Plan Review Details - Permit 16061288
Plan Review Stops For Permit 16061288
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-07-21 Cont ID  
Sent By cthroop Date 2016-07-21 Time 14:06 Rev Time 0.00
Received By cthroop Date 2016-07-21 Time 14:06 Sent To M
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2016-06-27 Cont ID  
Sent By cthroop Date 2016-06-27 Time 11:21 Rev Time 0.00
Received By cthroop Date 2016-06-27 Time 11:21 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-07-11 Cont ID  
Sent By vperez Date 2016-07-11 Time 15:18 Rev Time 0.00
Received By vperez Date 2016-07-11 Time 15:17 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-06-23 Cont ID  
Sent By cpuell Date 2016-06-28 Time 09:53 Rev Time 0.00
Received By vperez Date 2016-06-23 Time 10:48 Sent To P
Notes
2016-06-23 10:49:12INITIAL ELECTRICAL PLAN REVIEW
  
 APPLICABLE CODES IN EFFECT:
 FLORIDA RES BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70- 2011 NEC
 COMMENTS:
  
 1. PLEASE HAVE AOR SIGN AND SEAL ELECTRICAL SHEET
 SUBMITTED. FBC 105
 2. PROVIDE AND SHOW IF THERE ARE EXISTING SMOKE
 DETECTORS, IF NOT SHOW TO COMPLY WITH FBC RES 314 & 315
 3. PROVIDE DATA SPEC SHEETS FOR TANKLESS WH BEING
 INSTALLED. FBC 107.3.5
 4. FURTHER COMMENTS MAY FOLLOW UPON RE-REVIEW. FEEL
 FREE TO CONTACT ME AT THE NUMBER BELOW SHOULD YOU HAVE
 ANY QUESTIONS OR CONCERN.
  
  
  
 VALENTINO PEREZ
 ELECTRICAL PLANS EXAMINER II
 561-805-6717
 [email protected]
  
  

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2016-07-21 Cont ID  
Sent By gjohnson Date 2016-07-21 Time 13:13 Rev Time 0.00
Received By gjohnson Date 2016-07-21 Time 13:13 Sent To  
Notes
2016-07-21 13:14:21PLUMBING AND GAS PROVISO:
 PROVIDE APPROVED GAS AND PLUMBING RISER DIAGRAMS FOR
 ROUGH INSPECTIONS FAILURE TO DO SO WILL RESULT IN
 FAILED INSPECTIONS AND REINSPECTION FEES.
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2016-06-24 Cont ID  
Sent By gjohnson Date 2016-06-24 Time 14:21 Rev Time 0.00
Received By gjohnson Date 2016-06-24 Time 14:21 Sent To  
Notes
2016-06-24 14:46:361ST REVIEW
  
  
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
  
 GAS COMMENTS;
  
  
 1. GAS RISER DOES NOT CLEARLY SHOW EXISTING POOL HEATER
 SHOW LOCATION OF EXISTING POOL HEATER ON RISER. PER WPB
 AMEND. TO FBC SEC. 107.2.1
  
 2. CLEARLY INDICATE PRESSURE OF SYSTEM.PER FBC-2014
 FUEL GAS SEC. 402.2.
  
 3. THE EXISTING 3/4 FROM METER TI FIRST TEE NEEDS TO BE
 INCREASED TO 1IN. PER FBC FUEL GAS TABLE TABLE 402.4(1)
  
 4. INDICATE WHAT SIZING TABLES YOU ARE USING. PER WPB
 AMEND. TO FBC SEC. 107.2.1

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-07-21 Cont ID  
Sent By cpuell Date 2016-07-21 Time 16:41 Rev Time 0.00
Received By cpuell Date 2016-07-05 Time 10:32 Sent To  
Notes
2016-07-06 10:32:55R12

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-06-28 Cont ID  
Sent By cpuell Date 2016-06-28 Time 09:53 Rev Time 0.00
Received By cpuell Date 2016-06-22 Time 09:51 Sent To E
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2016-07-21 Cont ID  
Sent By jvalido Date 2016-07-21 Time 15:55 Rev Time 0.00
Received By jvalido Date 2016-07-21 Time 15:30 Sent To  
Notes
2016-08-03 14:27:07PLAN IS NOTED AS MECHANICAL INSPECTION REQUIRED. THIS
 IS AN ADMINISTRATIVE DETERMINATION THAT THE NOTE DOES
 NOT MEAN THAT A MECHANICAL SUB PERMIT OR CONTRACTOR IS
 REQUIRED FOR THIS WORK. THE INSPECTION MAY BE PART OF
 THE BUILDING INSPECTOR DUTIES. CONTRACTOR TO INFORM
 INSPECTOR AND WE GO FROM THERE.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2016-06-27 Cont ID  
Sent By jvalido Date 2016-06-27 Time 16:50 Rev Time 0.00
Received By jvalido Date 2016-06-27 Time 16:32 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-07-21 Cont ID  
Sent By gjohnson Date 2016-07-21 Time 13:14 Rev Time 0.00
Received By gjohnson Date 2016-07-21 Time 13:14 Sent To  
Notes
2016-07-21 13:14:55PLUMBING AND GAS PROVISO:
 PROVIDE APPROVED GAS AND PLUMBING RISER DIAGRAMS FOR
 ROUGH INSPECTIONS FAILURE TO DO SO WILL RESULT IN
 FAILED INSPECTIONS AND REINSPECTION FEES.
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-06-24 Cont ID  
Sent By gjohnson Date 2016-06-24 Time 14:46 Rev Time 0.00
Received By gjohnson Date 2016-06-24 Time 14:46 Sent To  
Notes
2016-06-24 14:52:031ST REVIEW
  
  
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
  
 PLUMBING COMMENTS:
  
 1. THE LAUNDRY DRAIN SHALL CONNECT TO BUILDING DRAIN
 DOWNSTEAM OF BATHROOM GROUP. PER FBC RES. P3108.1


Account Summary | Usage Policy | Privacy Policy