Plan Review Stops For Permit 16070476 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2017-11-08 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-11-08 |
Time |
17:13 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-11-08 |
Time |
17:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2017-10-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-10-24 |
Time |
12:49 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-10-24 |
Time |
07:04 |
Sent To |
M |
|
Notes |
2017-10-24 12:55:41 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 3RD REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. THERE ARE THREE PLAN SHEETS LABELED A-1. PLEASE | | RE-LABEL AND RE-SUBMIT. | | 2. PLANS SHOW FIXED WINDOWS. PROVIDE PRODUCT APPROVALS | | FOR THIS TYPE OF WINDOW. | | 3. THE PRODUCT APPROVALS FOR THE SINGLE HUNG WINDOWS DO | | NOT HAVE A MODEL THAT COMPLIES WITH THE SIZE OF SOME | | WINDOWS ON PLAN. | | 4. IDENTIFY MODEL OF WINDOWS AND DOORS TO BE USED ON | | PRODUCT APPROVALS. | | 5. PROVIDE WINDOW AND DOOR SCHEDULE. INCLUDE ROUGH | | OPENINGS, DESIGN WIND LOADS. IDENTIFY LOCATION OF EACH | | WINDOW AND DOOR ON PLAN. | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE WINDOW, AND DOOR SUBMITTALS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED AND MARK VOID. | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2017-02-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-02-23 |
Time |
09:18 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-02-23 |
Time |
09:18 |
Sent To |
|
|
Notes |
2017-02-23 09:21:32 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. ROOFING PERMIT REQUIRED. | | 2. PROVIDE REINFORCING DETAIL FOR NEW BOND BEAMS. | | 3. SELECT NEW IMPACT RATED WINDOWS TO BE INSTALLED FROM | | PRODUCT APPROVAL SUBMITTAL, |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-08-09 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-08-09 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-08-09 |
Time |
14:28 |
Sent To |
E |
|
Notes |
2016-08-09 14:35:54 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER ? PX3169 | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | ACTION: DENIED | | DATE: 8/9/16 | | | | 1. PROVIDE SITE PLAN. | | 2. SCOPE OF WORK EXCEEDS DESCRIPTION ON APPLICATION. | | STRUCTURAL CONCRETE, WALLS AND ROOFING SHOWN ON PLANS. | | 3. STATED VALUE MAY BE LOW. | | 4. ROOFING PERMIT REQUIRED. | | 5. PROVIDE RE-INFORCING DTAIL FOR NEW BOND BEAMS. | | 6. DETAIL 1, PG A-4 INDICATES NEW ROOF RAFTERS. DEMO | | PLANS SHOWS NO WORK IN THIS AREA.. PLEASE CLARIFY. TO | | WHAT EXTENT IS ROOFING BEING REMOVED? | | 7. PROVIDE LANDINGS AT EXTERIOR DOORS. | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH | | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES | | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE | | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE | | FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | DESIGN. (SEE ALSO SECTION 107.3.5). | | | | [A] 109.3 BUILDING PERMIT VALUATIONS. | | THE APPLICANT FOR A PERMIT SHALL PROVIDE AN ESTIMATED | | PERMIT VALUE AT TIME OF APPLICATION. PERMIT VALUATIONS | | SHALL INCLUDE TOTAL VALUE OF WORK, INCLUDING MATERIALS | | AND LABOR, FOR WHICH THE PERMIT IS BEING ISSUED, SUCH | | AS ELECTRICAL, GAS, MECHANICAL, PLUMBING EQUIPMENT AND | | PERMANENT SYSTEMS. IF, IN THE OPINION OF THE BUILDING | | OFFICIAL, THE VALUATION IS UNDERESTIMATED ON THE | | APPLICATION, THE PERMIT SHALL BE DENIED, UNLESS THE | | APPLICANT CAN SHOW DETAILED ESTIMATES TO MEET THE | | APPROVAL OF THE BUILDING OFFICIAL. FINAL BUILDING | | PERMIT VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | R311.3 FLOORS AND LANDINGS AT EXTERIOR DOORS. | | THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH | | EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL NOT BE | | LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A | | MINIMUM DIMENSION OF 36 INCHES (914 MM) MEASURED IN THE | | DIRECTION OF TRAVEL. EXTERIOR LANDINGS SHALL BE | | PERMITTED TO HAVE A SLOPE NOT TO EXCEED 1/4 UNIT | | VERTICAL IN 12 UNITS HORIZONTAL (2-PERCENT). | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2017-11-08 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-11-08 |
Time |
10:43 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-11-08 |
Time |
10:43 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2017-10-05 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-10-05 |
Time |
08:38 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-10-05 |
Time |
08:38 |
Sent To |
|
|
Notes |
2017-10-05 08:38:06 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | PART VIII ELECTRICAL | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. KITCHEN SMALL APPLIANCE CIRCUITS PROVIDED ARE SHOWN | | AS #14 WIRE ON A 20 AMP BREAKER. THERE ARE SEVERAL | | OTHER CIRCUITS IN PANEL SCHEDULE IDENTIFIED LIKE THIS. | | PROVIDE CORRECTION. NEC 310.15(B)(16), 334.80; FBC RE | | TABLE E3702.13, TABLE E3705.5.3 | | 2. DISHWASHER AND DISPOSAL ARE SHOWN IN PANEL SCHEDULE | | AS #12 WIRE ON A 30 AMP BREAKER. PROVIDE CORRECTION. | | NEC 310.15(B)(16), 334.80; FBC RE TABLE E3702.13, TABLE | | E3705.5.3 | | 3. BREAKER FOR WATER HEATER IS STATED AS 30 AMP IN | | PANEL SCHEDULE, WHICH IS TOO LARGE FOR THIS LOAD. | | BREAKER SHOULD BE SIZED AT 125% OF THE LOAD. BASED ON | | THE 4500 WATT STATED, THIS WOULD BE A MAXIMUM BREAKER | | SIZE OF 25 AMPS. PROVIDE CORRECTION. NEC 422.13; FBC | | RE3702.10 | | 4. THE LOAD CALCULATION PROVIDED FOR PANEL IS | | INCORRECT. THE DEMAND FACTORS ARE NOT APPLIED TO EVERY | | LOAD IN PANEL. PROVIDE CORRECTED LOAD CALCULATION AS | | PER THE FBC RESIDENTIAL CODE, SECTION E3602.2. INCLUDE | | ALL LOADS IN THIS CALCULATION. THE CURRENT PANEL | | SCHEDULE SHOWS ONLY 1 AHU/AC SYSTEM. NEC 220, FBC RE | | 3602.2 | | 5. THE RISER DIAGRAM PROVIDED HAS CONFLICTING | | INFORMATION. IT SHOWS A FEED TO A DISCONNECT AND THEN | | TO PANEL A WITH 2/0 WIRE. IT ALSO SHOWS A FEED DIRECTLY | | FROM METER TO PANEL A WITH #1 WIRE. CLARIFY AND/OR | | CORRECT. ADDITIONALLY, IF USING A MAIN DISCONNECT AS | | DRAWN, THE WIRING FROM THE DISCONNECT TO PANEL A | | REQUIRES AN EQUIPMENT GROUNDING CONDUCTOR. REFLECT ALL | | CORRECTED INFORMATION ON POWER PLAN AS WELL, IT | | CURRENTLY ONLY SHOWS A PANEL, NO DISCONNECT OR METER | | CAN. PROVIDE CORRECTION. NEC 250.122; FBC 107.2.1; FBC | | RE 3704.6 | | 6. PROVIDE CORRECTED NOTES AS FOLLOWS: "ALL RECEPTS. TO | | BE TAMPER PROOF AS PER NEC 2010 SEC 406.11". THE 2010 | | NEC DOES NOT EXIST AND SECTION 406.11 IN THE CURRENT | | CODE, THE 2011 NEC, DOES NOT APPLY TO TR RECEPTACLES. | | ALSO; "ELECTRICAL CONTRACTOR TO CONFORM TO 2008 NEC | | BUILDING CODES". THIS IS NOT THE CURRENT CODE. PROVIDE | | CORRECTIONS. FBC PREFACE, 107.2.1; NEC 406.12; FBC RE | | 4002.14 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2017-02-21 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2017-02-21 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2017-02-21 |
Time |
10:33 |
Sent To |
|
|
Notes |
2017-02-21 11:30:38 | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | ELECTRICAL REVIEW COMMENTS. | | | | THE ELECTRIC PLAN SHOWS TWO KITCHENS. PLEASE CLARIFY. | | | | PROVIDE A 20 AMPERE KITCHEN COUNTER TOP RECEPTACLES AS | | REQUIRED FOR ALL COUNTER SPACES. FBC E3901.4 | | | | PROVIDE A 20 AMPERE RECEPTACLE CIRCUIT FOR THE DINING | | AREA/ KITCHEN WALL SPACE. FBC E3901.3 | | | | REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO | | INCLUDE INTERCONNECTED SMOKE ALARMS BOTH WITHIN AND | | OUTSIDE EACH SLEEPING AREA INCLUDING THE SECOND FLOOR. | | IF THE BUILDING HAS GAS APPLIANCES, AN ATTACHED GARAGE | | OR A FIREPLACE, A CARBON MONOXIDE DETECTOR IS REQUIRED | | WITHIN TEN FEET OF EACH ROOM USED FOR SLEEPING. FBC | | R314, 315 | | | | A DEDICATED LAUNDRY BRANCH CIRCUIT AND RECEPTACLE IS | | REQUIRED. FBC E3703.3 | | | | PROVIDE WALL SWITCHED CONTROLLED LIGHTING AT ALL | | ENTRANCES. FBC E3903, | | | | SHOW THE LOCATION OF THE ELECTRICAL PANEL AND MAIN | | DISCONNECTS. FBC E3405, E3603 | | | | ROBERT LECKY | | ELECTRICAL PLANS EXAMINER | | 561-805-6654(OFFICE) | | 561-373-3701(CELL) | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-08-11 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-08-11 |
Time |
09:42 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-08-11 |
Time |
09:09 |
Sent To |
M |
|
Notes |
2016-08-11 10:26:37 | REVIEW 2014 5TH FBC ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | | | | | 1) SHEET E-1, SHOW PROPER GFCI RECEPTACLE SPACING IN | | THE KITCHEN COUNTERTOP PER NEC 210.52(3)(C) | | | | 2) SHEET E-1, THE A/C DISCONNECT IS SHOWN BEHIN THE CU | | PLEASE RELOCATE TO BE IN COMPLIANCE WITH WORKING | | CLEARANCE. NEC 110.26(A)(1) | | | | 3) SHEET E-1, THE RECEPTACLE BY THE CU SHALL HAVE DUAL | | RATING "WP/WR" LISTING IN ACCORDANCE WITH NEC 406.9(B). | | PLEASE ADD SYMBOL TO OUTLET. | | | | 4) SHEET E-1, SMOKE ALAMS NEED TO BE REFLECTED IN BOTH | | "EXISTING & AREA OF REMODEL" TO COMPLY WITH FBC-R 314 & | | 315. | | | | 5) SHEET E-1, AT LEAST ONE WALL SWITCH SHALL CONTROL A | | LIGHTING OUTLET ON THE EXTERIOR SIDE OF OUTDOOR DOORS. | | NEC 210.70(2)(B) | | | | 6) SHEET E-1, PROVIDE A RISER-DIAGRAM TO VERIFY | | ELECTRICAL DISTRUBUTION SYSTEM AND REFLECT PANEL AND | | SERVICE LOCATION ON THE FLOOR PLAN. FBC-107 |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2017-09-29 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2017-09-29 |
Time |
09:44 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2017-09-29 |
Time |
09:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
F |
Date |
2017-02-13 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2017-02-13 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2017-02-13 |
Time |
14:56 |
Sent To |
|
|
Notes |
2017-02-13 14:56:39 | PREVIOUS COMMENTS HAVE NOT BEEN ADDRESSED: | | | | STRUCTURE IS LOCATED IN NORTHWEST HISTORIC DISTRICT. | | PLANS INDICATE CHANGES IN WINDOW OPENINGS. NO WINDOW | | SCHEDULE OR ELEVATIONS WERE PROVIDED TO COMPLETE | | EVALUATION. PLEASE SUBMIT ADDITIONAL INFORMATION. | | CONTACT FRIEDERIKE MITTNER, CITY HISTORIC PRESERVATION | | PLANNER AT 822-1457 FOR ADDITIONAL QUESTIONS. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2016-07-21 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2016-07-21 |
Time |
14:16 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2016-07-21 |
Time |
14:16 |
Sent To |
|
|
Notes |
2016-07-21 14:25:45 | STRUCTURE IS LOCATED IN NORTHWEST HISTORIC DISTRICT. | | PLANS INDICATE CHANGES IN WINDOW OPENINGS. NO WINDOW | | SCHEDULE OR ELEVATIONS WERE PROVIDED TO COMPLETE | | EVALUATION. PLEASE SUBMIT ADDITIONAL INFORMATION. | | CONTACT FRIEDERIKE MITTNER, CITY HISTORIC PRESERVATION | | PLANNER AT 822-1457 FOR ADDITIONAL QUESTIONS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2017-11-08 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-11-08 |
Time |
17:13 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-11-06 |
Time |
15:32 |
Sent To |
I |
|
Notes |
2017-11-07 15:32:25 | RESUB ROUTED TO JPEARSON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-10-25 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-10-25 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-09-20 |
Time |
14:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-03-17 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-03-17 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-01-30 |
Time |
10:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-08-17 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-08-17 |
Time |
12:52 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-07-13 |
Time |
13:27 |
Sent To |
|
|
Notes |
2016-07-14 13:27:29 | LIBRARY |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2017-11-14 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2017-11-14 |
Time |
10:23 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2017-11-14 |
Time |
10:23 |
Sent To |
|
|
Notes |
2017-11-14 10:24:22 | REVIEW BY HMOSER, SIMPLY VERIFIED SECOND COPY WAS | | IDENTICAL. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2017-10-25 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-10-25 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-10-25 |
Time |
14:50 |
Sent To |
|
|
Notes |
2017-10-25 15:09:33 | PLAN DENIED | | ONLY ONE MECHANICAL PLAN SUBMITTED. | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2017-03-17 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-02-23 |
Time |
09:36 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-03-17 |
Time |
14:43 |
Sent To |
|
|
Notes |
2017-03-17 14:48:52 | PLAN DENIED | | 1) REFER TO SECTION M1602.4 BALANCED RETURN AIR | | 2014 FBC (M) | | 2) COMPLETE EQUIPMENT SCHEDULE ON PLAN. | | PER SECTION 107 FBC 2014 | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2016-08-11 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2016-08-11 |
Time |
13:37 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2016-08-11 |
Time |
13:00 |
Sent To |
|
|
Notes |
2016-08-11 13:37:33 | PASS PROVISO | | PROVIDE ENGINEER DETAIL ON CONDENSER TIE DOWN TO SLAB. | | PER SECTION 301.15 WIND RESISTANCE 2014 FBC (M) | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2017-10-04 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-10-04 |
Time |
19:08 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-10-04 |
Time |
19:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2017-02-22 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-02-22 |
Time |
08:42 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-02-22 |
Time |
08:42 |
Sent To |
|
|
Notes |
2017-02-22 08:53:10 | 2ND REVIEW | | | | | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | | | PLUMBING COMMENTS: 2ND REQUEST PREVIOUS COMMENTS NOT | | ADDRESSED. | | | | 1. SHOW LAUNDRY ON RISER DIAGRAM IT SHALL CONNECT TO | | BUILDING DRAIN DOWN STREAM OF BATHROOM GROUP. WPB AMEND | | TO FBC 107.3.5.3(11) / FBC RES P3108.4 | | 2. SHOW LOCATION OF WATER HEATER. PER WPB AMEND TO FBC | | 107.2.1 | | | | NEW COMMENTS; | | | | 1. REVISE DESCRIPTION OF WORK ON THE PLUMBING SUB | | PERMIT APPLICATION TO REFLECT THE COMPLETE SCOPE OF | | WORK SHOWN ON THE PLAN. PER WPB AMEND TO FBC 107.2.1 | | | | 2. PROVIDE DIMENSION OF THE NEW SHOWER SHALL COMPLY | | WITH FBC RES P2708.1 GENERAL. | | SHOWER COMPARTMENTS SHALL HAVE NOT LESS THAN 900 SQUARE | | INCHES (0.6 M2) OF INTERIOR CROSS-SECTIONAL AREA. | | SHOWER COMPARTMENTS SHALL BE NOT LESS THAN 30 INCHES | | (762 MM) IN MINIMUM DIMENSION MEASURED FROM THE | | FINISHED INTERIOR DIMENSION OF THE SHOWER COMPARTMENT, | | EXCLUSIVE OF FIXTURE VALVES, SHOWER HEADS, SOAP DISHES, | | AND SAFETY GRAB BARS OR RAILS. THE MINIMUM REQUIRED | | AREA AND DIMENSION SHALL BE MEASURED FROM THE FINISHED | | INTERIOR DIMENSION AT A HEIGHT EQUAL TO THE TOP OF THE | | THRESHOLD AND AT A POINT TANGENT TO ITS CENTERLINE AND | | SHALL BE CONTINUED TO A HEIGHT OF NOT LESS THAN 70 | | INCHES (1778 MM) ABOVE THE SHOWER DRAIN OUTLET. HINGED | | SHOWER DOORS SHALL OPEN OUTWARD. THE WALL AREA ABOVE | | BUILT-IN TUBS HAVING INSTALLED SHOWER HEADS AND IN | | SHOWER COMPARTMENTS SHALL BE CONSTRUCTED IN ACCORDANCE | | WITH SECTION R702.4. SUCH WALLS SHALL FORM A | | WATER-TIGHT JOINT WITH EACH OTHER AND WITH EITHER THE | | TUB, RECEPTOR OR SHOWER FLOOR. | | | | | | DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND | | THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON | | RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS. | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2016-08-17 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-08-17 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-08-17 |
Time |
11:41 |
Sent To |
|
|
Notes |
2016-08-17 12:52:30 | 1ST REVIEW | | | | | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | 1. SHOW LAUNDRY ON RISER DIAGRAM IT SHALL CONNECT TO | | BUILDING DRAIN DOWN STREAM OF BATHROOM GROUP. WPB AMEND | | TO FBC 107.3.5.3(11) / FBC RES P3108.4 | | 2. SHOW LOCATION OF WATER HEATER. PER WPB AMEND TO FBC | | 107.2.1 | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
N |
Date |
2017-10-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-10-24 |
Time |
11:03 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-10-24 |
Time |
07:04 |
Sent To |
|
|
Notes |
2017-10-24 11:04:21 | SEE PERMIT # 15110883 |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
F |
Date |
2017-02-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-02-23 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-02-23 |
Time |
09:16 |
Sent To |
|
|
Notes |
2017-02-23 09:18:07 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 2ND REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. COMMENTS FROM 1ST REVIEW NOT ADDRESSED. | | 2. ROOFING PERMIT REQUIRED. | | 3. PROVIDE PRODUCT APPROVALS FOR ROOF SYSTEM | | COMPONENTS. | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2016-08-09 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-08-09 |
Time |
14:54 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-08-09 |
Time |
14:54 |
Sent To |
|
|
Notes |
2016-08-09 14:59:01 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER ? PX3169 | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | ACTION: DENIED | | DATE: 8/9/16 | | | | 1. NEW ROOFING TO BE INSTALLED. | | 2. PROVIDE PRODUCT APPROVALS FOR NEW ROOF SYSTEM. | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY | | FAC RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD. SPECIFICALLY, PROVIDE ROOFING | | SUBMITTALS. | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2017-10-02 |
|
|
Cont ID |
|
Sent By |
|
Date |
2017-10-02 |
Time |
|
Rev Time |
0.00 |
Received By |
kmartin |
Date |
2017-10-02 |
Time |
11:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2017-02-10 |
|
|
Cont ID |
|
Sent By |
|
Date |
2017-02-10 |
Time |
|
Rev Time |
0.00 |
Received By |
kmartin |
Date |
2017-02-10 |
Time |
09:28 |
Sent To |
HIST |
|
Notes |
2017-02-10 09:27:50 | PREVIOUS COMMENTS HAVE NOT BEEN ADDRESSED. | | | | FOR MORE INFORMATION PLEASE CONTACT KEVIN MARTIN, URBAN | | DESIGN PLANNER AT (561) 822-1426 OR [email protected]. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2016-08-08 |
|
|
Cont ID |
|
Sent By |
|
Date |
2016-08-08 |
Time |
|
Rev Time |
0.00 |
Received By |
kmartin |
Date |
2016-08-08 |
Time |
11:22 |
Sent To |
|
|
Notes |
2016-08-08 11:23:02 | 1. PROPERTY SURVEY NEEDED TO VERIFY DENSITY | | REQUIREMENT. | | | | FOR MORE INFORMATION PLEASE CONTACT KEVIN MARTIN, URBAN | | DESIGN PLANNER AT (561) 822-1426 OR [email protected]. |
|
|