Plan Review Details - Permit 16070388
Plan Review Stops For Permit 16070388
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-11-02 Cont ID  
Sent By jgomez Date 2016-11-02 Time 14:23 Rev Time 0.00
Received By jgomez Date 2016-11-02 Time 09:29 Sent To P
Notes
2016-11-02 12:50:07CONTRIBUTING HISTORIC HOUSE. ENERGY CALCULATIONS ARE
 NOT REQUIRED. THEY WERE NOT REVISED EITHER. ENERGY
 CALCULATIONS WERE DISCARDED TO AVOID CONFLICTS/DELAYS.
 JG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-08-16 Cont ID  
Sent By jgomez Date 2016-08-16 Time 17:21 Rev Time 0.00
Received By jgomez Date 2016-08-16 Time 09:28 Sent To  
Notes
2016-08-16 16:08:25RESIDENTIAL (R3) ALTERATIONS, BUILDING REVIEW COMMENTS.
 CODE: FBC 5TH EDITION (2014)
  
 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT.
 BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF
 THE UNIFIED LAND DEVELOPMENT CODE. (NOTE: THIS MAY BE
 DONE LATER WHEN PERMIT IS READY TO BE ISSUED).
  
 2- SHEET A-1:
 A) REVISE OCCUPANCY SPECIFIED. THIS IS GROUP R3 NOT R2.
 SEE SEC. 310.5 FBC-BUILDING, 5TH EDITION (2014).
  
 B) REVISE THE LEVEL OF ALTERATION SPECIFIED. ACCORDING
 TO WORK SHOWN ON PLANS AND SPECIFICATIONS THIS IS
 ALTERATION LEVEL 3 NOT LEVEL 2. SEE SEC. 505
 FBC-EXISTING BUILDING, 5TH EDITION (2014). AND, THE
 CONVERSION OF GARAGE TO LIVABLE AREA IS A CHANGE OF
 OCCUPANCY. SEE SEC. 506 AND SEC. 1001.3.1 FBC-EXISTING
 BUILDING, 5TH EDITION (2014).
  
 C) CLARIFY/REVISE DEMOLITION NOTES FOR REMOVAL. THERE
 ARE TWO NOTES #1. AND, ONE OF THEM SAYS " ALL EXTERIOR
 DOORS AND WINDOWS TO REMAIN". FLOOR PLAN ON SAME SHEET
 SPECIFIES EXISTING WINDOWS AND DOORS TO BE REPLACED.
 REVISE AS REQUIRED. SEC. 107.2.1 CITY AMENDMENTS.
  
 3- SHEET A-2:
 A) CLARIFY FOOTING SCHEDULE AND FOOTINGS SHOWN ON THE
 FOUNDATION PLANS. THERE ARE TWO F2 FOOTINGS WITH
 DIFFERENT SPECIFICATIONS. CLEARLY IDENTIFY EACH FOOTING
 SHOWN ON THE FOUNDATION PLANS. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 B) WALL SECTION: SPECIFY THE VAPOR RETARDER AS REQUIRED
 BY SEC. R506.2.3 FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 4- SPECIFY CARBON MONOXIDE ALARMS WITHIN 10 FEET OF
 EACH BEDROOM AS REQUIRED BY SEC. R315 FBC-RESIDENTIAL.
  
 5- ENERGY CALCULATIONS SUBMITTED:
 NOTE: THIS HOUSE IS A CONTRIBUTING HISTORIC HOUSE. IT
 IS EXEMPT FORM THE FBC-ENERGY CONSERVATION CODE.
 (ENERGY CALCULATIONS AND A/C EQUIPMENT SIZING
 CALCULATIONS ARE TWO DIFFERENT THINGS. EQUIPMENT SIZING
 CALCULATIONS ARE REQUIRED). IF CONTRACTOR STILL WANTS
 TO SUBMIT THE ENERGY CALCULATIONS, THEN THE FOLLOWING
 NEEDS TO BE ADDRESSED:
  
 A) COMPLETE ALL THE INFORMATION ON TOP OF FORM,
 INCLUDING OWNER NAME AND BUILDER NAME.
 B) REVISE ITEM #1. THIS IS NOT AN ADDITION. THIS IS AN
 EXISTING BUILDING.
 C) NUMBER OF BEDROOMS IS INCORRECT. CALCULATIONS SEEMS
 TO BE DONE FOR ENTIRE HOUSE.
 D) CONDITIONED FLOOR ARE DOESN'T MATCH AREA SHOWN ON
 PLANS.
 E) WALL TYPES ON ITEM #9 NEED TO INCLUDE THE CONCRETE
 BLOCK WALL SHOWN ON SHEET A-2 BY THE NEW BEDROOM. SEE
 LEGEND FOR WALL TYPE "E1".
 F) PLANS SHOW NEW WATER HEATER, BUT ITEM # 14 STATES
 "NONE REQUIRED". CLARIFY/REVISE.
 G) OWNER/AGENT TO CERTIFY AND DATE BOTTOM OF FORM.
 H) SEC. R806.2 FBC-RESIDENTIAL REQUIRES 1/150 RATIO FOR
 ATTIC VENTILATION. THE ATTIC VENTILATION SHOWN ON PAGE
 2 OF 4 IS 1/300. PROVIDE COMPLETE SPECIFICATIONS AND
 DETAILS SHOWING COMPLIANCE WITH THE EXCEPTION OF SEC.
 R806.2 WHICH ALLOWS 1/300 VENTING.
 I) REVISE DOORS INFORMATION SHOWN ON PAGE 3 OF 4. PLANS
 AND PRODUCT APPROVALS SUBMITTED DON'T SHOW ANY WOOD
 DOOR.
 J) THE WINDOWS OVERHANG DEPTH AND SEPARATION SHOWN ON
 PAGE 3 OF 4 DON'T MATCH PLANS. REVISE AS REQUIRED.
 K) BUILDER TO COMPLETE THE EPL DISPLAY CARD.
 L) PROVIDE THE INSPECTION CHECKLIST.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 ***PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS
 FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-10-18 Cont ID  
Sent By vperez Date 2016-10-18 Time 10:44 Rev Time 0.00
Received By vperez Date 2016-10-18 Time 10:28 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-07-21 Cont ID  
Sent By vperez Date 2016-07-21 Time 17:03 Rev Time 0.00
Received By vperez Date 2016-07-21 Time 17:03 Sent To  
Notes
2016-07-21 17:07:49INITIAL ELECTRICAL PLAN REVIEW
  
 APPLICABLE CODES IN EFFECT:
 FLORIDA RES BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70- 2011 NEC
 COMMENTS:
  
 1. PLEASE ADDRESS HISTORICAL COMMENTS FOR ELECTRICAL
 APPROVAL.
 2. FEEL FREE TO CONTACT ME DIRECTLY SHOULD YOU HAVE ANY
 QUESTIONS OR CONCERNS.
  
  
  
 VALENTINO PEREZ
 ELECTRICAL PLANS EXAMINER II
 561-805-6717
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2016-10-31 Cont ID  
Sent By fmittner Date 2016-10-31 Time 16:33 Rev Time 0.00
Received By fmittner Date 2016-10-31 Time 16:33 Sent To  
Notes
2016-10-31 16:33:20APPROVED PER HPB CASE 16-70 LEVEL 2

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2016-07-20 Cont ID  
Sent By fmittner Date 2016-07-20 Time 14:00 Rev Time 0.00
Received By fmittner Date 2016-07-20 Time 14:00 Sent To  
Notes
2016-07-20 14:02:45PROPERTY LOCATED IN CENTRAL PARK HISTORIC DISTRICT.
 WINDOW REPLACEMENT AND CHANGE IN OPENINGS (IE CARPORT)
 REQUIRES SUBMITTAL OF A COA (CERTIFICATE OF
 APPROPRIATENESS) TO EVALUATE CHANGES PER ORDINANCE.
 QUESTIONS CONTACT FRIEDERIKE MITTNER, CITY HISITORIC
 PRESERVATION PLANNER AT 822-1457.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-11-09 Cont ID  
Sent By lmarchan Date 2016-11-09 Time 08:57 Rev Time 0.00
Received By lmarchan Date 2016-11-07 Time 10:14 Sent To  
Notes
2016-11-08 10:14:24RESUB ROUTED TO JVALIDO

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-11-03 Cont ID  
Sent By tklarge Date 2016-11-03 Time 04:40 Rev Time 0.00
Received By tklarge Date 2016-10-11 Time 08:40 Sent To  
Notes
2016-10-12 08:40:33R19

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-08-31 Cont ID  
Sent By cpuell Date 2016-08-31 Time 09:18 Rev Time 0.00
Received By cpuell Date 2016-07-12 Time 09:04 Sent To  
Notes
2016-11-01 18:53:41ROUTED TO JULIO GOMEZ 11/01/2016 - JORGE V.
2016-07-13 09:04:34R12

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2016-11-02 Cont ID  
Sent By jgomez Date 2016-11-02 Time 14:06 Rev Time 0.00
Received By jgomez Date 2016-11-02 Time 14:05 Sent To  
Notes
2016-11-02 14:08:03NO FEES. MU-2016-024053.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2016-08-16 Cont ID  
Sent By jgomez Date 2016-08-16 Time 17:27 Rev Time 0.00
Received By jgomez Date 2016-08-16 Time 17:27 Sent To  
Notes
2016-08-16 17:27:331- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT.
 BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF
 THE UNIFIED LAND DEVELOPMENT CODE. (NOTE: THIS MAY BE
 DONE LATER WHEN PERMIT IS READY TO BE ISSUED).
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2016-11-08 Cont ID  
Sent By jvalido Date 2016-11-08 Time 14:53 Rev Time 0.00
Received By jvalido Date 2016-11-08 Time 14:20 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2016-11-01 Cont ID  
Sent By jvalido Date 2016-11-01 Time 18:23 Rev Time 0.00
Received By jvalido Date 2016-11-01 Time 16:48 Sent To  
Notes
2016-11-01 18:22:34CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA
 BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION
  
 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS
  
 (1) PROVIDE CFM QUANTITIES FOR THE THREE SUPPLY DUCTS
 TO LIVING ROOM AREA.
 (2) CONFIRM TOTAL SUPPLY CFM FOR AHU. ALL SUPPLY DROP
 CFM TOTALS (AS PER PLANS) EQUAL MORE THAN EQUIPMENT
 SCHEDULE CFM TOTAL OF 1000 CFM.
 (3) PROVIDE PROPER SUPPLY CFM DISTRIBUTION THROUGHOUT
 THE HOUSE.
 (4) FORM R405-2014 HAS TO BE COMPLETLY FILLED OUT AND
 MUST BE SIGNED BY "OWNER/AGENT" (SEE MARKED AREAS ON
 FORMS)
  
 FLORIDA ENERGY CODE FBC 2014
  
 JORGE VALIDO
 WPB MECHANICAL INSPECTOR/PLANS EXAMINER
 [email protected]
 561-805-6716
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-08-30 Cont ID  
Sent By jvalido Date 2016-08-30 Time 18:14 Rev Time 0.00
Received By jvalido Date 2016-08-30 Time 17:16 Sent To  
Notes
2016-08-30 18:13:46CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA
 BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION
  
 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS
  
 (1) IDENTIFY ALL AREAS IN HOME
 (2) PROVIDE ACTUAL TRUNK LINE SIZES.
 (3) SHOW ON PLANS DISTRIBUTION BOXES WITH FLEX DUCT TO
 DIFFERENT AREAS OF HOME. ( A ROUND DUCT CANNOT COME OFF
 OF A ROUND DUCT ).
 (4) PROVIDE ALL EXISTING DUCT CFM QUANTITIES, GRILL AND
 DUCT SIZES.
 (5) PROVIDE RETURN AIR FROM ALL BEDROOMS.
  
 FLORIDA ENERGY CODE FBC 2014
  
 (6) FORM R405-2014 MUST BE SIGNED BY OWNER/AGENT
 (7) PROVIDE AHRI
  
 JORGE VALIDO
 WPB MECHANICAL INSPECTOR/PLANS EXAMINER
 [email protected]
 561-805-6716
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-11-03 Cont ID  
Sent By tklarge Date 2016-11-03 Time 04:36 Rev Time 0.00
Received By tklarge Date 2016-11-03 Time 04:05 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-08-01 Cont ID  
Sent By tklarge Date 2016-08-01 Time 06:22 Rev Time 0.00
Received By tklarge Date 2016-08-01 Time 06:07 Sent To  
Notes
2016-08-01 06:22:111) THE SANITARY RISER IS NOT TO CODE. THE WATER CLOSETS
 ARE NOT VENTED, THE UPSTREAM DRY VENT IS NOT PERMITTED.
 2014 FBCR SEC.P3101.2, P3101.2.1.
 2) A NEW WATER HEATER IS BEING INSTALLED YET THE ENERGY
 CALCULATIONS SHOW "NONE REQUIRED." CLARIFY.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2016-10-31 Cont ID  
Sent By fmittner Date 2016-10-31 Time 16:33 Rev Time 0.00
Received By fmittner Date 2016-10-31 Time 16:33 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2016-07-20 Cont ID  
Sent By fmittner Date 2016-07-20 Time 14:00 Rev Time 0.00
Received By fmittner Date 2016-07-20 Time 14:00 Sent To  
Notes
***NONE***