Plan Review Stops For Permit 16060963 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2016-08-17 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-08-17 |
Time |
14:40 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-08-17 |
Time |
14:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2016-08-02 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-08-02 |
Time |
12:14 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-08-02 |
Time |
12:14 |
Sent To |
|
|
Notes |
2016-08-02 12:16:06 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER ? PX3169 | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 3RD REVIEW | | ACTION: DENIED | | DATE: 8/2/16 | | | | 1. COMMENTS FROM 2ND REVIEW HAVE NOT BEEN ADDRESSED. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2016-07-25 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-07-25 |
Time |
09:22 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-07-25 |
Time |
09:22 |
Sent To |
P |
|
Notes |
2016-07-25 09:29:39 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER ? PX3169 | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 2ND REVIEW | | ACTION: DENIED | | DATE: 7/25/16 | | | | 1. EXISTING WINDOW TO BE REPLACED PER PROPOSED PLANS. | | 2. PROVIDE FRAMING DETAIL W/DEMENSIONS. | | 3. PROVIDE PRODUCT APPROVALS FOR NEW WINDOW. | | 4. PROVIDE DESIGN WIND LOADS FOR OPENING. | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH | | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES | | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE | | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE | | FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | DESIGN. (SEE ALSO SECTION 107.3.5). | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY | | FAC RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD. SPECIFICALLY, PROVIDE WINDOW | | SUBMITTALS. | | | | FBC 107.3.5.3 - PROVIDE WIND DESIGN LOADS/DESIGN | | PRESSURES PURSUANT TO FBC-R301.2. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-06-27 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-06-27 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-06-27 |
Time |
15:21 |
Sent To |
|
|
Notes |
2016-06-27 15:25:43 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER ? PX3169 | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | DATE: 6/27/16 | | ACTION: DENIED | | | | 1. THE PLANS SUBMITTED, WHICH ARE REQUIRED TO BE SIGNED | | BY THE DESIGNER, EXCEEDS THE SCOPE OF WORK INDICATED ON | | THE APPLICATION. | | 2. PROVIDE A SCOPE OF WORK INDICATING ALL WORK TO BE | | PERFORMED. | | 3. PROVIDE FLOOR PLAN WITH DEMENSIONS. | | 4. PLUMBING PERMIT MAY BE REQUIRED. | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH | | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES | | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE | | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE | | FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | DESIGN. (SEE ALSO SECTION 107.3.5). | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2016-07-27 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-07-27 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-07-27 |
Time |
16:16 |
Sent To |
P |
|
Notes |
2016-07-27 16:57:36 | ROUTED TO GEORGE JOHNSON ( PLUMBING ). |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2016-07-20 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-07-20 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-07-20 |
Time |
13:35 |
Sent To |
B |
|
Notes |
2016-07-20 14:32:11 | REVIEW 2014 5TH FBC ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | | | SAME COMMENTS AS PREVIOUSLY ASKED FOR : ( COPY & PASTE | | ) | | | | - FBC 107.2.1 PLEASE CLEARLY IDENTIFY THE SCOPE OF | | WORK. THE APPLICATION SHOWS "KITCHEN REMODEL", HOWEVER | | WORK IS BEING DONE IN THE BATHROOMS AS WELL ? HAVE THE | | PLANS SIGNED AND DATED BY THE DESIGNER RESPONSIBLE FOR | | THE DRAWING. | | | | - IF THE KITCHEN AND BATHROOMS ARE BEING REMODELED AN | | ELECTRICAL SUB PERMIT WILL BE REQUIRED. THE PLANS SHALL | | INCLUDE FBC R SECTIONS E3901.4 KITCHEN COUNTERTOP SPACE | | REQUIREMENTS & E3901.6 BATHROOM RECEPTACLE OUTLETS. | | | | - SHOW LOCATIONS OF OUTLETS ON THE FLOOR PLAN INCLUDE | | GFCI PROTECTION FOR E3902.1 BATHROOMS, E3902.6 | | KITCHENS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-06-27 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-06-27 |
Time |
09:46 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-06-27 |
Time |
09:29 |
Sent To |
B |
|
Notes |
2016-06-27 09:45:46 | REVIEW 2014 5TH FBC ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | | | | | - FBC 107.2.1 PLEASE CLEARLY IDENTIFY THE SCOPE OF | | WORK. THE APPLICATION SHOWS "KITCHEN REMODEL", HOWEVER | | WORK IS BEING DONE IN THE BATHROOMS AS WELL ? HAVE THE | | PLANS SIGNED AND DATED BY THE DESIGNER RESPONSIBLE FOR | | THE DRAWING. | | | | - IF THE KITCHEN AND BATHROOMS ARE BEING REMODELED AN | | ELECTRICAL SUB PERMIT WILL BE REQUIRED. THE PLANS SHALL | | INCLUDE FBC R SECTIONS E3901.4 KITCHEN COUNTERTOP SPACE | | REQUIREMENTS & E3901.6 BATHROOM RECEPTACLE OUTLETS. | | | | - SHOW LOCATIONS OF OUTLETS ON THE FLOOR PLAN INCLUDE | | GFCI PROTECTION FOR E3902.1 BATHROOMS, E3902.6 | | KITCHENS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2016-08-17 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-08-17 |
Time |
14:40 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-08-17 |
Time |
12:45 |
Sent To |
|
|
Notes |
2016-08-17 12:45:31 | CTHROOP'S DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-08-02 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-08-02 |
Time |
12:13 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-07-27 |
Time |
14:39 |
Sent To |
|
|
Notes |
2016-07-27 14:39:57 | RESUB ROUTED TO MVALDES |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-07-25 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-07-25 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-07-25 |
Time |
14:26 |
Sent To |
|
|
Notes |
2016-07-19 09:29:36 | RESUB ROUTED TO MVALDES |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-06-27 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-06-27 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-06-15 |
Time |
14:34 |
Sent To |
|
|
Notes |
2016-06-16 14:34:36 | BLDG MISC 1 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2016-08-01 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-08-01 |
Time |
14:12 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-08-01 |
Time |
14:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2016-07-25 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-07-25 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-07-25 |
Time |
14:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2016-06-24 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2016-06-24 |
Time |
16:40 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2016-06-24 |
Time |
16:40 |
Sent To |
E |
|
Notes |
2016-06-24 16:45:30 | 1ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL | | | | DENIED. I CANNOT DETERMINE THE SCOPE OF WORK FROM | | EITHER THE PLAN OR THE DESCRIPTION. PLEASE PROVIDE MORE | | DETAIL AND PLACE THE NAME AND SIGNATURE OF THE PERSON | | RESPONSIBLE FOR THE DESIGN ON THE DRAWINGS.. CLARIFY IF | | YOU ARE DOING PLUMBING WORK BEYOND REPLACING FIXTURES | | AND TILE. ARE YOU INSTALLING OR REPLACING A SHOWER PAN? | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS | | SHALL BE SUBMITTED WHEN APPROVED BY THE BUILDING | | OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL | | CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT | | LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED | | BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND | | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM | | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, | | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE | | TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC, | | AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE | | OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | SECTION 107.3.5). | | | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|