Plan Review Details - Permit 16061385
Plan Review Stops For Permit 16061385
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-07-19 Cont ID  
Sent By ccole Date 2016-07-19 Time 07:05 Rev Time 0.00
Received By ccole Date 2016-07-19 Time 07:05 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-07-18 Cont ID  
Sent By jwitmer Date 2016-07-18 Time 08:36 Rev Time 0.00
Received By jwitmer Date 2016-07-18 Time 08:11 Sent To  
Notes
2016-07-18 08:36:16BUILDING PLAN REVIEW
 W. P. B. REVISION: 16061385
 W. P. B. PERMIT: 16041215
 ADD: 2001 S. DIXIE HWY.
 CONT: MAC ENTERPRISES
 TEL: 561-236-3627
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: MON. JULY 18/ 2016
 ACTION: BUILDING PROVISO
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 SHEET A601 DETAIL TYPICAL DOOR PLAQUE ELEVATIONS SHOWS
 THE CENTER OF THE PLAQUE CENTERLINED AT 60 INCHES FROM
 FINISH FLOOR. THE PLAUGE HAS THE NAME THEN BENEATH
 BRAILE. PLEASE BE ADVISED OF THE 2014 FBC-ACCESS. CODE
 703.4.1 HEIGHT ABOVE FINISH FLOOR OR GROUND. AND FIGURE
 703.4.1. TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED
 48 INCHES (1220 MM) MINIMUM ABOVE THE FINISH FLOOR OR
 GROUND SURFACE, MEASURED FROM THE BASELINE OF THE
 LOWEST TACTILE CHARACTER AND 60 INCHES (1525 MM)
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE,
 MEASURED FROM THE BASELINE OF THE HIGHEST TACTILE
 CHARACTER.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-07-06 Cont ID  
Sent By jwitmer Date 2016-07-06 Time 07:00 Rev Time  
Received By jwitmer Date 2016-07-06 Time 06:29 Sent To  
Notes
2016-07-06 07:00:12BUILDING PLAN REVIEW
 W. P. B. REVISION: 16061385
 W. P. B. PERMIT: 16041215
 ADD: 2001 S. DIXIE HWY.
 CONT: MAC ENTERPRISES
 TEL: 561-236-3627
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. JULY 06/ 2016
 ACTION: DENIED
  
 1) SHEET A201 THE SOUTH ELEVATION THE NEW WINDOWS(206)
 ON THE 2ND FLOOR, THE WINDOW THAT IS WITHIN 10 FEET OF
 THE 2ND FLOOR LANDING REQUIRES 45 MINUTE FIRE RATED
 UNIT. SHEET 610 WINDOW SCHEDULE DOES NOT INDICATE A 45
 MIN. FIRE RATED UNIT. 2014 FBC-B 1026.6.
  
  
 2) THE STRUCTURAL SHEETS HAVE NOT BEEN UPDATED FOR NEW
 COLUMNS AT EACH SIDE OF THE WINDOWS NOR BEAM OR LINTEL
 SCHEDULE FOR THE NEW OPENINGS.
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION 107.2.1.3 107.3.5 MINIMUM
 107.3.5.1 COMMERCIAL BUILDINGS:
 WIND REQUIREMENTS PRESSURES / NEW OPENINGS
 BUILDING ENVELOPE/ PRODUCT APPROVALS
 STRUCTURAL ELEMENTS, COLUMNS. BEAMS AND OR LINTELS.
  
 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-07-20 Cont ID  
Sent By vperez Date 2016-07-20 Time 05:43 Rev Time 0.00
Received By vperez Date 2016-07-19 Time 17:14 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-07-06 Cont ID  
Sent By vperez Date 2016-07-06 Time 15:42 Rev Time 0.00
Received By vperez Date 2016-07-06 Time 15:42 Sent To  
Notes
2016-07-06 15:42:35INITIAL ELECTRICAL PLAN REVIEW
  
 APPLICABLE CODES IN EFFECT:
 FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70- 2011 NEC
 COMMENTS:
  
 1. PROVISO- SUBMIT REVISED ENERGY CALC REFLECTING ADDED
 LIGHTING LOADS.
 2. PLEASE FEEL FREE TO CONTACT ME SHOULD YOU HAVE ANY
 QUESTIONS REGARDING THIS PROJECT.
  
  
 VALENTINO PEREZ
 ELECTRICAL PLANS EXAMINER II
 561-805-6717
 [email protected]
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2016-07-20 Cont ID  
Sent By wjolin Date 2016-07-20 Time 14:29 Rev Time 0.00
Received By wjolin Date 2016-07-20 Time 14:29 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2016-06-29 Cont ID  
Sent By wjolin Date 2016-06-29 Time 15:13 Rev Time 0.00
Received By wjolin Date 2016-06-29 Time 15:13 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-07-23 Cont ID  
Sent By tklarge Date 2016-07-23 Time 05:34 Rev Time 0.00
Received By tklarge Date 2016-07-14 Time 13:33 Sent To  
Notes
2016-07-14 13:33:23B20

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-07-08 Cont ID  
Sent By cpuell Date 2016-07-08 Time 13:56 Rev Time 0.00
Received By cpuell Date 2016-06-24 Time 14:48 Sent To  
Notes
2016-06-24 14:49:01B26

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2016-07-19 Cont ID  
Sent By ccole Date 2016-07-19 Time 07:49 Rev Time 0.00
Received By ccole Date 2016-07-18 Time 17:15 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-06-28 Cont ID  
Sent By ccole Date 2016-06-28 Time 12:48 Rev Time 0.00
Received By ccole Date 2016-06-28 Time 12:48 Sent To  
Notes
2016-06-28 12:53:151ST REVIEW: FBC 2014 MECHANICAL
 PERMIT #16061385
 6/28/16
  
 1) THE ENERGY CALCULATIONS MUST BE REVISED TO REFLECT
 THE CLASSROM AREA EXPANSION AND THE AC ALTERATIONS AND
 NEW SYSTEM.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2016-07-23 Cont ID  
Sent By gjohnson Date 2016-07-23 Time 05:33 Rev Time 0.00
Received By tklarge Date 2016-07-23 Time 04:55 Sent To  
Notes
2016-07-23 05:33:111) I CANNOT FIND ON THE PLANS WHERE THE REVIEW COMMENTS
 FROM THE 7/2/16 HAVE BEEN ADRESSED. SUBMIT A NARRATIVE
 FOR THE PLAN REVIEW COMMENTS AND HOW THEY HAVE BEEN
 ADDRESSED.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-07-02 Cont ID  
Sent By gjohnson Date 2016-07-02 Time 08:28 Rev Time 0.00
Received By gjohnson Date 2016-07-02 Time 08:28 Sent To  
Notes
2016-07-02 08:48:271ST REVIEW
  
  
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
  
 PLUMBING COMMENTS:
  
 1. PROVIDE DIMENSION OF DRINKING WATER SPOUT ON
 CLASSROOM SINK FROM FRONT EDGE TO SPOUT SHALL COMPLY
 WITH FBC AC 602.2 EXCEPTION: A PARALLEL APPROACH
 COMPLYING WITH 305 SHALL BE PERMITTED AT UNITS FOR
 CHILDREN?S USE WHERE THE SPOUT IS 30 INCHES (760 MM)
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND AND IS 31/2
 INCHES (90 MM) MAXIMUM FROM THE FRONT EDGE OF THE UNIT,
 INCLUDING BUMPERS.
  
 2. PROVIDE DETAIL FOR HANGING WATER HEATER IT WILL
 WEIGH ABOUT 700LB. PER WPB AMEND. TO FBC 107.2.1
  
 COMPLY WITH PROVISO FROM ORIGINAL PLAN:
  
 4 OF THE 9 DRINKING FOUNTAINS SHALL COMPLY WITH FBC
 ACC. SEC. 602.7 DRINKING FOUNTAINS FOR STANDING
 PERSONS.
 SPOUT OUTLETS OF DRINKING FOUNTAINS FOR STANDING
 PERSONS SHALL BE 38 INCHES (965 MM) MINIMUM AND 43
 INCHES (1090 MM) MAXIMUM ABOVE THE FINISH FLOOR OR
 GROUND.
 TO MEET THE REQUIREMENTS OF FBC ACC. SEC.
 211.3 MORE THAN MINIMUM NUMBER.
 WHERE MORE THAN THE MINIMUM NUMBER OF DRINKING
 FOUNTAINS SPECIFIED IN 211.2 ARE PROVIDED, 50 PERCENT
 OF THE TOTAL NUMBER OF DRINKING FOUNTAINS PROVIDED
 SHALL COMPLY WITH 602.1 THROUGH 602.6, AND 50 PERCENT
 OF THE TOTAL NUMBER OF DRINKING FOUNTAINS PROVIDED
 SHALL COMPLY WITH 602.7.

Review Stop Z ZONING
Rev No 1 Status P Date 2016-07-08 Cont ID  
Sent By llouie Date 2016-07-08 Time   Rev Time 0.00
Received By llouie Date 2016-07-08 Time   Sent To  
Notes
2016-07-08 12:50:02ZONING APPROVED WITH THE FOLLOWING PROVISO:
  
 1.) ALL ROOFTOP EQUIPMENT SHALL BE SCREENED/HIDDEN FROM
 VIEW BY THE PARAPET.
  
  
 NOTE:
  
 * SCHOOL USE PERMITTED IN GENERAL COMMERCIAL (GC)
 ZONING DISTRICT.
  