Plan Review Stops For Permit 16060624 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2017-04-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-04-05 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-04-05 |
Time |
16:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2017-03-30 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-03-30 |
Time |
16:29 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-03-30 |
Time |
10:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-07-01 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-07-01 |
Time |
11:29 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-07-01 |
Time |
11:29 |
Sent To |
M |
|
Notes |
2016-07-01 11:40:54 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER ? PX3169 | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | ACTION: DENIED | | DATE: DENIED | | | | 1. PALM BEACH COUNTY IMPACT FEES REQUIRED. | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. | | | | 2. ROOFING PERMIT REQUIRED. | | | | 3. PROVIDE ENERGY CALCULATIONS. | | FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO | | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. | | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | COMPLIANCE BY SECTION 405. | | | | R401.3 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD | | (MANDATORY). | | THE BUILDING OFFICIAL SHALL REQUIRE THAT AN ENERGY | | PERFORMANCE LEVEL (EPL) DISPLAY CARD BE COMPLETED AND | | CERTIFIED BY THE BUILDER TO BE ACCURATE AND CORRECT | | BEFORE FINAL APPROVAL OF THE BUILDING FOR OCCUPANCY. | | FLORIDA LAW [SECTION 553.9085, FLORIDA STATUTES)] | | REQUIRES THE EPL DISPLAY CARD TO BE INCLUDED AS AN | | ADDENDUM TO EACH SALES CONTRACT FOR BOTH PRESOLD AND | | NONPRESOLD RESIDENTIAL BUILDINGS. THE EPL DISPLAY CARD | | CONTAINS INFORMATION INDICATING THE ENERGY PERFORMANCE | | LEVEL AND EFFICIENCIES OF COMPONENTS INSTALLED IN A | | DWELLING UNIT. THE BUILDING OFFICIAL SHALL VERIFY THAT | | THE EPL DISPLAY CARD COMPLETED AND SIGNED BY THE | | BUILDER ACCURATELY REFLECTS THE PLANS AND | | SPECIFICATIONS SUBMITTED TO DEMONSTRATE CODE COMPLIANCE | | FOR THE BUILDING. A COPY OF THE EPL DISPLAY CARD CAN BE | | FOUND IN APPENDIX C. | | | | 4. PROVIDE WIND LOAD ENGINEERING FOR WINDOWS AND DOORS | | SUBJECT TO WIND LOAD. | | FBC 107.3.5.3 - PROVIDE WIND DESIGN LOADS/DESIGN | | PRESSURES PURSUANT TO FBC-R301.2. | | 1603.1.4 WIND DESIGN DATA. | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | STRUCTURE: | | 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, | | VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | 1609.3.1. | | 2. RISK CATEGORY. | | 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | THAN ONE WIND EXPOSURE IS UTILIZED. | | 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/ | | M2). | | | | 5. PROVIDE ENGINEERING ANALYSIS, SPECIFICATIONS AND | | DETAILS FOR PROPOSED HELICAL PILES. | | 1810.3.1.5 HELICAL PILES. | | HELICAL PILES SHALL BE DESIGNED AND MANUFACTURED IN | | ACCORDANCE WITH ACCEPTED ENGINEERING PRACTICE TO RESIST | | ALL STRESSES INDUCED BY INSTALLATION INTO THE GROUND | | AND SERVICE LOADS. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2017-04-14 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-04-14 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-04-14 |
Time |
15:44 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2017-03-07 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2017-03-07 |
Time |
14:00 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2017-03-07 |
Time |
14:00 |
Sent To |
|
|
Notes |
2017-03-07 14:00:42 | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | ELECTRICAL REVIEW COMMENTS. | | | | INDICATE THE LOCATION OF THE ELECTRICAL PANELS AND | | SUBPANELS. VERIFY THE REQUIRED WORKING CLEARANCES ARE | | MAINTAINED AT ALL ELECTRICAL PANELS. NEC 110.26, FBC R | | E3405.1 | | | | INDICATE THE LOCATION OF THE MAIN DISCONNECT. A MAIN | | ELECTRICAL DISCONNECT IS REQUIRED FOR THE SERVICE AT | | THE POINT WHERE THE BUILDING RECEIVES THE ELECTRICAL | | SUPPLY. UNPROTECTED SERVICE CONDUCTORS SHALL NOT ENTER | | THE BUILDING. FBC E3405, E3603 | | | | AN INTERSYSTEM BONDING SYSTEM IS REQUIRED AT THE | | SERVICE GROUNDING SYSTEM. NEC 250.94; FBC E3609 | | | | THE EXISTING 2ND FLOOR BEDROOM ALSO REQUIRES A SMOKE | | DETECTOR BOTH INSIDE AND OUTSIDE THE ROOM WITH A CARBON | | MONOXIDE DETECTOR WITHIN TEN FEET AS WELL. FBC R314, | | 315 | | | | ALL NEW CIRCUITS MUST BE PROTECTED WITH ARC FAULT | | BREAKERS. FBC E3902.12, NEC 210.12 | | | | | | | | ROBERT LECKY | | ELECTRICAL PLANS EXAMINER | | 561-805-6654(OFFICE) | | 561-373-3701(CELL) | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-06-30 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-06-30 |
Time |
16:07 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-06-30 |
Time |
13:38 |
Sent To |
|
|
Notes |
2016-06-30 16:10:07 | 1ST ELECTRICAL REVIEW NOTES | | REVIEWED FOR COMPLIANCE WITH: | | 5TH EDITION FBC 2014 & NFPA 70 2011 (NEC) | | | | 1. ACCORDING TO THE CITY OF WEST PALM BEACH AMENDMENTS | | TO THE FBC, CONSTRUCTION DOCUMENTS SUBMITTED FOR | | PERMITTING SHALL INCLUDE THE SPECIFIC CODE TO WHICH THE | | SYSTEM IS DESIGNED. SIMPLY STATING THE LATEST OR | | APPLICABLE IS PERMITTED. | | 2. ELECTRICAL NOTE 5 INDICATES SMOKE DETECTOR PLACEMENT | | OUTSIDE THE SLEEPING AREA. SUCH NOTE FAILS TO COMPLY | | WITH FBC-R 314.3. PER FBC 314.3 YOU SHALL HAVE A SMOKE | | DETECTOR ?INSIDE? THE SLEEPING AREA AND ALSO IN THE | | IMMEDIATE AREA OUTSIDE. PLEASE CORRECT THE NOTE AND | | DEVICE PLACEMENT ACCORDINGLY. | | 3. PER FBC 314.3.1 YOU SHALL INSTALL SMOKE DETECTORS | | THROUGHOUT THE RESIDENCE AS REQUIRED FOR NEW | | CONSTRUCTION. IF ALREADY DONE SO, DISREGARD THIS | | COMMENT. | | 4. PER FBC 315 IF THE RESIDENCE HAS AN ATTACHED GARAGE | | OR ANY FOSSIL FUEL BURNING APPLIANCE YOU SHALL INSTALL | | CARBON MONOXIDE DETECTORS AS INDICATED BY THIS SECTION. | | 5. THE WORD ?ROMEX? AS USED IN ELECTRICAL NOTE 13 IS | | INTENDED TO IDENTIFY A TYPE OF CABLE. ROMEX IS A BRAND | | NAME AND NOT A TYPE OF CABLE, REFER TO CABLE TYPES | | ?NM?, ?NMC? OR ?NMS?. | | 6. THE SAME APPLIES TO THE REFERENCE TO ?BX? IN | | ELECTRICAL NOTE 14. USE ?MC? CABLE INSTEAD. | | 7. FBC-RE4002.14/NEC 406.12 TAMPER-RESISTANT | | RECEPTACLES IN DWELLING UNITS. ALL NEWLY INSTALLED | | 125-VOLT, 15 AND 20 AMPERE RECEPTACLES SHALL BE LISTED | | TAMPER RESISTANT. | | 8. FBC-RE4001.15/NEC 404.2(C) WHERE SWITCHES | | CONTROLLING LIGHTING LOADS SUPPLIED BY A GROUNDED | | BRANCH CIRCUIT, THE GROUNDED BRANCH CIRCUIT CONDUCTOR | | FOR THE CONTROLLED LIGHTING CIRCUIT SHALL BE PROVIDED | | AT THE SWITCH. | | 9. PER NEC 215.5 A SITE SPECIFIC RISER DIAGRAM AND LOAD | | CALCS ARE REQUIRED. | | 10. FBC-RE3706.2/NEC 408.4 A PANEL CIRCUIT DIRECTORY IS | | REQUIRED FOR ALL PANELS. | | 11. FBC-RE3901.7/NEC 210.52(E)(3) BALCONIES, DECKS, AND | | PORCHES THAT ARE ACCESSIBLE FROM INSIDE THE DWELLING | | UNIT SHALL HAVE AT LEAST ONE RECEPTACLE OUTLET | | INSTALLED WITHIN THE PERIMETER OF THE BALCONY, DECK, OR | | PORCH. THE RECEPTACLE SHALL NOT BE LOCATED MORE THAN | | 2.0 M (61?2 FT.) ABOVE THE BALCONY, DECK, OR PORCH | | SURFACE. | | 12. FBC-RE3903.4/NEC 210.70(A)(3) STORAGE OR EQUIPMENT | | SPACES. AT LEAST ONE LIGHTING OUTLET CONTAINING A | | SWITCH OR CONTROLLED BY A WALL SWITCH SHALL BE | | INSTALLED WHERE THESE SPACES ARE USED FOR STORAGE OR | | CONTAIN EQUIPMENT REQUIRING SERVICING. THE LIGHTING | | OUTLET SHALL BE PROVIDED AT OR NEAR THE EQUIPMENT | | REQUIRING SERVICING. | | 13. IN ADDITION TO THE ABOVE, PROVIDE EITHER ON A SITE | | PLAN OR MARK THE FLOOR PLAN WITH THE LOCATION OF THE | | ELECTRIC METER AND PANELS TO ASCERTAIN COMPLIANCE WITH | | FBC-RE3601.6.2/NEC 230.70(A)(1). THE SERVICE DISCONNECT | | SHALL BE LOCATED IN A READILY ACCESSIBLE LOCATION | | OUTSIDE OF THE BLDG. OR INSIDE AT THE NEAREST POINT OF | | ENTRY OF THE SERVICE CONDUCTORS. | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER | | (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER | | WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | GREATLY APPRECIATED. | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | | | THANK YOU, | | MIKE ALBARRAN | | ELECTRICAL PLANS EXAMINER | | PH: 561-805-6746 | | EMAIL: [email protected] | | | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2017-03-14 |
|
|
Cont ID |
|
Sent By |
destabro |
Date |
2017-03-14 |
Time |
14:16 |
Rev Time |
0.00 |
Received By |
destabro |
Date |
2017-03-14 |
Time |
14:16 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2016-06-14 |
|
|
Cont ID |
|
Sent By |
destabro |
Date |
2016-06-14 |
Time |
09:30 |
Rev Time |
0.00 |
Received By |
destabro |
Date |
2016-06-14 |
Time |
09:30 |
Sent To |
|
|
Notes |
2016-06-14 09:31:36 | 6/14/16 - HPB APPROVED AT APRIL 26, 2016 MEETING (HPB | | CASE 16-20). CURRENT PROPOSED DESIGN MEETS CONDITIONS | | FOR APPROVAL. DLE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2017-05-09 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-05-09 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-05-04 |
Time |
14:57 |
Sent To |
|
|
Notes |
2017-05-08 14:57:58 | HMOSER'S DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2017-04-11 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-04-11 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-04-10 |
Time |
13:53 |
Sent To |
|
|
Notes |
2017-04-11 13:53:22 | IMPACT FEES ROUTED TO CTHROOP |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-04-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-04-05 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-04-04 |
Time |
15:23 |
Sent To |
|
|
Notes |
2017-04-05 15:23:28 | RESUB ROUTED TO CTHROOP |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-03-30 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-03-30 |
Time |
16:29 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-03-01 |
Time |
11:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-07-07 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2016-07-07 |
Time |
10:17 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2016-06-09 |
Time |
13:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2017-04-11 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-04-11 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-04-11 |
Time |
14:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2016-07-01 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-07-01 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-07-01 |
Time |
11:19 |
Sent To |
|
|
Notes |
2016-07-01 11:20:40 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER ? PX3169 | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | ACTION: DENIED | | DATE: DENIED | | | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. | | | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2017-05-09 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-05-09 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-05-09 |
Time |
13:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2017-04-17 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-04-17 |
Time |
09:35 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-04-17 |
Time |
09:35 |
Sent To |
|
|
Notes |
2017-04-17 09:37:16 | PLAN DENIED | | NO MECHANICAL PLAN SUBMITTED HM. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2017-03-27 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-03-27 |
Time |
13:31 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-03-27 |
Time |
13:11 |
Sent To |
|
|
Notes |
2017-03-27 13:31:30 | PLAN DENIED | | PLEASE PROVIDE A COMPLETE SET OF PLANS SHOWING | | EQUIPMENT LOCATION, EQUIPMENT SCHEDULE, DUCT WORK | | LOCATION | | AND SIZING, AND CFM ON SUPPLY GRILLS. | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-07-06 |
|
|
Cont ID |
|
Sent By |
jvalido |
Date |
2016-07-06 |
Time |
17:41 |
Rev Time |
0.00 |
Received By |
jvalido |
Date |
2016-07-06 |
Time |
17:19 |
Sent To |
|
|
Notes |
2016-07-06 17:40:46 | CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA | | BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION | | | | 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1 | | INFORMATION ON CONSTRUCTION DOCUMENTS | | | | (1) PROVIDE MECHANICAL PLANS. | | | | FLORIDA ENERGY CODE FBC 2014 | | | | (2) PROVIDE HEAT LOADS AND ENERGY CALCULATIONS | | | | JORGE VALIDO | | WPB MECHANICAL INSPECTOR/PLANS EXAMINER | | [email protected] | | 561-805-6716 | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2017-03-16 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-03-16 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-03-16 |
Time |
11:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2016-06-22 |
|
|
Cont ID |
|
Sent By |
gearl |
Date |
2016-06-22 |
Time |
11:02 |
Rev Time |
0.00 |
Received By |
gearl |
Date |
2016-06-22 |
Time |
11:02 |
Sent To |
|
|
Notes |
2016-06-22 11:01:57 | NEED TO SHOW CLEAN OUT AT BASE OF STACK ON DRAWING | | NEED TO SHOW VENT BETWEEN TUB AND W/C |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2017-03-30 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-03-30 |
Time |
16:16 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-03-30 |
Time |
10:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2016-07-01 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-07-01 |
Time |
11:20 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-07-01 |
Time |
11:20 |
Sent To |
|
|
Notes |
2016-07-01 11:29:07 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER ? PX3169 | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | ACTION: DENIED | | DATE: DENIED | | | | 1. PROVIDE WIND LOAD ENGINEERING FOR NEW ROOF. | | FBC 107.3.5.3 - PROVIDE WIND DESIGN LOADS/DESIGN | | PRESSURES PURSUANT TO FBC-R301.2. | | 1603.1.4 WIND DESIGN DATA. | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | STRUCTURE: | | 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, | | VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | 1609.3.1. | | 2. RISK CATEGORY. | | 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | THAN ONE WIND EXPOSURE IS UTILIZED. | | 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/ | | M2). | | | | 2. PROVIDE SHEATHING FASTENER SPECIFICATIONS FOR EACH | | ZONE OF ROOF BASED ON WIND LOADS. | | | | 3. PROVIDE PRODUCT APPROVALS FOR FLAT ROOF SYSTEM. | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY | | FAC RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD. SPECIFICALLY, PROVIDE ROOFING | | SUBMITTALS. | | | | 4. ROOFING PERMIT REQUIRED. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2016-06-14 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2016-06-14 |
Time |
09:06 |
Rev Time |
0.00 |
Received By |
awooten |
Date |
2016-06-14 |
Time |
09:06 |
Sent To |
|
|
Notes |
|
|