Plan Review Details - Permit 16070342
Plan Review Stops For Permit 16070342
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2017-02-10 Cont ID  
Sent By jgomez Date 2017-02-09 Time 17:16 Rev Time 0.00
Received By jgomez Date 2017-02-09 Time 15:10 Sent To  
Notes
2017-02-09 15:19:19RESIDENTIAL (R3) ALTERATIONS FOURTH BUILDING REVIEW
 CHECKLIST.
 CODE: FBC-5TH EDITION (2014).
  
 1- A) ENGINEER TO PAY FOUR TIMES THE PLAN REVIEW FEES
 AS REQUIRED BY FLORIDA STATUTE 553.80(2)(B) FOR
 MULTIPLE FAILURES TO PROVIDE A COMPLETE ONE HOUR FIRE
 RATED WALL ASSEMBLY.
  
 ORIGINAL COMMENT:
 B) NEED 1 HOUR FIRE RESISTANCE WALL WITH EXPOSURE ON
 BOTH SIDES OF THE WEST SIDE WALL. REVISE PLANS AS
 REQUIRED. PROVIDE FIRE RATED WALL DETAIL AND
 SPECIFICATIONS.
 RESPONSE:
 REPEAT COMMENT. ENGINEER OF RECORD NEEDS TO PROVIDE A
 COMPLETE WALL ASSEMBLY DETAIL AND SPECIFICATIONS.
 INFORMATION SUBMITTED IS INSUFFICIENT. IT DOESN'T
 SPECIFY A COMPLETE ASSEMBLY ON BOTH SIDES OF THE WALL.
 NEED TO PROVIDE COMPLETE SPECIFICATIONS (TYPE,
 THICKNESS OF MATERIALS, ETC) ON EACH SIDE OF THE WALL.
 NOTE: UL 263 IS AN STANDARD TEST METHOD NOT FIRE RATED
 ASSEMBLY.
  
 2- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR OVERHEAD AND PROFIT AND ALL L DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL. SINCE
 THERE WAS NO RESPONSE AFTER SEVERAL REQUESTS, THE
 VALUATION WAS ESTIMATED TO BE $30,000 +/-. THE PERMIT
 FEE IS $858.56.
  
 3- THE ATTACHMENT OF THE BARN DOORS SHOWN NORTH
 ELEVATION IS NOT CLEAR AND NEEDS MORE INFORMATION: A)
 THERE ARE NO SPECIFICATIONS FOR THE NUMBER AND LOCATION
 OF FASTENERS. B) THE SCREW SIZE #8 X 1-5/8" SPECIFIED
 MAY NOT BE ADEQUATE. THE LENGTH OF THIS SCREW MAY JUST
 BE ENOUGH TO FASTEN TO THE STUCCO INSTEAD OF THE
 FRAMING MEMBERS. C) CLEARLY SPECIFY HOW ARE THESE DOORS
 ATTACHED TO THE STRUCTURE FRAMING MEMBERS. D) SPECIFY
 HOW ARE THE BARN DOORS SCREWED TOGETHER. SEC. R301.1
 FBC-RESIDENTIAL.
  
 4- SITE PLAN ON SHEET S1 SPECIFIES 3'-0" SETBACK ON THE
 WEST SIDE. THIS IS INCORRECT. SEE SURVEY AND REVISE AS
 REQUIRED. SEC. 107.2.1 CITY AMENDMENTS.
  
 5- WINDOW SHOWN ON THE EAST ELEVATION IS LOCATED IN THE
 END ZONE, NOT INTERIOR ZONE. IT SHOULD BE NOTED AS "B"
 NOT "A". REVISE AS REQUIRED. SEC. R301.1
 FBC-RESIDENTIAL.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION.
 (561)805-6712
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2017-01-24 Cont ID  
Sent By jgomez Date 2017-01-24 Time 14:50 Rev Time 0.00
Received By jgomez Date 2017-01-24 Time 14:50 Sent To  
Notes
2017-01-24 15:05:35RE-SUBMITTAL FORM STATES "PLANS SUBMITTED FOR
 PRE-APPROVAL". ????
  
  
 -REVIEW WILL NOT BE DONE FOR PRE-APPROVALS. PROVIDE 2
 COMPLETE SETS SIGNED AND SEALED BY THE ENGINEER OF
 RECORD FOR COMPLETE PLAN REVIEW AND APPROVAL.
  
 ****NOTE: TALKED TO MAT (FROM BESSENROTH BUILDERS) OVER
 THE PHONE AT (561)281-6229. TOLD HIM I NEED THE TWO
 COMPLETE REVISED SETS SIGNED AND SEALED BY THE ENGINEER
 OF RECORD FOR ME TO DO THE REVIEW.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2016-12-08 Cont ID  
Sent By jgomez Date 2016-12-08 Time 18:00 Rev Time 0.00
Received By jgomez Date 2016-12-08 Time 14:48 Sent To  
Notes
2016-12-08 15:00:57RESIDENTIAL (R3) ALTERATIONS THIRD BUILDING REVIEW
 CHECKLIST.
 CODE: FBC-5TH EDITION (2014).
  
  
 NOTE:
 ENGINEER OF RECORD MAY BE CHARGED FOUR TIMES THE PLAN
 REVIEW FEE IF PLANS ARE DENIED THREE OR MORE TIMES AS
 REQUIRED BY FLORIDA STATUTE 553.80(2)(B).
  
  
 1- SURVEY SUBMITTED SHOWS 2.7' SETBACK FROM THE
 PROPERTY LINE ON THE WEST SIDE. ACCORDING TO TABLE
 R302.1(1) FBC-RESIDENTIAL, 5TH EDITION (2014) NEED THE
 FOLLOWING:
 A) OPENINGS ARE NOT ALLOWED.
 RESPONSE: LAUNDRY WINDOW ON THE WEST WALL WAS REMOVED
 BUT A NEW OPENING WAS CREATED FOR THE NEW A/C. NO
 OPENINGS ARE ALLOWED. NEED TO KEEP ONE HOUR FIRE RATING
 ON THE WALL. A/C UNIT WILL BRAKE THE FIRE RATING OF THE
 ASSEMBLY. REVISE AS REQUIRED.
  
 B) NEED 1 HOUR FIRE RESISTANCE WALL WITH EXPOSURE ON
 BOTH SIDES OF THE WEST SIDE WALL. REVISE PLANS AS
 REQUIRED. PROVIDE FIRE RATED WALL DETAIL AND
 SPECIFICATIONS.
 RESPONSE: REPEAT COMMENT. ENGINEER OF RECORD NEEDS TO
 PROVIDE WALL ASSEMBLY DETAIL AND SPECIFICATIONS.
 INFORMATION WAS NOT PROVIDED. NOTE: NEED TO SPECIFY
 ASSEMBLY TESTED IN ACCORDANCE WITH ASTM E119 OR UL 263
 WITH EXPOSURE FROM BOTH SIDES.
  
 2- PROVIDE COMPLETE INFORMATION SHOWING COMPLIANCE WITH
 THE REQUIRED HEATING FOR HABITABLE SPACES. SEC. R303.9
 FBC-RESIDENTIAL.
 RESPONSE: WALL A/C UNIT WITH HEAT LOCATED ON THE WEST
 WALL IS NOT ALLOWED. SEE ITEM #1(A) ABOVE. REVISE AS
 REQUIRED.
  
 3- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR OVERHEAD AND PROFIT AND ALL DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL. PROVIDE
 COPY OF SIGNED CONTRACT FOR THE CONSTRUCTION AND COPY
 OF CONTRACT FOR THE DESIGN PROFESSIONAL.
  
 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 A) BARN DOORS AS SHOWN ON PLANS.
 RESPONSE: REPEAT COMMENT. REVIEW IS NOT ONLY FOR
 HISTORIC. BUILDING REVIEW IS REQUIRED AS WELL. IF THERE
 IS NOT PRODUCT APPROVAL, THEN PROVIDE COMPLETE SITE
 SPECIFIC ENGINEERING ANALYSIS FOR BUILDING OFFICIAL
 REVIEW AND APPROVAL.
  
 5- ENGINEER OF RECORD TO REVIEW/APPROVE ABOVE PRODUCT
 APPROVAL AS REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-10-11 Cont ID  
Sent By jgomez Date 2016-10-11 Time 10:40 Rev Time 0.00
Received By jgomez Date 2016-10-11 Time 12:13 Sent To  
Notes
2016-10-05 10:41:17 
 RESIDENTIAL (R3) ALTERATION SECOND BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014)
  
 ORIGINAL COMMENT:
 1- PROVIDE SURVEY SHOWING SETBACKS FROM PROPERTY LINE
 TO VERIFY COMPLIANCE WITH THE FIRE RESISTANCE
 CONSTRUCTION OF SEC. R302.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 SURVEY SUBMITTED SHOWS 2.7' SETBACK FROM THE PROPERTY
 LINE ON THE WEST SIDE. ACCORDING TO TABLE R302.1(1)
 FBC-RESIDENTIAL, 5TH EDITION (2014) NEED THE FOLLOWING:
 A) OPENINGS ARE NOT ALLOWED. REVISE PLANS AS REQUIRED.
  
 B) NEED 1 HOUR FIRE RESISTANCE WALL WITH EXPOSURE ON
 BOTH SIDES OF THE WEST SIDE WALL. REVISE PLANS AS
 REQUIRED. PROVIDE FIRE RATED WALL SPECIFICATIONS.
  
 2- PROVIDE COMPLETE INFORMATION SHOWING COMPLIANCE WITH
 THE REQUIRED HEATING FOR HABITABLE SPACES. SEC. R303.9
 FBC-RESIDENTIAL.
  
 RESPONSE:
 COMMENT NOT ADDRESSED AT ALL.
  
 NEW COMMENT BASED ON NEW INFORMATION PROVIDED:
 3- TYPICAL WALL SECTION A/S2 SHOWS ONLY ONE 2X4 TOP
 PLATE. EXTERIOR DOOR AND WINDOWS FRAMING DETAILS ON
 SAME SHEET SHOW DOUBLE TOP PLATES. REVISE AS REQUIRED
 TO MATCH. TYPICALLY 2 TOP PLATES ARE REQUIRED. ENGINEER
 OF RECORD TO PROVIDE STRUCTURAL ANALYSIS IF ONLY USING
 ONE TOP PLATE FOR BEARING WALLS. SEC. R301.1
 FBC-RESIDENTIAL.
  
 ORIGINAL COMMENT:
 4- WINDOW SCHEDULE SPECIFIES IMPACT WINDOWS. PRODUCT
 APPROVALS SUBMITTED ARE FOR NON-IMPACT WINDOWS. REVISE
 AS REQUIRED TO MATCH. SEC. 107.2.1 CITY AMENDMENTS.
  
 RESPONSE:
 NOT ADDRESSED.
  
 ORIGINAL COMMENT:
 5- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR OVERHEAD AND PROFIT AND ALL DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS. REVISE VALUATION AS REQUIRED.
  
 RESPONSE:
 NOT ADDRESSED. PROVIDE COPY OF FULLY SIGNED CONTRACT
 FOR THE CONSTRUCTION AND FOR COPY OF CONTRACT FOR THE
 DESIGN PROFESSIONAL.
  
 6- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 ORIGINAL COMMENT:
 A) SINGLE HUNG WINDOWS. DRAWINGS SUBMITTED WITH NOA
 15-0511.05 ARE INCOMPLETE. PROVIDE COMPLETE DRAWINGS.
 AND, CLEARLY MARK WHICH MODEL IS GOING TO BE INSTALLED
 TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES.
  
 RESPONSE:
 NOT ADDRESSED. PROVIDE UNCUT DRAWINGS AND MARK WHICH
 MODEL IS GOING TO BE USED.
  
 ORIGINAL COMMENT:
 B) FRENCH DOORS. DRAWINGS SUBMITTED WITH NOA 14-0908.06
 ARE INCOMPLETE. PROVIDE COMPLETE DRAWINGS.
  
 RESPONSE:
 DRAWINGS SUBMITTED WITH NEW NOA 13-0328.11 ARE
 INCOMPLETE ALSO. PROVIDE COMPLETE UNCUT DRAWINGS.
  
 ORIGINAL COMMENT:
 C) BARN DOORS AS SHOWN ON PLANS.
  
 RESPONSE:
 NOT ADDRESSED.
  
 ORIGINAL COMMENT:
 D) HURRICANE SHUTTERS. AND PROVIDE COMPLETE
 INSTALLATION SCHEDULE. SEE CITY SAMPLE OR PROVIDE
 COMPLETE INFORMATION IN ANY OTHER FORMAT.
  
 RESPONSE:
 NOT ADDRESSED.
  
 NEW COMMENT:
 7- CLARIFY WHY SUBMITTING NOA FOR SLIDING GLASS DOORS.
 PLANS DON'T SHOW ANY. SEC. 107.2.1 CITY AMENDMENTS.
  
 8- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRE3D BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-08-22 Cont ID  
Sent By jgomez Date 2016-08-19 Time 19:24 Rev Time 0.00
Received By jgomez Date 2016-08-19 Time 19:12 Sent To E
Notes
2016-08-19 19:29:18RESIDENTIAL (R3) ALTERATION BUILDING REVIEW COMMENTS.
 CODE: FBC 5TH EDITION (2014)
  
 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT.
 BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF
 THE UNIFIED LAND DEVELOPMENT CODE.
  
 2- THIS IS NOT ALTERATION LEVEL 2. THIS IS A CHANGE OF
 OCCUPANCY (CHANGE OF USE FROM GARAGE TO LIVABLE AREA).
 REVISE AS REQUIRED. SEC. 506 FBC-EXISTING BUILDING, 5TH
 EDITION (2014).
  
 3- PROVIDE COMPLETE DOORS AND WINDOWS FRAMING DETAILS
 AND SPECIFICATIONS. SPECIFY ALL FRAMING MEMBERS AND
 CONNECTORS. SEC. R301.1 FBC-RESIDENTIAL, 5TH EDITION
 (2014).
  
 4- PROVIDE SURVEY SHOWING SETBACKS FROM PROPERTY LINE
 TO VERIFY COMPLIANCE WITH THE FIRE RESISTANCE
 CONSTRUCTION OF SEC. R302.1 FBC-RESIDENTIAL.
  
 5- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 REPLACEMENT OF 2X4 STUDS AS SPECIFIED ON THE DEMOLITION
 PLAN. SPECIFY ALL CONNECTORS. SEC. R302.1
 FBC-RESIDENTIAL.
  
 6-PROVIDE COMPLETE INFORMATION SHOWING COMPLIANCE WITH
 THE REQUIRED HEATING FOR HABITABLE SPACES. SEC. R303.9
 FBC-RESIDENTIAL.
  
 7- MISSING SECTION 5/S2 SPECIFIED ON THE FLOOR PLAN.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 8- LOCATION OF BATHROOM WINDOW SHOWN ON THE EAST
 ELEVATION DOESN'T MATCH FLOOR PLAN. REVISE AS REQUIRED
 TO MATCH. SEC. 107.2.1 CITY AMENDMENTS.
  
 9- SPECIFY SAFETY GLASS FOR BATHROOM WINDOW AS REQUIRED
 BY SEC. R308.4.2 FBC-RESIDENTIAL.
  
 10- CLARIFY WHY THERE IS NOT FRAMING FOR THE BATHROOM
 CORNER BY THE LAVATORY. SEC. R301.1 FBC-RESIDENTIAL.
  
 11- CHANGING THE USE FROM GARAGE TO HABITABLE SPACE.
 THE RISK CATEGORY CHANGED FROM RISK CATEGORY I TO RISK
 CATEGORY II WHERE THERE IS A HIGHER HAZARD FOR HUMAN
 LIFE. PROVIDE COMPLETE DETAILS AND SPECIFICATIONS
 SHOWING HOW THE STRUCTURE IS REINFORCED TO RESIST ALL
 THE WIND LOADS AS REQUIRED BY SEC. R301.1
 FBC-RESIDENTIAL. SPECIFY ALL CONNECTORS FROM ROOF TO
 WALL AND WALL TO FOUNDATION.
  
 12- WEST AND SOUTH ELEVATION SPECIFY STUCCO OVER CMU
 BLOCK WALLS. PLANS DON'T SHOW CMU WALLS. REVISE AS
 REQUIRED. SEC. 107.2.1 CITY AMENDMENTS.
  
 13- WINDOW SCHEDULE SPECIFIES IMPACT WINDOWS. PRODUCT
 APPROVALS SUBMITTED ARE FOR NON-IMPACT WINDOWS. REVISE
 AS REQUIRED TO MATCH. SEC. 107.2.1 CITY AMENDMENTS.
  
 14- INTERIOR PARTITION DETAIL: CLARIFY FASTENING OF 2 X
 4 WOOD STUDS TO THE TRUSS. AND, SPECIFY FASTENING OF 2
 X 4 TO THE BOTTOM PLATE. SEC. R301.1 FBC-RESIDENTIAL.
  
 15- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR OVERHEAD AND PROFIT AND ALL DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS. REVISE VALUATION AS REQUIRED.
  
 16- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 A) SINGLE HUNG WINDOWS. DRAWINGS SUBMITTED WITH NOA
 15-0511.05 ARE INCOMPLETE. PROVIDE COMPLETE DRAWINGS.
 AND, CLEARLY MARK WHICH MODEL IS GOING TO BE INSTALLED
 TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES.
  
 B) FRENCH DOORS. DRAWINGS SUBMITTED WITH NOA 14-0908.06
 ARE INCOMPLETE. PROVIDE COMPLETE DRAWINGS.
  
 C) BARN DOORS AS SHOWN ON PLANS.
  
 D) ALL SIMPSON OR USP STRUCTURAL CONNECTORS SPECIFIED
 ON DETAILS. PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL
 COVER PAGE AND PAGE SHOWING THE SPECIFIED CONNECTOR OR
 LIST THE FLORIDA PRODUCT APPROVAL NEXT TO EACH
 SPECIFIED CONNECTOR.
  
 E) HURRICANE SHUTTERS. AND PROVIDE COMPLETE
 INSTALLATION SCHEDULE. SEE CITY SAMPLE OR PROVIDE
 COMPLETE INFORMATION IN ANY OTHER FORMAT.
  
 17- CLARIFY IF SUBMITTING ENERGY CALCULATIONS OR NOT.
 INFORMATION SUBMITTED IS INCOMPLETE. FORM R405-2014
 INFORMATION SUBMITTED IS MISSING THE REST OF THE
 PACKAGE. THIS IS A CONTRIBUTING HISTORIC BUILDING. IT'S
 EXEMPT FROM THE ENERGY CODE. BUT IF SUBMITTING ENERGY
 CALCULATIONS, THEN PROVIDE COMPLETE INFORMATION. SEC.
 R101.4.2 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2017-02-10 Cont ID  
Sent By vperez Date 2017-02-10 Time 15:35 Rev Time 0.00
Received By vperez Date 2017-02-10 Time 15:35 Sent To  
Notes
2017-02-10 15:35:514TH REVIEW
  
 ADDRESS BUILDING REVIEW COMMENTS FOR AN ELECTRICAL
 APPROVAL.
  
 V PEREZ
 *6717

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2016-12-09 Cont ID  
Sent By vperez Date 2016-12-09 Time 13:46 Rev Time 0.00
Received By vperez Date 2016-12-09 Time 13:46 Sent To  
Notes
2016-12-09 13:46:59ADDRESS BUILDING REVIEW COMMENTS FOR AN ELECTRICAL
 APPROVAL.
  
 V PEREZ
 *6717

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2016-10-26 Cont ID  
Sent By albarran Date 2016-10-26 Time 10:16 Rev Time 0.00
Received By albarran Date 2016-10-26 Time 08:52 Sent To I
Notes
2016-10-26 10:18:282ND ELECTRICAL REVIEW NOTES
 REVIEWED FOR COMPLIANCE WITH:
 5TH EDITION FBC 2014 & NFPA 70 2011 (NEC)
  
 JOB ADDRESS: 814 CLAREMORE DR.
 DESCRIPTION: CONVERT EXISTING GARAGE INTO LIVING SPACES
 MASTER PERMIT: 16070342
  
 BELOW PLEASE FIND A LIST OF REQUIRED CORRECTIONS.
 ADDITIONAL CORRECTIONS MAY BE REQUIRED AFTER REVIEW OF
 SUBMITTED CORRECTIONS.
  
 NOW THAT THE PROPOSED WORK HAS BEEN APPROVED BY ZONING
 WE CAN PRECEDE WITH THE ELECTRICAL REQUIREMENTS FOR A
 SUCCESSFUL ELECTRICAL PLAN REVIEW.
 1. YOU WERE ASKED TO MARK ON A SITE PLAN THE LOCATION
 OF THE ELECTRICAL SERVICE POLE SERVICE THE PREMISES.
 YOU WERE TO ALSO INDICATE THE LOCATION OF THE
 ELECTRICAL METER/S AND MAIN DISCONNECT/S. FURTHERMORE
 YOU WERE TOLD TO SHOW HOW THE GARAGE IS SERVED
 ELECTRICALLY.
 2. THE ELECTRICAL FLOOR PLAN IS MISSING THE REQUIRED
 LIGHTING ABOUT THE ELECTRICAL PANEL (NEC 110.26(D)).
 THERE IS A MISSING OUTLET BELOW THE ELECTRICAL PANEL
 (NEC 210.52(A)(2)). YOU SHALL MARK THE LOCATION OF THE
 WATER HEATER AND THE A/C.
 3. YOU WERE PREVIOUSLY INFORMED THAT WITH THIS
 CONVERSION YOU WILL HAVE TO PROVIDE HEAT TO THESE
 PREMISES. THIS CAN?T BE WITH PORTABLE UNITS. YOU WILL
 HAVE TO INDICATE IF THE PROPOSED A/C UNIT IS REVERSE
 CYCLE AND PLACE IT STRATEGICALLY TO HEAT THE ENTIRE
 AREA OR PROVIDE ADDITIONAL PERMANENT HEATING. THIS
 ADDITIONAL LOAD SHALL BE INCLUDED IN THE RISER DIAGRAM
 AND LOAD CALCS.
 4. THE ELECTRICAL RISER DIAGRAM AS PRESENTED DOES NOT
 ANSWER THE QUESTION. YOU SHALL PROVIDE A RISER DIAGRAM
 THAT INCLUDES THE MAIN PANEL W/ITS RESPECTIVE LOAD AS
 WELL AS THE SUB PANEL AND ITS LOAD. YOU SHALL INDICATE
 IF THE PANELS ARE MAIN BREAKER TYPE OR MAIN LUG ONLY
 AND THERE IS A SEPARATE MAIN DISCONNECT.
  
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER
 (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER
 WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD
 CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID
 AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR
 COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE
 GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 THANK YOU,
 MIKE ALBARRAN
 ELECTRICAL PLANS EXAMINER
 PH: 561-805-6746
 EMAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-08-24 Cont ID  
Sent By albarran Date 2016-08-24 Time 18:30 Rev Time 0.00
Received By albarran Date 2016-08-24 Time 17:41 Sent To I
Notes
2016-08-24 18:31:08ELECTRICAL REVIEW NOTES
 REVIEWED FOR COMPLIANCE WITH:
 5TH EDITION FBC 2014 & NFPA 70 2011 (NEC)
  
 PROJECT NAME: GARAGE REMODEL
 JOB ADDRESS: 314 ARDMORE DR.
 DESCRIPTION: INTERIOR RENOVATIONS OF REAR BLDG.
 MASTER PERMIT: 16070342
  
 BELOW PLEASE FIND A LIST OF REQUIRED CORRECTIONS.
 ADDITIONAL CORRECTIONS MAY BE REQUIRED AFTER REVIEW OF
 SUBMITTED CORRECTIONS.
  
 PER THE NEC AND THE FBC-R YOU SHALL PROVIDE THE
 FOLLOWING FOR A SUCCESSFUL ELECTRICAL PLAN REVIEW:
  
 1. A SITE PLAN SHOWING THE LOCATION OF THE FPL UTILITY
 POLE SERVING THE PROPERTY; THE ELECTRICAL SERVICE DROP
 TO THE METER. YOU SHALL ALSO INDICATE HOW THE ELECTRIC
 SERVICE GETS TO THE REAR STRUCTURE.
 2. YOU SHALL SUBMIT AN ELECTRICAL PAGE SHOWING THE
 REQUIRED ELECTRICAL RECEPTACLES AND LIGHTING OUTLETS.
 SHOW ALL EXISTING OUTLETS AS WELL AS THE PROPOSED AND
 ARK THEM ACCORDINGLY.
 3. YOU SHALL INCLUDE ON THE DRAWINGS AT A MINIMUM A
 BLOCK NOTE ADDRESSING THE GFI, ARC-FAULT,
 TAMPER-RESISTANT OUTLETS AND SMOKE DETECTORS.
 4. NO THAT THE GARAGE IS BEING CONVERTED INTO HABITABLE
 SPACE, THE FBC-R REQUIRES THAT HEAT BE PROVIDED.
 5. YOU SHALL INCLUDE AN ELECTRICAL SERVICE RISER
 DIAGRAM TO SHOW THAT THE EXISTING SERVICE IS CAPABLE OF
 ABSORBING THE ADDED LOADS.
 6. ADDITIONAL COMMENTS MAY ARISE DUE TO DEFICIENT
 SUBMITTAL DOCUMENTS.
  
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER
 (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER
 WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD
 CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID
 AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR
 COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE
 GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
 THANK YOU,
 MIKE ALBARRAN
 ELECTRICAL PLANS EXAMINER
 PH: 561-805-6746
 EMAIL: [email protected]
  
2016-07-13 17:52:387/13/16 THE PROPOSED SCOPE OF WORK HAS TO GO BEFORE
 ZONING BEFORE ANY TRADE REVIEW.

Review Stop HIST HISTORICAL
Rev No 3 Status P Date 2016-12-07 Cont ID  
Sent By fmittner Date 2016-12-07 Time 11:02 Rev Time 0.00
Received By fmittner Date 2016-12-07 Time 11:02 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2016-10-04 Cont ID  
Sent By fmittner Date 2016-10-04 Time 10:33 Rev Time 0.00
Received By fmittner Date 2016-10-04 Time 10:33 Sent To  
Notes
2016-10-04 10:33:51CARRIAGE STYLE DOORS SHALL BE UTILIZED IN FRONT OF THE
 FRENCH DOORS AS SHOWN ON FLOORPLAN.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2016-07-20 Cont ID  
Sent By fmittner Date 2016-07-20 Time 13:50 Rev Time 0.00
Received By fmittner Date 2016-07-20 Time 13:49 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2017-02-23 Cont ID  
Sent By jgomez Date 2017-02-14 Time 11:00 Rev Time 0.00
Received By jgomez Date 2017-02-01 Time 15:32 Sent To  
Notes
2017-02-09 16:10:24R17
2017-02-09 15:33:04SIGNED AND SEALED PLANS SUBMITTED. JG.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2017-01-24 Cont ID  
Sent By jgomez Date 2017-01-24 Time 15:05 Rev Time 0.00
Received By jgomez Date 2017-01-20 Time 15:52 Sent To  
Notes
2017-01-24 14:50:41RE-SUBMITTAL FORM STATES "PLANS SUBMITTED FOR
 PRE-APPROVAL". ????

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2016-12-10 Cont ID  
Sent By tklarge Date 2016-12-10 Time 04:41 Rev Time 0.00
Received By tklarge Date 2016-11-22 Time 08:59 Sent To  
Notes
2016-11-23 08:59:58R04

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-10-26 Cont ID  
Sent By albarran Date 2016-10-26 Time 10:19 Rev Time 0.00
Received By albarran Date 2016-09-26 Time 13:50 Sent To  
Notes
2016-10-26 10:21:0310/26/16 UNSUCCESSFULLY COMPLETED THE PLAN REVIEW
 PROCESS. CONTRACTOR NOTIFIED VIA EMAIL. FILE SENT TO
 SMALL DENIED DRAWER B. MA
2016-09-26 13:50:30R18

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-08-24 Cont ID  
Sent By albarran Date 2016-08-24 Time 18:36 Rev Time 0.00
Received By albarran Date   Time   Sent To  
Notes
2016-08-24 18:36:148/24/16 FAILED MULTIPLE TRADE REVIEWS. CONTRACTOR
 NOTIFIED VIA EMAIL. FILE SENT TO SMALL DENIED DRAWER
 "B". MA

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-08-22 Cont ID  
Sent By jgomez Date 2016-08-22 Time 13:44 Rev Time 0.00
Received By albarran Date 2016-07-11 Time 10:50 Sent To  
Notes
2016-08-24 18:35:098/24/16 FAILED MULTIPLE TRADE REVIEWS. CONTRACTOR
 NOTIFIED VIA EMAIL. FILE SENT TO SMALL DENIED DRAWER
 "B". MA
2016-07-12 10:50:44R25

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status F Date 2017-02-10 Cont ID  
Sent By jgomez Date 2017-02-10 Time 09:24 Rev Time 0.00
Received By jgomez Date 2017-02-10 Time 09:24 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2016-12-08 Cont ID  
Sent By jgomez Date 2016-12-08 Time 18:16 Rev Time 0.00
Received By jgomez Date 2016-12-08 Time 18:16 Sent To  
Notes
2017-02-09 15:25:061- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.)
 FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED
 PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2016-10-05 Cont ID  
Sent By jgomez Date 2016-10-05 Time 10:41 Rev Time 0.00
Received By jgomez Date 2016-10-05 Time 10:41 Sent To  
Notes
2016-10-05 10:42:141- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.)
 FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED
 PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2016-08-22 Cont ID  
Sent By jgomez Date 2016-08-22 Time 13:43 Rev Time 0.00
Received By jgomez Date 2016-08-22 Time 13:43 Sent To  
Notes
2016-08-22 13:43:441- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT.
 BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF
 THE UNIFIED LAND DEVELOPMENT CODE.
  

Review Stop P PLUMBING
Rev No 4 Status F Date 2017-02-14 Cont ID  
Sent By gjohnson Date 2017-02-14 Time 15:53 Rev Time 0.00
Received By gjohnson Date 2017-02-14 Time 14:44 Sent To  
Notes
2017-02-14 15:56:371ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. BRANCH DRAIN FOR WC AND SH IS NOT VENTED. PER FBC
 RES P3101.2.1
  
 DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND
 THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON
 RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS.
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  
2017-02-09 15:34:09REVISED PLANS SUBMITTED. JG.

Review Stop P PLUMBING
Rev No 3 Status P Date 2016-12-10 Cont ID  
Sent By tklarge Date 2016-12-10 Time 04:40 Rev Time 0.00
Received By tklarge Date 2016-12-10 Time 04:23 Sent To  
Notes
2016-12-08 18:17:55NEW DRAWINGS SUBMITTED. JG.

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-10-22 Cont ID  
Sent By tklarge Date 2016-10-22 Time 07:30 Rev Time 0.00
Received By tklarge Date 2016-10-22 Time 07:22 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-07-25 Cont ID  
Sent By tklarge Date 2016-07-25 Time 04:43 Rev Time 0.00
Received By tklarge Date 2016-07-25 Time 04:34 Sent To  
Notes
2016-07-25 04:43:531) SUBMIT A SANITARY AND WATER RISER FOR REVIEW. WPB
 AMEND. TO FBC SEC. 107.3.5.3.
 2) SHOW THE WIDTH OF THE NEW SHOWER. COMPLY WITH 2014
 FBCR SEC. P2708.1.
 3) SHOW THE FIXTURE CLEARANCES ON THE PLAN. COMPLY WITH
 2014 FBCR SEC. P2701.5.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2017-02-10 Cont ID  
Sent By jgomez Date 2017-02-10 Time 09:24 Rev Time 0.00
Received By jgomez Date 2017-02-10 Time 09:24 Sent To  
Notes
2017-02-10 09:25:25NO ROOFING WORK.

Review Stop Z ZONING
Rev No 3 Status P Date 2016-12-07 Cont ID  
Sent By fmittner Date 2016-12-07 Time 11:02 Rev Time 0.00
Received By fmittner Date 2016-12-07 Time 11:02 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2016-10-04 Cont ID  
Sent By fmittner Date 2016-10-04 Time 10:34 Rev Time 0.00
Received By fmittner Date 2016-10-04 Time 10:34 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2016-07-20 Cont ID  
Sent By fmittner Date 2016-07-20 Time 13:50 Rev Time 0.00
Received By fmittner Date 2016-07-20 Time 13:50 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved