOMS | | | | 3. FBC TABLE 705.8. SHEET A100 SHOWS THE NORTH | | ELEVATION (PARTIAL) AS 12FT 1IN FROM THE BUILDING TO | | THE CENTER LINE OF THE ALLEY; SHEET A200 INCLUDES THE | | LIMITATION OF 45 PERCENT UNPROTECTED OPENINGS ALLOWED. | | REVISE THE PLAN TO INCLUDE THE PERCENTAGE OF | | UNPROTECTED OPENINGS FOR THIS BUILDING, NORTH | | ELEVATION. | | | | 4. A100 SITE PLAN SHOWS THE APPROX CENTER OF ALLEY. | | REVISE TO INCLUDE EXACT DIMENSION BASED ON THE SURVEY | | OR PLAT SO COMPLIANCE WITH FBC TABLE 602, 705.8 CAN BE | | DETERMINED. | | | | 5. FBC TABLE 602, BASED ON FIRE SEPARATION DISTANCE | | (CHAPTER 2), THE NORTH WALL REQUIRES A 1 HOUR RATING. | | A. REVISE TO INCLUDE ON SHEET A201 AND ALL OTHER SHEETS | | AFFECTED OR REVISE SITE PLAN ON A100 TO CLARIFY FIRE | | SEPARATION DISTANCE. | | B. REVISE DOOR SCHEDULE TO COMPLY WITH FBC TABLE 716.5 | | FOR AFFECTED DOORS. | | | | 6. FBC TABLES 601, 602, PROVIDE DETAILS FOR THE FIRE | | RATED ELEMENTS, INCLUDING THE NORTH WALL WHICH HAS A | | FIRE SEPARATION DISTANCE LESS THAN 30FT, FBC 703, 704. | | | | 7. A200, STRUCTURAL FIRE RESISTANCE RATING | | REQUIREMENTS, REVISE STRUCTURE AND ROOF REQUIREMENTS TO | | BE CONSISTENT WITH TABLE 601 OR REVISE PLAN TO INCLUDE | | APPLICABLE EXCEPTION. | | | | 8. A200, STRUCTURAL FIRE RESISTANCE RATING | | REQUIREMENTS, A TABLE FROM THE FBC WAS INCLUDED BUT | | DOES NOT INDICATE HOW THE TABLE APPLIES TO THIS | | PROJECT. REVISE TO INCLUDE THE WALLS AFFECTED, FBC | | TABLE 602, FBC 107. | | | | 9. FBC 403.5.3 AND 403.5.3(1), REVISE PLAN TO CLARIFY | | PROPOSED EXIT STAIR DOOR OPERATION (OR ADVISE WHERE | | THIS INFORMATION CAN BE FOUND). | | | | 10. A200 SPECIFIES BOTH OCCUPANCY SEPARATION AND NON | | SEPARATED OCCUPANCIES. REVISE PLAN TO CLARIFY WHICH OF | | THE TWO METHODS IS PROPOSED, FBC 508. THIS INFORMATION | | IS ALSO REQUIRED FOR THE TENANT BUILD OUTS, FBC 107. | | | | 11. A200 OCCUPANCY SEPARATION REFERS TO ASSEMBLY WITHIN | | EDUCATIONAL OCCUPANCIES (NOTE 1), REMOVE THIS AND OTHER | | NOTES WHICH DO NOT APPLY TO THIS PROJECT, OR CLARIFY | | WHERE THIS IS OR MAY BE APPLICABLE. | | | | 12. A200 OCCUPANCY CLASSIFICATION INCLUDES A1 THEATER; | | ADVISE WHERE THIS CAN BE LOCATED, OR IS THIS A FUTURE | | IMPROVEMENT? FBC 107. REMOVE IF NOT APPLICABLE. | | | | 13. A200 AND OTHER PAGES, FIRE RESISTANCE REQUIREMENTS | | WALLS, ITEM C, IS NOT CLEAR WHERE THIS IS APPLICABLE. | | REVISE TO REFLECT THE REQUIREMENT FOR THIS PROJECT. IT | | WOULD BE HELPFUL IF THE ACTUAL FIRE RATING REQUIREMENTS | | SPECIFIC TO THIS PROJECT WERE INCORPORATED INTO THIS | | TABLE (SUGGESTED, NOT REQUIRED). | | | | 14. SPECIFY ACCESSIBLE MEANS OF EGRESS SELECTED, FBC | | BUILDING 1007, FBC ACCESSIBILITY 207. REVISE PLAN TO | | SHOW COMPLIANCE WITH METHOD SELECTED IF ALL ITEMS ARE | | NOT IMMEDIATELY APPARENT (FOR EXAMPLE, IBC2000 ELEVATOR | | AS MEANS OF EGRESS COMPONENT). | | | | 15. A200 REGARDING SIGNAGE ITEM 2; CLARIFY ACCESSIBLE | | MEANS OF EGRESS SELECTED AND REVISE NOTE IF APPLICABLE. | | | | 16. A200, SIGNAGE NOTE 3, THE LANGUAGE, LOCATION AND | | CODE REFERENCE ARE NOT CONSISTENT WITH FBC 703.7; | | REVISE OR CLARIFY. VERIFY THAT ALL NOTES HAVE | | SPECIFICATIONS AND CODE REFERENCES CONSISTENT WITH FBC | | 2014, FBC 107. IT APPEARS THAT SEVERAL REFERENCES ARE | | FROM A PREVIOUS CODE VERSION. | | | | 17. A200 FIRE EXTINGUISHER NOTES DO NOT REFERENCE FBC | | 906, REVISE. | | | | 18. A200 INCIDENTAL USE AREAS AND NON PROTECTED SHAFT | | DO NOT APPEAR TO BE APPLICABLE. EITHER REMOVE OR REVISE | | TO CLARIFY LOCATIONS PROPOSED, FBC 107. | | | | 19. FOR C.O., AN ACCURATE OCCUPANT LOAD FOR THE | | BUILDING IS REQUIRED. SEE A202; GARAGE OCC LOAD IN THE | | CHART IS NOT CONSISTENT WITH THE GARAGE OCC LOAD ON THE | | PLAN. THE TOTAL OCCUPANTS PER LEVEL AND OCCUPANT LOAD | | CATEGORY ARE LACKING SEVERAL FLOORS (15 TO 23), | | PLEASE CORRELATE AND UPDATE TO REFLECT CORRECTED | | OCCUPANT LOAD ON THE POOL DECK AND ANY OTHER CHANGES. | | | | 20. FBC 406.4, CLASSIFY THE PARKING GARAGE AS EITHER | | ENCLOSED OR OPEN. IT IS SUGGESTED THAT THIS BE | | INCORPORATED WITH THE BUILDING GENERAL DATA A201. IF | | OPEN, PROVIDE PERCENTAGE OF OPENINGS PROVIDED TO SHOW | | COMPLIANCE WITH FBC 406.5. IF ENCLOSED, PROVIDE | | VENTILATION 406.6.2. | | | | 21. A202, LIFE SAFETY TCO NOTES INCLUDES FOUR TCO | | PHASES; PLAN SHOWS TWO, PLEASE CORRELATE. | | | | 22. A202, THE LIFE SAFETY PLAN LACKS STAIR NUMBER | | DESIGNATIONS. PROVIDE IN ORDER TO CORRELATE WITH | | DETAILS ON A701-A712, FBC 107. CHECK ALL SHEETS. | | | | 23. IT IS NOT CLEAR WHERE THE EXIT DISCHARGE IS LOCATED | | FOR STAIR LOCATED AT GRIDLINES H3 SHEET A202, FBC 107. | | (ITEM ADDRESSED IN STRUCTURE PERMIT, PLEASE UPDATE.) | | | | 24. AS301 LEVEL 1, THE ACCESSIBLE ROUTE FOR THE | | ACCESSIBLE VAN PARKING SPACE IS NOT CLEAR; THIS WAS | | ADDRESSED IN STRUCTURE PERMIT, PLEASE UPDATE PLANS. | | | | 25. AVIS, LEASING OFFICE, RETAIL/RESTAURANT, AND | | PASSENGER PARKING MINIMUM REQUIREMENTS ARE COVERED BY | | FBC 5TH EDITION ACCESSIBILITY 208, RESIDENTIAL PARKING | | MINIMUM REQUIREMENTS DETERMINED BY FBC 5TH EDITION | | ACCESSIBILITY FAIR HOUSING. | | | | A100, PARKING SCHEDULE, AND OTHER PAGES, REVISE TO SHOW | | COMPLIANCE WITH THE FOLLOWING ITEMS: | | | | THE OPERATION OF THE AVIS BUSINESS AND SPACES IS NOT | | CLEAR. REVISE THE PLAN TO CLARIFY HOW THIS BUSINESS | | WILL OPERATE. WILL CUSTOMERS PICK UP THE CARS, OR WILL | | THE CAR BE BROUGHT TO THE CUSTOMER? IT APPEARS THAT AN | | ACCESSIBLE AVIS SPACE OR A PASSENGER LOADING ZONE MAY | | BE REQUIRED. REVISE PLAN TO DEMONSTRATE COMPLIANCE (OR | | EXEMPTION), INCLUDING APPLICABLE DETAILS. IF THE | | PARKING SPACES ARE FOR AUTO STORAGE ONLY, REVISE PLAN | | TO INCLUDE THIS INFORMATION AS WELL AS DETAILS FOR THE | | PASSENGER LOADING ZONE (FBC ACCESSIBILITY 208.1, 503), | | OR REVISE PLAN TO INCORPORATE INFORMATION REGARDING | | FUNCTION OF THE AUTO RENTAL AREA AND HOW THIS AREA | | COMPLIES WITH (OR IS EXEMPT FROM) ACCESSIBILITY. | | | | 26. FBC ACCESSIBILITY 208, PARKING FOR THE RETAIL AND | | RESTAURANT AREAS IS NOT CLEAR. REVISE PLAN TO INDICATE | | NUMBER OF SPACES, ACCESSIBLE SPACES, VAN SPACES, AND | | LOCATION OR NOTE IF NONE OF THE PARKING SPACES IN THIS | | STRUCTURE ARE FOR THE RETAIL/RESTAURANT AREAS. | | | | 27. SEE PLUMBING COMMENTS REGARDING ACCESSIBILITY AND | | REVISE PLAN TO SHOW COMPLIANCE. | | | | 28. A212, CLARIFY USE OF THE AMENITIES ROOM, FBC 107. | | | | 29. LEASING OFFICE PARKING PROVIDED IS NOT CLEAR. | | REVISE PLAN TO DESIGNATE NUMBER OF PARKING SPACES | | DEDICATED TO LEASING, ACCESSIBLE AND VAN SPACES (NUMBER | | AND LOCATIONS), FBC ACCESSIBILITY 208. IT MAY BE | | HELPFUL TO DESIGNATE WHICH FLOORS OR AREAS ARE FOR | | RESIDENTS, RETAIL VISITORS, AND TRANSIT. | | | | 30. ONE GUEST SPACE IS SHOWN ON THE PARKING SCHEDULE. | | REVISE TO DESIGNATE WHETHER THIS IS FOR PASSENGER, | | LEASING, RETAIL OR RESIDENT PARKING AND NOTE LOCATION | | ON PLAN, FBC ACCESSIBILITY 208. | | | | 31. A212, POOL DECK OCCUPANT LOAD SHOULD BE CALCULATED | | AT 15SF GROSS PER PERSON, PLEASE REVISE TABLES AND | | OCCUPANT LOAD FOR THE POOL DECK. IT DOES NOT APPEAR | | THAT EXITING IS ADEQUATE FOR THIS ASSEMBLY AREA; FBC | | 5TH EDITION TABLE 1004.1.2. THIS ITEM WAS ADDRESSED IN | | THE STRUCTURE PERMIT; PLEASE REVISE TO BE CONSISTENT | | WITH 16040755. | | 32. REVISE PLAN TO SHOW THE 18IN MANEUVERING CLEARANCE, | | PULL SIDE (FBC ACCESSIBILITY 404.2.4), DOOR LOCATED ON | | SHEET A301, DOOR R03H (FBC 5TH ED. ACCESSIBILITY | | 206.4.5), OR OTHERWISE INDICATE THAT THIS WILL NOT BE | | THE ONLY DOOR SERVING A TENANT SPACE, OR PROVIDE AN | | OPENER. | | | | 33. SHEET AS212A, DOORS TO LOBBY FROM POOL AREA SWING | | AGAINST PATH OF TRAVEL, FBC 1008.1.2. | | | | 34. ADVISORY; SHEET AS203, THE SOUTH ACCESSIBLE PARKING | | SPACE (GRIDLINE G4) REQUIRES THE OCCUPANT TO TRAVEL | | BEHIND THE VAN PARKING SPACE TO ACCESS THE LOBBY, AVIS, | | AND RESIDENTIAL LOBBY. THIS WILL BE REQUIRED TO BE | | CORRECTED ON THE BUILDING PERMIT. | | | | 35. FBC 505, LEVEL 12.5 IS NOT SHOWN AS A STORY ON THE | | BUILDING DATA. EITHER REVISE PLAN TO SHOW COMPLIANCE | | WITH REQUIREMENTS FOR MEZZANINES, OR REVISE BUILDING | | DATA INFORMATION. | | | | 36. COMPLIANCE WITH FBC 5TH EDITION ACCESSIBILITY, FAIR | | HOUSING IS NOT CLEAR. IF DESIGNING USING THE FAIR | | HOUSING ACT DESIGN MANUAL, PROVIDE UNIT LAYOUTS WITH | | UNIT TYPE AND DIMENSIONS SHOWING COMPLIANCE. | | | | IF USING ANOTHER METHOD, PROVIDE DETAILS AND DIMENSIONS | | TO SHOW COMPLIANCE. | | | | 37. F202 AND E202 SHOW A MEZZANINE, PROVIDE AN | | ARCHITECTURAL FLOOR PLAN; LOCATION IS NOT CLEAR, AND IS | | THIS A MEZZANINE PER FBC505? INCLUDE ALL INFORMATION | | REQUIRED TO DETERMINE CODE COMPLIANCE FOR THIS AREA, | | FBC 107. IF THIS IS NOT A MEZZANINE, IT IS SUGGESTED | | THAT THE NAME OF THE AREA BE REVISED FOR CLARITY. | | | | 38. UNIT NAMES ON LIFE SAFETY SHEETS ARE NOT THE SAME | | AS FLOOR PLANS (FOR INSTANCE, SEE A202 AND A302), | | CORRELATE. | | | | 39. A FIRE ALARM SYSTEM IN COMPLIANCE WITH FBC | | 907.2.13.1 IS REQUIRED PER FBC 403.4.2. SMOKE DETECTORS | | IN COMPLIANCE WITH FBC 907.2.13.1 IS REQUIRED PER FBC | | 403.4.1. REVISE PLAN TO INCLUDE NOTES, OR ADVISE WHERE | | COMPLIANCE WITH THESE STANDARDS CAN BE LOCATED ON THE | | PLAN. BOTH ITEMS REQUIRE SEPARATE APPLICATIONS, | | PERMITS, PLANS AND FEES, FBC 107, AND WILL BE REVIEWED | | AT THAT TIME. | | | | 40. FBC 403.4.5, EMERGENCY RESPONDER RADIO COVERAGE, | | REVISE PLAN TO INCLUDE A NOTE TO SHOW COMPLIANCE WITH | | THIS SECTION. | | | | NFPA 1, CHAPTER 11, BUILDING SERVICES; 11.10 TWO-WAY | | RADIO ENHANCEMENT SERVICES. | | 11.10.1 IN ALL NEW AND EXISTING BUILDINGS, MINIMUM | | RADIO SIGNAL STRENGTH FOR FIRE DEPARTMENT | | COMMUNICATIONS SHALL BE MAINTAINED AT A LEVEL | | DETERMINED BY THE AHJ. | | MAINTAIN A MINIMUM RADIO SIGNAL STRENGTH OF 102.0 DBM | | FOR THE RADIO SYSTEM USED BY WEST PALM BEACH FIRE | | RESCUE. IF THE MINIMUM CANNOT BE MAINTAINED, A | | BI-DIRECTIONAL AMPLIFIED SYSTEM SHALL BE INSTALLED WITH | | A MINIMUM 2-HOUR RUN TIME BATTERY BACK-UP. | | | | 41. STANDBY POWER, FBC 403.4.8, EMERGENCY POWER 403.4.9 | | REQUIRED. REVISE PLAN TO SHOW COMPLIANCE OR ADVISE AS | | TO WHERE THIS CAN BE LOCATED. CLARIFY WHICH ITEMS WILL | | BE ON EMERGENCY POWER. WHICH ELEVATOR(S) WILL BE | | INCLUDED (FBC 1007)? | | | | 42. FBC 403.5.4 SMOKEPROOF EXIT, THE NEW STAIR (5?) | | DOES NOT APPEAR ON THE MECHANICAL SHEETS (MEZZANINE | | LEVEL AS SHOWN ON FIRE AND ELEC PAGES, M704, OTHER | | PAGES). | | | | 43. FBC 905.4, STANDPIPE REQUIRED IN STAIRS, UNABLE TO | | LOCATE THIS FOR THE NEW STAIR. | | | | 44. FBC 403.6.1, COMPLIANCE WITH FIRE SERVICE ACCESS | | ELEVATOR REQUIREMENTS IS NOT CLEAR. SHEET A202 (AND | | OTHER LIFE SAFETY SHEETS) SHOW A FIRE SERVICE LOBBY ON | | THE WEST SIDE WHICH IS NOT INCLUDED IN TCO AREA 1. ALL | | LIFE SAFETY SYSTEMS ARE TO BE IN PLACE FOR TCO. | | | | THE ELEVATORS DESIGNATED AS FIRE SERVICE IS NOT CLEAR. | | FOR INSTANCE, SEE LEVEL 8. IT APPEARS THAT ONLY THE | | NORTH ELEVATOR, WEST SIDE IS DESIGNATED AS THE FIRE | | SERVICE ELEVATOR, BUT AT LEAST TWO ARE REQUIRED PER FBC | | 403.6.1. | | REVISE PLAN TO SHOW COMPLIANCE WITH THE FIRE SERVICE | | ELEVATORS REQUIREMENT, INCLUDING THE WEIGHT CAPACITY | | REQUIREMENT. FIRE SERVICE ELEVATORS ARE TO COMPLY WITH | | FBC 3007. REVISE PLAN TO SHOW COMPLIANCE WITH 3007.2 | | RECALL, 3007.7.5 SIGNAGE, 3007.3 SPRINKLERS, 3007.4 | | WATER PROTECTION, 3007.6.1, 3007.6.2 HOISTWAY LIGHTING, | | 3007.7.2 1 HOUR SMOKE BARRIER FOR LOBBY, 3007.7.3 LOBBY | | DOORS, 3007.8 MONITORING, 3007.9 ELECTRICAL POWER, | | 3007.9.1 PROTECTION OF WIRING AND CABLES. | | | | 45. SOME LEVELS (FOR INSTANCE, LEVELS 12.5, 13) LACK A | | FIRE SERVICE ELEVATOR FBC 403. | | | | 46. FBC 3004, HOISTWAY VENTING NOT CLEAR, REVISE PLAN | | TO SHOW COMPLIANCE. | | | | 47. FBC 3002.4, SHOW LOCATION OF STRETCHER ELEVATOR | | SIGNAGE. | | | | 48. FBC 908.7, CARBON MONOXIDE DETECTORS ARE REQUIRED, | | REVISE. | | | | 49. PRODUCT APPROVALS FOR COMPONENTS AND CLADDING HAVE | | NOT BEEN SUBMITTED. THEY MAY BE A DEFERRED SUBMITTAL. | | THEY MAY BE SUBMITTED, PRIOR TO INSTALLATION, AS A | | REVISION, PRIOR TO INSTALLATION. | | | | 50. FLOORING UNDERLAYMENT IS TO COMPLY WITH FBC 1207.2, | | 1207.3, AND 603.1. THIS MAY BE A DEFERRED SUBMITTAL. IF | | DEFERRED, THE TEST REPORTS ARE TO BE SUBMITTED AS A | | REVISION PRIOR TO INSTALLATION. AS STRUCTURAL PLANS | | SHOW AN 8 INCH SLAB, PRODUCTS TESTED WITH EITHER A 6 | | INCH OR AN 8 INCH SLAB ARE ACCEPTABLE. | | | | A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. | | THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM | | CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED | | GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | OR UL 723. | | | | 51. SMOKE CONTROL REFERENCED, BUT REPORT NOT PROVIDED, | | FBC 909.4. | | | | 52. A SPOT CHECK ON THE ENERGY CALCS WAS DONE. PLEASE | | CLARIFY THE FOLLOWING: | | EXTERNAL LIGHTING SHOWS NO ENTRY. | | | | 53. THIS PERMIT WILL BE ISSUED WITH THE FOLLOWING | | PROVISOS: | | | | A. PROVISO: TCO AT EACH PHASE IS SUBJECT TO APPROVAL OF | | THE BUILDING OFFICIAL (OR HIS REPRESENTATIVE) AND FIRE | | DEPARTMENT, AND MAY INCLUDE ITEMS NOT WITHIN THE SCOPE | | OF THIS REVIEW. A TCO REQUEST FORM AND FEE WILL BE | | REQUIRED. THIS FORM IS AVAILABLE UPON REQUEST BY EMAIL. | | | | C. SEPARATE PERMITS (APPLICATION, PLANS, REVIEWS, AND | | FEES) REQUIRED FOR ALL ITEMS OTHER THAN MECHANICAL, | | ELECTRICAL, AND PLUMBING FOR THE BUILDING AS SHOWN ON | | THE PLANS. THIS INCLUDES SIGNS, FIRE ALARM, FIRE | | SPRINKLERS, LANDSCAPING. | | | | SUB PERMITS (APPLICATION, SUB PERMIT FEE) ARE REQUIRED | | FOR MECHANICAL, ELECTRICAL, AND PLUMBING PRIOR TO | | COMMENCEMENT OF WORK. | | | | A ROOFING SUB PERMIT IS REQUIRED PRIOR TO COMMENCEMENT | | OF ROOFING WORK. AS ROOF DOCUMENTS HAVE NOT BEEN | | PROVIDED, THIS IS A DEFERRED SUBMITTAL. PRODUCT | | APPROVALS REVIEWED BY DESIGNER OF RECORD, SELECTED | | ASSEMBLY, ENGINEERING IF APPLICABLE ARE TO BE SUBMITTED | | AS A REVISION WITH A ROOF PERMIT APPLICATION. | | | | D. COMPONENTS AND CLADDING PRODUCT APPROVALS ARE TO BE | | REVIEWED BY DESIGNER OF RECORD AND SUBMITTED AS A | | REVISION PRIOR TO INSTALLATION. | | | | E. PROVISO, THIS STUCTURE SERVES A BUILDING WHICH HAS | | NOT BEEN REVIEWED BY THIS DEPARTMENT (TRAIN STATION). | | ACCESSIBLE ROUTE IN COMPLIANCE WITH FBC 5TH EDITION | | ACCESSIBILITY IS REQUIRED AND WILL BE VERIFIED IN THE | | FIELD. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2017-01-06 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2017-01-06 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2017-01-06 |
Time |
11:10 |
Sent To |
|
|
Notes |
2017-01-06 11:11:23 | VE CHANGES OK | | | | PREVIOUS PROVISO: | | | | PLEASE SUBMIT TO OUR OFFICE A COPY OF THE EASEMENT | | AGREEMENT WITH FPL UTILITY TO ENSURE THAT THE UTILITY | | VAULT ROOMS ARE NOT UNDER OUR AHJ. | | | | VAL PEREZ | | ELECTRICAL PLANS EXAMINER | | *6717 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2016-11-02 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-11-02 |
Time |
11:49 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-11-02 |
Time |
11:49 |
Sent To |
|
|
Notes |
2016-11-02 12:02:58 | PREVIOUS COMMENTS ADDRESSED BASED ON ORIGINAL REVIEW | | PERFORMED BY MIKE ALBARRAN... | | | | PROVISO: | | | | PLEASE SUBMIT TO OUR OFFICE A COPY OF THE EASEMENT | | AGREEMENT WITH FPL UTILITY TO ENSURE THAT THE UTILITY | | VAULT ROOMS ARE NOT UNDER OUR AHJ. | | | | VAL PEREZ | | ELECTRICAL PLANS EXAMINER | | *6717 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-10-11 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-10-11 |
Time |
18:50 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-08-05 |
Time |
10:45 |
Sent To |
|
|
Notes |
2016-10-11 18:51:08 | REVIEWED FOR COMPLIANCE WITH: 5TH EDITION FBC 2014 & | | NFPA 70 2011 (NEC) | | | | BELOW ARE THE ELECTRICAL COMMENTS FOR THE FAILED PLAN | | REVIEW: | | | | TYPICAL COMMENT: CITY OF WEST PALM BEACH AMENDMENTS TO | | THE FBC-B SECTION 107.2.1.4 REQUIRES THAT BUILDING | | PLANS BE DRAWN TO A MINIMUM 1/8? SCALE. THE SUBMITTED | | DRAWINGS ARE DRAWN TO A 3/32? SCALE MAKING THEM A BIT | | SMALLER THAN THE REQUIRED. PLEASE CORRECT ACCORDINGLY. | | | | SHEET E000 | | 1. CLARIFY THE FRONT OF PANEL WHEN RECESSED IN THE | | DISTRIBUTION EQUIPMENT BOX | | 2. IS IT YOUR INTENT TO SHARE THESE SYMBOLS IN THE | | LIGHTING LEGEND | | 3. IS IT YOUR INTENT TO SHARE THIS SYMBOL IN THE POWER | | CONNECTIONS BOX | | 4. FIRE ALARM WORK SHALL BE UNDER SEPARATE PERMIT & | | SUBMITTAL | | SHEET E001 | | 5. PLEASE TRY TO BE CONSISTENT WITH THE ABBREVIATIONS | | THROUGHOUT THE SET. I SEE MULTIPLE SYMBOLS W/THE SAME | | DESIGNATION. SYMBOLS NOT ALIGNED TO DESCRIPTION. | | 6. IS IT YOUR INTENT TO SHARE THIS SYMBOL IN THE | | DEMOLITION NOTES BOX | | SHEET E201A | | 7. NEC 422.31: EWH-4 REQUIRES A DISCONNECT | | 8. NEC 210.8(B): RECEPTACLE OUTLETS IN GARAGES OR | | INDOOR WET LOCATIONS SHALL BE GFI PROTECTED | | 9. SEE NEC 430 FOR THE REQUIRED DISCONNECTS AND | | ADDITIONAL CONTROLS AND SAFETY DEVICES REQUIRED, | | TYPICAL TO ALL MOTOR LOADS | | SHEET E202 | | 10. HIGHLY UNLIKELY THAT THERE WILL ONLY BE 2 OUTLETS | | IN THE MEZZANINE | | SHEET E203 | | 11. THE FOLLOWING MOTORS AND APPLIANCES REQUIRED | | DISCONNECTS AS MENTIONED ABOVE AHU2-1, FCU2-2, EWH-8, | | FCU2-1.1, FCU2-3, FCU2-1.2, EWH-4 | | SHEET E204 | | 12. SAME AS ABOVE FOR FCU3-1 | | SHEET E208 | | 13. SAME AS ABOVE FOR FCU7-1 | | SHEET E210 | | 14. SAME AS ABOVE FOR FCU9-3, SF9-3, AS WELL AS EVERY | | MOTOR & HVAC EQUIPMENT ON ROOF | | SHEET E211 | | 15. SAME AS ABOVE FOR FCU10-1 | | SHEET E212 | | 16. SAME AS ABOVE FOR UNITS SF11-1, FCU12.5-1, FCU11-2 | | & CU12.5-1 | | SHEET E213 | | 17. SAME AS ABOVE FOR AHU12-6, EF12-1 | | SHEET E214 | | 18. SAME AS ABOVE FOR ALL MOTORS AND ELECTRIC WATER | | HEATER IN ROOM 12.508 | | SHEET E301A | | 19. RETAIL R02 ? LIGHTING ARRANGEMENT AS DESCRIBED DOES | | NOT MEET THE DAYLIGHT ZONE CONTROL REQUIREMENTS OF THE | | FBC-E405.2.2.3 | | 20. FBC-B 1011.1 EXITS AND EXIT ACCESS SHALL BE MARKED | | BY AN APPROVED EXIT SIGN READILY VISIBLE FROM ANY | | DIRECTION OF EGRESS TRAVEL. THE PATH OF EGRESS SHALL BE | | CLEARLY MARKED WHEN NOT READILY VISIBLE. THERE SHALL | | NOT BE MORE 100? BETWEEN EXIT SIGN ALONG THE PATH OF | | EGRESS. | | 21. RETAIL R01 ? LIGHTING ARRANGEMENT AS DESCRIBED DOES | | NOT MEET THE DAYLIGHT ZONE CONTROL REQUIREMENTS OF THE | | FBC-E405.2.2.3 | | 22. RETAIL R03 ? LIGHTING ARRANGEMENT AS DESCRIBED DOES | | NOT MEET THE DAYLIGHT ZONE CONTROL REQUIREMENTS OF THE | | FBC-E405.2.2.3 | | 23. DUE TO THE LACK OF ROOM LABELS, ADDITIONAL LIGHTING | | CONTROLS MAY BE REQUIRED | | SHEET E303, E304, E305, E306, E307, E308, E309, E310, | | E311, E312 | | 24. THIS SHEET DOES NOT CLEARLY INDICATE THE LOCATION | | OF EGRESS DOORS OR UP/DOWN RAMP, THEREFORE PROPER EXIT | | LIGHT LOCATION IS NOT IDENTIFIABLE | | SHEET E314 | | 25. THIS AREA IS NOT IDENTIFIED ON THE PLANS, THEREFORE | | EXIT LIGHTING AND LIGHTING CONTROL REQUIREMENTS CAN?T | | BE PROPERLY DETERMINED | | SHEET E318 | | 26. EXIT LIGHT REQUIRED BY ROOF EXIT DOORWAY | | SHEET E501 | | 27. NEC 210.52(C)(4): (UNITS 6, 2, 04,) AN OUTLET IS | | REQUIRED ON EITHER SIDE OF THIS SINK | | 28. NEC 210.70: (UNIT 04) THE AREA LEADING TO THE | | BEDROOM IS MISSING ILLUMINATION | | SHEET E503 | | 29. NEC 210.52(A)(2): WALL SPACE. ANY WALL SPACE 2 FT. | | OR MORE IN WIDTH SHALL REQUIRE A RECEPTACLE. SEE LIVING | | ROOM OF UNIT 20 | | 30. NEC 210.52(C)(4): (UNITS 20 ) AN OUTLET IS REQUIRED | | ON EITHER SIDE OF THIS SINK | | 31. NEC 110.26(D): ILLUMINATION SHALL BE PROVIDED FOR | | ALL WORKING SPACES ABOUT SERVICE EQUIPMENT, | | SWITCHBOARDS, AND PANELBOARDS. THIS LIGHT SHALL NOT BE | | CONTROLLED BY AUTOMATIC MEANS ONLY. CHECK THE SMC | | CLOSET OF UNIT 20 | | 32. NEC 210.52(C)(4): (UNITS 18) AN OUTLET IS REQUIRED | | ON EITHER SIDE OF THIS SINK | | 33. NEC 210.52 (A)(1): RECEPTACLES SHALL BE INSTALLED | | SUCH THAT NO POINT MEASURED HORIZONTALLY ALONG THE | | FLOOR LINE IN ANY WALL SPACE IS MORE THAN 6 FT. FROM A | | RECEPTACLE OUTLET. THIS INCLUDES THE DISTANCE FROM THE | | EDGE OF THE WALL. A FLOOR BOX IS REQUIRED ALONG THE | | WALL WITH ALL THE WINDOWS IN THE LIVING ROOM OF UNIT 18 | | 34. NEC 210.52(H): IN DWELLING UNITS, HALLWAYS OF 10 FT | | OR MORE IN LENGTH SHALL HAVE AT LEAST ONE RECEPTACLE | | OUTLET. SEE THE MASTER BEDROOM CORRIDOR OF UNIT 18 | | 35. NEC 210.52(A)(2): WALL SPACE. ANY WALL SPACE 2 FT. | | OR MORE IN WIDTH SHALL REQUIRE A RECEPTACLE. SEE WALL | | BEHIND MASTER BEDROOM SINK OF UNIT 18 | | 36. NEC 110.26(D): ILLUMINATION SHALL BE PROVIDED FOR | | ALL WORKING SPACES ABOUT SERVICE EQUIPMENT, | | SWITCHBOARDS, AND PANELBOARDS. THIS LIGHT SHALL NOT BE | | CONTROLLED BY AUTOMATIC MEANS ONLY. SEE AREA IN FRONT | | OF ELECTRICAL PANEL OF UNIT 18. | | SHEET E504, UNIT L1 | | 37. FBC-RE3901.4: IF THE AREA ADJACENT TO THE | | REFRIGERATOR IS COUNTER SPACE, AN OUTLET IS REQUIRED. | | 38. FBC-ER3901.4.1: KITCHEN RECEPTACLE REQUIRED | | 39. ARE YOU SURE THAT YOU WANT THE SWITCH FOR THE | | DISPOSAL THAT FAR AWAY FROM THE SINK | | 40. FBC-RE3901.2.1: A RECEPTACLE IS REQUIRED NO MORE | | THAN 6? FROM THE WALL EDGE OF THE KITCHEN TO THE LR. | | 41. FBC-RE3901.2.1: THE LINEAR WALL SPACE BETWEEN THESE | | TWO OUTLETS EXCEEDS THE 12? RULE OF THE CODE. THIS | | APPLIES TO THE BEDROOM OUTLETS. | | SHEET E504, UNIT L2 | | 42. SEE UNIT L1 KITCHEN COMMENTS. | | SHEET E504, UNIT L3 | | 43. SEE UNIT L1 KITCHEN COMMENTS. | | 44. SEE UNIT L1 COMMENT 41. | | 45. SEE COMMENTS 40 & 41 FOR UNIT L1. | | | | SHEET E505, UNIT L4 | | 46. SEE COMMENT 37 ABOVE FOR UNIT L1. | | 47. SEE COMMENTS 41 ABOVE FOR UNIT L1. LOWER BEDROOM. | | 48. PLEASE ABIDE BY THE 6 - 12 RECEPTACLE SPACING RULE | | AND RELOCATE YOUR RECEPTACLES ACCORDINGLY. (UPSTAIRS | | SITTING AREA). | | 49. SEE COMMENT 41 ABOVE. UPPER BEDROOM. | | SHEET E505, UNIT L5 | | 50. SEE COMMENT 39 ABOVE. KITCHEN DISPOSAL | | 51. SEE COMMENT 41 ABOVE FOR UNIT L1. LOWER BEDROOM. | | 52. SEE COMMENT 41 ABOVE FOR UNIT L1. UPPER BEDROOM. | | 53. SEE COMMENT 48 ABOVE FOR UNIT L4. UPPER SITTING | | AREA. | | SHEET E506, UNIT L6 | | 54. FBC-RE3901.2.1SPACING. RECEPTACLES SHALL BE | | INSTALLED SUCH THAT NO POINT MEASURED HORIZONTALLY | | ALONG THE FLOOR LINE IN ANY WALL SPACE IS MORE THAN 6 | | FT. FROM A RECEPTACLE OUTLET. THIS INCLUDES THE | | DISTANCE FROM THE EDGE OF THE WALL. LOWER BEDROOM | | 55. FBC-RE3903.4 STORAGE OR EQUIPMENT SPACES. AT LEAST | | ONE LIGHTING OUTLET CONTAINING A SWITCH OR CONTROLLED | | BY A WALL SWITCH SHALL BE INSTALLED WHERE THESE SPACES | | ARE USED FOR STORAGE OR CONTAIN EQUIPMENT REQUIRING | | SERVICING. THE LIGHTING OUTLET SHALL BE PROVIDED AT OR | | NEAR THE EQUIPMENT REQUIRING SERVICING. EWH CLOSET | | 56. CAREFUL NOT TO PLACE THIS SWITCH BEHIND THE DOOR TO | | THIS BEDROOM. DOOR TO ROOM NOT DRAWN PLAN. UPPER | | BEDROOM. | | 57. FBC-RE3901.2.1: RELOCATE THIS OUTLET TO MEET CODE | | SPACING REQUIREMENTS. UPPER SITTING AREA. | | 58. SEE NOTE 54 ABOVE. UPPER BEDROOM. | | SHEET E506, UNIT L7 | | 59. SEE COMMENT 55 ABOVE. EWH CLOSET | | 60. FBC-ER3901.4.4/NEC 210.52(C)(4) COUNTERTOP SPACES | | SEPARATED BY RANGETOPS, REFRIGERATORS, OR SINKS SHALL | | BE CONSIDERED AS SEPARATE COUNTERTOP SPACES IN APPLYING | | THE REQUIREMENTS OF 210.52(C)(1). THEREFORE AN OUTLET | | IS MISSING FROM THIS END OF THE PENINSULA. | | 61. SEE COMMENT 57 ABOVE. | | | | 62. SHEET E506, UNIT L8 | | 63. SEE COMMENT 55 ABOVE. | | 64. SEE COMMENT 57 ABOVE. BEDROOM & LIVING ROOM | | SHEET E506, UNIT L9 | | 65. SEE COMMENT 55 ABOVE | | 66. SEE COMMENT 57 ABOVE. BEDROOM & LIVING ROOM | | SHEET E507, PENTHOUSE | | 67. THIS IS AN INTERIOR BATHROOM AND IT REQUIRES AN | | EXHAUST FAN. IF A NON-CONTINUOUS UNIT IS USED, IT SHALL | | BE CONTROLLED WITH THE LIGHT SWITCH. HALF BATH | | 68. ADJUST OUTLETS ALONG THESE WALLS TO MEET CODE | | COMPLIANCE. CURTAIN WALL LIVING ROOM & DINING ROOM. | | 69. IN THE INTEREST OF LIFE SAFETY, CONVENIENCE AND | | ENERGY CONSERVATION THESE LIGHTS SHOULD BE ON A 3 WAY | | SWITCH. | | SHEET E507, UNIT 8B | | 70. SEE COMMENT 55 ABOVE. | | 71. FBC-RE3901.2.2: ANY WALL SPACE 2 FT. OR MORE IN | | WIDTH SHALL REQUIRE A RECEPTACLE. ROOM ADJACENT TO | | KITCHEN | | SHEET E601, E602, E610, APPROVED W/PROVISO | | 72. NEC110.26 (D) ILLUMINATION: ILLUMINATION SHALL BE | | PROVIDED FOR ALL WORKING SPACES ABOUT ELECTRICAL | | SERVICE EQUIPMENT INSTALLED INDOORS AND SHALL NOT BE | | CONTROLLED BY AUTOMATIC MEANS ONLY. THIS APPLIES TO ALL | | ROOMS ENLARGED ON THIS SHEET. | | SHEET E701 | | 73. NEC 110.24: ALL SERVICE EQUIPMENT SHALL BE LEGIBLY | | MARKED IN THE FIELD WITH THE MAXIMUM AVAILABLE FAULT | | CURRENT. THE FIELD MARKING(S) SHALL INCLUDE THE DATE | | THE FAULT CURRENT CALCULATION WAS PERFORMED AND BE OF | | SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT | | INVOLVED. | | 74. CLARIFY FEEDER LABELED AS E702D'S DESTINATION. I | | CAN?T FIND IT ON SHEET E702. | | SHEET E703, APPROVED W/PROVISO | | 75. FIRE ALARM WORK UNDER SEPARATE PERMIT | | SHEET E1401 | | 76. THE PANEL SCHEDULE OF N1MSBHA DOES NOT MATCH THE | | RISER DIAGRAM OF SHEET E701. | | 77. CORRECT CKT. 17, 19. 21 OF LS1DPH TO MATCH SHEET | | E702 (LS21HA) | | 78. PANEL SCHEDULE OF E1DPH DOES NOT MATCH RISER | | DIAGRAM OF SHEET E702 | | SHEET E1406 | | 79. OCP FOR UNIT PENT PANEL DOES NOT MATCH WHAT IS | | REFLECTED ON RISER OF SHEET E701 | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER | | (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER | | WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | GREATLY APPRECIATED. | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | THANK YOU, | | MIKE ALBARRAN | | ELECTRICAL PLANS EXAMINER | | PH: 561-805-6746 | | EMAIL: [email protected] | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2016-12-14 |
|
|
Cont ID |
|
Sent By |
mgonzale |
Date |
2016-12-14 |
Time |
|
Rev Time |
1.00 |
Received By |
mgonzale |
Date |
2016-12-14 |
Time |
|
Sent To |
|
|
Notes |
2016-12-14 15:36:48 | REVISED PLANS DATED 12/14/2016 HAVE BEEN SUBMITTED AND | | APPROVED THRU ENGINEERING. | | | | MANUEL JULIAN GONZALEZ | | ENGINEERING PROJECT COORDINATOR | | PUBLIC WORKS DEPARTMENT | | 401 CLEMATIS STREET, 4TH FLOOR | | WEST PALM BEACH, FL 33401 | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | MAIN PHONE: (561) 822-1200 | | DIRECT: (561) 494-1085 | | FAX: (561) 494-1116 | | EMAIL: [email protected] | | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS | | /FORMS,-PERMITS-APPLICATIONS |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2016-10-05 |
|
|
Cont ID |
|
Sent By |
mgonzale |
Date |
2016-10-05 |
Time |
|
Rev Time |
0.50 |
Received By |
|
Date |
2016-10-05 |
Time |
|
Sent To |
HIST |
|
Notes |
2016-10-05 09:22:22 | PLEASE RESPOND TO COMMENTS IN WRITING. | | | | BACKFLOWS MUST BE AS CLOSE TO CITY OF WPB SOURCE AS | | POSSIBLE. | | | | IF BACKFLOWS ARE SHOWN IN THE CLOSEST LOCATION AS | | POSSIBLE, REPLY IN WRITING TO THIS COMMENT SO THAT A | | MEETING CAN BE ARRANGED WITH UTILITIES CUSTOMER SERVICE | | TO GET A VARIANCE IF THERE IS LEGITIMATE HARDSHIP. AN | | ENLARGE VIEW OF THE WATER METER AND BACLFLOWS LOCATIONS | | MAY BE ADEQUATE TO BETTER DESCRIBE THE CLEARANCES | | AROUND THESE CONSTRICTED AREAS. ENOUGH CLEARANCE SHALL | | BE (18") AROUND THE DEVICES TO ALLOW PROPER MAINTENANCE | | SPACE. BACKFLOWS JUST INSIDE BUILDING OR HARD SURFACE | | SHALL HAVE A FLOOR DRAIN TO AVOID FLOODING WHEN | | BACKFLOWS ARE NOT WORKING PROPERLY OR WHEN ROUTINE | | MAINTENANCE IS REQUIRED. | | | | SUBMIT SHOP DRAWINGS FOR DCDA AND RPPA FOR DOMESTIC, | | FIRE, IRRGIGATION. ETC./IMPORTANT MESSAGE: AS OF | | DECEMBER 20, 2015 THE CITY OF WEST PALM BEACH. | | CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED MAKING | | KNOWN THAT "ALL BACKFLOW DEVICES MUST BE LEAD FREE." | | FOR MORE INFORMATION REFER TO THE LINK BELOW: HTTP://WP | | B.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLICATIONS/B | | ACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL | | | | MANUEL JULIAN GONZALEZ | | ENGINEERING PROJECT COORDINATOR | | PUBLIC WORKS DEPARTMENT | | 401 CLEMATIS STREET, 4TH FLOOR | | WEST PALM BEACH, FL 33401 | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | MAIN PHONE: (561) 822-1200 | | DIRECT: (561) 494-1085 | | FAX: (561) 494-1116 | | EMAIL: [email protected] | | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS | | /FORMS,-PERMITS-APPLICATIONS | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2017-01-09 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-01-09 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-12-29 |
Time |
09:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2016-11-23 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-11-23 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-10-28 |
Time |
14:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2016-09-09 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-09-09 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-08-12 |
Time |
09:56 |
Sent To |
|
|
Notes |
2016-09-09 13:47:03 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THIS PLAN SET NEEDS TO BE UPDATED WITH THE SUBMITTED | | REVISIONS OF PERMIT # 16040755. | | | | | | 2) PLEASE PROVIDE PLAN SHEET REVISION CLOUDS OR | | NUMBERED NARRATIVE RESPONSES TO THE ABOVE. | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
P |
Date |
2017-01-24 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-01-24 |
Time |
13:44 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-01-24 |
Time |
04:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2016-11-29 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-11-28 |
Time |
09:48 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-11-28 |
Time |
05:35 |
Sent To |
|
|
Notes |
2016-11-27 08:14:02 | 1) SHT. P717 SHOWS( 2 )-2 1/2 INCH LINES TO THE RETAIL | | SPACE. SHOW HOW THESE LINES CONNECT TO THE GAS MAIN. | | WPB AMEND. TO FBC SEC. 107.3.5.1.5. FUTURE LINES SHALL | | BE EQUIPPED WITH REGULATORS AND THE OUTLET FROM THE | | REGULATOR SHALL HAVE A NIPPLE, VALVE AND CAP INSTALLED. | | THE REGULATOR VENT OUTLET SHALL BE CAPPEDOR PLUGGED | | UNTIL PUT INTO USE. | | 2) SHOW THE APPROXIMATE DISTANCE OF THE RUN OF THE PIPE | | TO THE RETAIL SPACE FROM THE METER.WPB AMEND. TO FBC | | SEC. 107.2.1. | | 3) SHT.P718 REFERS TO A DETAIL FOR THE SHUTOFF VALVE | | FOR THE APPLIANCE AT THE AMENITIES AND ALSO FOR THE | | SHUTOFF VALVE FOR THE POOL EQUIPMENT. SPECIFIY THE | | SHEET WHERE THIS DETAIL CAN BE FOUND. I DID NOT FIND IT | | ON ANY OF THE DETAIL SHEETS. | | 4) PLACE THE TOTAL BTU LOAD FOR EACH SYSTEM IN THE | | APPROPRIATE SYSTEM SIZING BOX ( SYSTEM #1, #2 #3 ). IT | | IS TIME CONSUMNING ADDDING IT UP ON THE RISERS AND THIS | | WILL AID IN THE RE-EVIEW TIME FOR THE GAS.WPB AMEND. TO | | FBC SEC. 107.2.1. | | 5) REFER TO THE SHEET NUMBER FOR THE CONTINUATION OF | | THE GAS RISERS, NOT JUST THE LETTER.WPB AMEND. TO FBC | | SEC. 107.2.1. | | 6) SHOW THE CONNECTION POINT OF THE RISER Q-Q TO THE | | MAIN GAS SYSTEM AND REFERENCE THE SHEET NUMBER.WPB | | AMEND. TO FBC SEC. 107.2.1. | | 7) SHT.P719 - THE SIZING SYSTEM BOXES REFER TO THE 2009 | | IFC. THE FUEL GAS CODE IN EFFECT IS THE 2014 FBC-FUEL | | GAS. | | 8) SHT. P719 - SIZING SYSTEM #1 BOX - THE GAS TABLE | | REFERENCED, 402.3 (3) IS FOR LESS THAN 2 PSI IN THE FBC | | FUEL GAS BUT THE TEXT IN THE BOX STATES THE SYSTEM IS A | | 2 PSI SYSTEM WITH A PRESSURE DROP OF 1.0 PSI. CLARIFY. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2016-09-08 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-09-08 |
Time |
14:41 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-09-08 |
Time |
14:41 |
Sent To |
|
|
Notes |
2016-09-08 14:57:10 | 1ST REVIEW | | | | | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | | | GAS COMMENTS: | | | | 1. SHOW ALL CUT SECTIONS OF PIPE AND CORRESPONDING | | LENGTHS PER FBC-2014 FUEL GAS, SECS. 402.4.1, 402.4.2. | | | | 2. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | | | 3. THE SYSTEM IS TO BE DESIGNED AND SIZED PER IFGC 2014 | | OR FBC FG 2014 5TH EDITION. CHECK TABLE NUMBERS THEY | | HAVE CHANGED. | | | | 4. PROVIDE SHUT OFF AND DRIP LEG AT EACH APPLIANCE. PER | | FBC FG | | 408.4 SEDIMENT TRAP. | | WHERE A SEDIMENT TRAP IS NOT INCORPORATED AS PART OF | | THE APPLIANCE, A SEDIMENT TRAP SHALL BE INSTALLED | | DOWNSTREAM OF THE APPLIANCE SHUTOFF VALVE AS CLOSE TO | | THE INLET OF THE APPLIANCE AS PRACTICAL. THE SEDIMENT | | TRAP SHALL BE EITHER A TEE FITTING HAVING A CAPPED | | NIPPLE OF ANY LENGTH INSTALLED VERTICALLY IN THE | | BOTTOMMOST OPENING OF THE TEE AS ILLUSTRATED IN FIGURE | | 408.4 OR OTHER DEVICE APPROVED AS AN EFFECTIVE SEDIMENT | | TRAP. ILLUMINATING APPLIANCES, RANGES, CLOTHES DRYERS, | | DECORATIVE VENTED APPLIANCES FOR INSTALLATION IN VENTED | | FIREPLACES, GAS FIREPLACES, AND OUTDOOR GRILLS NEED NOT | | BE SO EQUIPPED. | | 409.5 APPLIANCE SHUTOFF VALVE. | | EACH APPLIANCE SHALL BE PROVIDED WITH A SHUTOFF VALVE | | IN ACCORDANCE WITH SECTION 409.5.1, 409.5.2 OR 409.5.3. | | | | 5. PROVIDE LENGTH AND SIZE OF PIPING TO POOL EQUIPMENT. | | PER FBC-2014 FUEL GAS, SECS. 402.4.1, 402.4.2. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-01-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-01-24 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-12-21 |
Time |
09:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-12-21 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2016-12-21 |
Time |
11:09 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2016-10-27 |
Time |
14:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-10-12 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2016-10-12 |
Time |
07:40 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2016-08-04 |
Time |
15:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2016-11-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-11-19 |
Time |
09:34 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-11-16 |
Time |
14:21 |
Sent To |
|
|
Notes |
2016-11-19 09:13:47 | MU 2016 18622 | | MU 2016 18623 | | | | RECEIPTS (ALSO WITH PERMIT 16040755) ROUTED TO RECORDS | | PLAN PAGES FROM IMPACT FEE REVIEW W/PALM BEACH COUNTY | | ROUTED TO RECORDS (SHEETS A300 THROUGH A318, A500) | | SHEETS SUBMITTED TO IMPACT HAVE A "PROGRESS SET" DATE | | OF 7/6/16; SHEETS IN PROJECTDOX HAVE A "PERMIT SET" | | DATE OF 11/20/16. PAGES APPEAR THE SAME, IN PARTICULAR | | SHEET A500. VERIFIED THAT SQ FT AREA AND UNIT TOTALS | | ARE IDENTICAL. | | | | | | | | | | | | | 2016-11-17 14:21:39 | IMPACT FEES GUVEN TO SHILL |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2016-09-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-09-07 |
Time |
11:42 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-09-07 |
Time |
11:42 |
Sent To |
|
|
Notes |
2016-09-07 11:45:24 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED. | | CONTACT 561-233-5025 FOR MORE INFORMATION. A PLAN | | STAMPED BY THE COUNTY AND THE RECEIPT SHOWING THAT FEES | | DUE HAVE BEEN PAID ARE TO BE PROVIDED. | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2017-01-13 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-01-13 |
Time |
15:46 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-01-11 |
Time |
07:49 |
Sent To |
|
|
Notes |
2017-01-13 15:50:45 | MECHANICAL PROVISOS: | | PERMIT #16070715 | | 1/13/17 | | | | 1) REVISE SHEETS M204, M206, M208, M502, M503, M504, | | M505, M506, M507, & M601 TO SHOW ALL OUTSIDE AIR DUCT | | RUNS AND REQUIRED AUTOMATIC SHUTOFF DAMPERS. | | | | 2) PROVIDE REFRIGERANT PIPING RISER DIAGRAMS FOR THE | | SPLIT AC SYSTEMS | | | | 3) FINAL COMMISSIONING REPORT: | | A REPORT OF TEST PROCEDURES AND RESULTS IDENTIFIED AS | | "FINAL COMMISSIONING REPORT" SHALL BE DELIVERED TO THE | | BUILDING OWNER AND SHALL INCLUDE: | | 1. RESULTS OF FUNCTIONAL PERFORMANCE TESTS. | | 2. DISPOSITION OF DEFICIENCIES FOUND DURING TESTING, | | INCLUDING DETAILS OF CORRECTIVE MEASURES USED OR | | PROPOSED. | | 3. FUNCTIONAL PERFORMANCE TEST PROCEDURES USED DURING | | THE COMMISSIONING PROCESS INCLUDING MEASURABLE CRITERIA | | FOR TEST ACCEPTANCE, PROVIDED HEREIN FOR REPEATABILITY. | | EXCEPTION: DEFERRED TESTS WHICH CANNOT BE PERFORMED AT | | THE TIME OF REPORT PREPARATION DUE TO CLIMATIC | | CONDITIONS. | | | | 4) PROVIDE A SIGNED AND SEALED COPY OF THE SMOKE | | CONTROL SYSTEM RATIONAL ANALYSIS BY JAMES S. LUKE P.E. | | COMMISSIONING OF THE SMOKE CONTROL SYSGTEMS REQUIRED AT | | FINAL INSPECTION. | | | | 5) SEPARATE PERMITS ARE REQUIRED FOR FIRE SPRINKLER, | | FIRE SUPPRESSION, KITCHEN HOOD EXHAUST SYSTEMS, AND | | WALK-IN COOLERS AND FREEZERS. | | | | 6) REQUIRED SUBMITTALS: | | A) STAIRWAY PRESSURIZATION FANS. | | B) CORRIDOR EXHAUST FAN. | | C) SMOKE EXHAUST DUCTWORK. | | D) FIRE/SMOKE AND FIRE DAMPERS. | | E) WINDLOAD ENGINEERING FOR INSTALLATION OF ALL ROOFTOP | | MECHANICAL EQUIPMENT, CURBS, STANDS, | | DUCTS, AND SUPPORTS | | F) MOTORIZED DAMPERS. | | G) OUTSIDE AIR AND EXHAUST LOUVERS AND TERMINATION | | CAPS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2016-11-17 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-11-17 |
Time |
16:51 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-11-15 |
Time |
15:03 |
Sent To |
|
|
Notes |
2016-11-17 16:54:14 | 2ND REVIEW FBC-2014 MECHANICAL | | PERMIT #16070715 | | 11/16/17 | | | | 1) REFER TO PAGE 11 OF THE SMOKE CONTROL RATIONAL | | ANALYSIS AND PROVIDE SUBMITTALS FOR ALL OF THE SMOKE | | CONTROL FANS AND DAMPERS WITH SHOP DRAWING APPROVAL | | SIGNATURES BY THE ENGINEER OF RECORD. PLACE NOTES IN | | THE FAN SCHEDULES CORRELATING TO THE REQUIREMENTS | | LISTED FOR SMOKE-CONTROL FANS INCLUDING UL LISTINGS AND | | ITEMS 1.A, B, & C IN THE ANALYSIS. PROVIDE AN EQUIPMENT | | SCHEDULE ON THE PLANS FOR ALL DAMPERS INVOLVED WITH THE | | SMOKE CONTROL SYSTEM. | | | | 2) ON PAGE 4 OF THE RATIONAL ANALYSIS UNDER ITEM II | | SYSTEM PURPOSE, THE LOCATION OF THE BUILDING IS | | INCORRECTLY IDENTIFIED AS MIAMI, FL. AND ATTACHMENT C | | IS ALSO INCORRECTLY LISTING DESIGN CONDITIONS FOR | | MIAMI. | | | | 3) THE RATIONAL ANALYSIS DOES NOT INCLUDE ANY DESIGN | | AND CONTROL OPERATION INFORMATION FOR THE TOWER | | CORRIDOR SMOKE CONTROL AND EXHAUST SYSTEMS AS DEPICTED | | ON SHEET M703. THESE SYSTEMS INVOLVE THE USE OF THE DOA | | UNITS WHICH ARE PROVIDING BOTH THE OUTSIDE AIR TO THE | | CORRIDORS AND APARTMENTS, AND ALSO MAKE-UP AIR FOR THE | | SMOKE EXHAUST AND PRESSURIZATION OF THE CORRIDORS. | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS: | | | | A) IT APPEARS BY THE NOTES IN THE SEQUENCE OF OPERATION | | THAT ALL CORRIDORS WILL BE PRESSURIZED DURING AN ALARM, | | INCLUDING THE CORRIDOR AT THE FLOOR OF INCIDENT WHICH | | IS ALSO BEING EXHAUSTED. IS THIS CORRECT? | | | | B) PRESSURIZATION OF THE APARTMENTS IS NOT INDICATED IN | | THE SEQUENCE OF OPERATION ON M703, HOWEVER THE NOTES BY | | THE DOA TA-1 & TA-2 RISER DRAWINGS ON M702 INDICATE THE | | SYSTEMS ARE ALSO INCLUDED IN THE SMOKE CONTROL | | SEQUENCE- PLEASE CLARIFY. | | | | C) REFER TO SECTION 909.10 (513.10- FMC) WHICH REQUIRES | | THE DOA'S TO BE "SUITABLE FOR THE PROBABLE EXPOSURE | | TEMPERATURES THAT THE RATIONAL ANALYSIS INDICATES". | | PROVIDE DATA INDICATING THE SELECTED UNITS ARE IN | | COMPLIANCE. | | | | D) REFER TO SECTION 909.10.5 (513.10.1) WHICH REQUIRES | | A MINIMUM OF TWO BELTS FOR THE DOA FANS (IF THE FANS | | ARE BELT DRIVEN). | | | | E) REFER TO SECTION 909.10.2 AND VERIFY THE SPECIFIED | | DUCTWORK FOR THE SYSTEMS ARE IN COMPLIANCE FOR | | TEMPERATURE AND DESIGN PRESSURE RATINGS. | | | | 4) REFER TO SECTION 403.4.7 FBC-14 BUILDING AND | | INDICATE HOW SMOKE REMOVAL WILL BE ACCOMPLISHED AT | | FLOORS 1-11 INCLUDING THE EAST AND WEST LINER | | APARTMENTS. PROVIDE DETAILS ON THE PLAN AND NOTES IN | | THE RATIONAL ANALYSIS. | | | | 5) REVISED ENERGYGAUGE PERFORMANCE COMPLIANCE | | SUBMITTAL: | | | | A) 2ND REQUEST FOR OWNER/AGENT SIGNATURE TO BE PROVIDED | | ON PAGE 3. | | | | B) COOLING CAPACITIES SHOWN IN THE CALCS FOR AC E-1, AC | | E-2, AC E-3, AC 1-C, AC 2-F, & AC 2D DO NOT MATCH | | CAPACITIES SHOWN IN THE SCHEDULE ON M1301. | | | | C) COOLING AND HEATING CAPACITIES FOR FCU-2-2 SHOWN IN | | THE CALCS DON'T MATCH THE CAPACITIES SHOWN IN THE | | SCHEDULE (COOLING IN THE CALCS- 8100 BTUH, COOLING IN | | THE SCHEDULE- 120,000 BTUH). | | | | D) FCU 1-6 IS IN THE CALCS BUT IS NOT INDICATED IN THE | | SCHEDULE. | | | | E) AHU'S-12-1,2,3,4,5 & 6 ARE LISTED AS HEAT PUMPS IN | | THE CALCS BUT LISTED AS STRAIGHT COOL UNITS WITH HEAT | | STRIPS IN THE SCHEDULE. | | | | F) FCU-25-1 IS IN THE CALCS BUT NOT IN THE SCHEDULE. | | | | G) UNABLE TO VERIFY DIGITAL SIGNATURES TO BE VALID. | | | | 6) AC CALCULATIONS: | | | | A) THE LT SYSTEMS (36.6MBH/ 7.5KW) SELECTED FOR UNITS | | W01- W04 ARE OVERSIZED FOR COOLING AND HEATING PER THE | | CALCS. | | | | B) THE L-2 SYSTEM SELECTED FOR W205 & W206 ARE | | OVERSIZED FOR COOLING. | | | | C) THE 2-F SYSTEM FOR TOWER UNIT 18 IS OVERSIZED FOR | | COOLING. | | | | D) THE 2-F SYSTEM FOR THE PENTHOUSE IS UNDERSIZED FOR | | COOLING. | | | | E) DIGITAL SIGNATURES REQUIRED ON THE CALCULATIONS. | | | | 7) PLEASE PLACE THE EXHAUST FAN SIZING CALCULATION | | TABLE THAT WAS ATTACHED TO THE NARRATIVE ON SHEET | | M1303. | | | | 8) M201: THE CORRIDOR SHALL NOT BE USED TO CONVEY | | RETURN AIR. PLEASE REMOVE THE RETURN TRANSFERS FROM THE | | MAIL AND PACKAGE ROOMS. | | | | 9) M201: 2ND REQUEST FOR REQUIRED O/A INLET AND EXHAUST | | OUTLET CLEARANCES TO BE NOTED ON THE PLANS WITH | | MEASUREMENTS- SEE SECTION 501.3.1. THIS REQUEST | | INCLUDES THE GENERATOR RADIATOR EXHAUST. | | | | 10) M201: FIRE DAMPER REQUIRED FOR THE AIR INTAKE | | LOUVER IN THE 2HR. FIRE-RATED GENERATOR ROOM WALL- | | SECTION 607.5.2 FBC-14 MECHANICAL, SECTION 4.1.2.1.5 | | NFPA 37. | | | | 11) M201: THE NARRATIVE RESPONSE INDICATES AN EXHAUST | | VENTILATION RATE OF 1 CFM/SF FOR THE GENERATOR ROOM, | | HOWEVER THE ROOM HAS NOT BEEN EQUIPPED WITH A FAN. | | | | 12) M201: SHOW LOCATIONS OF ACCESS PANELS FOR ANY FCU'S | | INSTALLED ABOVE HARD CEILINGS, AND PROVIDE DETAILS FOR | | CONSTRUCTION OF THE PANELS. | | | | 13) M201: CLARIFY WHICH EXCEPTION TO THE CODE IS BEING | | USED FOR THE OMITTED FIRE DAMPERS FOR DUCTS PENETRATING | | THE FIRE-RATED CORRIDOR AND ROOM WALLS. THE FBC SECTION | | 716.5.2 EXCEPTION CITED IN THE NARRATIVE IS FROM THE | | 2010 CODE AND IS NOT APPLICABLE. PLACE THE SECTION(S) | | NUMBERS IN THE NOTES AND PROVIDE A FIRESTOPPING | | ASSEMBLY FOR THE PENETRATIONS. | | | | 14) M201: WHERE FIRE AND FIRE/SMOKE DAMPERS ARE | | PROVIDED, PLACE A NOTE INDICATING WHERE DETAILS FOR | | INSTALLATION OF THE DAMPERS AND EQUIPMENT SCHEDULES CAN | | BE FOUND IN THE PLANS. | | | | 15) M203: LABEL THE AC SYSTEMS SHOWN IN THE LEASING | | OFFICE AND ADJOINING ROOMS. | | | | 16) M203: REFER TO COMMENTS 12, 13, & 14 ABOVE AND SHOW | | COMPLIANCE ON THIS LEVEL. | | | | 17) M203: IN REFERENCE TO COMMENT #11 FROM THE 1ST | | REVIEW REGARDING THE GREASE DUCT TERMINATION AT THE | | GARAGE WALL, PLEASE PLACE THE RESPONSE NOTES TO THIS | | COMMENT IN THE NARRATIVE ON THE PLAN AT THE GREASE DUCT | | LOCATION. | | | | 18) COMMENT #11B & 12 FROM THE 1ST REVIEW STILL EXISTS: | | AS PREVIOUSLY REQUESTED PROVIDE EXHAUST VENTILATION FOR | | THE TRASH CHUTE VESTIBULES SHOWN ON M204, 205, 206, 207 | | & 208. THE CODE DOES NOT MAKE ANY DISTINCTION BETWEEN | | TRASH ROOMS AND TRASH VESTIBULES. THIS COMMENT ALSO | | APPLIES TO THE VESTIBULES IN THE TOWER. | | | | 19) M204: OUTSIDE AIR IS NOT BEING SUPPLIED TO THE TWO | | NORTHERNMOST UNITS AT THE WEST LINER. THE UNIT NUMBERS | | ARE NOT IDENTIFIED (WHICH WAS A PREVIOUS IGNORED | | REQUEST) HOWEVER THEIR FLOOR PLANS ARE TAGGED- 1//M505 | | & 3/M504. | | | | 20) M204, 205, 206, 207, 208, & 209: REFER TO COMMENTS | | 12, 13, & 14 ABOVE AND SHOW COMPLIANCE ON THESE LEVELS. | | | | 21) M210: PLEASE PROVIDE EXTERIOR DUCTWORK | | SPECIFICATIONS IN THE NOTES. | | | | 22) M211: THE EXHAUST FROM THE BIKE STORAGE ROOM MUST | | DISCHARGE TO THE OUTDOORS PER SECTION 501.3. | | | | 23) M212: THE EXHAUST FROM THE POOL EQUIPMENT ROOM AND | | THE TOILET ROOM MUST DISCHARGE TO THE OUTDOORS- SECTION | | 501.3. | | | | 24) M212: PROVIDE VENTILATION FOR THE FIREMAN'S LIFT | | LOBBY 1104. | | | | 25) M212: LABEL ALL OF THE STAIRWELLS. | | | | 26) M212: CLARIFY THE USE OF THE GARAGE 1100 AREA. IT | | DOES NOT APPEAR THAT A CAR CAN ACCESS THE AREA. | | | | 27) M213: MISSING FSD'S: A) 14X8" EXHAUST DUCT CROSSING | | THE FIRE-RATED CORRIDOR AT THE POOL BATHROOM. B) 10X10 | | CORRIDOR TRANSFER AT THE MEN'S R.R. C) 10" ROUND DUCT | | PENETRATING CORRIDOR AT THE FITNESS CENT. D) FLEX DUCTS | | FROM THE YOGA ROOM PENETRATING THE FIRE-RATED CORRIDOR | | LEADING OUT TO THE POOL. E) PLEASE REVIEW ENTIRE FLOOR | | LEVEL AND REVISE TO SHOW LOCATIONS OF ALL REQUIRED | | DAMPERS. | | . | | 30) M213: REFER TO COMMENTS 12, 13, & 14 ABOVE AND SHOW | | COMPLIANCE ON THIS LEVEL. | | | | 31) M503: THE 8" DUCTS SUPPLYING 275 CFMS OF SUPPLY AIR | | IN UNIT 20 APPEAR TO BE UNDERSIZED WHEN CHECKED WITH | | THE TRANE DUCTOLATOR AT 0.1" W.C.. | | | | 32) M504: THE 8" DUCT SUPPLYING 300 CFMS OF SUPPLY AIR | | IN UNITS W01 & W206 APPEAR TO BE UNDERSIZED WHEN | | CHECKED WITH THE TRANE DUCTOLATOR AT 0.1" W.C.. | | | | 33) M505: THE 8" DUCT SUPPLYING 300 CFMS OF SUPPLY AIR | | IN UNITS W02 & W03 APPEAR TO BE UNDERSIZED WHEN CHECKED | | WITH THE TRANE DUCTOLATOR AT 0.1" W.C.. | | | | 34) M506: A) 8" DUCT SUPPLYING 300 CFMS IN UNIT W04 | | UNDERSIZED. B) 8" DUCTS SUPPLYING 275 CFMS OF SUPPLY | | AIR IN UNIT E01 UNDERSIZED. C) 8" DUCT SUPPLYING 500 | | CFMS OF SUPPLY AIR IN UNIT E02 UNDERSIZED. | | | | 35) M507: A SMOKE DETECTOR MUST BE INSTALLED IN THE | | RETURN AIR SYSTEMS OF AC-2F IN ACCORDANCE WITH 606.2.1 | | | | 36) PLEASE PLACE A NOTE ON ALL UNIT PLANS TO INDICATE | | ALL AC CLOSET DOORS SHALL BE OF NON-COMBUSTIBLE | | MATERIALS. A) PROVIDE FL. PRODUCT APPROVALS AND/OR | | MIAMI-DADE NOA'S FOR THE DRYER VENT- SKU-DB-425, AND | | THE EV-2 SHOWN IN THE DRAWINGS. | | | | 37) DEFERRED SUBMITTALS, AS REQUESTED BY THE DESIGN | | TEAM, ARE ACCEPTED FOR WIND LOAD ENGINEERING AND | | INSTALLATION OF ALL EXTERIOR MECHANICAL EQUIPMENT AND | | COMPONENTS, FOR ALL EQUIPMENT AND COMPONENTS ASSOCIATED | | WITH THE SMOKE CONTROL SYSTEM, AND FOR ALL OTHER HVAC | | EQUIPMENT .AND COMPONENTS. PLEASE PROVIDE A DOCUMENT | | LISTING ALL SUBMITTALS TO BE DEFERRED. PLEASE NOTE THAT | | FINAL CO WILL ALSO BE CONTINGENT ON RECEIVING THE | | COMMISSIONING REPORT. | | | | A) DEFERRED SUBMITTAL: 107.3.4.2 DEFERRED SUBMITTALS. | | FOR THE PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS | | ARE DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE | | NOT SUBMITTED AT THE TIME OF THE APPLICATION AND THAT | | ARE TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A | | SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL | | HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION | | DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | OFFICIAL. | | | | B) DEFERRED SUBMITTAL. 2010 FBC 107.3.4.1 PRODUCT | | APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED BY THE | | DCA RULE 9N-03 SHALL BE REVIEWED AND APPROVED IN | | WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL. | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-09-23 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-09-23 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-08-22 |
Time |
16:33 |
Sent To |
|
|
Notes |
2016-09-23 13:56:32 | 1ST REVIEW FBC-2014 MECHANICAL, ENERGY CONSERVATION | | CODES | | PERMIT #16070715 | | ALL ABOARD FLORIDA/ THE BRIGHTON | | 9/22- 9/23/16 | | | | 1) REFER TO SECTION 513.4: A RATIONAL ANALYSIS | | SUPPORTING THE TYPES OF SMOKE CONTROL SYSTEMS TO BE | | EMPLOYED, THEIR METHODS OF OPERATION, THE SYSTEMS | | SUPPORTING THEM AND THE METHODS OF CONSTRUCTION TO BE | | UTILIZED SHALL ACCOMPANY THE SUBMITTED CONSTRUCTION | | DOCUMENTS AND SHALL INCLUDE, BUT NOT BE LIMITED TO THE | | ITEMS INDICATED IN SECTIONS 513.4.1 THROUGH 513.19 | | PLEASE PROVIDE THE ANALYSIS. | | | | 2) REFER TO SECTION C407 FBC-14 ENERGY CONSERVATION. A) | | THE UPLOADED ENERGYGAUGE SUMMIT TOTAL BUILDING | | PERFORMANCE COMPLIANCE DOCUMENT SHALL BE SIGNED BY THE | | DESIGN PROFESSIONALS AND THE OWNER/AGENT. THE DOCUMENT | | SHALL ALSO BEAR THE ELECTRONIC SIGNATURE OF THE DESIGN | | PROFESSIONAL. B) THE SUBMITTED AC PEAK COOLING LOAD | | CALCULATIONS ARE INCOMPLETE, AND NOT IN COMPLIANCE WITH | | THE REQUIREMENTS FOR THERMAL BLOCK LOAD DESIGN AS | | LISTED UNDER SECTIONS C407.5.2 THROUGH C407.5.2.3. | | PLEASE REVIEW AND PROVIDE CALCULATIONS AND DIAGRAMS IN | | COMPLIANCE. C) COMPLETE THE MANDATORY REQUIREMENTS | | CHECK LIST ON PAGE 35 OF THE SUBMITTAL. | | | | 3) REFER TO SECTIONS C408 .1 THROUGH C408.3 AND PROVIDE | | A COMMISSIONING PLAN FOR THE MECHANICAL AND ELECTRICAL | | POWER AND LIGHTING SYSTEMS. | | | | 4) THE ENERGYGAUGE SUBMITTAL DOC INDICATES RTU #4 AT | | 85,000 BTUH, HOWEVER IT IS LISTED AS 71,000 IN THE AC | | SCHEDULE ON SHEET M1301. | | | | 5) THE ENERGYGAUGE DOC LISTS HEATING COMPLIANCE DATA | | FOR THE VRF-FCU?S, HOWEVER THERE IS NO HEAT SHOWN IN | | THE SCHEDULE FOR THESE UNITS ON M1302. | | | | 6) M1303 & M501: PLEASE CLARIFY HOW UNITS AC-2-A, 2-B, | | & 2-C CAN HAVE POSITIVE RESULTANT AIR BALANCES WHEN | | THERE IS MORE EXHAUST CFMS IN THE UNITS THEN O/A CFMS. | | PLEASE NOTE THE REQUIRED KITCHEN EXHAUST CFMS ARE NOT | | INCLUDED IN THE CALCULATIONS, AND NO EXHAUST IS SHOWN | | ON THE FLOOR PLANS. ADDITIONAL ISSUES CONCERNING THE | | UNIT MECHANICAL SYSTEMS WILL BE ADDRESSED LATER IN THIS | | REVIEW. | | | | 7) M1303: CONCERNING THE AIR BALANCE SCHEDULE, PLEASE | | CLARIFY HOW THE "ACTUAL E.A. CFM" HAS BEEN CALCULATED. | | | | 8) M1301: CLARIFY HOW EACH OF THE EXHAUST FANS SHOWN IN | | THE SCHEDULE WERE SIZED- PROVIDE CALCULATIONS IN | | ACCORDANCE WITH TABLE 403.3, OR ASHRAE-62.1. | | | | 9) M201: A) FIRE DAMPER MISSING AT THE 8 FT. DUCT | | PENETRATING THE LOBBY/PACKAGE RM WALL. B) PROVIDE O/A | | TO THE FIRE COM. ROOM. C) VERIFY REQUIRED CLEARANCES | | FOR ALL AIR INTAKES ON THE NORTH WALL- SEE SECTION | | 401.4. INDICATE HOW THE INTAKE OPENINGS WILL BE | | PROTECTED- SEE SECTION 401.5. | | D) VERIFY REQUIRED CLEARANCES FOR THE GENERATOR AND ALL | | OTHER EXHAUST TERMINATIONS ON THE NORTH WALL PER | | SECTION 501.3.1 & 501.3.1.1. PLEASE NOTE A301 SHOWS AN | | ACCESSIBLE ROUTE ALONG THE NORTH SIDE OF THE BUILDING. | | E) PROVIDE EXHAUST VENTILATION CALCULATIONS FOR THE | | GENERATOR ROOM. | | 10) ADVISORY: PLEASE IDENTIFY ALL ROOMS AND SPACES, AND | | STAIRWELLS ON THE MECHANICAL PLANS AND, IF POSSIBLE, | | OVERLAY ALL FIRE-RATED WALLS AND SHAFTS FROM THE LIFE | | SAFETY PLAN. THIS WOULD GREATLY HELP SPEED UP THE | | REVIEW PROCESS. | | | | 11) M203: A) REFER TO SECTION 506.3.13.2 AND INDICATE | | COMPLIANCE FOR THE GREASE EXHAUST TERMINATION SHOWN AT | | THE SOUTH WALL. B) PROVIDE EXHAUST VENTILATION FOR THE | | TRASH ROOM- SEE TABLE 6-4 ASHRAE 62.1. | | | | 12) M204, M205, M206, M207, M208: PROVIDE EXHAUST | | VENTILATION FOR THE TRASH ROOMS- TABLE 6-4 ASHRAE 62.1. | | | | 13) M205, M207, M209, M210, M211, M212: REQUIRED | | VENTILATION FOR THE FIREMAN?S LIFT LOBBIES NOT SHOWN. | | | | 14) M206: SHOW THE CONDENSATE PIPING RUN AND DISCHARGE | | LOCATION FOR FCU-5-3. | | | | 15) M208: SHOW THE CONDENSATE PIPING RUN AND DISCHARGE | | LOCATION FOR FCU-7-1. | | | | 16) M210 & M1301: CORRECT THE DOAS-5 LOCATION IN THE | | SCHEDULE TO LEVEL 9 ROOF. | | | | 17) M210: PROVIDE A DUCT SMOKE DETECTOR SYMBOL AT THE | | RETURN AIR DUCT TO RTU-3. | | | | 18) M210: SHOW THE SIZES OF THE BRANCH DUCTS CONNECTING | | TO THE MAIN TRUNK LINE OF DOAS-4 | | | | 19) M210: PROVIDE A KEY NOTE AT EACH DOAS DUCT DROP. | | | | 20) M210: SHOW THE CONDENSATE PIPING RUN AND DISCHARGE | | LOCATION FOR FCU?S 9-1, 9-2, & 9-3. | | | | 21) M210: WIND LOAD TIE DOWN ENGINEERING IS REQUIRED | | FOR INSTALLATION OF THE ROOF TOP MECHANICAL EQUIPMENT | | INCLUDING THE O/A UNITS, RTU?S, CONDENSERS AND | | CONDENSER STANDS, FANS, | | DUCTWORK AND LOUVERS. PROVIDE KEY NOTES ON THE PLAN | | INDICATING WHERE THE DETAILS FOR INSTALLATIONS ARE | | LOCATED, AND SUBMIT FL. PRODUCT APPROVALS AND | | MIAMI-DADE NOA?S FOR THE STANDS, CURBS, AND LOUVER- | | SECTION 301.15 AND FLORIDA DEPARTMENT OF COMMUNITY | | AFFAIRS RULE 9N-3 | | | | 22) M211: SHOW THE CONDENSATE PIPING RUN AND DISCHARGE | | LOCATION FOR FCU-10-1. | | | | 23) M211: INDICATE HOW THE BIKE STORAGE AREA WILL BE | | VENTILATED. | | | | 24) M211: IDENTIFY THE AREA AND THE SHAFTS SHOWN TO THE | | EAST OF STAIR #2. | | | | 25) M212: REFER TO SECTION 304.3.1 AND PROVIDE A | | VESTIBULE FOR THE POOL EQUIPMENT ROOM. A) PROVIDE A | | FIRE DAMPER FOR THE EXHAUST DUCT PENETRATING THE | | FIRE-RATED POOL EQUIPMENT ROOM WALL- SECTION 607.5.2. | | B) REFER TO SECTION 454.1.5.8 FBC-14 BUILDING AND | | INDICATE WHERE THE POOL CHEMICALS WILL BE STORED AND | | THEIR QUANTITIES. C) IDENTIFY THE ROOM OR SPACE TO THE | | NORTH OF THE POOL EQUIPMENT ROOM DOORS. D) REFER TO | | SECTION 304.6 AND PROVIDE THE VERTICAL CLEARANCE | | DISTANCE FROM THE PARKING GARAGE FLOOR TO THE UNDERSIDE | | OF THE POOL EXHAUST DUCT, AND TO THE UNDERSIDE OF CU?S | | 11-1, 12.5-2 & 11-3. E) PROVIDE THE SIZE OF THE DUCTS | | AND DIFFUSERS AT THE MAINTENANCE SHOP AND THE CFM | | CAPACITY. F) PROVIDE VENTILATION FOR THE OPEN STORAGE | | ROOM- TABLE 403.3/ASHRAE 62.1-2010. G) SHOW THE | | CONDENSATE PIPING RUN AND DISCHARGE LOCATION FOR | | FCU-7-2. H) PLEASE NOTE THAT A SEPARATE PLAN AND PERMIT | | ARE REQUIRED FOR THE POOL. ADVISORY: GAS POOL HEATERS | | WILL REQUIRE COMBUSTION AIR AND EXHAUST VENTILATION. IT | | MAY BE HELPFUL TO SHOW THESE DETAILS ON THE MAIN PLANS. | | | | 26) M213: LABEL BOTH THE RTU-1 & 2 SUPPLY AND RETURN | | RISERS AT THE SHAFT LOCATIONS. A) DUCT SMOKE DETECTORS | | ARE REQUIRED TO BE INSTALLED IN THE RETURN AIR RISER OF | | RTU-1 AT EVERY STORY PER SECTION 606.2.3. SHOW A DS | | DETECTOR SYMBOL AT ALL LOCATIONS ON THE MECHANICAL | | PLANS AND ON THE RISER DRAWING M702. B) THE TOTAL CFM | | SUPPLY ON THE FLOOR PLAN FOR RTU-1 DOES NOT MATCH THE | | TOTAL SHOWN ON THE RISER DRAWING. C) THE CORRIDOR SHALL | | NOT BE USED TO CONVEY RETURN AIR PER SECTION 601.2. | | REMOVE ANY TRANSFER DUCTS INTO THE CORRIDOR AND PROVIDE | | DUCTED RETURNS. | | | | 27) M213: THE TWO 12X8 DUCTS SHALL NOT PENETRATE INTO | | STAIR #2 (SEE SHEET A212) IN ACCORDANCE WITH SECTION | | 1022.5 FBC-14 BUILDING. PLEASE RELOCATE THE DUCTS. | | | | 28) M213: PROVIDE THE FLEX DUCT SIZES FOR AHU-12-6. A) | | LABEL THE O/A DUCT AND PROVIDE A SHUTOFF DAMPER PER | | SECTION C403.2.4.4 FBC-14 ENERGY CONSERVATION. B) FSD | | MISSING FOR THE 12X8 DUCT PENETRATING THE FIRE-RATED | | AHU-12-6 CLOSET WALL. | | | | 29) M213: PROVIDE SYMBOLS OR KEYNOTES AT THE LOCATIONS | | OF THE MAIN SUPPLY TRUNKS UP TO AHU'S 12-1, 12-2, & | | 12-3. A) LABEL ALL FLEX DUCT SIZES IN THE FITNESS | | CENTER. B) LABEL THE O/A DUCTS FOR AHU?S 12-1, 12-2, & | | 12-3 AND PROVIDE SHUTOFF DAMPERS. | | | | 30) M213: PROVIDE DUCT SIZES FOR FCU-12-1, A) LABEL ALL | | THE FLEX DUCT SIZES FOR AHU-12-4 & 12-5. B) PROVIDE | | SHUTOFF DAMPERS FOR THE O/A INTAKE DUCTS TO AHU-12-4 & | | 12-5. | | | | 31) M213: PROVIDE EXHAUST VENTILATION FOR THE TRASH | | ROOM. | | | | 32) M214: LABEL THE RTU-1 & 2 SUPPLY AND RETURN RISERS. | | A) PROVIDE A DUCT SMOKE DETECTOR SYMBOL AT THE RETURN | | AIR RISER OF RTU-1. B) EXHAUST VENTILATION IS REQUIRED | | FOR THE DOG PARK (IF IT IS AN ENCLOSED ROOM), AND THE | | DOG WASH ROOM- TABLE 403.3. C) SHOW THE CONDENSATE | | PIPING PUNS AND DISCHARGE LOCATIONS FOR FCU-12.5-1, | | AHU-12-1, 12-2, & 12-3. D) PROVIDE VENTILATION FOR THE | | ELEC RM 12.509, MECH VEST. 12.510, MECH RM.12.507, AND | | EXHAUST VENTILATION FOR THE TRASH ROOM. | | | | 33) M215: LABEL THE RTU-1 & 2 SUPPLY AND RETURN RISERS. | | A) PROVIDE A DUCT SMOKE DETECTOR SYMBOL AT THE RETURN | | AIR RISER OF RTU-1. B) PROVIDE EXHAUST VENTILATION FOR | | THE TRASH ROOM. | | | | 34) M216: LABEL THE RTU-1 & 2 SUPPLY AND RETURN RISERS. | | A) PROVIDE A DUCT SMOKE DETECTOR SYMBOL AT THE RETURN | | AIR RISER OF RTU-1. B) PROVIDE EXHAUST VENTILATION FOR | | THE TRASH ROOM. | | | | 35) M217A & M217B: THERE ARE MULTIPLE FSD'S MISSING | | WHERE O/A DUCTS ARE PENETRATING THE FIRE-RATED CORRIDOR | | WALLS- PLEASE CORRECT. | | | | 36) M218: WIND LOAD TIE DOWN ENGINEERING IS REQUIRED | | FOR INSTALLATION OF THE ROOF TOP MECHANICAL EQUIPMENT | | INCLUDING THE O/A UNITS, RTU'S, CONDENSERS AND | | CONDENSER STANDS, FANS, | | DUCTWORK AND LOUVERS. PROVIDE KEY NOTES ON THE PLAN | | INDICATING WHERE THE DETAILS FOR INSTALLATIONS ARE | | LOCATED, AND SUBMIT FL. PRODUCT APPROVALS AND | | MIAMI-DADE NOA'S FOR THE STANDS, CURBS, AND LOUVER- | | SECTION 301.15 AND FLORIDA DEPARTMENT OF COMMUNITY | | AFFAIRS RULE 9N-3. | | | | 37) M218: PROVIDE THE DIMENSIONS OF THE ELEVATOR | | HOISTWAY VENTS AND SIZING CALCULATIONS- SECTION 3004.3 | | FBC-14 BUILDING CONSTRUCTION. INDICATE HOW THE OPENINGS | | WILL BE PROTECTED. | | | | 38) M218: PROVIDE A RISER DIAGRAM FOR EF-2. THIS FAN IS | | PART OF THE SMOKE CONTROL SYSTEM AND IS INCLUDED IN THE | | SEQUENCE ON SHEET M703, HOWEVER I AM NOT SEEING A SHAFT | | OR ANY EXHAUST OPENINGS ON THE FLOORS BELOW IT. | | | | 39) M703: PLEASE CLARIFY WHY THERE IS NO SMOKE CONTROL | | SEQUENCE OF OPERATION FOR FLOORS 1-11. IT APPEARS THAT | | ONLY PRESSURIZED STAIRS WILL FUNCTION IN THAT MODE. HOW | | WILL THE DAMPERS AT THE SHAFTS FOR RTU'S 3 & 4 | | FUNCTION? | | | | 40) SHEETS M501, 502, 503, 504, 505, 506, 507: THE | | FOLLOWING COMMENTS ARE PREDOMINANTLY APPLICABLE TO ALL | | THE RESIDENTIAL UNITS SHOWN ON THE PLANS WITH A FEW | | EXCEPTIONS. PLEASE REVIEW AND REVISE ACCORDINGLY: | | A) AC CLOSET DOORS SHALL BE NON-COMBUSTIBLE- SECTION | | C403.2.7.2 FBC-14 ENERGY CONSERVATION | | B) SHUTOFF DAMPERS ARE REQUIRED FOR THE O/A DUCTS- | | SECTION C403.2.4.4. | | C) DRYER BOOSTER FANS HAVE BEEN REMOVED FROM THE | | MECHANICAL CODE, AND DRYERS MUST HAVE THE CAPACITIES TO | | EXHAUST FROM THE CONNECTION TO THE TRANSITION DUCT TO | | THE OUTLET TERMINAL- SEE SECTIONS 504.6 THROUGH 504.6.7 | | AND SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE | | DRYERS. | | D) KITCHEN EXHAUST IS REQUIRED AT 25 CFMS PER SQ. FT. | | CONTINUOUSLY OR 100 CFMS PER SQ. FT. INTERMITTENTLY. | | E) BALANCED RETURN AIR IS REQUIRED PER SECTION 601.5 | | ITEMS #1, 2, & 3. MANY OF THE TRANSFER DUCTS AND GRILLS | | ARE UNDERSIZED I.E. 1) A 16X6 GRILL WILL TRANSFER A | | MAXIMUM OF 200 CFMS OF RETURN AIR, HOWEVER IT IS SHOWN | | TRANSFERRING 275 AND 300 CFMS IN SOME OF THE BEDROOMS. | | 2) AN 8? TRANSFER DUCT FROM A BEDROOM IS SHOWN WHERE | | THERE IS AN 8? SUPPLY DUCT- MINIMUM SIZE MUST BE 10?. | | PLEASE REVIEW AND CORRECT. | | | | 41) ADVISORIES: A) PLEASE NOTE THAT ALL PRODUCT | | SUBMITTALS, PRODUCT APPROVALS, AND NOA?S MUST BEAR SHOP | | DRAWING APPROVAL SIGNATURES BY THE DESIGN | | PROFESSIONALS. B) VERIFY ALL PLANS AND DOCUMENTS ON | | FILE, AND ALL RESUBMITTED PLANS AND DOCUMENTS BEAR | | ELECTRONIC SIGNATURES. C) PLEASE NOTE THAT THERE MAY BE | | ADDITIONAL COMMENTS FOLLOWING RESUBMITTAL OF CORRECTED | | PLANS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2017-01-24 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-01-24 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-01-21 |
Time |
04:59 |
Sent To |
|
|
Notes |
2017-01-24 14:04:48 | PLUMBING PROVISO: THE PROVENT PLUMBING DESIGN SYSTEM | | SHALL BE REVIEWED BY PROVENT DESIGN SERVICES AND | | DOCUMENTATION OF SUCH REVIEW AND APPROVAL SHALL BE | | SUBMITTED TO THE CITY OF WEST PALM BEACH BUILDING | | DIVISION FOR REVIEW AND ACCEPTANCE PRIOR TO THE FIRST | | PLUMBING ROUGH INSPECTION. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2016-12-06 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-12-06 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-11-19 |
Time |
05:48 |
Sent To |
|
|
Notes |
2016-11-27 08:22:14 | PLUMBING PLAN REVIEW - 2ND REVIEW - 11/19/16. | | | | 1) UNITS WITH STACKED WASHER/DRYERS SHALL PROVIDE | | ACCESS TO THE WATER SHUTOFF VALVES FOR THE APPLIANCE | | PER 2014 FBC-PLUMBING SEC.606.3. SHOW ON THE PLANS HOW | | COMPLIANCE WILL BE ACHIEVED. | | 2) SHT. A312 - THE DOOR ON THE AMBULATORY STALL IN THE | | WOMEN'S RESTROOM SHALL SWING OUT. 2014 FBC-ACCESS. | | SEC.604.8.2.2. THE GRAB BARS SHALL BE A MINIMUM OF 42 | | INCHES. FAC SEC.604.5.1. | | 3) SHT. A550 - IDENTIFY THE ACCESSIBLE URINAL ON THE | | PLAN AND SHOW THE REQUIRED 30 INCH BY 48 INCH CLEAR | | FLOOR SPACE FOR THE URINAL. FAC SEC.213.3.3, 605. | | 4) SHT. A500 - DETAIL 6 - SHOW THE INSIDE CLEAR | | DIMENSIONS ( LXW ) FOR THE SHOWER. WPB AMEND. TO FBC | | SEC. 107.2.1. | | 5) SHT.A500 - DETAIL #6 - THE DEPTH OF THE LAVATORIES | | SHALL NOT EXCEED 24 INCHES PER THE FHA DESIGN MANUAL. | | INDICATE THE MAXIMUM DEPTH ON THE PLANS. | | 6) SHT. A500 - DETAIL #6 - THE LAVATORY MAY OVERLAP THE | | CLEAR FLOOR SPACE FOR THE SHOWER A MAXIMUM OF 6 INCHES | | IF THE SHOWER IS A MINIMUM OF 42 INCHES IN LENGTH PER | | THE FHA DESIGN MANUAL.THE PORTION OF THE LAVATORY THAT | | OVERLAPS THE CLEAR FLOOR SPACE MUST HAVE KNEE SPACE | | BELOW OR A REMOVABLE VANITY CABINET. THIRTY-SIX INCHES | | OF THE STALL ENTRANCE MUST ALWAYS REMAIN CCLEAR FOR | | MANEUVERING AND TRANSFERS PER THE FHA DESIGN MANUAL. | | **NOTE THAT THE PERPENDICULAR APPROACH TO THE TUB SHOWN | | IN DETAIL 6 IS APPLICABLE DESIGN SPECIFICATION "A" | | BATHROOMS ONLY. | | 7) SHT. A501 - UNIT 01 - SHOW THE WIDTH DIMENSION | | BETWEEN THE KITCHEN SINK CABINET AND THE BASE CABINET | | ON THE OPPOSITE WALL. COMPLY WITH FHA DESIGN MANUAL. | | 8) SHT. A502 - UNIT 03 - INDICATE ON THE PLAN WHICH | | FIXTURE, THE TUB OR SHOWER, COMPLIES WITH THE FAIR | | HOUSING DESIGN MANUAL GUIDELINES. IF IT IS THE TUB, THE | | CLEAR FLOOR SPACE SHALL BE FLUSH WITH THE CONTROL WALL | | SURFACE PER THE GUIDELINES. THIS IS TO BE SHOWN ON ALL | | "B" UNITS AS THE LOCATION OF THE CLEAR FLOOR SPACE AS | | SHOWN DOES NOT COMPLY WITH THE GUIDELINES. | | 9) SHT. A 502 - CLEARLY SHOW THE DIMENSION OF THE | | TURNING DIAMETER CIRCLE IN THE KITCHEN AND THE | | DIMENSIONS OF THE OTHER CLEAR FLOOR SPACES. A TYPICAL | | ENLARGED FLOOR PLAN FOR EACH BATHROOM SPECIFICATION (A | | OR B ) & KITCHEN SHOWING THE DIMENSIONS OF THE CLEAR | | FLOOR SPACES AND COMPLIANCE WITH THE GUIDELINES ON THE | | PLANS WOULD HELP EXPEDITE THE REVIEW AT RESUBMITTAL. | | WPB AMEND. TO FBC SEC. 107.2.1. | | 10)THE LOCATION OF THE CLEAR FLOOR SPACE FOR THE | | BATHTUBS IN ALL "B" UNITS AS SHOWN DOES NOT COMPLY WITH | | THE GUIDELINES. THE EDGE OF THE CLEAR FLOOR SPACE SHALL | | BE FLUSH WITH THE CONTROL WALL SURFACE PER THE | | GUIDELINES. | | 11) SHT. A508 - THE DEPTH OF THE CHASE ADJACENT TO THE | | WATER CLOSET CANNOT EXCEED 24 INCHES PER THE | | GUIDELINES. CLEARLY SHOW THE DEPTH OF THE CHASE FROM | | THE FACE OF THE REAR WALL AT THE WATER CLOSET TO THE | | FACE OF THE CHASE. | | 12) SHT. A508 - CLEARLY SHOW / DEFINE THE CLEAR FLOOR | | SPACE AND DIMENSIONS OF THE CLEAR FLOOR SPACE FOR THE | | WATER CLOSET ON THE PLANS. AS SHOWN, IT DOES NOT APPEAR | | TO COMPLY WITH THE GUIDELINES. | | 13) SHT.A518 - SHOW THE LENGTH OF THE WING WALL | | ADJACENT TO THE WATER CLOSET IN THE "B" BATHROOM.THE | | WING WALL SHALL NOT EXCEED 24 INCHES PER THE | | GUIDELINES.SEE ALSO SHT. A519. | | 14) SHOW THE DIMENSION BETWEEN THE BASE CABINETS AND | | THE ISLAND IN THE TYPICAL PASS THROUGH KITCHENS. COMPLY | | WITH REQUIREMENT #7 OF THE FHA. | | 15) SHT. A522 & A523 - THE WING WALL ADJACENT TO THE | | WATER CLOSET AND THE BATHTUB ARE ENCROACHING MORE THAN | | 24 INCHES INTO THE CLEAR FLOOR SPACE FOR THE WATER | | CLOSET IN VIOLATION OF THE GUIDELINES AND REQ. #7 OF | | THE FHA. | | 16) SHT. A530 - THE DOOR TO THE LAUNDRY ROOM (T31) | | SHALL PROVIDE A 32 INCH CLEAR OPENING PER THE | | GUIDELINES. | | 17) SHT. A532 - THE DOOR APPEARS TO SWING INTO THE | | CLEAR FLOOR SPACE FOR THE WATER CLOSET, SHOWER AND | | LAVATORY. A 30 INCH BY 48 INCH MINIMUM CLEAR FLOOR | | SPACE SHALL BE PROVIDED OUTSIDE THE SWING OF THE DOOR | | PER THE GUIDELINES. CLEARLY SHOW THIS REQUIRED CLEAR | | FLOOR SPACE OUTSIDE THE SWING OF THE DOOR. | | 18) SHT. A535 - A 30 INCH BY 48 INCH CLEAR FLOOR SPACE | | SHALL BE PROVIDED AT SHOWER STALLS, PARALLEL TO THE | | FIXTURE AND FLUSH WITH THE CONTROL WALL. SHOW THE | | REQUIRED CLEAR FLOOR SPACE ON THE PLAN IN THE BATHROOM | | BY THE LAUNDRY. THE OTHER BATHROOM DOES NOT COMPLY WITH | | DESIGN SPECIFICATION "A" BECAUSE THE CLEAR FLOOR SPACE | | IS NOT PARALLEL TO THE SHOWER AND FLUSH WITH THE | | CONTROL WALL DUE TO THE DOUBLE LAVATORIES. THERE IS NO | | ALLOWANCE FOR A CLEAR FLOOR SPACE PERPENDICULAR TO THE | | SHOWER, ONLY FOR A BATHTUB IN THE "A" SPECIFICATION | | DESIGN. SHOW THE LENGTH OF THE WING WALL ADJACENT TO | | THE WATER CLOSET IN THIS BATHROOM. | | 19) SHT. A535 - THE DOORS FOR THE LAUNDRY ROOM (T30A) | | SHALL PROVIDE A 32 INCH CLEAR OPENING PER THE | | GUIDELINES. | | 20) SHT.A535 -THE POWDER ROOM DOOR SHALL HAVE A 32 INCH | | CLEAR OPENING AND COMPLY WITH THE GUIDELINES FOR | | SWITCHES,OUTLETS AND CONTROLS. | | 21) SHT. A552 - THE BREAK ROOM SINK IN THE LEASING | | OFFICE SHALL COMPLY WITH 2014 FBC ACCESS. SECS. 212 & | | 606. | | 22) SHTS. A553 THROUGH A555 - THERE IS A BOX ON ALL | | THREE SHEETS FOR EMERGENCY OVERFLOW DRAINAGE | | CALCULATIONS BUT THE CALCULATIONS HAVE NOT BEEN DONE | | AND THE INFORMATION IS MISSING. SUBMIT ALL REQUIRED | | INFORMATION IN THESE AREAS FOR THE EMERGENCY OVERFLOW | | DRAINAGE PROVISIONS.WPB AMEND. TO FBC SEC. 107.2.1. | | 23) SHTS. A201 & A601 REFER TO A BATHROOM ON THE FIRST | | LEVEL NEAR THE WEST RESSIDENTIAL LOBBY / WEST ELEVATORS | | BUT IT IS NOT REFERENCED ON SHT. A301. THE UNDERGROUND | | SANITARY FOR THIS BATHROOM IS NOT SHOWN ON SHT. 200A. | | CLARIFY. | | 24) SHT. A1206 - DETAILS #1 & #2 - ARE THESE DETAILS | | FOR THE WATER CLOSETS IN THE COMMON AREA RESTROOMS / | | TOILET ROOMS? IF IN THE COMMON AREAS THE GRAB BARS | | SHALL BE MEASURED FROM THE FINISH FLOOR TO THE TOP OF | | THE GRIPPING SURFACE PER 2014 FBC-ACCESS. 609.4. | | CLARIFY. THE GOVERNING ACCESSIBILITY CODE IN FLORIDA IS | | THE 2014 FBC-ACCESSIBILITY, NOT THE ADA. THE FBC IS AN | | ADA COMPLIANT CODE AND HAS BEEN APPROVED BY THE DOJ. | | 25) SHT. A1206 - DETAIL #5 - THE LENGTH OF THE BACKING | | AT THE TUB SHALL BE 48 INCHES MINIMUM PER THE FHA | | DESIGN MANUAL. | | 26) SHT. A1207 - DETAILS #2 &L #7 - SHOW THE DIMENSIONS | | (LXW) OF THE SCUPPERS. | | 27) THE SANITARY RISERS SHOW A SOVENT DESIGN SYSTEM BUT | | IT IS MY UNDERSTANDING FROM A MEETING THAT A PROVENT | | SYSTEM IS TO BE INSTALLED.IF A PROVENT DESIGN IS TO BE | | UTILIZED, SUBMIT ALL NEW RISER DIAGRAMS DESIGNED USING | | THE PROVENT SYSTEM AND THE DESIGN SPECIFICATIONS AND | | MANUAL.IF THE DESIGN OF THE SANITARY SYSTEM IS INDEED A | | SOVENT SYSTEM, INDICATE THE SYSTEM MANUFACTURER AND THE | | DESIGN STANDARD THAT WAS USED IN THE DESIGN OF THE | | SYSTEM.A COMPREHENSIVE REVIEW WAS NOT DONE ON THE | | SOVENT SYTEM DUE TO THE QUESTION OF THE TYPE OF SYSTEM | | BEING USED. WPB AMEND. TO FBC SEC. 107.2.1 & | | 107.3.5.1.3. | | 28) SHT. M706 SHOWS THE 2 INCH CONDENSATE LINE DRAINING | | INTO AN 1 1/4 INCH AND AN 1 1/2 CONDENSATE LINE. THE | | PIPE SIZE CANNOT BE REDUCED IN THE DIRECTION OF FLOW. | | 2014 FPC SEC.314.2.2. | | 29) SHOW COMPLIANCE WITH 2014 FPC SEC.314.2.3 FOR THE | | REQUIREMENTS FOR AUXILARY AND SECONDARY DRAIN SYSTEMS | | FOR THE CONDENSATE SYSTEMS. | | 30) IDENTIFY THE FLOOR LEVELS ON THE CONDENSATE RISERS. | | WPB AMEND. TO FBC SEC. 107.2.1. | | 31) SHT.P200A - THE 3 INCH SUMP FOR THE ELEVATOR - | | WHERE IS THE PIPING RISER? PLANS REFER TO A "DETAIL" | | FOR FURTHER INFO. IDENTIFY THE DRAWING SHEET NUMBER | | WHERE THIS DETAIL CAN BE FOUND. WPB AMEND. TO FBC SEC. | | 107.2.1. | | 32) IDENTIFY THE FLOOR LEVELS ON ALL RISERS.2ND | | REQUEST.THIS WAS PARTIALLY DONE. WPB AMEND. TO FBC | | SEC.107.2.1 | | 33) THE SPECIFICATIONS FOR THE BACKWATER VALVE ON THE | | CONDENSATE DRAINS HAVE NOT BEEN SUBMITTED AS PREVIOUSLY | | REQUESTED. THIS CAN BE A DEFERRED SUBMITTAL. THE | | SPECIFICATIONS CAN BE SUBMITTED FOR THE REVIEW AT THE | | TIME OF INSTALLATION. | | 34) INDICATE ON THE PLANS WHAT STANDARD / CODE WAS USED | | IN SIZING THE OIL INTERCEPTOR. SUBMIT DETAILS/ COPIES | | OF THE STANDARD USED FOR THE SIZING. WPB AMEND. TO FBC | | SEC. 107.2.1. | | 35) SHTS. 203A, 204A - SUBMIT A DETAIL OF THE SURGE | | TANK AND ASSOCIATED PIPING THAT IS LOCATED ON THE | | SECOND PARKING LEVEL. THE TANK IS NOT SHOWN ON THE | | ARCITECTURAL OR LIFE SAFETY PLANS. CLARIFY.ALSO, | | EXPLAIN THE OPERATIONS OF THE SURGE TANK. SHT. 204A HAS | | A NOTE THAT READS"SET VALVE FOR SLOW DRAIN OFF OF SURGE | | TANK. 24 HOUR MAX." WHERE DOES THIS TANK DRAIN? .WPB | | AMEND. TO FBC SEC. 107.2.1. | | 36) A COMPRHENSIVE REVIEW COULD NOT BE PERFORMED ON THE | | SANITARY AND WATER RISERS. THE METHOD USED TO TAG THE | | RISERS IS EXTRERMELY CONFUSING. I CANNOT FIGURE OUT | | WHAT RISER GOES WHERE OR WHAT METHODOLOGY IS BEING | | USED. PLEASE CONTACT THIS PLAN REVIEWER TO SET UP A | | MEETING TO REVIEW AND DISCUSS THE SANITARY AND WATER | | RISER TAGGING SYSTEM. A RISER TAG LEGEND THAT CLEARLY | | CORRELATES WITH EACH PLUMBING PLAN SHEET AND RISER | | SHALL BE SUBMITTED. | | 37) PLEASE EXPLAIN THE MATCH LINES OF ZONE #1 & ZONE | | #2. | | 38) CLEANOUTS ARE REQUIRED IN THE STORM DRAINAGE SYSTEM | | IN ACCORDANCE WITH FPC SEC.1101.8. | | 39) FULL -OPEN VALVES SHALL BE INSTALLED ON THE BASE OF | | OF EVERY WATER RISER PIPE IN ACCORDANCE WITH THE 2014 | | FPC SEC.606.1 (4). | | 40) A FULL-OPEN VALVE SHALL BE INSTALLED ON THE | | DISCHARGE SIDE OF EVERY WATER METER. FPC SEC. 606.1. | | 41) SUBMIT A COMPLETE UNDERGROUND COLLECTION RISER | | DIAGRAM FOR THE SANITARY SYSTEM SHOWING THE INDIVIDUAL | | RISER BRANCHES WITH TAG NUMBERS THAT CLEARLY REFLECT | | THE SCOPE OF WORK. WPB AMEND. TO FBC SEC. 107.2.1. | | 42) ALL FLOOR DRAINS SHALL BE EQUIPPED WITH TRAP | | PRIMERS. 2014 FPC SEC.1002.4. | | 43) SHT. P301 - NOTE #1 REFERS TO A WATER LINE YET THE | | NOTE IS ALSO LOCATED ON THE 2 1/2 INCH GAS LINE ON THE | | PLAN. CLARIFY. | | 44) THE PLANS NOTE THAT THE PIPE SLOPE FOR PIPE SIZES 8 | | INCH OR LARGER SHALL BE 1/16 OF AN INCH.THE MINIMUM | | SLOPE FOR STORM DRAINAGE PIPING PER FPC TABLE 1106.3 IS | | 1/8 OF AN INCH. CLARIFY. | | 45) POINT OF USE WATER HEATERS SUPPLYING TEMPERED WATER | | SHALL BE EQUIPPED WITH A WATER TEMPERATURE LIMITING | | DEVICE THAT COMPLIES WITH ASSE 1070 THAT LIMITS THE | | TEMPERED WATER TO A MAXIMUM TEMPERATURE OF 110 DEGREES. | | FPC SEC. 607.1.2. | | 46) SHT. P311B - NOTE #2 REFERS TO A 6 INCH WATER LINE | | IN A CHASE BUT THERE IS NO CHASE AND THERE IS NO | | CONTINUATION OF THE WATER LINE. CLARIFY. | | 47) SHT. 314B - NOTE ON PLAN IN MECH. ROOM 12.507 CALLS | | OUT CHASE FOR WATER RISER BUT RISER APPEARS TO BE IN | | DOORWAY. CLARIFY. | | 48) THE DE-AERATOR FITTINGS SHALL BE LOCATED AT THE | | BASE OF THE VERTICAL STACK BEFORE IT ENTERS THE | | HORIZONTAL BUILDING DRAIN. THERE ARE SOME THAT ARE | | LOCATED IN THE STACKS. | | 49) SUBMIT EXPANDED SANITARY RISERS FOR REVIEW. THE | | RISERS ARE DIFFICULT TO REVIEW. WPB AMEND. TO FBC SEC. | | 107.2.1. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | | | | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2016-09-08 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-09-08 |
Time |
10:12 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-08-26 |
Time |
10:30 |
Sent To |
|
|
Notes |
2016-09-08 11:15:53 | 1ST REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | 1. PLEASE INDICATE ON THE PLAN WHICH DESIGN | | SPECIFICATION FOR THE BATHROOMS YOUR USING FOR THE FHA. | | PER WPB AMEND. TO FBC 107.2.1 | | | | 2.SHT. A550 AMBULATORY TOILET STALLS IN WOMENS AMENITY | | BATHROOMS SHALL BE MIN 35IN AND 37IN MAX WIDE. PER FBC | | ACC 604.8.2.1 | | | | 3. IF AMENITY BATHROOMS SERVE THE ASSEMBLY OCCUPANCY | | THEY SHALL COMPLY WITH FBC PL 403.1.3 POTTY PARITY. | | IN ASSEMBLY OCCUPANCIES, RESTROOMS WHICH ARE OPEN TO | | THE PUBLIC MUST HAVE A RATIO OF 3:2 WATER CLOSETS | | PROVIDED FOR WOMEN AS THE COMBINED TOTAL OF WATER | | CLOSETS AND URINALS PROVIDED FOR MEN, UNLESS THESE ARE | | TWO OR FEWER SUCH FIXTURES FOR MEN, IN ACCORDANCE WITH | | SECTION 553.86, FLORIDA STATUTES. | | | | 4. DOORS IN BATHROOM S 0-201,1206,1207 SHALL COMPLY | | WITH FBC ACC 603.2.3 DOOR SWING. | | DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR | | CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS SHALL BE | | PERMITTED TO SWING INTO THE REQUIRED TURNING SPACE. | | | | 5. SHT A1206 DETAIL #3 REINFORCING FOR GRAB BARS IN THE | | SHOWERS SHALL BE MAX 32IN TO THE BOTTOM O.F.F. AND A | | MIN 38IN TO THE TOP. PER FHA CH.6 PG.6.12 | | | | 6. SHT.A1206 REINFORCEMENT FOR GRAB BARS AT TOILET | | SHALL BE MAX 32IN TO THE BOTTOM O.F.F. AND A MIN 38IN | | TO THE TOP. PER FHA CH.6 PG.6.4-5 | | | | 7. SHT.P200A LABEL SANITARY PIPING FOR BATHROOM IN | | LOBBY. PER WPB AMEND TO FBC 107.2.1 | | | | 8. IN THE LEASING OFFICE AND LOBBY SEPARATE FACILITIES | | ARE REQUIRED FOR EACH SEX. FBC ACC. 403.2 SEPARATE | | FACILITIES. | | WHERE PLUMBING FIXTURES ARE REQUIRED, SEPARATE | | FACILITIES SHALL BE PROVIDED FOR EACH SEX. | | | | 9. PLEASE LABEL FLOOR LEVELS ON SANITARY RISER | | DIAGRAMS. PER WPB AMEND. TO FBC 107.2.1 | | | | 10. PROVIDE DETAIL FOR WASH-RING IN TRASH CHUTE. PER | | WPB AMEND. TO FBC 107.2.1 | | | | 11. PROVIDE TAG NUMBERS ON EACH STACK SHTS. P201A THRU | | P219B. PER WPB AMEND. TO FBC 107.2.1 | | | | 12. PLEASE INDICATE ON THE PLAN THE SLOPE OF ALL | | HORIZONTAL STORM AND SANITARY PIPING. PER WPB AMEND. TO | | FBC 107.2.1 | | | | 13. PROVIDE MANUFACTURE SPECS FOR BACKWATER VALVE ON | | CONDENSATE DRAINS. PER WPB AMEND. TO FBC 107.2.1 | | | | 14. PROVIDE DETAIL FOR EMERGENCY OVER FLOW SCUPPER. PER | | WPB AMEND. TO FBC 107.2.1 | | | | 15. PLEASE PROVIDE SIZING CALCULATIONS FOR THE OIL SAND | | SEPARATOR. PER WPB AMEND. TO FBC 107.2.1 | | | | 16. PLEASE PROVIDE MANUFACTURE SPECS FOR OIL MINDER | | ELEVATOR SUMP PUMP, DOMESTIC WATER PUMP, KITCHEN GREASE | | HEAT TRACE SYSTEM. PER WPB AMEND. TO FBC 107.2.1 | | | | 17.TRAP PRIMERS ARE REQUIRED ON FLOOR DRAINS AND THE | | STAND PIPES FOR ELEVATOR SUMP PUMP AND FIRE SPRINKLER | | BLOW DOWN. PER FBC PL 1002.4 TRAP SEALS. | | EACH FIXTURE TRAP SHALL HAVE A LIQUID SEAL OF NOT LESS | | THAN 2 INCHES (51 MM) AND NOT MORE THAN 4 INCHES (102 | | MM), OR DEEPER FOR SPECIAL DESIGNS RELATING TO | | ACCESSIBLE FIXTURES. WHERE A TRAP SEAL IS SUBJECT TO | | LOSS BY EVAPORATION, A TRAP SEAL PRIMER VALVE SHALL BE | | INSTALLED. TRAP SEAL PRIMER VALVES SHALL CONNECT TO THE | | TRAP AT A POINT ABOVE THE LEVEL OF THE TRAP SEAL. A | | TRAP SEAL PRIMER VALVE SHALL CONFORM TO ASSE 1018 OR | | ASSE 1044. | | | | 18. PLEASE PROVIDE RISER DIAGRAMS FOR CONDENSATE DRAINS | | AND WATER HEATER PAN DRAINS. PER WPB AMEND. TO FBC | | 107.3.5.1.3(13) | | | | 19. ALL THE PLUMBING SHEETS ARE MARKED NOT FOR | | CONSTRUCTION THEY CAN NOT BE APPROVED THIS WAY PLEASE | | CLARIFY. PER WPB AMEND. TO FBC 107.2.1 | | | | | | DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND | | THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON | | RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS. | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2017-01-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-01-17 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-11-19 |
Time |
10:12 |
Sent To |
|
|
Notes |
2017-01-24 14:10:52 | PLUMBING SIGNATURES OK. T.LARGE | 2017-01-17 15:01:26 | PROVISO - ANY NEW SHEETS (IF ANOTHER REVIEW CYCLE IS | | REQUIRED) REQUIRE SIGNATURE VERIFICATION | | | | 1/17/17 VERIFIED B, F, E, P, S (SH) | | | | | 2017-01-13 16:40:42 | CCOLE | | 1/13/17 | | | | 1) THE MECHANICAL PLANS, ENERGY CALCULATIONS, AND AC | | CALCULATIONS BEAR ELECTRONIC SEALS AND SIGNATURES BY | | THE ENGINEER OF RECORD. | | | | 2) THE SMOKE CONTROL RATIONAL ANALYSIS REPORT IS BY | | JAMES S LUKE P.E. IS NOT ELECTROCICALLY SIGNED AND | | SEALED. | | | | | 2016-11-19 08:53:14 | 2ND REVIEW SIGNATURES VERIFIED 11/19 SHILL | | | | SURVEY - S&S OK | | CIVIL - S&S OK (WITH EXCEPTION OF SIGNATURE FOR C204, | | WHICH RENDERS CORRECTLY IN PROJECTDOX. THE PDF HAS AN | | ERROR IN ADOBE. FOR SIGNATURE, REFER TO THE PAPER PLANS | | SUBMITTED TO ENGINEERING DEPT OR TO THE SIGNATURE PDF | | IN THE SIGNATURE DOCUMENTS FOLDER. THIS SHEET IS FOR | | INFORMATION ONLY AND IS NOT REQUIRED FOR THIS PERMIT.) | | LANDSCAPE - PAGES ARE NOT S&S BUT ARE MARKED "NOT FOR | | CONSTRUCTION". THE PAGES APPEAR TO BE INFORMATIONAL | | ONLY. THESE SHEETS WILL BE SUPERSEDED BY A LANDSCAPE | | PERMIT TO BE SUBMITTED SEPARATELY WITH SEPARATE | | APPLICATION, FEES, AND PLANS. | | LANDSCAPE IRRIGATION (LI) SHEETS ARE S&S BUT ARE MARKED | | "NOT FOR CONSTRUCTION." THE PAGES APPEAR TO BE | | INFORMATIONAL ONLY. THESE SHEETS WILL BE SUPERSEDED BY | | AN IRRIGATION PERMIT TO BE SUBMITTED SEPARATELY WITH | | SEPARATE APPLICATION, FEES, AND PLANS. | | | | | | | | | | | 2016-09-12 16:32:39 | 9/12/16 REVIEW #1 DIGITAL SIGNATURE (SH) | | C, L SHEETS NOT DIGITALLY S&S | | LI SHEETS OK | | A, S SHEETS OK | | | | | | | | | | | | |
|
|
Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
Rev No |
2 |
Status |
P |
Date |
2016-08-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-08-18 |
Time |
09:44 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-08-18 |
Time |
09:44 |
Sent To |
|
|
Notes |
2016-08-18 09:45:30 | PER KCONRAD, OK TO USE AGREEMENT FROM FOUNDATION PERMIT | | (16030058) AND ADD STRUCTURE AND BUILDOUT PERMIT | | NUMBERS (16040755, 16070715). ADDED NUMBERS AND ROUTED | | ONE SET TO RECORDS, ONE SET TO KC DESK | | |
|
|
Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-08-17 |
Time |
16:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2017-01-24 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2017-01-24 |
Time |
12:06 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2017-01-24 |
Time |
12:06 |
Sent To |
|
|
Notes |
2017-01-24 12:09:14 | PROVISO: | | NO REVIEW CONDUCTED UNDER THIS SUBMITTAL. IF ANY | | CHANGES INTRODUCED SINCE PREVIOUS APPROVAL AND | | ADDITIONAL REVIEW WILL BE NECESSARY. | | 1. ELECTRIC CAR STATIONS SHALL BE FOR TRAIN STATION | | GARAGE. IF FOR RESIDENTIAL GARAGE REVISED NUMBERS SHALL | | BE PROVIDED TO CONFIRM THE PROJECT COMPLIES WITH | | MINIMUM PARKING REQUIREMENTS. | | ALL PROVISOS INCLUDED IN PREVIOUS APPROVAL STILL | | REMAIN. | | 1. PLEASE PROVIDE INFORMATION REGARDING THE SAFE | | CIRCULATION TO ACCESS VAN ACCESSIBLE PARKING SPACE ON | | FIRST FLOOR OF GARAGE. | | 2. PLEASE IDENTIFY IN A SEPARATE LETTER ALL THE IT/TEL | | , BIKE STORAGE ROOMS AND OTHER ELECTRIC ROOM WITHIN THE | | UPPER LEVELS AND ACKOWLEDGE THEY ARE NOT TO BE USES FOR | | HUMAN OCCUPATION DIFFERENT THAN LISTED. | | 3. PLEASE INCLUDE A NOTE IN THE ARCHITECTURAL DRAWINGS | | STATING THE BIKE STORAGE ROOM IS A NON-CONDITIONED | | SPACE. | | 4. PLEASE INDICATE THE DIMENSIONS OF EACH PARKING SPACE | | TO CONFIRM COMPLIANCE WITH MIN DIMENSIONS WHEN ADJACENT | | TO COLUMNS OR WALLS. | | 5. PLEASE INDICATE THE LOCATION OF GUEST PARKING AND | | RETAIL PARKING WHITHIN THE RESIDENTIAL PARKING AND | | CREATE A TABLE LISTING THE NUMBER OF SPACES DEDICATED | | FOR EACH PLUS THE AAF STATION PARKING. | | 6. PLEASE INCLUDE A NOTE IN THE CIVIL DRAWINGS STATING | | THAT THE SIDEWALK ELEVATION SHALL BE MAINTAINED AS IT | | CROSSES THE GARAGE DRIVEWAY . | | 7. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE | | WITH ALL THE TRAFFIC MITIGATION MEASURES IMPOSED BY THE | | DAC APPROVAL. | | 8. PLEASE SUBMIT A SEPARATE LANDSCAPE PERMIT. | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | APONTE AT 561-822-1439. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2016-12-16 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2016-12-16 |
Time |
15:34 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2016-12-14 |
Time |
16:21 |
Sent To |
|
|
Notes |
2016-12-16 15:43:57 | PROVISO: | | 1. PLEASE PROVIDE INFORMATION REGARDING THE SAFE | | CIRCULATION TO ACCESS VAN ACCESSIBLE PARKING SPACE ON | | FIRST FLOOR OF GARAGE. | | 2. PLEASE IDENTIFY IN A SEPARATE LETTER ALL THE IT/TEL | | , BIKE STORAGE ROOMS AND OTHER ELECTRIC ROOM WITHIN THE | | UPPER LEVELS AND ACKOWLEDGE THEY ARE NOT TO BE USES FOR | | HUMAN OCCUPATION DIFFERENT THAN LISTED. | | 3. PLEASE INCLUDE A NOTE IN THE ARCHITECTURAL DRAWINGS | | STATING THE BIKE STORAGE ROOM IS A NON-CONDITIONED | | SPACE. | | 4. PLEASE INDICATE THE DIMENSIONS OF EACH PARKING SPACE | | TO CONFIRM COMPLIANCE WITH MIN DIMENSIONS WHEN ADJACENT | | TO COLUMNS OR WALLS. | | 5. PLEASE INDICATE THE LOCATION OF GUEST PARKING AND | | RETAIL PARKING WHITHIN THE RESIDENTIAL PARKING AND | | CREATE A TABLE LISTING THE NUMBER OF SPACES DEDICATED | | FOR EACH PLUS THE AAF STATION PARKING. | | 6. PLEASE INCLUDE A NOTE IN THE CIVIL DRAWINGS STATING | | THAT THE SIDEWALK ELEVATION SHALL BE MAINTAINED AS IT | | CROSSES THE GARAGE DRIVEWAY . | | 7. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE | | WITH ALL THE TRAFFIC MITIGATION MEASURES IMPOSED BY THE | | DAC APPROVAL. | | 8. PLEASE SUBMIT A SEPARATE LANDSCAPE PERMIT. | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | APONTE AT 561-822-1439. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2016-09-26 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2016-09-26 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2016-09-26 |
Time |
13:53 |
Sent To |
|
|
Notes |
2016-09-26 14:38:41 | 1. RETAIL DOORS ON EAST SIDE CANNOT SWING OPEN INTO THE | | MINIMUM SETBACK. DOORS SHALL BE RECESSED. | | 2. PLEASE CONFIRM THE VAN ACCESSIBLE SPACE ON 1ST FLOOR | | OF RESIDENTIAL GARAGE IS SAFE FOR USERS AND DO NOT | | CONFLICT WITH TRAVEL LANE. | | 3. LEVEL 2 ENCLOSED STORAGE NEXT TO WEST ELEVATOR BANK | | SHALL BE COUNTED AS FAR. | | 4. SUBMITTED DRAWINGS ARE NOT DIMENSIONED. PLEASE | | SUBMIT PARKING SPACES DIMENSIONED. PARKING SPACES WITH | | COLUMNS OR WALLS ON ONE OR BOTH SIDES ARE REQUIRED TO | | BE WIDER BY ONE FOOT OR TWO FEET FRO BOTH SIDES | | OBSTRUCTIONS. (SEC 94-111(C)(1)). | | 5. WHAT IS THE T/E ROOM NOT INCLUDED IN THE FAR? | | 6. PLEASE PROVIDE A SKETCH INDICATING WHAT ELEVATOR IS | | USING EACH OF THE RESIDENTIAL PARKING LEVELS. IF | | ELEVATOR OR FIREMAN'S LIFT LOBBY IS USED BY ANY OF THE | | RESIDENTS PARKING IT SHALL BE COUNTED AS PART OF THE | | FAR. | | 7. PLEASE LABEL RESIDENTIAL BIKE STORAGE AS | | NON-AIRCONDITIONED SPACE, OTHERWISE IT SHALL BE COUNTED | | AS PART OF THE FAR. | | 8. PLEASE LABEL SPACE ADJACENT TO THE MAINTENANCE SHOP | | IN LEVEL II AS NON-AIRCONDITIONED SPACE, AS IT SHALL | | NOT BE FOR HUMAN OCCUPATION OR STORAGE. | | 9. PLEASE CONFIRM THE RETAIL SPACES ARE DESIGNED FOR | | FUTURE TENANT IMPROVEMENTS FOR RESTROOMS, OR FOOD | | PREPARATION. | | 10. EXTERIOR STAIR RAILING IS SHOWN AS AN OPEN RAILING | | BUT NOTES INDICATE OPAQUE RAILING. APPROVED RENDERINGS | | SHOW TRANSPARENT RAILINGS. | | 11. APPROVED RENDERINGS SHOW HIGH WINDOWS ON THE SOUTH | | ELEVATIONS OF EAST RESIDENTIAL LINER UNITS. WINDOWS NOT | | CURRENTLY SHOWN. | | 12. CASTSTONE VOLUME ON WEST ELEVATION ABOVE | | RESIDENTIAL ENTRANCE HAS BEEN MODIFIED, PLEASE RESTORE | | TO SITE PLAN APPROVAL. | | 13. LEASING OFFICE WINDOWS HAVE BEEN REDUCED IN SIZE | | FROM APPROVED RENDERINGS, PLEASE RESTORE TO SITE PLAN | | APPROVAL. | | 14. FLOOR PLANS INDICATING THE AREAS COUNTED AS FAR AND | | THEIR SQUARE FOOTAGE SHALL BE SUBMITTED. | | 15. PLEASE DETAIL THE FINAL CIRCULATION PATTERN FOR THE | | ALLEY AND THE MODIFICATION AT THE EAST END. | | 16. DRIVEWAYS ELEVATION AT THE SIDEWALK CROSSING SHALL | | BE MAINTAINED AT THE SAME LEVEL THAN THE SIDEWALK, | | PLEASE REVISE CIVIL DRAWINGS. | | 17. PLEASE PROVIDE INFORMATION REGARDING THE TRAFFIC | | MITIGATION MEASURES REQUIRED BY THE DAC APPROVAL. | | 18. PEDESTRIAN CROSSING SHALL BE INDICATED AT THE NORTH | | CROSSING OF EVERNIA STREET AND NEW ACCESS ROAD. | | 19. PLEASE INDICATETHE EXACT MATERIALS PROPOSED FOR THE | | GARAGE SCREENING, TYPE OF SCREENING IN WHICH AREAS | | (COLORED DRAWING TO CLEARLY SHOW?) | | 20. PLEASE PROVIDE A SITE PLAN DRAWINGS SHOWING THE | | FIRST FLOOR USES WITH ACCESS POINTS AND WINDOWS, THE | | STREETSCAPE AND LANDSCAPE. | | 21. THE DETAILS ON THE DIFFERENT TRANSITION MATERIALS | | FOR THE SIDEWALKS AROUND THE PROJECT STILL NEED FURTHER | | DISCUSSION. PROPOSAL IS CREATING A FORTH DESIGN PATTERN | | AT THE ROSEMARY AND EVERNIA CORNER | | 22. PLEASE SUBMIT A SEPARATE LANDSCAPE PERMIT FOR ALL | | LANDSCAPE ON SITE AND A RIGHT OF WAY PERMIT FOR ALL | | ELEMENTS PROPOSED ON RIGHT OF WAY. | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | APONTE AT 561-822-1439. |
|
|
|
Account Summary | Usage Policy | Privacy Policy