Plan Review Details - Permit 16061249
Plan Review Stops For Permit 16061249 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2016-06-27 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-06-27 |
Time |
15:42 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-06-27 |
Time |
15:30 |
Sent To |
|
|
Notes |
2016-06-27 15:42:54 | GOOD MORNING MR. GOMEZ.? PLEASE CHANGE OUR ROOFING | | SYSTEM FROM W-138 TO W-140 ON THE SAME SUBMITTED PAGE. | | W-140 IS -97.5 | | ALSO, DO YOU HAVE ANY TYPE OF CHART, GUIDE OR MAP THAT | | WILL HELP US FROM MAKING THIS MISTAKE AGAIN? | | _____________________________________________________ | | ARA A.J. GARIBIAN | | 561-215-6620 CELL | | | | 561.337.6798: OFFICE | | 561.585.0051: FAX | | WWW.GARABAR.COM | ROOFING | | GARABAR ON FACEBOOK | LIKE US ON FACEBOOK | | GARABAR ON TWITTER | FOLLOW US ON TWITTER | | | | 425 INDUSTRIAL STREET, SUITE 3 | | LAKE WORTH, FL 33461 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-06-24 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-06-24 |
Time |
17:37 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-06-24 |
Time |
16:27 |
Sent To |
|
|
Notes |
2016-06-24 17:56:17 | RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW COMMENTS. | | CODE: FBC 5TH EDITION (2014). | | | | 1- FLAT ROOF FLORIDA PRODUCT APPROVAL FL1654-R19 | | SUBMITTED: | | THE MAXIMUM DESIGN PRESSURE FOR THE W-138 SELECTED | | ASSEMBLY IS -90 PSF. BONDED ASSEMBLIES DON'T ALLOW | | RATIONAL ANALYSIS TO ENHANCE THE DESIGN PRESSURE. SEE | | NOTE #9 ON PAGE 2 OF 45. ACCORDING TO SEC. R301.2.1.4.3 | | FBC-RESIDENTIAL, 5TH EDITION (2014) THIS BUILDING LOOKS | | LIKE IS LOCATED IN EXPOSURE "C". THE DESIGN PRESSURE | | FOR ZONE #3 IS HIGHER THAN -90 PSF. THEREFORE, THIS | | ASSEMBLY CAN NOT BE USED. THE DESIGN PRESSURE FOR ZONE | | #3 IN EXPOSURE "C" IS +/- 95.7 PSF. PROVIDE ANOTHER | | ASSEMBLY THAT MEETS OR EXCEEDS THE DESIGN PRESSURE FOR | | ALL ROOF ZONES. | | NOTE: IF SELECTING ANOTHER ASSEMBLY THAT IS | | MECHANICALLY FASTENED AND THAT ALLOWS NAIL ENHANCING, | | THEN PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS AS | | REQUIRED. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-06-27 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-06-27 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-06-27 |
Time |
15:30 |
Sent To |
|
|
Notes |
2016-06-27 15:30:51 | RECEIVED E-MAIL FROM CONTRACTOR ADDRESSING COMMENTS. | | JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-06-24 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-06-24 |
Time |
16:46 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-06-22 |
Time |
10:55 |
Sent To |
|
|
Notes |
2016-06-22 10:56:08 | JGOMEZ |
|
|
|