Plan Review Stops For Permit 16070342 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2017-02-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-02-09 |
Time |
17:16 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-02-09 |
Time |
15:10 |
Sent To |
|
|
Notes |
2017-02-09 15:19:19 | RESIDENTIAL (R3) ALTERATIONS FOURTH BUILDING REVIEW | | CHECKLIST. | | CODE: FBC-5TH EDITION (2014). | | | | 1- A) ENGINEER TO PAY FOUR TIMES THE PLAN REVIEW FEES | | AS REQUIRED BY FLORIDA STATUTE 553.80(2)(B) FOR | | MULTIPLE FAILURES TO PROVIDE A COMPLETE ONE HOUR FIRE | | RATED WALL ASSEMBLY. | | | | ORIGINAL COMMENT: | | B) NEED 1 HOUR FIRE RESISTANCE WALL WITH EXPOSURE ON | | BOTH SIDES OF THE WEST SIDE WALL. REVISE PLANS AS | | REQUIRED. PROVIDE FIRE RATED WALL DETAIL AND | | SPECIFICATIONS. | | RESPONSE: | | REPEAT COMMENT. ENGINEER OF RECORD NEEDS TO PROVIDE A | | COMPLETE WALL ASSEMBLY DETAIL AND SPECIFICATIONS. | | INFORMATION SUBMITTED IS INSUFFICIENT. IT DOESN'T | | SPECIFY A COMPLETE ASSEMBLY ON BOTH SIDES OF THE WALL. | | NEED TO PROVIDE COMPLETE SPECIFICATIONS (TYPE, | | THICKNESS OF MATERIALS, ETC) ON EACH SIDE OF THE WALL. | | NOTE: UL 263 IS AN STANDARD TEST METHOD NOT FIRE RATED | | ASSEMBLY. | | | | 2- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | CONTRACTOR OVERHEAD AND PROFIT AND ALL L DESIGN | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY | | AMENDMENTS. | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL. SINCE | | THERE WAS NO RESPONSE AFTER SEVERAL REQUESTS, THE | | VALUATION WAS ESTIMATED TO BE $30,000 +/-. THE PERMIT | | FEE IS $858.56. | | | | 3- THE ATTACHMENT OF THE BARN DOORS SHOWN NORTH | | ELEVATION IS NOT CLEAR AND NEEDS MORE INFORMATION: A) | | THERE ARE NO SPECIFICATIONS FOR THE NUMBER AND LOCATION | | OF FASTENERS. B) THE SCREW SIZE #8 X 1-5/8" SPECIFIED | | MAY NOT BE ADEQUATE. THE LENGTH OF THIS SCREW MAY JUST | | BE ENOUGH TO FASTEN TO THE STUCCO INSTEAD OF THE | | FRAMING MEMBERS. C) CLEARLY SPECIFY HOW ARE THESE DOORS | | ATTACHED TO THE STRUCTURE FRAMING MEMBERS. D) SPECIFY | | HOW ARE THE BARN DOORS SCREWED TOGETHER. SEC. R301.1 | | FBC-RESIDENTIAL. | | | | 4- SITE PLAN ON SHEET S1 SPECIFIES 3'-0" SETBACK ON THE | | WEST SIDE. THIS IS INCORRECT. SEE SURVEY AND REVISE AS | | REQUIRED. SEC. 107.2.1 CITY AMENDMENTS. | | | | 5- WINDOW SHOWN ON THE EAST ELEVATION IS LOCATED IN THE | | END ZONE, NOT INTERIOR ZONE. IT SHOULD BE NOTED AS "B" | | NOT "A". REVISE AS REQUIRED. SEC. R301.1 | | FBC-RESIDENTIAL. | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION. | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2017-01-24 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-01-24 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-01-24 |
Time |
14:50 |
Sent To |
|
|
Notes |
2017-01-24 15:05:35 | RE-SUBMITTAL FORM STATES "PLANS SUBMITTED FOR | | PRE-APPROVAL". ???? | | | | | | -REVIEW WILL NOT BE DONE FOR PRE-APPROVALS. PROVIDE 2 | | COMPLETE SETS SIGNED AND SEALED BY THE ENGINEER OF | | RECORD FOR COMPLETE PLAN REVIEW AND APPROVAL. | | | | ****NOTE: TALKED TO MAT (FROM BESSENROTH BUILDERS) OVER | | THE PHONE AT (561)281-6229. TOLD HIM I NEED THE TWO | | COMPLETE REVISED SETS SIGNED AND SEALED BY THE ENGINEER | | OF RECORD FOR ME TO DO THE REVIEW. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2016-12-08 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-12-08 |
Time |
18:00 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-12-08 |
Time |
14:48 |
Sent To |
|
|
Notes |
2016-12-08 15:00:57 | RESIDENTIAL (R3) ALTERATIONS THIRD BUILDING REVIEW | | CHECKLIST. | | CODE: FBC-5TH EDITION (2014). | | | | | | NOTE: | | ENGINEER OF RECORD MAY BE CHARGED FOUR TIMES THE PLAN | | REVIEW FEE IF PLANS ARE DENIED THREE OR MORE TIMES AS | | REQUIRED BY FLORIDA STATUTE 553.80(2)(B). | | | | | | 1- SURVEY SUBMITTED SHOWS 2.7' SETBACK FROM THE | | PROPERTY LINE ON THE WEST SIDE. ACCORDING TO TABLE | | R302.1(1) FBC-RESIDENTIAL, 5TH EDITION (2014) NEED THE | | FOLLOWING: | | A) OPENINGS ARE NOT ALLOWED. | | RESPONSE: LAUNDRY WINDOW ON THE WEST WALL WAS REMOVED | | BUT A NEW OPENING WAS CREATED FOR THE NEW A/C. NO | | OPENINGS ARE ALLOWED. NEED TO KEEP ONE HOUR FIRE RATING | | ON THE WALL. A/C UNIT WILL BRAKE THE FIRE RATING OF THE | | ASSEMBLY. REVISE AS REQUIRED. | | | | B) NEED 1 HOUR FIRE RESISTANCE WALL WITH EXPOSURE ON | | BOTH SIDES OF THE WEST SIDE WALL. REVISE PLANS AS | | REQUIRED. PROVIDE FIRE RATED WALL DETAIL AND | | SPECIFICATIONS. | | RESPONSE: REPEAT COMMENT. ENGINEER OF RECORD NEEDS TO | | PROVIDE WALL ASSEMBLY DETAIL AND SPECIFICATIONS. | | INFORMATION WAS NOT PROVIDED. NOTE: NEED TO SPECIFY | | ASSEMBLY TESTED IN ACCORDANCE WITH ASTM E119 OR UL 263 | | WITH EXPOSURE FROM BOTH SIDES. | | | | 2- PROVIDE COMPLETE INFORMATION SHOWING COMPLIANCE WITH | | THE REQUIRED HEATING FOR HABITABLE SPACES. SEC. R303.9 | | FBC-RESIDENTIAL. | | RESPONSE: WALL A/C UNIT WITH HEAT LOCATED ON THE WEST | | WALL IS NOT ALLOWED. SEE ITEM #1(A) ABOVE. REVISE AS | | REQUIRED. | | | | 3- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | CONTRACTOR OVERHEAD AND PROFIT AND ALL DESIGN | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY | | AMENDMENTS. | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL. PROVIDE | | COPY OF SIGNED CONTRACT FOR THE CONSTRUCTION AND COPY | | OF CONTRACT FOR THE DESIGN PROFESSIONAL. | | | | 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.002(33) FOR: | | A) BARN DOORS AS SHOWN ON PLANS. | | RESPONSE: REPEAT COMMENT. REVIEW IS NOT ONLY FOR | | HISTORIC. BUILDING REVIEW IS REQUIRED AS WELL. IF THERE | | IS NOT PRODUCT APPROVAL, THEN PROVIDE COMPLETE SITE | | SPECIFIC ENGINEERING ANALYSIS FOR BUILDING OFFICIAL | | REVIEW AND APPROVAL. | | | | 5- ENGINEER OF RECORD TO REVIEW/APPROVE ABOVE PRODUCT | | APPROVAL AS REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2016-10-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-10-11 |
Time |
10:40 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-10-11 |
Time |
12:13 |
Sent To |
|
|
Notes |
2016-10-05 10:41:17 | | | RESIDENTIAL (R3) ALTERATION SECOND BUILDING REVIEW | | CHECKLIST. | | CODE: FBC 5TH EDITION (2014) | | | | ORIGINAL COMMENT: | | 1- PROVIDE SURVEY SHOWING SETBACKS FROM PROPERTY LINE | | TO VERIFY COMPLIANCE WITH THE FIRE RESISTANCE | | CONSTRUCTION OF SEC. R302.1 FBC-RESIDENTIAL. | | | | RESPONSE: | | SURVEY SUBMITTED SHOWS 2.7' SETBACK FROM THE PROPERTY | | LINE ON THE WEST SIDE. ACCORDING TO TABLE R302.1(1) | | FBC-RESIDENTIAL, 5TH EDITION (2014) NEED THE FOLLOWING: | | A) OPENINGS ARE NOT ALLOWED. REVISE PLANS AS REQUIRED. | | | | B) NEED 1 HOUR FIRE RESISTANCE WALL WITH EXPOSURE ON | | BOTH SIDES OF THE WEST SIDE WALL. REVISE PLANS AS | | REQUIRED. PROVIDE FIRE RATED WALL SPECIFICATIONS. | | | | 2- PROVIDE COMPLETE INFORMATION SHOWING COMPLIANCE WITH | | THE REQUIRED HEATING FOR HABITABLE SPACES. SEC. R303.9 | | FBC-RESIDENTIAL. | | | | RESPONSE: | | COMMENT NOT ADDRESSED AT ALL. | | | | NEW COMMENT BASED ON NEW INFORMATION PROVIDED: | | 3- TYPICAL WALL SECTION A/S2 SHOWS ONLY ONE 2X4 TOP | | PLATE. EXTERIOR DOOR AND WINDOWS FRAMING DETAILS ON | | SAME SHEET SHOW DOUBLE TOP PLATES. REVISE AS REQUIRED | | TO MATCH. TYPICALLY 2 TOP PLATES ARE REQUIRED. ENGINEER | | OF RECORD TO PROVIDE STRUCTURAL ANALYSIS IF ONLY USING | | ONE TOP PLATE FOR BEARING WALLS. SEC. R301.1 | | FBC-RESIDENTIAL. | | | | ORIGINAL COMMENT: | | 4- WINDOW SCHEDULE SPECIFIES IMPACT WINDOWS. PRODUCT | | APPROVALS SUBMITTED ARE FOR NON-IMPACT WINDOWS. REVISE | | AS REQUIRED TO MATCH. SEC. 107.2.1 CITY AMENDMENTS. | | | | RESPONSE: | | NOT ADDRESSED. | | | | ORIGINAL COMMENT: | | 5- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | CONTRACTOR OVERHEAD AND PROFIT AND ALL DESIGN | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY | | AMENDMENTS. REVISE VALUATION AS REQUIRED. | | | | RESPONSE: | | NOT ADDRESSED. PROVIDE COPY OF FULLY SIGNED CONTRACT | | FOR THE CONSTRUCTION AND FOR COPY OF CONTRACT FOR THE | | DESIGN PROFESSIONAL. | | | | 6- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.002(33) FOR: | | ORIGINAL COMMENT: | | A) SINGLE HUNG WINDOWS. DRAWINGS SUBMITTED WITH NOA | | 15-0511.05 ARE INCOMPLETE. PROVIDE COMPLETE DRAWINGS. | | AND, CLEARLY MARK WHICH MODEL IS GOING TO BE INSTALLED | | TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES. | | | | RESPONSE: | | NOT ADDRESSED. PROVIDE UNCUT DRAWINGS AND MARK WHICH | | MODEL IS GOING TO BE USED. | | | | ORIGINAL COMMENT: | | B) FRENCH DOORS. DRAWINGS SUBMITTED WITH NOA 14-0908.06 | | ARE INCOMPLETE. PROVIDE COMPLETE DRAWINGS. | | | | RESPONSE: | | DRAWINGS SUBMITTED WITH NEW NOA 13-0328.11 ARE | | INCOMPLETE ALSO. PROVIDE COMPLETE UNCUT DRAWINGS. | | | | ORIGINAL COMMENT: | | C) BARN DOORS AS SHOWN ON PLANS. | | | | RESPONSE: | | NOT ADDRESSED. | | | | ORIGINAL COMMENT: | | D) HURRICANE SHUTTERS. AND PROVIDE COMPLETE | | INSTALLATION SCHEDULE. SEE CITY SAMPLE OR PROVIDE | | COMPLETE INFORMATION IN ANY OTHER FORMAT. | | | | RESPONSE: | | NOT ADDRESSED. | | | | NEW COMMENT: | | 7- CLARIFY WHY SUBMITTING NOA FOR SLIDING GLASS DOORS. | | PLANS DON'T SHOW ANY. SEC. 107.2.1 CITY AMENDMENTS. | | | | 8- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | REQUIRE3D BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-08-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-08-19 |
Time |
19:24 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-08-19 |
Time |
19:12 |
Sent To |
E |
|
Notes |
2016-08-19 19:29:18 | RESIDENTIAL (R3) ALTERATION BUILDING REVIEW COMMENTS. | | CODE: FBC 5TH EDITION (2014) | | | | 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. | | BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF | | THE UNIFIED LAND DEVELOPMENT CODE. | | | | 2- THIS IS NOT ALTERATION LEVEL 2. THIS IS A CHANGE OF | | OCCUPANCY (CHANGE OF USE FROM GARAGE TO LIVABLE AREA). | | REVISE AS REQUIRED. SEC. 506 FBC-EXISTING BUILDING, 5TH | | EDITION (2014). | | | | 3- PROVIDE COMPLETE DOORS AND WINDOWS FRAMING DETAILS | | AND SPECIFICATIONS. SPECIFY ALL FRAMING MEMBERS AND | | CONNECTORS. SEC. R301.1 FBC-RESIDENTIAL, 5TH EDITION | | (2014). | | | | 4- PROVIDE SURVEY SHOWING SETBACKS FROM PROPERTY LINE | | TO VERIFY COMPLIANCE WITH THE FIRE RESISTANCE | | CONSTRUCTION OF SEC. R302.1 FBC-RESIDENTIAL. | | | | 5- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE | | REPLACEMENT OF 2X4 STUDS AS SPECIFIED ON THE DEMOLITION | | PLAN. SPECIFY ALL CONNECTORS. SEC. R302.1 | | FBC-RESIDENTIAL. | | | | 6-PROVIDE COMPLETE INFORMATION SHOWING COMPLIANCE WITH | | THE REQUIRED HEATING FOR HABITABLE SPACES. SEC. R303.9 | | FBC-RESIDENTIAL. | | | | 7- MISSING SECTION 5/S2 SPECIFIED ON THE FLOOR PLAN. | | SEC. 107.2.1 CITY AMENDMENTS. | | | | 8- LOCATION OF BATHROOM WINDOW SHOWN ON THE EAST | | ELEVATION DOESN'T MATCH FLOOR PLAN. REVISE AS REQUIRED | | TO MATCH. SEC. 107.2.1 CITY AMENDMENTS. | | | | 9- SPECIFY SAFETY GLASS FOR BATHROOM WINDOW AS REQUIRED | | BY SEC. R308.4.2 FBC-RESIDENTIAL. | | | | 10- CLARIFY WHY THERE IS NOT FRAMING FOR THE BATHROOM | | CORNER BY THE LAVATORY. SEC. R301.1 FBC-RESIDENTIAL. | | | | 11- CHANGING THE USE FROM GARAGE TO HABITABLE SPACE. | | THE RISK CATEGORY CHANGED FROM RISK CATEGORY I TO RISK | | CATEGORY II WHERE THERE IS A HIGHER HAZARD FOR HUMAN | | LIFE. PROVIDE COMPLETE DETAILS AND SPECIFICATIONS | | SHOWING HOW THE STRUCTURE IS REINFORCED TO RESIST ALL | | THE WIND LOADS AS REQUIRED BY SEC. R301.1 | | FBC-RESIDENTIAL. SPECIFY ALL CONNECTORS FROM ROOF TO | | WALL AND WALL TO FOUNDATION. | | | | 12- WEST AND SOUTH ELEVATION SPECIFY STUCCO OVER CMU | | BLOCK WALLS. PLANS DON'T SHOW CMU WALLS. REVISE AS | | REQUIRED. SEC. 107.2.1 CITY AMENDMENTS. | | | | 13- WINDOW SCHEDULE SPECIFIES IMPACT WINDOWS. PRODUCT | | APPROVALS SUBMITTED ARE FOR NON-IMPACT WINDOWS. REVISE | | AS REQUIRED TO MATCH. SEC. 107.2.1 CITY AMENDMENTS. | | | | 14- INTERIOR PARTITION DETAIL: CLARIFY FASTENING OF 2 X | | 4 WOOD STUDS TO THE TRUSS. AND, SPECIFY FASTENING OF 2 | | X 4 TO THE BOTTOM PLATE. SEC. R301.1 FBC-RESIDENTIAL. | | | | 15- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | CONTRACTOR OVERHEAD AND PROFIT AND ALL DESIGN | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY | | AMENDMENTS. REVISE VALUATION AS REQUIRED. | | | | 16- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.002(33) FOR: | | A) SINGLE HUNG WINDOWS. DRAWINGS SUBMITTED WITH NOA | | 15-0511.05 ARE INCOMPLETE. PROVIDE COMPLETE DRAWINGS. | | AND, CLEARLY MARK WHICH MODEL IS GOING TO BE INSTALLED | | TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES. | | | | B) FRENCH DOORS. DRAWINGS SUBMITTED WITH NOA 14-0908.06 | | ARE INCOMPLETE. PROVIDE COMPLETE DRAWINGS. | | | | C) BARN DOORS AS SHOWN ON PLANS. | | | | D) ALL SIMPSON OR USP STRUCTURAL CONNECTORS SPECIFIED | | ON DETAILS. PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL | | COVER PAGE AND PAGE SHOWING THE SPECIFIED CONNECTOR OR | | LIST THE FLORIDA PRODUCT APPROVAL NEXT TO EACH | | SPECIFIED CONNECTOR. | | | | E) HURRICANE SHUTTERS. AND PROVIDE COMPLETE | | INSTALLATION SCHEDULE. SEE CITY SAMPLE OR PROVIDE | | COMPLETE INFORMATION IN ANY OTHER FORMAT. | | | | 17- CLARIFY IF SUBMITTING ENERGY CALCULATIONS OR NOT. | | INFORMATION SUBMITTED IS INCOMPLETE. FORM R405-2014 | | INFORMATION SUBMITTED IS MISSING THE REST OF THE | | PACKAGE. THIS IS A CONTRIBUTING HISTORIC BUILDING. IT'S | | EXEMPT FROM THE ENERGY CODE. BUT IF SUBMITTING ENERGY | | CALCULATIONS, THEN PROVIDE COMPLETE INFORMATION. SEC. | | R101.4.2 FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2017-02-10 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2017-02-10 |
Time |
15:35 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2017-02-10 |
Time |
15:35 |
Sent To |
|
|
Notes |
2017-02-10 15:35:51 | 4TH REVIEW | | | | ADDRESS BUILDING REVIEW COMMENTS FOR AN ELECTRICAL | | APPROVAL. | | | | V PEREZ | | *6717 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2016-12-09 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-12-09 |
Time |
13:46 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-12-09 |
Time |
13:46 |
Sent To |
|
|
Notes |
2016-12-09 13:46:59 | ADDRESS BUILDING REVIEW COMMENTS FOR AN ELECTRICAL | | APPROVAL. | | | | V PEREZ | | *6717 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2016-10-26 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-10-26 |
Time |
10:16 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-10-26 |
Time |
08:52 |
Sent To |
I |
|
Notes |
2016-10-26 10:18:28 | 2ND ELECTRICAL REVIEW NOTES | | REVIEWED FOR COMPLIANCE WITH: | | 5TH EDITION FBC 2014 & NFPA 70 2011 (NEC) | | | | JOB ADDRESS: 814 CLAREMORE DR. | | DESCRIPTION: CONVERT EXISTING GARAGE INTO LIVING SPACES | | MASTER PERMIT: 16070342 | | | | BELOW PLEASE FIND A LIST OF REQUIRED CORRECTIONS. | | ADDITIONAL CORRECTIONS MAY BE REQUIRED AFTER REVIEW OF | | SUBMITTED CORRECTIONS. | | | | NOW THAT THE PROPOSED WORK HAS BEEN APPROVED BY ZONING | | WE CAN PRECEDE WITH THE ELECTRICAL REQUIREMENTS FOR A | | SUCCESSFUL ELECTRICAL PLAN REVIEW. | | 1. YOU WERE ASKED TO MARK ON A SITE PLAN THE LOCATION | | OF THE ELECTRICAL SERVICE POLE SERVICE THE PREMISES. | | YOU WERE TO ALSO INDICATE THE LOCATION OF THE | | ELECTRICAL METER/S AND MAIN DISCONNECT/S. FURTHERMORE | | YOU WERE TOLD TO SHOW HOW THE GARAGE IS SERVED | | ELECTRICALLY. | | 2. THE ELECTRICAL FLOOR PLAN IS MISSING THE REQUIRED | | LIGHTING ABOUT THE ELECTRICAL PANEL (NEC 110.26(D)). | | THERE IS A MISSING OUTLET BELOW THE ELECTRICAL PANEL | | (NEC 210.52(A)(2)). YOU SHALL MARK THE LOCATION OF THE | | WATER HEATER AND THE A/C. | | 3. YOU WERE PREVIOUSLY INFORMED THAT WITH THIS | | CONVERSION YOU WILL HAVE TO PROVIDE HEAT TO THESE | | PREMISES. THIS CAN?T BE WITH PORTABLE UNITS. YOU WILL | | HAVE TO INDICATE IF THE PROPOSED A/C UNIT IS REVERSE | | CYCLE AND PLACE IT STRATEGICALLY TO HEAT THE ENTIRE | | AREA OR PROVIDE ADDITIONAL PERMANENT HEATING. THIS | | ADDITIONAL LOAD SHALL BE INCLUDED IN THE RISER DIAGRAM | | AND LOAD CALCS. | | 4. THE ELECTRICAL RISER DIAGRAM AS PRESENTED DOES NOT | | ANSWER THE QUESTION. YOU SHALL PROVIDE A RISER DIAGRAM | | THAT INCLUDES THE MAIN PANEL W/ITS RESPECTIVE LOAD AS | | WELL AS THE SUB PANEL AND ITS LOAD. YOU SHALL INDICATE | | IF THE PANELS ARE MAIN BREAKER TYPE OR MAIN LUG ONLY | | AND THERE IS A SEPARATE MAIN DISCONNECT. | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER | | (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER | | WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | GREATLY APPRECIATED. | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | | | THANK YOU, | | MIKE ALBARRAN | | ELECTRICAL PLANS EXAMINER | | PH: 561-805-6746 | | EMAIL: [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-08-24 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-08-24 |
Time |
18:30 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-08-24 |
Time |
17:41 |
Sent To |
I |
|
Notes |
2016-08-24 18:31:08 | ELECTRICAL REVIEW NOTES | | REVIEWED FOR COMPLIANCE WITH: | | 5TH EDITION FBC 2014 & NFPA 70 2011 (NEC) | | | | PROJECT NAME: GARAGE REMODEL | | JOB ADDRESS: 314 ARDMORE DR. | | DESCRIPTION: INTERIOR RENOVATIONS OF REAR BLDG. | | MASTER PERMIT: 16070342 | | | | BELOW PLEASE FIND A LIST OF REQUIRED CORRECTIONS. | | ADDITIONAL CORRECTIONS MAY BE REQUIRED AFTER REVIEW OF | | SUBMITTED CORRECTIONS. | | | | PER THE NEC AND THE FBC-R YOU SHALL PROVIDE THE | | FOLLOWING FOR A SUCCESSFUL ELECTRICAL PLAN REVIEW: | | | | 1. A SITE PLAN SHOWING THE LOCATION OF THE FPL UTILITY | | POLE SERVING THE PROPERTY; THE ELECTRICAL SERVICE DROP | | TO THE METER. YOU SHALL ALSO INDICATE HOW THE ELECTRIC | | SERVICE GETS TO THE REAR STRUCTURE. | | 2. YOU SHALL SUBMIT AN ELECTRICAL PAGE SHOWING THE | | REQUIRED ELECTRICAL RECEPTACLES AND LIGHTING OUTLETS. | | SHOW ALL EXISTING OUTLETS AS WELL AS THE PROPOSED AND | | ARK THEM ACCORDINGLY. | | 3. YOU SHALL INCLUDE ON THE DRAWINGS AT A MINIMUM A | | BLOCK NOTE ADDRESSING THE GFI, ARC-FAULT, | | TAMPER-RESISTANT OUTLETS AND SMOKE DETECTORS. | | 4. NO THAT THE GARAGE IS BEING CONVERTED INTO HABITABLE | | SPACE, THE FBC-R REQUIRES THAT HEAT BE PROVIDED. | | 5. YOU SHALL INCLUDE AN ELECTRICAL SERVICE RISER | | DIAGRAM TO SHOW THAT THE EXISTING SERVICE IS CAPABLE OF | | ABSORBING THE ADDED LOADS. | | 6. ADDITIONAL COMMENTS MAY ARISE DUE TO DEFICIENT | | SUBMITTAL DOCUMENTS. | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER | | (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER | | WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | GREATLY APPRECIATED. | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | THANK YOU, | | MIKE ALBARRAN | | ELECTRICAL PLANS EXAMINER | | PH: 561-805-6746 | | EMAIL: [email protected] | | | 2016-07-13 17:52:38 | 7/13/16 THE PROPOSED SCOPE OF WORK HAS TO GO BEFORE | | ZONING BEFORE ANY TRADE REVIEW. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2016-12-07 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2016-12-07 |
Time |
11:02 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2016-12-07 |
Time |
11:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2016-10-04 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2016-10-04 |
Time |
10:33 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2016-10-04 |
Time |
10:33 |
Sent To |
|
|
Notes |
2016-10-04 10:33:51 | CARRIAGE STYLE DOORS SHALL BE UTILIZED IN FRONT OF THE | | FRENCH DOORS AS SHOWN ON FLOORPLAN. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2016-07-20 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2016-07-20 |
Time |
13:50 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2016-07-20 |
Time |
13:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2017-02-23 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-02-14 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-02-01 |
Time |
15:32 |
Sent To |
|
|
Notes |
2017-02-09 16:10:24 | R17 | 2017-02-09 15:33:04 | SIGNED AND SEALED PLANS SUBMITTED. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2017-01-24 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-01-24 |
Time |
15:05 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-01-20 |
Time |
15:52 |
Sent To |
|
|
Notes |
2017-01-24 14:50:41 | RE-SUBMITTAL FORM STATES "PLANS SUBMITTED FOR | | PRE-APPROVAL". ???? |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2016-12-10 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-12-10 |
Time |
04:41 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-11-22 |
Time |
08:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-10-26 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-10-26 |
Time |
10:19 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-09-26 |
Time |
13:50 |
Sent To |
|
|
Notes |
2016-10-26 10:21:03 | 10/26/16 UNSUCCESSFULLY COMPLETED THE PLAN REVIEW | | PROCESS. CONTRACTOR NOTIFIED VIA EMAIL. FILE SENT TO | | SMALL DENIED DRAWER B. MA | 2016-09-26 13:50:30 | R18 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-08-24 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-08-24 |
Time |
18:36 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2016-08-24 18:36:14 | 8/24/16 FAILED MULTIPLE TRADE REVIEWS. CONTRACTOR | | NOTIFIED VIA EMAIL. FILE SENT TO SMALL DENIED DRAWER | | "B". MA |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-08-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-08-22 |
Time |
13:44 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-07-11 |
Time |
10:50 |
Sent To |
|
|
Notes |
2016-08-24 18:35:09 | 8/24/16 FAILED MULTIPLE TRADE REVIEWS. CONTRACTOR | | NOTIFIED VIA EMAIL. FILE SENT TO SMALL DENIED DRAWER | | "B". MA | 2016-07-12 10:50:44 | R25 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
4 |
Status |
F |
Date |
2017-02-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-02-10 |
Time |
09:24 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-02-10 |
Time |
09:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
F |
Date |
2016-12-08 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-12-08 |
Time |
18:16 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-12-08 |
Time |
18:16 |
Sent To |
|
|
Notes |
2017-02-09 15:25:06 | 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.) | | FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED | | PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY | | IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT | | CODE. | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2016-10-05 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-10-05 |
Time |
10:41 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-10-05 |
Time |
10:41 |
Sent To |
|
|
Notes |
2016-10-05 10:42:14 | 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.) | | FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED | | PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY | | IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT | | CODE. | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2016-08-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-08-22 |
Time |
13:43 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-08-22 |
Time |
13:43 |
Sent To |
|
|
Notes |
2016-08-22 13:43:44 | 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. | | BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF | | THE UNIFIED LAND DEVELOPMENT CODE. | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2017-02-14 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-02-14 |
Time |
15:53 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-02-14 |
Time |
14:44 |
Sent To |
|
|
Notes |
2017-02-14 15:56:37 | 1ST REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | 1. BRANCH DRAIN FOR WC AND SH IS NOT VENTED. PER FBC | | RES P3101.2.1 | | | | DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND | | THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON | | RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS. | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | 2017-02-09 15:34:09 | REVISED PLANS SUBMITTED. JG. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2016-12-10 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-12-10 |
Time |
04:40 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-12-10 |
Time |
04:23 |
Sent To |
|
|
Notes |
2016-12-08 18:17:55 | NEW DRAWINGS SUBMITTED. JG. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2016-10-22 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-10-22 |
Time |
07:30 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-10-22 |
Time |
07:22 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2016-07-25 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-07-25 |
Time |
04:43 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-07-25 |
Time |
04:34 |
Sent To |
|
|
Notes |
2016-07-25 04:43:53 | 1) SUBMIT A SANITARY AND WATER RISER FOR REVIEW. WPB | | AMEND. TO FBC SEC. 107.3.5.3. | | 2) SHOW THE WIDTH OF THE NEW SHOWER. COMPLY WITH 2014 | | FBCR SEC. P2708.1. | | 3) SHOW THE FIXTURE CLEARANCES ON THE PLAN. COMPLY WITH | | 2014 FBCR SEC. P2701.5. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
N |
Date |
2017-02-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-02-10 |
Time |
09:24 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-02-10 |
Time |
09:24 |
Sent To |
|
|
Notes |
2017-02-10 09:25:25 | NO ROOFING WORK. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2016-12-07 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2016-12-07 |
Time |
11:02 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2016-12-07 |
Time |
11:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2016-10-04 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2016-10-04 |
Time |
10:34 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2016-10-04 |
Time |
10:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2016-07-20 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2016-07-20 |
Time |
13:50 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2016-07-20 |
Time |
13:50 |
Sent To |
|
|
Notes |
|
|