Plan Review Details - Permit 16070010
Plan Review Stops For Permit 16070010 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
N |
Date |
2016-07-05 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-07-05 |
Time |
18:28 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-07-05 |
Time |
18:12 |
Sent To |
|
|
Notes |
2016-07-05 18:39:14 | RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS. | | CODE: FBC, 5TH EDITION (2014). | | | | 1- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS (2 | | COPIES) FOR THE ROOF REPAIRS AND GENERAL REPAIRS | | SPECIFIED ON THE PERMIT APPLICATION. SEC. 107.2.1 CITY | | AMENDMENTS. | | | | 2- SPECIFY ROOF PITCH AS REQUIRED BY CITY POLICY FOR | | RE-ROOFING PERMITS. | | | | 3- FLAT ROOF NOA 14-0529.02 SUBMITTED: | | A) CLEARLY IDENTIFY WHICH APPROVED ASSEMBLY IS GOING TO | | BE INSTALLED TO VERIFY COMPLIANCE WITH THE DESIGN | | PRESSURES OF SEC. R301 FBC-RESIDENTIAL, 5TH EDITION | | (2014). | | | | B) IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | PRESSURES OF SEC. R301, THEN SIGNED AND SEALED RAS 117 | | CALCULATIONS ARE REQUIRED BY GENERAL LIMITATION #7 ON | | LAST PAGE ON NOA SUBMITTED. | | NOTE: ASSEMBLIES WITH GENERAL LIMITATION #9 CAN NOT BE | | USED IF THE DESIGN PRESSURES SHOWN ON THE ASSEMBLY | | DON'T MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-07-05 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-07-05 |
Time |
18:40 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-07-01 |
Time |
09:21 |
Sent To |
|
|
Notes |
2016-07-05 09:22:03 | JGOMEZ'S DESK |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2016-07-07 |
|
|
Cont ID |
|
Sent By |
spalmer |
Date |
2016-07-07 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
spalmer |
Date |
2016-07-07 |
Time |
14:26 |
Sent To |
|
|
Notes |
2016-07-07 14:27:14 | THIS PERMIT WAS ORIGINALLY PROCESSED AND CUSTOMER DID | | NOT NEED IT. SO IT WAS USED FOR ANOTHER CONTRACTOR |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
N |
Date |
2016-07-05 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-07-05 |
Time |
18:39 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-07-05 |
Time |
18:13 |
Sent To |
|
|
Notes |
2016-07-05 18:40:23 | RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS. | | CODE: FBC, 5TH EDITION (2014). | | | | 1- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS (2 | | COPIES) FOR THE ROOF REPAIRS AND GENERAL REPAIRS | | SPECIFIED ON THE PERMIT APPLICATION. SEC. 107.2.1 CITY | | AMENDMENTS. | | | | 2- FLAT ROOF NOA 14-0529.02 SUBMITTED: | | A) CLEARLY IDENTIFY WHICH APPROVED ASSEMBLY IS GOING TO | | BE INSTALLED TO VERIFY COMPLIANCE WITH THE DESIGN | | PRESSURES OF SEC. R301 FBC-RESIDENTIAL, 5TH EDITION | | (2014). | | | | B) IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | PRESSURES OF SEC. R301, THEN SIGNED AND SEALED RAS 117 | | CALCULATIONS ARE REQUIRED BY GENERAL LIMITATION #7 ON | | LAST PAGE ON NOA SUBMITTED. | | NOTE: ASSEMBLIES WITH GENERAL LIMITATION #9 CAN NOT BE | | USED IF THE DESIGN PRESSURES SHOWN ON THE ASSEMBLY | | DON'T MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES. | | | | | | NOA APPROVED: | | SHINGLES NOA 14-1022.20 |
|
|
|