Plan Review Details - Permit 16060185
Plan Review Stops For Permit 16060185
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2016-06-17 Cont ID  
Sent By jwitmer Date 2016-06-17 Time 10:10 Rev Time 0.00
Received By jwitmer Date 2016-06-17 Time 09:38 Sent To  
Notes
2016-06-17 10:09:57BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16060185
 ADD: 6001 VILLAGE BLVD.
 CONT: TBD/ TO BE DETERMINED
 TEL: 561-685-9256/ RICK BRADENBURG
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: FRI. JUNE 17/2016
 ACTION: BUILDING PROVISO
  
 1) SHEET A-2.0 THE NEW GYM DOOR DOORS ARE SHOWN ON THE
 PLANS BUT THERE IS NO MENTION OF PANIC HARDWARE. THE
 GYM HAS APPROXIMATELY 1276 SQ. FEET IN THE ROOM. IF
 THERE IS EQUIPMENT IN THE GYM THE OCCUPANT LOAD WOULD
 BE 26. IF THERE IS NO EQUIPMENT IN THE ROOM THE
 OCCUPANT LOAD WOULD BE 85 REQUIRING PANIC OR
 FIRE EXIT HARDWARE. SEE THE 2014 FBC-B 1008.1.10 PANIC
 AND FIRE EXIT HARDWARE. DOORS SERVING A GROUP H
 OCCUPANCY AND DOORS SERVING ROOMS OR SPACES WITH AN
 OCCUPANT LOAD OF 50 OR MORE IN A GROUP A OR E OCCUPANCY
 SHALL NOT BE PROVIDED WITH A LATCH OR LOCK UNLESS IT IS
 PANIC HARDWARE OR FIRE EXIT HARDWARE.
  
 2) SHEET A-2.0 & A-3-0. THE SECOND ISSUE PLEASE PROVIDE
 AN ACCESSIBLE COAT HOOK INCOMPLIANCE WITH 2014
 FBC-ACCESS. CODE 803.5 COAT HOOKS AND SHELVES. COAT
 HOOKS PROVIDED WITHIN THE ROOM SHALL BE LOCATED WITHIN
 ONE OF THE REACH RANGES SPECIFIED IN 308. SHELVES SHALL
 BE 40 INCHES (1015 MM) MINIMUM AND 48 INCHES (1220 MM)
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-07-27 Cont ID  
Sent By ccole Date 2016-08-01 Time 17:33 Rev Time 0.00
Received By vperez Date 2016-07-27 Time 08:05 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-06-25 Cont ID  
Sent By vperez Date 2016-06-25 Time 14:58 Rev Time 0.00
Received By vperez Date 2016-06-25 Time 14:58 Sent To  
Notes
2016-06-25 15:01:35INITIAL ELECTRICAL PLAN REVIEW
  
 APPLICABLE CODES IN EFFECT:
 FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70- 2011 NEC
 COMMENTS:
  
 1. PROVIDE SIZE OF THE OVERCURRENT PROTECTION AT PANEL
 GDA.
 2. PROVIDE A BLOCK NOTE INDICATING THE REQUIRED
 SEPARATE PERMITS AND DATA CUT SHEET SUBMITTALS FOR FIRE
 ALARM SHOWN AND ASSOCIATED EQUIPMENT. A NOTE WILL
 SUFFICE.
 3. PROVIDE A ?? DETAIL OF THE MECHANICAL ROOM WHERE
 EQUIPMENT IS BEING RELOCATED. PROVIDE CLEARANCES. NEC
 110.26
 4. ADDRESS MECHANICAL COMMENTS FOR A COMPLETE REVIEW.
 5. COMMENTS MAY FOLLOW UPON RE-REVIEW. PLEASE FEEL FREE
 TO CONTACT ME SHOULD YOU HAVE ANY QUESTIONS REGARDING
 THIS PROJECT.
  
  
 VALENTINO PEREZ
 ELECTRICAL PLANS EXAMINER II
 561-805-6717
 [email protected]
  
  
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2016-06-09 Cont ID  
Sent By wjolin Date 2016-06-09 Time 12:37 Rev Time 0.00
Received By wjolin Date 2016-06-09 Time 11:13 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-08-01 Cont ID  
Sent By ccole Date 2016-08-01 Time 17:33 Rev Time 0.00
Received By ccole Date 2016-07-25 Time 11:25 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-06-25 Cont ID  
Sent By vperez Date 2016-06-25 Time 15:01 Rev Time 0.00
Received By vperez Date 2016-06-25 Time 15:01 Sent To  
Notes
2016-06-06 11:09:45B14

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2016-06-17 Cont ID  
Sent By jwitmer Date 2016-06-17 Time 09:39 Rev Time 0.00
Received By jwitmer Date 2016-06-17 Time 09:39 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2016-08-11 Cont ID  
Sent By ccole Date 2016-08-01 Time 17:33 Rev Time 0.00
Received By ccole Date 2016-08-01 Time 17:33 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-06-10 Cont ID  
Sent By ccole Date 2016-06-10 Time 14:04 Rev Time 0.00
Received By ccole Date 2016-06-10 Time 14:04 Sent To  
Notes
2016-06-10 14:24:361ST REVIEW: FBC 2014 MECHANICAL
 PERMIT #16060185
 6/10/16
  
 1) PROVIDE A LIST OF CURRENT CODES AND STANDARDS USED
 IN THE DESIGN OF THE PROJECT- SECTION 101.2 FBC-14
 BUILDING.
  
 2) PROVIDE THE LEVEL OF ALTERATION PER CHAPTER 5 FBC-14
 EXISTING BUILDING.
  
 3) REFER TO SECTION 809.2 FBC-14 EXISTING BUILDING CODE
 AND PROVIDE MINIMUM VENTILATION CALCULATIONS FOR ALL
 ROOMS AND SPACES PER TABLE 403.3 FBC-14 MECHANICAL.
 PROVIDE A TABLE ON THE PLAN INDICATING THE REQUIRED AND
 PROVIDED CFMS OF OUTDOOR AIR FOR THE NEW LOCKER ROOMS.
  
 4) IN ACCORDANCE WITH TABLE 403.3 THE LOCKERS ROOMS
 MUST HAVE EXHAUST VENTILATION RATES OF .25 CFM'S PER
 SQUARE FOOT. PROVIDE EXHAUST CALCULATIONS ON THE PLAN
 FOR BOTH THE LOCKER ROOMS AND THE MEN'S AND WOMEN'S
 BATHROOMS. IT APPEARS THAT NO EXHAUST SYSTEM HAS BEEN
 PROVIDED FOR THE LOCKER ROOMS- PLEASE REVISE THE PLANS
 TO MEET COMPLIANCE, AND SEE FOOTNOTE G CONCERNING THE
 TRANSFER DUCTS: THE TRANSFER CFM'S SHALL NOT EXCEED 10%
 OF THE AIR IN THE LOCKER AND BATHROOM SPACES.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-08-01 Cont ID  
Sent By gjohnson Date 2016-08-01 Time 15:52 Rev Time 0.00
Received By gjohnson Date 2016-08-01 Time 15:37 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-06-20 Cont ID  
Sent By gjohnson Date 2016-06-20 Time 08:46 Rev Time 0.00
Received By gjohnson Date 2016-06-20 Time 08:46 Sent To  
Notes
2016-06-20 10:45:56PLUMBING COMMENTS:
  
 1. SHOW GRAB BARS IN SHOWER TO COMPLY WITH FBC ACC.SEC.
 608.3.1 TRANSFER TYPE SHOWER COMPARTMENTS.
 IN TRANSFER TYPE COMPARTMENTS, GRAB BARS SHALL BE
 PROVIDED ACROSS THE CONTROL WALL AND BACK WALL TO A
 POINT 18 INCHES (455 MM) FROM THE CONTROL WALL.
  
 2. SHOW CONTROLS TO COMPLY WITH FBC ACC. SEC. 608.5.1
 TRANSFER TYPE SHOWER COMPARTMENTS.
 IN TRANSFER TYPE SHOWER COMPARTMENTS, THE CONTROLS,
 FAUCETS, AND SHOWER SPRAY UNIT SHALL BE INSTALLED ON
 THE SIDE WALL OPPOSITE THE SEAT 38 INCHES (965 MM)
 MINIMUM AND 48 INCHES (1220 MM) MAXIMUM ABOVE THE
 SHOWER FLOOR AND SHALL BE LOCATED ON THE CONTROL WALL
 15 INCHES (380 MM) MAXIMUM FROM THE CENTERLINE OF THE
 SEAT TOWARD THE SHOWER OPENING.
  
 3. SHOW SHOWER SEAT TO COMPLY WITH FBC ACC. SEC. 610.3
 SHOWER COMPARTMENT SEATS. IN TRANSFER-TYPE SHOWERS, THE
 SEAT SHALL EXTEND FROM THE BACK WALL TO A POINT WITHIN
 3 INCHES (75 MM) OF THE COMPARTMENT ENTRY. SEATS SHALL
 COMPLY WITH 610.3.1 OR 610.3.2.
  
 4. SHOW ELEVATION DIMENSIONS OF WATER FOUNTAIN THEY
 SHALL COMPLY WITH FBC ACC. SEC 306.2-306.3-307
  
  
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
  