Plan Review Details - Permit 16061309
Plan Review Stops For Permit 16061309
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-07-25 Cont ID  
Sent By shill Date 2016-07-25 Time 17:35 Rev Time 0.00
Received By shill Date 2016-07-25 Time 17:35 Sent To  
Notes
2016-07-25 17:35:43SEE MASTER 16070669
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-07-06 Cont ID  
Sent By shill Date 2016-07-06 Time 14:22 Rev Time 0.00
Received By shill Date 2016-07-06 Time 11:47 Sent To  
Notes
2016-07-06 14:25:11****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. ENGINEER IS TO REVIEW THE TAS-105 TEST AND REVISE
 RAS117 CALCULATIONS (ENGINEERING), FBC 5TH ED.
 RESIDENTIAL 301.
  
 2. THE PRODUCT APPROVAL PAGES ARE REDUCED AND DIFFICULT
 TO READ. PLEASE RE-PRINT THE REDUCED PAGES IN LANDSCAPE
 ORIENTATION, FBC 107.
  
 3. PERMIT 13100612 IS EXPIRED, PLEASE ADDRESS. PROVIDE
 A COPY OF THE PERMIT CARD, IF AVAILABLE, OR APPLY FOR A
 "REISSUE" PERMIT AT THE BUILDING DIVISION.
  
 4. RESUB FORM STATES THAT THIS IS FOR "NEW MASTER
 PLAN." PERMIT APPLICATION 16061309 IS ASSOCIATED WITH A
 PARCEL AND IS NOT A MASTER PERMIT. IF YOU WOULD LIKE TO
 APPLY FOR A MASTER PERMIT, SUBMIT A PERMIT APPLICATION
 AT THE BUILDING DIVISION WITY SEVERAL SETS OF ORIGINAL
 SIGNED AND SEALED DOCUMENTS. AFTER THAT MASTER PERMIT
 IS ISSUED, THE PERMITS APPLIED FOR TO DATE CAN BE
 ISSUED USING THE MASTER.
  
 OR, APPLICANT MAY RESUBMIT UNDER EACH APPLICATION.
  
 5. PER K.CONRAD, USE OF THE WITHDRAWAL TEST PERFORMED
 IN 2015 IS ACCEPTABLE (NO NEW TEST REQUIRED). HOWEVER,
 PLEASE HAVE THE TEST REPORT REVISED TO INCLUDE THE
 BRAND OF FASTENER TESTED.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-06-23 Cont ID  
Sent By shill Date 2016-06-23 Time 14:55 Rev Time 0.00
Received By shill Date 2016-06-23 Time 14:55 Sent To  
Notes
2016-06-23 15:00:15****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR
 PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS, FS471.
  
 THE APPLICATION REFERS TO A MASTER. WHEN A MASTER IS ON
 FILE, PERMITS SHOULD BE ISSUED USING THE MASTER AND NEW
 DOCUMENTS SHOULD NOT BE SUBMITTED. THE MASTER WAS
 REVIEWED UNDER A PREVIOUS BUILDING CODE. A MASTER PLAN
 EXPIRES WHEN THE BUILDING CODE IS CHANGED AS REQUIRED
 BY FLORIDA STATUTE. (SEE NOTES ON THE MASTER PERMIT)
  
 2. THE PRODUCT APPROVALS PROVIDED ARE EXPIRED (FBC
 2010).
  
 A COMPLETE REVIEW WILL BE PERFORMED AFTER CURRENT
 PRODUCT APPROVALS AND UPDATED ENGINEERING DOCUMENTS ARE
 SUBMITTED.
  
 APPLICANT CAN EITHER APPLY FOR A NEW MASTER, AND HAVE
 THESE PERMITS ISSUED USING THE NEW MASTER, OR RESUBMIT
 NEW DOCUMENTS FOR THE INDIVIDUAL PERMITS.
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-07-06 Cont ID  
Sent By shill Date 2016-07-06 Time 14:25 Rev Time 0.00
Received By shill Date 2016-07-06 Time 08:32 Sent To  
Notes
2016-07-06 08:32:27SHILL'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-06-23 Cont ID  
Sent By cpuell Date 2016-06-23 Time 16:35 Rev Time 0.00
Received By cpuell Date 2016-06-23 Time 16:35 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved