Plan Review Stops For Permit 16060576 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2016-08-10 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-08-10 |
Time |
15:41 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-08-10 |
Time |
15:41 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2016-07-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-07-13 |
Time |
11:42 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-07-13 |
Time |
11:42 |
Sent To |
E |
|
Notes |
2016-07-13 11:55:25 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER ? PX3169 | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 2ND REVIEW | | ACTION: DENIED | | DATE: 7/13/16 | | | | 1. PLAN TO REFERENCE CURRENT GOVERNING CODES. | | 2. PLAN TO BE REVIEWED, SIGNED AND SEALED BY DESIGN | | PROFESSIONAL. | | 3. SUBMITTAL TO BE IN DUPLICATE. | | 4. REF. PLAN PG. 2 OF 10. INSTALLATION DETAIL REQUIRES | | HILTI WEDGE ANCHORS. PROVIDE DETAIL OF EXISTING WALL | | TYPE WITH FASTENER SIZE AND LENGTH FOR WALL TYPE. | | 5. REF. PLAN PG. 3 OF 10. INSTALLATION COMMENTS REQUIRE | | "STUD MOUNT FLUSH TO FACIA". NO DETAIL PROVIDED. | | PROVIDE DETAIL OF EXISTING WALL TYPE WITH FASTENER SIZE | | AND LENGTH FOR WALL TYPE. | | 6. REF. PLAN PG. 4 OF 10. INSTALLATION COMMENTS REQUIRE | | "MECHANICALLY FASTEN WITH APPROPRIATE HARDWARE". NO | | DETAIL PROVIDED. PROVIDE DETAIL OF EXISTING WALL TYPE | | WITH FASTENER SIZE AND LENGTH FOR WALL TYPE. | | 7. REF. PLAN PG. 5 OF 10. INSTALLATION COMMENTS REQUIRE | | "MECHANICALLY FASTEN WITH APPROPRIATE HARDWARE". NO | | DETAIL PROVIDED. PROVIDE DETAIL OF EXISTING WALL TYPE | | WITH FASTENER SIZE AND LENGTH FOR WALL TYPE. | | 8. PROVIDE WIND LOAD DESIGN PER ASCE 7-10 FOR EACH | | LETTER TYPE. PROVIDE FASTENER SCHEDULE FOR EACH LETTER | | TYPE. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2016-06-28 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-06-28 |
Time |
08:51 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-06-28 |
Time |
08:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2016-08-10 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-08-10 |
Time |
13:38 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-08-10 |
Time |
13:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2016-07-13 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-07-13 |
Time |
18:17 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-07-13 |
Time |
18:13 |
Sent To |
Z |
|
Notes |
2016-07-13 18:26:34 | REVIEW 2014 5TH FBC ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | | | | | - WEST PALM BEACH REQUIRES 2 SET OF COPIES PER | | APPLICATION SUBMITTAL SHOP DRAWINGS. | | | | - WHETHER THE CONTRACTOR OR LANDLORD INSTALLS THE SIGN | | EXTERIOR LIGHTING CONTROL PER FBC E C405.2.4 IS NOT | | RELEVANT. PLEASE ADD A NOTE ON THE PLANS WITH THIS | | MANDATORY REQUIREMENT. IF WORK IS TO BE DONE BY OTHERS | | KEEP IN MIND ALL ELECTRICAL WORK SHALL BE DONE A | | LICENSED PROFFESIONAL. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-06-27 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-06-27 |
Time |
08:51 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-06-27 |
Time |
08:47 |
Sent To |
B |
|
Notes |
2016-06-27 08:53:11 | REVIEW 2014 5TH FBC ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | | | | | - FBC E SECTION C405.2.4 EXTERIOR LIGHTING CONTROLS. | | LIGHTING NOT DESIGNATED FOR DUSK-TO-DAWN OPERATION | | SHALL BE CONTROLLED BY EITHER A COMBINATION OF A | | PHOTOSENSOR AND A TIME SWITCH, OR AN ASTRONOMICAL TIME | | SWITCH. LIGHTING DESIGNATED FOR DUSK-TO-DAWN OPERATION | | SHALL BE CONTROLLED BY AN ASTRONOMICAL TIME SWITCH OR | | PHOTOSENSOR. | | ALL TIME SWITCHES SHALL BE CAPABLE OF RETAINING | | PROGRAMMING AND THE TIME SETTING DURING LOSS OF POWER | | FOR A PERIOD OF AT LEAST 10 HOURS. (ADD TO ELECTRICAL | | GENERAL NOTES) |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-08-19 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2016-08-19 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2016-08-04 |
Time |
14:56 |
Sent To |
|
|
Notes |
2016-08-04 14:57:01 | RESUB ROUTED TO ESCHNEIDER VIA ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-07-22 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2016-07-22 |
Time |
14:24 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2016-07-06 |
Time |
14:31 |
Sent To |
|
|
Notes |
2016-07-06 14:31:24 | RESUB ROUTED TO ESCHNEIDER VIA ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-06-28 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-06-28 |
Time |
08:51 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-06-08 |
Time |
10:15 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2016-08-18 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2016-08-18 |
Time |
10:28 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2016-08-18 |
Time |
08:49 |
Sent To |
PC |
|
Notes |
2016-08-18 10:29:31 | SIGNAGE PERMITTED: 24 SF | | PROPOSED SIGN: 16.6 SF | | | | | 2016-08-05 08:32:22 | ROUTED TO ERIC SCHNEIDER |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2016-07-22 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2016-07-22 |
Time |
14:22 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2016-07-22 |
Time |
13:34 |
Sent To |
|
|
Notes |
2016-07-22 14:24:19 | FAILED | | | | PROVIDE WRITTEN RESPONSE. | | | | 1) REPEAT COMMENT: ZONING STAFF IS NOT CLEAR AS TO WHAT | | THE PERMIT IS SUPPOSED TO COVER. THE PERMIT STATES IT | | IS FOR ILLUMINATED CHANNEL LETTERS, WHICH ARE ONLY | | PERMITTED ON THE EXTERIOR FA?ADE OF THE BUILDING. THERE | | IS ALSO A SHEET FOR A NON-ILLUMINATED SIGN THAT APPEARS | | TO BE INSIDE THE ARCADE. IF THE PERMIT DOES NOT INCLUDE | | THE INTERIOR SIGN, THEN THIS SHEET SHALL BE REMOVED | | FROM THE PERMIT PACKAGE. IF IT IS INCLUDED, THE PERMIT | | VALUE SHALL BE INCREASED ACCORDINGLY. | | | | 2) SIGN IS LOCATED ON THE EXTERIOR OF THE ARCADE MEETS | | CITYPLACE SIGN CODE. | | | | SIGNAGE PERMITTED: 24 SF | | PROPOSED SIGN: 16.6 SF | | | | 3) SIGN LOCATED ON THE INTERIOR OF THE ARCADE MEETS | | CITYPLACE SIGN CODE. | | | | SIGNAGE PERMITTED: 24 SF | | PROPOSED SIGN: 7.4 SF | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | 2016-07-14 08:09:12 | ROUTED TO ERIC SCHNEIDER |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2016-06-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-06-28 |
Time |
08:51 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2016-06-17 |
Time |
17:07 |
Sent To |
E |
|
Notes |
2016-06-22 19:44:15 | FAILED | | | | PROVIDE WRITTEN RESPONSE. | | | | 1) STAFF IS NOT CLEAR AS TO WHERE THIS SIGN IS TO BE | | LOCATED. THE PACKET PROVIDED BY SECURITY SIGNS SHOWS | | THE SIGN LOCATED ABOVE THE ENTRANCE TO THE STORE, WHICH | | MAKES IT AN INTERIOR ARCADE SIGN. THESE SIGNS MAY NOT | | BE ILLUMINATED. BARON SIGN PLANS SHOW THE SIGN AS | | LOCATED ON THE EXTERIOR OF THE ARCADE. THESE SIGNS MAY | | BE ILLUMINATED. | | | | 2) IF THE SIGN IS LOCATED ON THE EXTERIOR OF THE | | ARCADE, IT IS PERMITTED. | | | | SIGNAGE PERMITTED: 24 SF | | PROPOSED SIGN: 16.6 SF | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|