Plan Review Stops For Permit 16061439 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2017-01-11 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-01-11 |
Time |
13:50 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-01-11 |
Time |
08:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2016-11-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-11-05 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-11-05 |
Time |
09:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-08-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-08-05 |
Time |
16:44 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-08-05 |
Time |
13:25 |
Sent To |
|
|
Notes |
2016-08-05 16:30:41 | BUILDING PLAN REVIEW | | W. P. B. REVISION: 16061312 | | W. P. B. PERMIT: 15031312 | | ADD: 333 FERN ST. | | CONT: KAST CONSTRUCTION | | CONTACT : | | TEL: (561)689-2910 | | E-MAIL: [email protected] | | | | 1) SHEET 046-A2-5-3 IN STAIRWELL # 4 A 2 HOUR VERTICAL | | EXIT ENCLOSURE. THE 5TH FLOOR REFLECTIVE CEILING PLAN | | INDICATES A DROPPED PORTION OF THE STAIRWELL CEILING | | WITH A 2 HOUR FIRE RATED ENCLOSURE. SHEET 144-A9-4-1 | | STAIR DETAIL # 6 ALSO SHOWS THE 2 HOUR SHAFT WALL / | | DROPPED CEILING ASSEMBLY BUT WITH A 2 HOUR FIRE RATED | | ACCESS PANEL. SHEET 148-A10-1 DETAIL 14 SHOWS A BLOW UP | | SECTION OF THE RATED SHAFT WALL/ DROPPED CEILING | | ASSEMBLY. | | | | WHAT THE PLANS DO NOT PROVIDE IS WHAT IS LOCATED ABOVE | | THE 2 HOUR SHAFT WALL ASSEMBLY THAT REQUIRES ACCESS? | | PLEASE REVIEW THE 2010 FBC-B 1022.5 PENETRATIONS. | | PENETRATIONS INTO AND OPENINGS THROUGH INTERIOR EXIT | | STAIRWAYS AND RAMPS ARE PROHIBITED EXCEPT FOR REQUIRED | | EXIT DOORS, EQUIPMENT AND DUCTWORK NECESSARY FOR | | INDEPENDENT VENTILATION OR PRESSURIZATION, SPRINKLER | | PIPING, STANDPIPES, ELECTRICAL RACEWAY FOR FIRE | | DEPARTMENT COMMUNICATION SYSTEMS AND ELECTRICAL RACEWAY | | SERVING THE INTERIOR EXIT STAIRWAY AND RAMP AND | | TERMINATING AT A STEEL BOX NOT EXCEEDING 16 SQUARE | | INCHES (0.010 M2). SUCH PENETRATIONS SHALL BE PROTECTED | | IN ACCORDANCE WITH SECTION 714. THERE SHALL BE NO | | PENETRATIONS OR COMMUNICATING OPENINGS, WHETHER | | PROTECTED OR NOT, BETWEEN ADJACENT INTERIOR EXIT | | STAIRWAYS. | | | | 2) PLEASE ALSO REFER TO THE MECHANICAL REVIEW, IN | | REGARDS TO SHEET M2-6-1 SEE CODE SECTION 1104.2 | | INDICATE THE TYPE AND AMOUNT OF REFRIGARATION IN THE | | SYSTEMCONTAINED IN THENEW MECHANICAL ROOM. FIRE RATED | | MACHINERY ROOMS MAYBE REQUIRED AND ADDITIONAL | | REQUIREMENTS PER 1104 & 1105 MAYBE APPLICABLE TO THE | | INSTALATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2017-03-06 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2017-03-06 |
Time |
07:43 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2017-03-06 |
Time |
07:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2017-01-06 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2017-01-06 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2017-01-06 |
Time |
10:10 |
Sent To |
|
|
Notes |
2017-01-06 10:28:51 | PLEASE HAVE EOR SIGN AND SEAL ELECTRONICALLY ALL | | ELECTRICAL SHEETS FOR AN APPROVAL. | | | | V.PEREZ |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2016-07-20 |
|
|
Cont ID |
|
Sent By |
malbarra |
Date |
2016-07-20 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-07-19 |
Time |
18:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2016-07-20 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2016-07-20 |
Time |
16:19 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2016-07-20 |
Time |
16:05 |
Sent To |
|
|
Notes |
2016-07-20 16:19:14 | PERMIT #16061439 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | 1) REVIEW BY ENGINEER OF RECORD AND/OR FIRE ALARM AND | | FIRE SPRINKLER CONTACTORS MAY BE NEEDED TO ENSURE THAT | | CHANGES DO NOT AFFECT PLANS FOR FIRE PROTECTION | | SYSTEMS, AS APPROVED. | | | | 2) SUBMIT REVISIONS FOR FIRE PROTECTION SYSTEMS, IF | | NEEDED. | | | | | | SUE ELLEN CALDERON | | ASSISTANT FIRE MARSHAL | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 804-4751 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2017-03-10 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-03-10 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-03-02 |
Time |
09:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-01-27 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-01-27 |
Time |
11:03 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-12-27 |
Time |
14:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-11-07 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2016-11-07 |
Time |
09:32 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2016-10-14 |
Time |
10:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-08-18 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2016-08-18 |
Time |
08:42 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2016-07-18 |
Time |
16:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2017-03-10 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-03-10 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-03-09 |
Time |
10:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2017-01-27 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-01-27 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-01-27 |
Time |
07:08 |
Sent To |
|
|
Notes |
2017-01-27 11:02:05 | 3RD REVIEW FBC-2014 MECHANICAL | | PERMIT #16061439 | | 1/27/17 | | | | 1) THE REVISED PLANS AND ENERGYGAUGE COMPLIANCE FORM | | EACH REQUIRE DIGITAL SIGNATURES. | | | | 2) REVISE SHEETS M4.02 & M4.07 IN ACCORDANCE WITH THE | | FAN CHANGES AND PRESSURIZATION METHOD FOR STAIRWELL #2. | | | | 3) PROVIDE A SUBMITTAL FOR THE NEW PRESSURIZATION FANS | | SPF-1-1 & SPF 6-1. | | | | 4) THE FOLLOWING LIST OF REVISED APARTMENT PLANS APPEAR | | TO SHOW DRYER EXHAUST DUCTS RUNNING THROUGH RETURN AIR | | PLENUMS WHICH IS PROHIBITED PER SECTION 504.4.: SHEETS | | M3-1-1, 3-2-1, 3-3-1, 3-10-1, 3-14-1, & 3-15-1. | | | | 5) THE SUBMITTED REVISION NARRATIVE DID NOT COMPLETELY | | LIST ALL THE CHANGES SHOWN IN THE REVISED PLANS. PLEASE | | PROVIDE A COMPLETE NARRATIVE WITH THE RESUBMITTED | | PLANS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2016-10-26 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-10-26 |
Time |
14:04 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-10-26 |
Time |
10:55 |
Sent To |
|
|
Notes |
2016-10-26 14:28:50 | 2ND REVIEW FBC-2010 MECHANICAL | | PERMIT #16061439 | | 10/25/16 | | | | 1) SHEET M-2-6-1: THE EXHAUST FROM EF-2 SHALL DISCHARGE | | TO THE OUTDOORS PER SECTION 501.2 FBC-10 MECHANICAL | | (CORRECTION OF COMMENT #2 FROM THE 1ST REVIEW). | | | | 2) M-2-6-1: PLEASE PROVIDE DOCUMENTATION FROM CARRIER | | INDICATING THE EXTERIOR CONDENSER UNITS MAY BE | | INSTALLED INDOORS AND ARE COMPLIANT WITH MANUFACTURER'S | | SPECIFICATIONS. | | | | 3) A2.6.2: PLEASE TAG THE WALLS ENCLOSING THE NEW MECH | | RM AND INCLUDE THE WALLS IN THE LEGEND. REFER TO | | SECTION 304.6 EXCEPTION AND VERIFY COMPLIANCE FOR | | VEHICULAR IMPACT PROTECTION. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-07-26 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-07-26 |
Time |
08:43 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-07-26 |
Time |
08:43 |
Sent To |
|
|
Notes |
2016-07-26 08:48:33 | 1ST REVIEW MECHANICAL | | REVISION #16061439 | | MASTER #15031312 | | 7/16/16 | | | | 1) SHEETS M2-3-1, 4-1, 5-1, 6-1: INDICATE THE TYPE OF | | DUCTWORK TO BE INSTALLED IN THE GARAGE AND THE | | CLEARANCE HEIGHTS FROM FINISHED FLOOR TO BOTTOM OF THE | | DUCTS. REFER TO SMACNA DUCT CONSTRUCTION STANDARDS- | | 2005, AND SECTION 304.6 FBC-14 MECHANICAL. | | | | 2) M2-6-1: THE EXHAUST FROM EF-2 SHALL DISCHARGE TO THE | | OUTDOORS- SEE SECTION 501.3 AND REVISE THE PLAN. | | | | 3 ) M2-6-1: PROVIDE AN EXHAUST VENTILATION CALCULATION | | FOR GEF-6-2, PROVIDE A SEQUENCE OF OPERATION FOR THE | | FAN, AND SHOW HOW MAKEUP AIR IS BEING PROVIDED FOR THE | | EXHAUST. | | | | 4) M2-6-1: REFER TO SECTION 1104.2 AND INDICATE THE | | TYPE AND AMOUNT OF REFRIGERANT IN THE SYSTEMS CONTAINED | | IN THE NEW MECHANICAL ROOM. PLEASE NOTE A FIRE-RATED | | MACHINERY ROOM MAY BE REQUIRED, AND ADDITIONAL | | REQUIREMENTS PER SECTIONS 1104 AND 1105 MAY BE | | APPLICABLE TO THE INSTALLATION. SUBMIT MANUFACTURER'S | | SPECIFICATIONS FOR THE CONDENSERS- THE UNITS SHALL BE | | INSTALLED IN ACCORDANCE WITH THEIR LISTING OR PER | | MANUFACTURER'S INSTRUCTIONS. | | | | 5) M2-6-1 SHOWS THE 8 CONDENSER UNITS TO BE RELOCATED | | ARE CU TYPES 3, 4A, AND 5A, HOWEVER SHEET M2.91 SHOWS | | THE UNIT TYPES RELOCATED WERE CU'S 2 & 3. | | | | 6) M2-1-1 & M4.00: THE TRASH ROOM AC HAS BEEN CHANGED | | TO A 1.5 TON SYSTEM, HOWEVER THE AC AND ENERGY | | CALCULATIONS INDICATE A 5TON SYSTEM. | | | | 7) M3.1.1: THE 32X6 AND 16X12 RETURN AIR TRANSFERS FROM | | BEDROOM 301.04 ARE UNDERSIZED PER SECTION 601.5 | | EXCEPTIONS 2 & 3. A) THE 36X12 TRANSFER AT THE MAIN AC | | PLENUM IS ALSO UNDERSIZED PER 601.5 EXCEPTION 2. | | | | 8) M3.2.1: INDICATE HOW THE SUPPLY AIR FOR THE AC-3 | | SYSTEMS IS BEING RETURNED TO THE UNITS IN THE CLOSETS- | | SEE SECTION 602.1 FOR PLENUM REQUIREMENTS AND | | LIMITATIONS. | | | | 9) M3.3.1: SEE COMMENT #8 ABOVE AS IT PERTAINS TO | | AC-4A. | | | | 10) ADVISORY: PLEASE REVIEW THE RETURN AIR SYSTEMS FOR | | THE APARTMENTS SHOWN ON MASTER PLAN SHEETS M3.10.1, | | M3.14.01, M.3.15.1 AND M3.16.1- PERMIT #15031312. IT | | APPEARS THAT SOME OF THE RETURN AIR AND TRANSFER GRILLS | | SHOWN ARE UNDERSIZED PER SECTION 601.5. PLEASE REVIEW | | AND REVISE | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2017-01-23 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-01-23 |
Time |
12:46 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-01-23 |
Time |
12:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2016-11-02 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-11-02 |
Time |
12:34 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-11-02 |
Time |
10:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2016-08-17 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-08-06 |
Time |
11:14 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-08-06 |
Time |
04:15 |
Sent To |
|
|
Notes |
2016-08-06 05:57:17 | NARRATIVE: | | 1) NUMBER 039 ON NARRATIVE -SHEET A2.3.2 - NARRATIVE | | STATES THAT NEW PLUMBING WAS ADDED IN CORRIDOR 207 | | OUTSIDE DINING 302.03. CLARIFY WHAT PLUMBING WAS ADDED | | AND THERE DOES NOT APPEAR TO BE A "CORRIDOR 207" ON THE | | PLAN. CLARIFY. | | 2) NUMBERS ON NARRATIVE 045 (A2.5.2), 051 ( A2.7.2), | | 054 (A2.8.2), 077 (A6.1.1), 078 (A6.1.2), 080 (A6.2.1), | | 083 (A6.3.1), 097 (A6.8.1), 100 ( A6.9.1), 103 | | (A6.10.1), 106 (A611.1), 108 (A.6.12.1), 111 (A6.13.1) | | THE NARRATIVE STATES "UNITS MODIFIED PER FHA REVIEW." | | WHAT EXACTLY HAS BEEN MODIFIED IN THESE UNITS. BE | | SPECIFIC.WPB AMEND. TO FBC SEC. 107.2.1. | | 3) NUMBER 119 ( A6.16.1) ON NARRRATIVE - NOTES | | "EQUIPMENT ADDED AT COMMON ROOM 701.04". THERE DOES NOT | | APPEAR TO BE ROOM WITH THIS NUMBER ON THE PLAN AND | | SPECIFY WHAT EQUIPMENT WAS ADDED. WPB AMEND. TO FBC | | SEC. 107.2.1. | | 4) NUMBERS 122 (A6.17.1) & 124 (A6.18.1) - SPECIFY | | WHATT WAS REVISED ON THE PLANS. WPB AMEND. TO FBC SEC. | | 107.2.1. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2017-04-04 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2017-04-04 |
Time |
15:38 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2017-04-04 |
Time |
15:38 |
Sent To |
|
|
Notes |
2017-03-16 10:54:37 | 3/15/17 - GAVE PEDDS TO JWITMER | 2017-01-30 10:33:48 | **APPLICANT WILL BE SUBMITTING PEDDS FOR DIGITAL | | SIGNATURE** |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2017-01-27 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-01-27 |
Time |
11:05 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-01-27 |
Time |
11:05 |
Sent To |
|
|
Notes |
2017-01-27 11:05:08 | THE REVISED MECHANICAL PLANS AND ENERGY CALCULATIONS | | ARE NOT ELECTRONICALLY SIGNED AND SEALED. | | CCOLE/1/27/17 | 2016-08-05 16:46:27 | 1ST REVIEW CYCLE. ARCHITECTURAL & STRUCTURAL SHEETS | | HAVE NOT BEEN ELECTRONICALLY SIGNED AND SEALED. | | 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING | | ELECTRONICALLY TRANSMITTED PLANS, SPECIFICATIONS, | | REPORTS OR OTHER DOCUMENTS (ELECTRONIC SEALS). |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2016-08-18 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2016-08-18 |
Time |
08:35 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2016-08-18 |
Time |
08:34 |
Sent To |
|
|
Notes |
|
|