Plan Review Details - Permit 16061084
Plan Review Stops For Permit 16061084 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2016-10-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-10-11 |
Time |
10:46 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-10-11 |
Time |
10:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2016-08-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-08-08 |
Time |
11:30 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-08-08 |
Time |
11:25 |
Sent To |
|
|
Notes |
2016-08-08 11:30:23 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. PROVIDE A SIGNED AND SEALED LETTER FROM THE ENGINEER | | OF RECORD WHICH ACKNOWLEDGES THE CHANGE IN DESIGN | | (CABLE GROUPINGS ELIMINATED AT LEVELS 8, 9, 10) AND THE | | STATEMENT MADE REGARDING SUFFICIENT CAPACITY (REFER TO | | SHOP REVIEW BY CORDELL VAN NOSTRAND), FAC61G15. | | | | 2. CONTRACTOR IS RESPONSIBLE FOR PROVIDING THREE | | COLLATED COMPLETE SETS. THE FIRST SUBMITTAL WAS FOR | | POST TENSION DELEGATED ENGINEERING, FLOORS 8-20, AND | | INCLUDED CALCULATIONS. THE SECOND SUBMITTAL INCLUDES | | REVISED DRAWINGS MARKED 8-20, BUT ALSO INCLUDES A | | LETTER WHICH STATES THAT THREE CABLE GROUPINGS | | (109-111) WERE MISSED ON FLOORS 8-10. THE PREVIOUS | | SUBMITTAL WAS MARKED "VOID" AND THE CURRENT SUBMITTAL | | TITLE BLOCK STATES THAT THIS IS FOR FLOORS 8-20, AND | | CALCS FOR 109-11 INCLUDED. | | | | IT APPEARS THAT THE POST TENSION ENGINEERING AND CALCS | | SHOULD BE REVISED; ONE DRAWING AND CALCS FOR FLOORS | | 8-10, AND ANOTHER SEPARATE SUBMITTAL WHICH INCLUDES | | DRAWINGS AND CALCS FOR FLOORS 11-20. PLEASE REVISE | | ACCORDINGLY OR CONTACT ME TO DISCUSS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2016-07-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-07-11 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-07-11 |
Time |
14:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-06-23 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-06-23 |
Time |
13:23 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-06-23 |
Time |
13:23 |
Sent To |
|
|
Notes |
2016-06-23 13:25:48 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. THE ENGINEER'S REVIEW LETTER FOR THE DELEGATED | | ENGINEERING WAS ALTERED. PLEASE HAVE THE ENGINEER | | PREPARE A NEW LETTER AS THE CURRENT LETTER IS FOR THE | | 8TH FLOOR BUT THE ENGINEERING PROVIDED IS FOR 8TH | | THROUGH 20TH FLOORS. | | | | THE REVIEW LETTER FOR DELEGATED ENGINEERING IS TO BE | | CONSISTENT WITH THE DELEGATED ENGINEERING TO SHOW | | COMPLIANCE WITH FAC61G15-31.004. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2016-10-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-10-11 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-09-21 |
Time |
09:56 |
Sent To |
|
|
Notes |
2016-09-22 09:56:12 | RESUB ROUTED TO SHILL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-08-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-08-08 |
Time |
12:26 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-08-04 |
Time |
11:18 |
Sent To |
|
|
Notes |
2016-08-05 11:18:17 | SUBMITTAL ROUTED TO SHILL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-07-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-07-11 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-07-05 |
Time |
08:40 |
Sent To |
|
|
Notes |
2016-07-06 08:40:15 | RESUB ROUTED TO SHILL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-06-23 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-06-23 |
Time |
13:25 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-06-20 |
Time |
08:46 |
Sent To |
|
|
Notes |
2016-06-21 08:46:48 | SUBMITTAL ROUTED TO SHILL |
|
|
|