Plan Review Details - Permit 16061159
Plan Review Stops For Permit 16061159
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-08-12 Cont ID  
Sent By cthroop Date 2016-08-12 Time 13:33 Rev Time 0.00
Received By cthroop Date 2016-08-12 Time 13:33 Sent To  
Notes
2016-08-12 13:37:10BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER ? PX3169
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 ACTION: APPROVED
 DATE: 8/12/16
  
 1. THIS NON-ILLUMINATED SIGN WAS PART OF THE ORIGINAL
 SUBMITTAL. REVIEWD AND APPROVED. SENT APPLICANT TO
 ZONING FOR APPROVAL. SENT A COPY OF PLAN TO PROCESSING.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-07-15 Cont ID  
Sent By cthroop Date 2016-07-15 Time 08:41 Rev Time 0.00
Received By cthroop Date 2016-07-15 Time 08:41 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-06-28 Cont ID  
Sent By cthroop Date 2016-06-28 Time 09:24 Rev Time 0.00
Received By cthroop Date 2016-06-28 Time 09:24 Sent To  
Notes
2016-06-28 09:30:58BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER ? PX3169
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 ACTION: DENIED
 DATE: 6/28/16
  
 1. ONE DETAIL SHOWS 1/4" TAPCONS AND ANOTHER DETAIL
 SHOWS 3/8" LAG SCREWS. PROVIDE DETAIL OF EXISTING WALLS
 AND FASTENER SCHEDULE FOR EACH TYPE OF WALL.
 2. CANNOT READ NOTES ON PG. A2.0.
 3. COMPLY WITH ELECTRICAL AND ZONING COMMENTS.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES
 SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE
 TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE
 FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE
 DESIGN. (SEE ALSO SECTION 107.3.5).
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-07-14 Cont ID  
Sent By mvaldes Date 2016-07-14 Time 15:35 Rev Time 0.00
Received By mvaldes Date 2016-07-14 Time 15:35 Sent To B
Notes
2016-07-14 15:35:49ROUTED TO CHRIS THROOP

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-06-27 Cont ID  
Sent By mvaldes Date 2016-06-27 Time 09:03 Rev Time 0.00
Received By mvaldes Date 2016-06-27 Time 08:57 Sent To B
Notes
2016-06-27 09:04:51REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
  
 - FBC E SECTION C405.2.4 EXTERIOR LIGHTING CONTROLS.
 LIGHTING NOT DESIGNATED FOR DUSK-TO-DAWN OPERATION
 SHALL BE CONTROLLED BY EITHER A COMBINATION OF A
 PHOTOSENSOR AND A TIME SWITCH, OR AN ASTRONOMICAL TIME
 SWITCH. LIGHTING DESIGNATED FOR DUSK-TO-DAWN OPERATION
 SHALL BE CONTROLLED BY AN ASTRONOMICAL TIME SWITCH OR
 PHOTOSENSOR.
 ALL TIME SWITCHES SHALL BE CAPABLE OF RETAINING
 PROGRAMMING AND THE TIME SETTING DURING LOSS OF POWER
 FOR A PERIOD OF AT LEAST 10 HOURS. (ADD TO ELECTRICAL
 GENERAL NOTES)

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-08-12 Cont ID  
Sent By cthroop Date 2016-08-12 Time 13:33 Rev Time 0.00
Received By cthroop Date 2016-08-12 Time 13:33 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-07-15 Cont ID  
Sent By cthroop Date 2016-07-15 Time 08:41 Rev Time 0.00
Received By cthroop Date 2016-07-12 Time 13:53 Sent To  
Notes
2016-07-12 13:53:29RESUB ROUTED TO NJWIRA VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-06-28 Cont ID  
Sent By cthroop Date 2016-06-28 Time 09:23 Rev Time 0.00
Received By cthroop Date 2016-06-20 Time 10:14 Sent To  
Notes
2016-06-21 10:15:10ROUTED TO ZONING

Review Stop Z ZONING
Rev No 2 Status P Date 2016-07-14 Cont ID  
Sent By njwira Date 2016-07-14 Time 16:06 Rev Time 0.00
Received By njwira Date 2016-07-14 Time 16:06 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2016-06-22 Cont ID  
Sent By njwira Date 2016-06-22 Time 14:14 Rev Time 0.00
Received By njwira Date 2016-06-22 Time 14:14 Sent To E
Notes
2016-06-23 10:18:49ALL OTHER SIGNS ARE OK FACE SIGN IS TOO BIG FOR THE
 DISTRICT.
2016-06-22 14:15:106/22/16- FAILED
  
 1. IS NOT A PART OF THE APPROVAL IN ZBA3322


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved