Plan Review Details - Permit 16061249
Plan Review Stops For Permit 16061249
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-06-27 Cont ID  
Sent By jgomez Date 2016-06-27 Time 15:42 Rev Time 0.00
Received By jgomez Date 2016-06-27 Time 15:30 Sent To  
Notes
2016-06-27 15:42:54GOOD MORNING MR. GOMEZ.? PLEASE CHANGE OUR ROOFING
 SYSTEM FROM W-138 TO W-140 ON THE SAME SUBMITTED PAGE.
 W-140 IS -97.5
 ALSO, DO YOU HAVE ANY TYPE OF CHART, GUIDE OR MAP THAT
 WILL HELP US FROM MAKING THIS MISTAKE AGAIN?
 _____________________________________________________
 ARA A.J. GARIBIAN
 561-215-6620 CELL
  
 561.337.6798: OFFICE
 561.585.0051: FAX
 WWW.GARABAR.COM | ROOFING
 GARABAR ON FACEBOOK | LIKE US ON FACEBOOK
 GARABAR ON TWITTER | FOLLOW US ON TWITTER
  
 425 INDUSTRIAL STREET, SUITE 3
 LAKE WORTH, FL 33461
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-06-24 Cont ID  
Sent By jgomez Date 2016-06-24 Time 17:37 Rev Time 0.00
Received By jgomez Date 2016-06-24 Time 16:27 Sent To  
Notes
2016-06-24 17:56:17RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 1- FLAT ROOF FLORIDA PRODUCT APPROVAL FL1654-R19
 SUBMITTED:
 THE MAXIMUM DESIGN PRESSURE FOR THE W-138 SELECTED
 ASSEMBLY IS -90 PSF. BONDED ASSEMBLIES DON'T ALLOW
 RATIONAL ANALYSIS TO ENHANCE THE DESIGN PRESSURE. SEE
 NOTE #9 ON PAGE 2 OF 45. ACCORDING TO SEC. R301.2.1.4.3
 FBC-RESIDENTIAL, 5TH EDITION (2014) THIS BUILDING LOOKS
 LIKE IS LOCATED IN EXPOSURE "C". THE DESIGN PRESSURE
 FOR ZONE #3 IS HIGHER THAN -90 PSF. THEREFORE, THIS
 ASSEMBLY CAN NOT BE USED. THE DESIGN PRESSURE FOR ZONE
 #3 IN EXPOSURE "C" IS +/- 95.7 PSF. PROVIDE ANOTHER
 ASSEMBLY THAT MEETS OR EXCEEDS THE DESIGN PRESSURE FOR
 ALL ROOF ZONES.
 NOTE: IF SELECTING ANOTHER ASSEMBLY THAT IS
 MECHANICALLY FASTENED AND THAT ALLOWS NAIL ENHANCING,
 THEN PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS AS
 REQUIRED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-06-27 Cont ID  
Sent By jgomez Date 2016-06-27 Time 15:30 Rev Time 0.00
Received By jgomez Date 2016-06-27 Time 15:30 Sent To  
Notes
2016-06-27 15:30:51RECEIVED E-MAIL FROM CONTRACTOR ADDRESSING COMMENTS.
 JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-06-24 Cont ID  
Sent By jgomez Date 2016-06-24 Time 16:46 Rev Time 0.00
Received By jgomez Date 2016-06-22 Time 10:55 Sent To  
Notes
2016-06-22 10:56:08JGOMEZ


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved