Plan Review Details - Permit 16060624
Plan Review Stops For Permit 16060624
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2017-04-05 Cont ID  
Sent By cthroop Date 2017-04-05 Time 16:36 Rev Time 0.00
Received By cthroop Date 2017-04-05 Time 16:29 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-03-30 Cont ID  
Sent By cthroop Date 2017-03-30 Time 16:29 Rev Time 0.00
Received By cthroop Date 2017-03-30 Time 10:14 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-07-01 Cont ID  
Sent By cthroop Date 2016-07-01 Time 11:29 Rev Time 0.00
Received By cthroop Date 2016-07-01 Time 11:29 Sent To M
Notes
2016-07-01 11:40:54BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER ? PX3169
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 ACTION: DENIED
 DATE: DENIED
  
 1. PALM BEACH COUNTY IMPACT FEES REQUIRED.
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
 2. ROOFING PERMIT REQUIRED.
  
 3. PROVIDE ENERGY CALCULATIONS.
 FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402
 SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO
 DEMONSTRATE CODE COMPLIANCE BY THIS METHOD.
  
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 R401.3 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
 (MANDATORY).
 THE BUILDING OFFICIAL SHALL REQUIRE THAT AN ENERGY
 PERFORMANCE LEVEL (EPL) DISPLAY CARD BE COMPLETED AND
 CERTIFIED BY THE BUILDER TO BE ACCURATE AND CORRECT
 BEFORE FINAL APPROVAL OF THE BUILDING FOR OCCUPANCY.
 FLORIDA LAW [SECTION 553.9085, FLORIDA STATUTES)]
 REQUIRES THE EPL DISPLAY CARD TO BE INCLUDED AS AN
 ADDENDUM TO EACH SALES CONTRACT FOR BOTH PRESOLD AND
 NONPRESOLD RESIDENTIAL BUILDINGS. THE EPL DISPLAY CARD
 CONTAINS INFORMATION INDICATING THE ENERGY PERFORMANCE
 LEVEL AND EFFICIENCIES OF COMPONENTS INSTALLED IN A
 DWELLING UNIT. THE BUILDING OFFICIAL SHALL VERIFY THAT
 THE EPL DISPLAY CARD COMPLETED AND SIGNED BY THE
 BUILDER ACCURATELY REFLECTS THE PLANS AND
 SPECIFICATIONS SUBMITTED TO DEMONSTRATE CODE COMPLIANCE
 FOR THE BUILDING. A COPY OF THE EPL DISPLAY CARD CAN BE
 FOUND IN APPENDIX C.
  
 4. PROVIDE WIND LOAD ENGINEERING FOR WINDOWS AND DOORS
 SUBJECT TO WIND LOAD.
 FBC 107.3.5.3 - PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-R301.2.
 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED,
 VASD, AS DETERMINED IN ACCORDANCE WITH SECTION
 1609.3.1.
 2. RISK CATEGORY.
 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED.
 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL
 RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/
 M2).
  
 5. PROVIDE ENGINEERING ANALYSIS, SPECIFICATIONS AND
 DETAILS FOR PROPOSED HELICAL PILES.
 1810.3.1.5 HELICAL PILES.
 HELICAL PILES SHALL BE DESIGNED AND MANUFACTURED IN
 ACCORDANCE WITH ACCEPTED ENGINEERING PRACTICE TO RESIST
 ALL STRESSES INDUCED BY INSTALLATION INTO THE GROUND
 AND SERVICE LOADS.
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2017-04-14 Cont ID  
Sent By jleahy Date 2017-04-14 Time 15:44 Rev Time 0.00
Received By jleahy Date 2017-04-14 Time 15:44 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2017-03-07 Cont ID  
Sent By rlecky Date 2017-03-07 Time 14:00 Rev Time 0.00
Received By rlecky Date 2017-03-07 Time 14:00 Sent To  
Notes
2017-03-07 14:00:42PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING
 ELECTRICAL REVIEW COMMENTS.
  
 INDICATE THE LOCATION OF THE ELECTRICAL PANELS AND
 SUBPANELS. VERIFY THE REQUIRED WORKING CLEARANCES ARE
 MAINTAINED AT ALL ELECTRICAL PANELS. NEC 110.26, FBC R
 E3405.1
  
 INDICATE THE LOCATION OF THE MAIN DISCONNECT. A MAIN
 ELECTRICAL DISCONNECT IS REQUIRED FOR THE SERVICE AT
 THE POINT WHERE THE BUILDING RECEIVES THE ELECTRICAL
 SUPPLY. UNPROTECTED SERVICE CONDUCTORS SHALL NOT ENTER
 THE BUILDING. FBC E3405, E3603
  
 AN INTERSYSTEM BONDING SYSTEM IS REQUIRED AT THE
 SERVICE GROUNDING SYSTEM. NEC 250.94; FBC E3609
  
 THE EXISTING 2ND FLOOR BEDROOM ALSO REQUIRES A SMOKE
 DETECTOR BOTH INSIDE AND OUTSIDE THE ROOM WITH A CARBON
 MONOXIDE DETECTOR WITHIN TEN FEET AS WELL. FBC R314,
 315
  
 ALL NEW CIRCUITS MUST BE PROTECTED WITH ARC FAULT
 BREAKERS. FBC E3902.12, NEC 210.12
  
  
  
 ROBERT LECKY
 ELECTRICAL PLANS EXAMINER
 561-805-6654(OFFICE)
 561-373-3701(CELL)
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-06-30 Cont ID  
Sent By albarran Date 2016-06-30 Time 16:07 Rev Time 0.00
Received By albarran Date 2016-06-30 Time 13:38 Sent To  
Notes
2016-06-30 16:10:071ST ELECTRICAL REVIEW NOTES
 REVIEWED FOR COMPLIANCE WITH:
 5TH EDITION FBC 2014 & NFPA 70 2011 (NEC)
  
 1. ACCORDING TO THE CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC, CONSTRUCTION DOCUMENTS SUBMITTED FOR
 PERMITTING SHALL INCLUDE THE SPECIFIC CODE TO WHICH THE
 SYSTEM IS DESIGNED. SIMPLY STATING THE LATEST OR
 APPLICABLE IS PERMITTED.
 2. ELECTRICAL NOTE 5 INDICATES SMOKE DETECTOR PLACEMENT
 OUTSIDE THE SLEEPING AREA. SUCH NOTE FAILS TO COMPLY
 WITH FBC-R 314.3. PER FBC 314.3 YOU SHALL HAVE A SMOKE
 DETECTOR ?INSIDE? THE SLEEPING AREA AND ALSO IN THE
 IMMEDIATE AREA OUTSIDE. PLEASE CORRECT THE NOTE AND
 DEVICE PLACEMENT ACCORDINGLY.
 3. PER FBC 314.3.1 YOU SHALL INSTALL SMOKE DETECTORS
 THROUGHOUT THE RESIDENCE AS REQUIRED FOR NEW
 CONSTRUCTION. IF ALREADY DONE SO, DISREGARD THIS
 COMMENT.
 4. PER FBC 315 IF THE RESIDENCE HAS AN ATTACHED GARAGE
 OR ANY FOSSIL FUEL BURNING APPLIANCE YOU SHALL INSTALL
 CARBON MONOXIDE DETECTORS AS INDICATED BY THIS SECTION.
 5. THE WORD ?ROMEX? AS USED IN ELECTRICAL NOTE 13 IS
 INTENDED TO IDENTIFY A TYPE OF CABLE. ROMEX IS A BRAND
 NAME AND NOT A TYPE OF CABLE, REFER TO CABLE TYPES
 ?NM?, ?NMC? OR ?NMS?.
 6. THE SAME APPLIES TO THE REFERENCE TO ?BX? IN
 ELECTRICAL NOTE 14. USE ?MC? CABLE INSTEAD.
 7. FBC-RE4002.14/NEC 406.12 TAMPER-RESISTANT
 RECEPTACLES IN DWELLING UNITS. ALL NEWLY INSTALLED
 125-VOLT, 15 AND 20 AMPERE RECEPTACLES SHALL BE LISTED
 TAMPER RESISTANT.
 8. FBC-RE4001.15/NEC 404.2(C) WHERE SWITCHES
 CONTROLLING LIGHTING LOADS SUPPLIED BY A GROUNDED
 BRANCH CIRCUIT, THE GROUNDED BRANCH CIRCUIT CONDUCTOR
 FOR THE CONTROLLED LIGHTING CIRCUIT SHALL BE PROVIDED
 AT THE SWITCH.
 9. PER NEC 215.5 A SITE SPECIFIC RISER DIAGRAM AND LOAD
 CALCS ARE REQUIRED.
 10. FBC-RE3706.2/NEC 408.4 A PANEL CIRCUIT DIRECTORY IS
 REQUIRED FOR ALL PANELS.
 11. FBC-RE3901.7/NEC 210.52(E)(3) BALCONIES, DECKS, AND
 PORCHES THAT ARE ACCESSIBLE FROM INSIDE THE DWELLING
 UNIT SHALL HAVE AT LEAST ONE RECEPTACLE OUTLET
 INSTALLED WITHIN THE PERIMETER OF THE BALCONY, DECK, OR
 PORCH. THE RECEPTACLE SHALL NOT BE LOCATED MORE THAN
 2.0 M (61?2 FT.) ABOVE THE BALCONY, DECK, OR PORCH
 SURFACE.
 12. FBC-RE3903.4/NEC 210.70(A)(3) STORAGE OR EQUIPMENT
 SPACES. AT LEAST ONE LIGHTING OUTLET CONTAINING A
 SWITCH OR CONTROLLED BY A WALL SWITCH SHALL BE
 INSTALLED WHERE THESE SPACES ARE USED FOR STORAGE OR
 CONTAIN EQUIPMENT REQUIRING SERVICING. THE LIGHTING
 OUTLET SHALL BE PROVIDED AT OR NEAR THE EQUIPMENT
 REQUIRING SERVICING.
 13. IN ADDITION TO THE ABOVE, PROVIDE EITHER ON A SITE
 PLAN OR MARK THE FLOOR PLAN WITH THE LOCATION OF THE
 ELECTRIC METER AND PANELS TO ASCERTAIN COMPLIANCE WITH
 FBC-RE3601.6.2/NEC 230.70(A)(1). THE SERVICE DISCONNECT
 SHALL BE LOCATED IN A READILY ACCESSIBLE LOCATION
 OUTSIDE OF THE BLDG. OR INSIDE AT THE NEAREST POINT OF
 ENTRY OF THE SERVICE CONDUCTORS.
  
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER
 (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER
 WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD
 CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID
 AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR
 COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE
 GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 THANK YOU,
 MIKE ALBARRAN
 ELECTRICAL PLANS EXAMINER
 PH: 561-805-6746
 EMAIL: [email protected]
  
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2017-03-14 Cont ID  
Sent By destabro Date 2017-03-14 Time 14:16 Rev Time 0.00
Received By destabro Date 2017-03-14 Time 14:16 Sent To B
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2016-06-14 Cont ID  
Sent By destabro Date 2016-06-14 Time 09:30 Rev Time 0.00
Received By destabro Date 2016-06-14 Time 09:30 Sent To  
Notes
2016-06-14 09:31:366/14/16 - HPB APPROVED AT APRIL 26, 2016 MEETING (HPB
 CASE 16-20). CURRENT PROPOSED DESIGN MEETS CONDITIONS
 FOR APPROVAL. DLE

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2017-05-09 Cont ID  
Sent By hmoser Date 2017-05-09 Time 14:43 Rev Time 0.00
Received By hmoser Date 2017-05-04 Time 14:57 Sent To  
Notes
2017-05-08 14:57:58HMOSER'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2017-04-11 Cont ID  
Sent By cthroop Date 2017-04-11 Time 14:27 Rev Time 0.00
Received By cthroop Date 2017-04-10 Time 13:53 Sent To  
Notes
2017-04-11 13:53:22IMPACT FEES ROUTED TO CTHROOP

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-04-05 Cont ID  
Sent By cthroop Date 2017-04-05 Time 16:36 Rev Time 0.00
Received By cthroop Date 2017-04-04 Time 15:23 Sent To  
Notes
2017-04-05 15:23:28RESUB ROUTED TO CTHROOP

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-03-30 Cont ID  
Sent By cthroop Date 2017-03-30 Time 16:29 Rev Time 0.00
Received By cthroop Date 2017-03-01 Time 11:45 Sent To  
Notes
2017-03-06 11:46:18R22

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-07-07 Cont ID  
Sent By cpuell Date 2016-07-07 Time 10:17 Rev Time 0.00
Received By cpuell Date 2016-06-09 Time 13:43 Sent To  
Notes
2016-06-09 13:43:48R20

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2017-04-11 Cont ID  
Sent By cthroop Date 2017-04-11 Time 14:27 Rev Time 0.00
Received By cthroop Date 2017-04-11 Time 14:27 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2016-07-01 Cont ID  
Sent By cthroop Date 2016-07-01 Time 11:19 Rev Time 0.00
Received By cthroop Date 2016-07-01 Time 11:19 Sent To  
Notes
2016-07-01 11:20:40BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER ? PX3169
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 ACTION: DENIED
 DATE: DENIED
  
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2017-05-09 Cont ID  
Sent By hmoser Date 2017-05-09 Time 14:42 Rev Time 0.00
Received By hmoser Date 2017-05-09 Time 13:06 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2017-04-17 Cont ID  
Sent By hmoser Date 2017-04-17 Time 09:35 Rev Time 0.00
Received By hmoser Date 2017-04-17 Time 09:35 Sent To  
Notes
2017-04-17 09:37:16PLAN DENIED
 NO MECHANICAL PLAN SUBMITTED HM.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2017-03-27 Cont ID  
Sent By hmoser Date 2017-03-27 Time 13:31 Rev Time 0.00
Received By hmoser Date 2017-03-27 Time 13:11 Sent To  
Notes
2017-03-27 13:31:30PLAN DENIED
 PLEASE PROVIDE A COMPLETE SET OF PLANS SHOWING
 EQUIPMENT LOCATION, EQUIPMENT SCHEDULE, DUCT WORK
 LOCATION
 AND SIZING, AND CFM ON SUPPLY GRILLS.
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-07-06 Cont ID  
Sent By jvalido Date 2016-07-06 Time 17:41 Rev Time 0.00
Received By jvalido Date 2016-07-06 Time 17:19 Sent To  
Notes
2016-07-06 17:40:46CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA
 BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION
  
 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS
  
 (1) PROVIDE MECHANICAL PLANS.
  
 FLORIDA ENERGY CODE FBC 2014
  
 (2) PROVIDE HEAT LOADS AND ENERGY CALCULATIONS
  
 JORGE VALIDO
 WPB MECHANICAL INSPECTOR/PLANS EXAMINER
 [email protected]
 561-805-6716
  
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-03-16 Cont ID  
Sent By gjohnson Date 2017-03-16 Time 13:57 Rev Time 0.00
Received By gjohnson Date 2017-03-16 Time 11:43 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-06-22 Cont ID  
Sent By gearl Date 2016-06-22 Time 11:02 Rev Time 0.00
Received By gearl Date 2016-06-22 Time 11:02 Sent To  
Notes
2016-06-22 11:01:57NEED TO SHOW CLEAN OUT AT BASE OF STACK ON DRAWING
 NEED TO SHOW VENT BETWEEN TUB AND W/C

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2017-03-30 Cont ID  
Sent By cthroop Date 2017-03-30 Time 16:16 Rev Time 0.00
Received By cthroop Date 2017-03-30 Time 10:14 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2016-07-01 Cont ID  
Sent By cthroop Date 2016-07-01 Time 11:20 Rev Time 0.00
Received By cthroop Date 2016-07-01 Time 11:20 Sent To  
Notes
2016-07-01 11:29:07BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER ? PX3169
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 ACTION: DENIED
 DATE: DENIED
  
 1. PROVIDE WIND LOAD ENGINEERING FOR NEW ROOF.
 FBC 107.3.5.3 - PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-R301.2.
 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED,
 VASD, AS DETERMINED IN ACCORDANCE WITH SECTION
 1609.3.1.
 2. RISK CATEGORY.
 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED.
 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL
 RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/
 M2).
  
 2. PROVIDE SHEATHING FASTENER SPECIFICATIONS FOR EACH
 ZONE OF ROOF BASED ON WIND LOADS.
  
 3. PROVIDE PRODUCT APPROVALS FOR FLAT ROOF SYSTEM.
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY
 FAC RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD. SPECIFICALLY, PROVIDE ROOFING
 SUBMITTALS.
  
 4. ROOFING PERMIT REQUIRED.
  

Review Stop Z ZONING
Rev No 1 Status P Date 2016-06-14 Cont ID  
Sent By awooten Date 2016-06-14 Time 09:06 Rev Time 0.00
Received By awooten Date 2016-06-14 Time 09:06 Sent To  
Notes
***NONE***