Plan Review Stops For Permit 16061268 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2017-02-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-02-06 |
Time |
14:03 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-02-06 |
Time |
14:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2017-01-19 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2017-01-19 |
Time |
14:34 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2017-01-19 |
Time |
14:34 |
Sent To |
B |
|
Notes |
2017-01-12 12:45:45 | SENT TO PLUMBING FIRST | | | | VP |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2016-08-01 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-08-01 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-08-01 |
Time |
10:04 |
Sent To |
|
|
Notes |
2016-08-01 10:06:08 | 2ND ELECTRICAL PLAN REVIEW | | | | APPLICABLE CODES IN EFFECT: | | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70- 2011 NEC | | PENDING COMMENTS: | | | | 1. PLEASE ADDRESS PENDING PLUMBING REVIEWER COMMENT FOR | | AN ELECTRICAL APPROVAL. | | 2. COMMENTS MAY FOLLOW UPON RE-REVIEW. PLEASE FEEL FREE | | TO CONTACT ME SHOULD YOU HAVE ANY QUESTIONS REGARDING | | THIS PROJECT. | | | | | | VALENTINO PEREZ | | ELECTRICAL PLANS EXAMINER II | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-06-30 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-06-30 |
Time |
13:29 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-06-30 |
Time |
13:26 |
Sent To |
|
|
Notes |
2016-06-30 13:29:17 | INITIAL ELECTRICAL PLAN REVIEW | | | | APPLICABLE CODES IN EFFECT: | | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70- 2011 NEC | | COMMENTS: | | | | 1. PLEASE ADDRESS PENDING PLUMBING REVIEWER COMMENT FOR | | AN ELECTRICAL APPROVAL. | | 2. COMMENTS MAY FOLLOW UPON RE-REVIEW. PLEASE FEEL FREE | | TO CONTACT ME SHOULD YOU HAVE ANY QUESTIONS REGARDING | | THIS PROJECT. | | | | | | VALENTINO PEREZ | | ELECTRICAL PLANS EXAMINER II | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-02-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-02-06 |
Time |
14:03 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-01-10 |
Time |
14:43 |
Sent To |
|
|
Notes |
2017-01-12 12:46:07 | SENT TO PLUMBING FIRST | 2017-01-10 14:43:30 | RESUB ROUTED TO VPEREZ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-08-01 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-08-01 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-08-01 |
Time |
10:06 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-06-30 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-06-30 |
Time |
13:30 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-06-30 |
Time |
13:30 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2017-01-17 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-01-17 |
Time |
05:15 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-01-17 |
Time |
04:43 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2016-07-29 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-07-29 |
Time |
13:23 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-07-29 |
Time |
12:24 |
Sent To |
|
|
Notes |
2016-07-29 12:57:29 | 1) INDICATE ON THE SPECIFICATION SHEETS WHICH HOSE | | PRODUCT WILL BE USED WITH WHAT CHEMICALS. WPB AMEND. TO | | FBC SEC.107.2.1. | | 2) THE SUBMITTED PLAN SHALL BE SIGNED AND SEALED BY THE | | LANDSCAPE ARCHITECT.FAC 61G10-11.010 | | 3) SHOW THE SIZES OF THE CHEMICAL TANKS ON THE | | PLANS.WPB AMEND. TO FBC SEC.107.2.1. | | 4) SUBMIT DETAILS AS TO HOW THE CHEMICAL TANKS WILL BE | | ANCHORED TO WITHSTAND THE 170 MPH WIND LOAD | | REQUIREMENTS OF 2014 FBC SEC. 1609. | | 5) INDICATE ON THE PLANS THE TYPE OF CONTAINMENT THAT | | IS BEING PROVIDED AND THE CAPACITY OF THE CONTAINMENT | | IN RELATION TO THE SIZE OF THE CHEMICAL TANKS ( 110%, | | 125%, ETC.).WPB AMEND. TO FBC SEC.107.2.1. | | 6) SUBMIT DETAILS AS TO HOW THE PIPING WILL BE ATTACHED | | TO THE CONCRETE PAD | | 7) THE KURIYAMA ORV HOSE IS MADE FROM PVC. SUBMIT | | MANUFACTURER'S SPECIFICATIONS AS TO HOW THE HOSE WILL | | BE PROTECTED FROM UV RAYS IF EXPOSED. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2016-06-30 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-06-30 |
Time |
13:30 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-06-30 |
Time |
05:57 |
Sent To |
|
|
Notes |
2016-06-30 06:11:27 | 1) NONE OF THE REQUIREMENTS OF MY PROVISO HAVE BEEN | | SUBMITTED. SUBMIT COMPLETE PLANS, PIPING DETAILS, PIPE | | SIZES, MSDS INFORMATION,SIGNED AND SEALED DRAWINGS, | | ETC., ETC., | | 2) SUBMIT DRAWINGS THAT ARE LEGIBLE. THE PRINTING ON | | THE 8 1/2 X 11 SHEETS IS TOO SMALL TO READ. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | | | |
|
|