Plan Review Stops For Permit 16061288 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2016-07-21 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-07-21 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-07-21 |
Time |
14:06 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2016-06-27 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-06-27 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-06-27 |
Time |
11:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2016-07-11 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-07-11 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-07-11 |
Time |
15:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-06-23 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2016-06-28 |
Time |
09:53 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-06-23 |
Time |
10:48 |
Sent To |
P |
|
Notes |
2016-06-23 10:49:12 | INITIAL ELECTRICAL PLAN REVIEW | | | | APPLICABLE CODES IN EFFECT: | | FLORIDA RES BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70- 2011 NEC | | COMMENTS: | | | | 1. PLEASE HAVE AOR SIGN AND SEAL ELECTRICAL SHEET | | SUBMITTED. FBC 105 | | 2. PROVIDE AND SHOW IF THERE ARE EXISTING SMOKE | | DETECTORS, IF NOT SHOW TO COMPLY WITH FBC RES 314 & 315 | | 3. PROVIDE DATA SPEC SHEETS FOR TANKLESS WH BEING | | INSTALLED. FBC 107.3.5 | | 4. FURTHER COMMENTS MAY FOLLOW UPON RE-REVIEW. FEEL | | FREE TO CONTACT ME AT THE NUMBER BELOW SHOULD YOU HAVE | | ANY QUESTIONS OR CONCERN. | | | | | | | | VALENTINO PEREZ | | ELECTRICAL PLANS EXAMINER II | | 561-805-6717 | | [email protected] | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2016-07-21 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-07-21 |
Time |
13:13 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-07-21 |
Time |
13:13 |
Sent To |
|
|
Notes |
2016-07-21 13:14:21 | PLUMBING AND GAS PROVISO: | | PROVIDE APPROVED GAS AND PLUMBING RISER DIAGRAMS FOR | | ROUGH INSPECTIONS FAILURE TO DO SO WILL RESULT IN | | FAILED INSPECTIONS AND REINSPECTION FEES. | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2016-06-24 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-06-24 |
Time |
14:21 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-06-24 |
Time |
14:21 |
Sent To |
|
|
Notes |
2016-06-24 14:46:36 | 1ST REVIEW | | | | | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | | | GAS COMMENTS; | | | | | | 1. GAS RISER DOES NOT CLEARLY SHOW EXISTING POOL HEATER | | SHOW LOCATION OF EXISTING POOL HEATER ON RISER. PER WPB | | AMEND. TO FBC SEC. 107.2.1 | | | | 2. CLEARLY INDICATE PRESSURE OF SYSTEM.PER FBC-2014 | | FUEL GAS SEC. 402.2. | | | | 3. THE EXISTING 3/4 FROM METER TI FIRST TEE NEEDS TO BE | | INCREASED TO 1IN. PER FBC FUEL GAS TABLE TABLE 402.4(1) | | | | 4. INDICATE WHAT SIZING TABLES YOU ARE USING. PER WPB | | AMEND. TO FBC SEC. 107.2.1 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-07-21 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2016-07-21 |
Time |
16:41 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2016-07-05 |
Time |
10:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-06-28 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2016-06-28 |
Time |
09:53 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2016-06-22 |
Time |
09:51 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
N |
Date |
2016-07-21 |
|
|
Cont ID |
|
Sent By |
jvalido |
Date |
2016-07-21 |
Time |
15:55 |
Rev Time |
0.00 |
Received By |
jvalido |
Date |
2016-07-21 |
Time |
15:30 |
Sent To |
|
|
Notes |
2016-08-03 14:27:07 | PLAN IS NOTED AS MECHANICAL INSPECTION REQUIRED. THIS | | IS AN ADMINISTRATIVE DETERMINATION THAT THE NOTE DOES | | NOT MEAN THAT A MECHANICAL SUB PERMIT OR CONTRACTOR IS | | REQUIRED FOR THIS WORK. THE INSPECTION MAY BE PART OF | | THE BUILDING INSPECTOR DUTIES. CONTRACTOR TO INFORM | | INSPECTOR AND WE GO FROM THERE. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2016-06-27 |
|
|
Cont ID |
|
Sent By |
jvalido |
Date |
2016-06-27 |
Time |
16:50 |
Rev Time |
0.00 |
Received By |
jvalido |
Date |
2016-06-27 |
Time |
16:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2016-07-21 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-07-21 |
Time |
13:14 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-07-21 |
Time |
13:14 |
Sent To |
|
|
Notes |
2016-07-21 13:14:55 | PLUMBING AND GAS PROVISO: | | PROVIDE APPROVED GAS AND PLUMBING RISER DIAGRAMS FOR | | ROUGH INSPECTIONS FAILURE TO DO SO WILL RESULT IN | | FAILED INSPECTIONS AND REINSPECTION FEES. | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2016-06-24 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-06-24 |
Time |
14:46 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-06-24 |
Time |
14:46 |
Sent To |
|
|
Notes |
2016-06-24 14:52:03 | 1ST REVIEW | | | | | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | 1. THE LAUNDRY DRAIN SHALL CONNECT TO BUILDING DRAIN | | DOWNSTEAM OF BATHROOM GROUP. PER FBC RES. P3108.1 |
|
|