Plan Review Details - Permit 16061105
Plan Review Stops For Permit 16061105
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-09-19 Cont ID  
Sent By jwitmer Date 2016-09-19 Time   Rev Time 0.00
Received By jwitmer Date 2016-09-19 Time 07:31 Sent To  
Notes
2016-09-19 08:02:53BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16061105
 ADD: 1100 S. FLAGLER DR.
 CONT: SUFFOLK CONSTRUCTION COMPANY
 TEL: 786-804-4407
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: MON. SEPT. 19/ 2016
 ACTION: BUILDING PROVISO
  
 1) THE ACCESSIBLE RAMPS INTO THE CONSTRUCTION TRAILERS
 IF MORE THAN 30 INCHES ABOVE GRADE WILL REQUIRE AN
 INTERMEDIATE LANDING (FBC-B 1010.5) OR CHANGE IN
 DIRECTION (FBC-B 1010.7.4).
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-06-27 Cont ID  
Sent By jwitmer Date 2016-06-27 Time 08:38 Rev Time 0.00
Received By jwitmer Date 2016-06-27 Time 07:32 Sent To  
Notes
2016-06-27 08:37:56BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16061105
 ADD: 1100 S. FLAGLER DR.
 CONT: SUFFOLK CONSTRUCTION COMPANY
 TEL: 786-804-4407
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. JUNE 27/ 2016
 ACTION: DENIED
  
 1) PLEASE PROVIDE A OVERALL SURVEY OF THIS LOT AND THE
 LOCATION OF THE 2 CONSTRUCTION TRAILERS ON THE LOT. IT
 IS CRITICAL OF THE LOCATION OF THESE CONSTRUCTION
 TRAILERS. THE STATE APPROVED PLANS INDICATE UNDER THE
 STRUCTURAL LIMITATIONS NOTE (F) THIS BUILDING IS NOT
 DESIGNED TO BE LOCATED IN A FLOOD HAZARD AREA. THIS LOT
 IS LOCATED IN AN "A-5" FLOOD ZONE WITH THE BASE FLOOD
 ELEVATION AT 7 FT. AND BY CITY ORDINANCE AN ADDITIONAL
 6 INCH FREE BOARD IS REQUIRED. 107.2.1.3 ADDITIONAL
 DATA. THE BUILDING OFFICIAL MAY REQUIRE DETAILS AND
 OTHER DATA NECESSARY TO DESCRIBE THE CONSTRUCTION OR
 INSTALLATION AND THE BASIS OF CALCULATIONS. ALL
 DRAWINGS, SPECIFICATIONS AND ACCOMPANYING DATA REQUIRED
 BY THE BUILDING OFFICIAL TO BE PREPARED BY AN ARCHITECT
 OR ENGINEER SHALL BE AFFIXED WITH THEIR OFFICIAL SEAL,
 SIGNATURE AND DATE AS STATE LAW REQUIRES.
  
 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-09-14 Cont ID  
Sent By vperez Date 2016-09-14 Time 08:24 Rev Time 0.00
Received By vperez Date 2016-09-14 Time 08:24 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-07-02 Cont ID  
Sent By vperez Date 2016-07-02 Time 07:30 Rev Time 0.00
Received By vperez Date 2016-07-02 Time 07:30 Sent To  
Notes
2016-07-02 07:33:25INITIAL ELECTRICAL PLAN REVIEW
  
 APPLICABLE CODES IN EFFECT:
 FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70- 2011 NEC
 COMMENTS:
  
 1. PLEASE ADDRESS FIRE AND STRUCTURAL COMMENTS FOR A
 FULL ELECTRICAL REVIEW.
 2. DELETE OR CROSS OUT ANY REFERENCE ON PLANS SHOWING
 OTHER THAN TRAILER HOOKUPS.
 3. COMMENTS MAY FOLLOW UPON RE-REVIEW. PLEASE FEEL FREE
 TO CONTACT ME SHOULD YOU HAVE ANY QUESTIONS REGARDING
 THIS PROJECT.
  
  
 VALENTINO PEREZ
 ELECTRICAL PLANS EXAMINER II
 561-805-6717
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2016-09-15 Cont ID  
Sent By pleduc Date 2016-09-15 Time   Rev Time 0.00
Received By pleduc Date 2016-09-15 Time 17:04 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2016-06-23 Cont ID  
Sent By pleduc Date 2016-06-23 Time   Rev Time 0.00
Received By pleduc Date 2016-06-23 Time 13:05 Sent To  
Notes
2016-06-23 14:14:06THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) FIVE (5) TRAILERS ARE INDICATED ON THE SITE PLAN,
 FOUR (4) WITH NO SEPARATION AND ONE (1) WITH 8'.
  
 PER NFPA 241
  
 4.2 TEMPORARY OFFICES AND SHEDS.
 4.2.1* SEPARATION DISTANCES BETWEEN BUILDINGS UNDER
 CONSTRUCTION AND CONSTRUCTION-RELATED STRUCTURES, SUCH
 AS TEMPORARY OFFICES, TRAILERS, SHEDS, AND OTHER
 FACILITIES FOR THE STORAGE OF TOOLS AND MATERIALS
 HAVING COMBUSTIBLE CONSTRUCTION OR
 CONTENTS, SHALL BE IN ACCORDANCE WITH TABLE 4.2.1.
  
 PER THE NOTE OF THE TABLE, (2) A 75 PERCENT REDUCTION
 IN SEPARATION DISTANCES SHALL BE PERMITTED TO BE
 APPLIED, PROVIDED AUTOMATIC SPRINKLER PROTECTION IS
 USED IN THE EXPOSING STRUCTURE.
  
 ADDITIONALLY, 4.2.2* DETACHMENT BETWEEN TEMPORARY
 STRUCTURES, ADEQUATE TEMPORARY FIXED FIRE PROTECTION
 SYSTEMS, AND PORTABLE EQUIPMENT SHALL BE PROVIDED AS
 REQUIRED BY THE AUTHORITY HAVING JURISDICTION.
  
 THE APPENDIX EXPLANATION ON THIS READS: A.4.2.2 WHERE
 LOCATED 9M(30 FT) OR MORE FROM THE STRUCTURE AND
 CONSTRUCTED OF COMBUSTIBLE MATERIALS, IT IS RECOMMENDED
 THAT TEMPORARY SUPPORT BUILDINGS BE DIVIDED INTO SMALL,
 DETACHED UNITS TO MINIMIZE FIRE LOSS. LARGE
 CONSTRUCTION SUPPORT COMPLEXES SHOULD BE PROTECTED WITH
 ADEQUATE FIRE PROTECTION (E.G., AUTOMATIC SPRINKLERS,
 YARD HYDRANTS, HOSE, AND EXTINGUISHERS) AS REQUIRED BY
 THE AUTHORITY HAVING JURISDICTION.
  
 A FIRE SPRINKLER SYSTEM SHALL BE PROVIDED TO THESE
 TEMPORAY TRAILERS PER THE ABOVE CODE REFERNCES. SHOULD
 THE DESIGN PROVE ADEQUATE A 13D SYSTEM CAN BE
 CONSIDERED.
  
 PROVIDE A LETTER OF INTENT TO INSTALL A FIRE SPRINKLER
 SYSTEM AND SHOP DRAWINGS THAT WILL BE ATTACHED TO THE
 SUBMITTAL AS PROVISO WILL BE SUFFICIENT TO PASS THIS
 PLAN.
  
 EMAIL TO THE ADDRESS BELOW.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-09-19 Cont ID  
Sent By jwitmer Date 2016-09-19 Time 08:03 Rev Time 0.00
Received By jwitmer Date 2016-09-07 Time 15:10 Sent To  
Notes
2016-09-07 15:10:19B25

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-09-02 Cont ID  
Sent By cpuell Date 2016-09-02 Time 13:45 Rev Time 0.00
Received By cpuell Date 2016-06-20 Time 09:30 Sent To  
Notes
2016-06-21 09:33:32B27

Review Stop Z ZONING
Rev No 1 Status P Date 2016-07-05 Cont ID  
Sent By jroach Date 2016-07-05 Time 15:41 Rev Time 0.00
Received By jroach Date 2016-07-05 Time 15:41 Sent To  
Notes
2016-07-05 15:41:59PROVISO
  
 ALL CONSTRUCTION TRAILERS SHALL BE REMOVED WITHIN SEVEN
 DAYS OF THE FINAL CONSTRUCTION INSPECTION BY THE CITY
 AND PRIOR TO THE ISSUANCE OF A CERTIFICATE OF
 OCCUPANCY.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH, PRINCIPAL
 PLANNER, AT [email protected] OR (561) 822-1448.
  