Plan Review Details - Permit 16060600
Plan Review Stops For Permit 16060600
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2016-06-30 Cont ID  
Sent By skennedy Date 2016-06-30 Time 10:11 Rev Time 0.00
Received By skennedy Date 2016-06-30 Time 10:11 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-07-07 Cont ID  
Sent By skennedy Date 2016-07-07 Time 16:05 Rev Time 0.00
Received By skennedy Date 2016-07-07 Time 16:05 Sent To  
Notes
2016-07-07 16:07:051ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL
  
 APPROVED WITH CONDITION THAT A DISCONNECT BE PROVIDED
 AT WH PER FBC-RE 4101.5
  
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-06-30 Cont ID  
Sent By   Date 2016-06-28 Time 15:49 Rev Time 0.00
Received By albarran Date 2016-06-28 Time 13:19 Sent To  
Notes
2016-06-28 15:50:401ST ELECTRICAL REVIEW NOTES
 REVIEWED FOR COMPLIANCE WITH:
 5TH EDITION FBC 2014 & NFPA 70 2011 (NEC)
  
 1. THE APPLICABLE CODE IS THE 5TH EDITION OF THE 2014
 FBC-R. CORRECT NOTE ACCORDINGLY.
 2. FBC-RE4101.5/NEC 422.31(B) YOU SHALL PROVIDE A
 DISCONNECT FOR THE WATER HEATER OR MAKE A NOTE AS TO
 THE MODE OF COMPLIANCE.
 3. FBC-RE3901.7/NEC 210.52(E)(3) REQUIRES THAT THERE BE
 AN OUTLET WITHIN THE PERIMETER OF THE BALCONY.
 4. FBC-RE3903.4/NEC 210.70(3) REQUIRES THAT THERE BE AT
 LEAST ONE SWITCH FOR THE ATTIC LIGHT AT THE POINT OF
 ENTRY, (IN THE INTEREST OF ENERGY CONSERVATION MAY I
 SUGGEST THE SWITCH HAVE A PILOT LIGHT AND BE OUTSIDE
 THE ATTIC ON A WALL VISIBLE TO THE OCCUPANTS). THIS
 DOES AWAY WITH THE PULL CHAIN AS THE SINGLE SWITCH.
 FURTHERMORE, THE ACTUAL LUMINAIRE SHALL CLOSE TO THE
 EQUIPMENT.
 5. FBC-RE4003.2/NEC 410.11 REQUIRES THAT LUMINAIRES
 NEAR COMBUSTIBLE MATERIALS HAVE A GUARD AROUND THE LAMP
 TO PREVENT CONTACT GREATER THAN 90 DEGREES. THIS
 ELIMINATES THE EXPOSED LAMP PULL CHAIN FIXTURE IN THE
 ATTIC.
  
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER
 (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER
 WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD
 CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID
 AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR
 COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE
 GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 THANK YOU,
 MIKE ALBARRAN
 ELECTRICAL PLANS EXAMINER
 PH: 561-805-6746
 EMAIL: [email protected]
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2016-07-08 Cont ID  
Sent By fmittner Date 2016-07-08 Time 15:06 Rev Time 0.00
Received By fmittner Date 2016-07-08 Time 15:06 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-07-08 Cont ID  
Sent By cpuell Date 2016-07-08 Time 15:14 Rev Time 0.00
Received By cpuell Date 2016-06-23 Time 15:28 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status P Date 2016-06-30 Cont ID  
Sent By skennedy Date 2016-06-30 Time 10:10 Rev Time 0.00
Received By skennedy Date 2016-06-30 Time 10:10 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2016-06-30 Cont ID  
Sent By skennedy Date 2016-06-30 Time 10:11 Rev Time 0.00
Received By skennedy Date 2016-06-30 Time 10:11 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-06-30 Cont ID  
Sent By skennedy Date 2016-06-30 Time 10:11 Rev Time 0.00
Received By skennedy Date 2016-06-30 Time 10:11 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2016-06-30 Cont ID  
Sent By skennedy Date 2016-06-30 Time 10:11 Rev Time 0.00
Received By skennedy Date 2016-06-30 Time 10:11 Sent To  
Notes
2016-06-30 10:11:54ROOFING

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2016-06-30 Cont ID  
Sent By skennedy Date 2016-06-30 Time 10:12 Rev Time 0.00
Received By skennedy Date 2016-06-30 Time 10:12 Sent To  
Notes
2016-07-15 15:45:34ALL SIGNATURES RECEIVED.
2016-06-30 10:21:511ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL
  
 PLEASE PROVIDE AN ORIGINAL SEALD SIGNATURE BY ANTHONY
 TOMBO III, P.E. ON TRUSS DRAWINGS. YOU MAY ELECT TO DO
 SO PRIOR TO ERECTING TRUSSES.
 PLEASE PROVIDE AN ORIGINAL SEALD SIGNATURE BY JULIE
 KELLER, P.E. ON SOIL REPORT. YOU MAY ELECT TO DO SO
 PRIOR TO SLAB INSPECTION..
  
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  
2016-06-21 10:49:09RECEIVED ORIGINAL SIGNED AND SEALED SURVEY - WITH APP
 IN LIBRARY. LEM

Review Stop Z ZONING
Rev No 1 Status P Date 2016-07-08 Cont ID  
Sent By frmittne Date 2016-07-08 Time 15:06 Rev Time 0.00
Received By fmittner Date 2016-07-08 Time 15:06 Sent To  
Notes
***NONE***