Plan Review Stops For Permit 16051290 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2016-11-07 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-11-07 |
Time |
16:48 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-11-07 |
Time |
16:06 |
Sent To |
|
|
Notes |
2016-11-07 16:28:18 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 16051290 | | ADD: 701 S. ROSEMARY AVE. SUITE : 101 | | CONT: TBD/ TO BE DETERMINED | | TEL: 856-6655/ NEYITA LEIVA | | E-MAIL: | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 5TH REVIEW | | DATE: MON. NOV. 07/ 2016 | | ACTION: PASSED | | | | 1) RESPONSE COMMENTS INDICATE THAT WINDOWS AND DOORS | | ARE TO BE UNDER SEPARATE PERMIT WITH ASSOCIATED FEES | | AND REVIEW. NOT INCLUDED IN THE MAIN PERMIT. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2016-10-29 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-10-29 |
Time |
11:01 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-10-29 |
Time |
11:01 |
Sent To |
|
|
Notes |
2016-10-29 11:03:11 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 16051290 | | ADD: 701 S. ROSEMARY AVE. SUITE : 101 | | CONT: TBD/ TO BE DETERMINED | | TEL: 856-6655/ NEYITA LEIVA | | E-MAIL: [email protected] | | | | FAILED, SEE ZONING COMMENTS NEW SHEETS WILL BE ADDED, | | TO BE REVIEWED AND STAMPED AT THAT TIME.NO ISSUE WITH | | CURRENT PLANS. | | | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | DEVELOPMENT SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2016-10-13 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-10-13 |
Time |
08:46 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-10-13 |
Time |
07:32 |
Sent To |
|
|
Notes |
2016-10-13 08:46:23 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 16051290 | | ADD: 701 S. ROSEMARY AVE. SUITE : 101 | | CONT: TBD/ TO BE DETERMINED | | TEL: 856-6655/ NEYITA LEIVA | | E-MAIL: | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 3RD REVIEW | | DATE: THURS. OCT. 13/ 2016 | | ACTION: DENIED | | | | 1) PLANS APPEAR TO BE CODE COMPLIANT, PAGES WILL NEED | | TO BE UPDATED TO COMPLY WITH ZONING REQUIREMENTS. WHEN | | RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | 2) RESPONSE COMMENTS INDICATE THAT WINDOWS AND DOORS | | ARE TO BE UNDER SEERATE PERMIT WITH ASSOICATED FEES AND | | REVIEW. NOT INCLUDED IN THE MAIN PERMIT. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2016-08-13 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-08-13 |
Time |
14:15 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-08-13 |
Time |
|
Sent To |
|
|
Notes |
2016-08-05 07:09:10 | 08/01/2016 NO PLAN IN CUBICLE< NOT SIGNED | | OUT!!!!!!!!!!!!!!!!!!!!!!!!!! | | 08/05/2016 NO PLAN IN CUBICLE< NOT SIGNED | | OUT!!!!!!!!!!!!!!!!!!!!!!!!!! | | 08/10/2016 NO PLAN IN CUBICLE< NOT SIGNED | | OUT!!!!!!!!!!!!!!!!!!!!!!!!!!! | | | | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 16051290 | | ADD: 701 S. ROSEMARY AVE. SUITE : 101 | | CONT: TBD/ TO BE DETERMINED | | TEL: 856-6655/ NEYITA LEIVA | | E-MAIL: | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE: SAT. AUGUST 13/ 2016 | | ACTION: DENIED | | | | NOTICE: NEXT REVIEW CYCLE PLEASE CORRELATE SHEETS SO | | THEY WILL BE IN ORDER SHEETS S-3.0 AND S-3.1 ARE OUT OF | | ORDER AT THE BACK OF THE PLANS!!!!!1 | | | | | | 1-5) COMPLIED. | | | | 6A) 2ND REQUEST. THE A-8.0 SHEET HAS BEEN REVISED BUT | | THE ARCHITECTURAL SHEET FOR THIS DETAIL AND THE | | STRUCTURAL SHEETS S-3.0 FOR THE SAME ISSUES DO NOT | | MATCH THE MATERIAL TO BE INSTALLED. | | DISCREPANCY IN PLANS, 107.2.1.3. ADDITIONAL INFORMATION | | REQUIRED. | | 1ST ROUND OF COMMENT. SHEET A-8.0 DETAILS SHOW THE USE | | OF STEEL TUBES IN THE HEADER AND SILL DESIGN WHERE AS | | THE STRUCTURAL SHEET S-3.0 DETAIL # 1 SHOWS THE USE OF | | A CONCRETE SILL AND CONCRETE LINTEL AND STEEL. | | DISCREPANCY IN PLANS, 107.2.1.3. ADDITIONAL INFORMATION | | REQUIRED. | | | | 6B) COMPLIED. | | | | 7-8) DEFERRED SUBMITTALS: 2014 FBC-B 1609.1.2 | | PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS & | | CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE | | 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR | | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | APPROVALS: | | (31)(A) EXTERIOR DOORS. | | (B) WINDOWS | | (G) ROOF TOP CURBS, PRE-ENGINEERED A/C STANDS | | | | 8) 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA | | RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN WRITING BY | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL. | | | | 9) 2ND REQUEST. PROVIDE ENGINEERED DETAILS FOR MOUNTING | | OACU-1 CURB TO THE ROOF STRUCTURE AND THE UNIT TO THE | | CURB. SHEET S-2.2 INDICATES DETAILS FOR OACU-1, & | | OACU-2 FOUND ON SHEET S3.1 SEE DETAIL # 1 CUT SECTION | | THAT SHOWS THE ADDITIONAL ROOF FRAMING REQUIRED. NOTE | | CURB MOUNTED CONDENSING UNITS SEE MECH. DRAWINGS. SHEET | | M7.2 CURB ROOF DETAILS. IN THE DETAIL THERE IS A | | SPECIAL NOTE. FOR BOTH THE ATTACHMENT OF THE CURB TO | | THE ROOF FRAMING AND THE UNIT TO THE CURB TO BE | | DETERMINED AND VERIFIED BY THE STRUCTURAL ENGINEER. | | ADDITIONAL ENGINEERING CALS. DATED JULY 22/ 2016 PAGES | | 1-5 C & C ROOF TOP EQUIPMENT AND PAGE 6 REACTIONS DUE | | TO WIND OVERTURNING ON THE CU EQUIPMENT. THE | | CALCULATIONS FOR THE LOADS TO BE RESISTED ARE THERE BUT | | NOT THE ATTACHMENT METHOD TO RESIST THE LOADS FOR THE | | CURB TO THE ROOF FRAMING MEMBERS NOR THE ROOF TOP UNIT | | TO THE CURB!!!!!! | | | | COMMENT FROM THE 1ST REVIEW CYCLE. PROVIDE ENGINEERED | | DETAILS FOR MOUNTING OACU-1 CURB TO THE ROOF STRUCTURE | | AND THE UNIT TO THE CURB. | | 2014 FBC-B 2014 FBC-B 1604.4 ANALYSIS. LOAD EFFECTS ON | | STRUCTURAL MEMBERS AND THEIR CONNECTIONS SHALL BE | | DETERMINED BY METHODS OF STRUCTURAL ANALYSIS THAT TAKE | | INTO ACCOUNT EQUILIBRIUM, GENERAL STABILITY, GEOMETRIC | | COMPATIBILITY AND BOTH SHORT- AND LONG-TERM MATERIAL | | PROPERTIES. EVERY STRUCTURE SHALL BE DESIGNED TO RESIST | | THE OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES | | SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND | | LOADS? | | 2014 FBC-M- 301.15 WIND RESISTANCE. MECHANICAL | | EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO | | WIND SHALL BE DESIGNED AND INSTALLED TO RESIST THE WIND | | PRESSURES DETERMINED IN ACCORDANCE WITH THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 10) 2ND REQUEST. PLEASE INDICATE IF THIS PERMIT IS FOR | | A CHANGE OF OCCUPANCY TO AN A2 OCCUPANCY. IF SO PLANS | | ARE TO BE SUBMITTED TO P.B.C. IMPACT FEE OFFICE FOR | | IMPACT FEE ASSESSMENT. | | | | 11) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-06-15 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-06-15 |
Time |
08:02 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-06-14 |
Time |
13:31 |
Sent To |
|
|
Notes |
2016-06-15 08:02:28 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 16051290 | | ADD: 701 S. ROSEMARY AVE. SUITE : 101 | | CONT: TBD/ TO BE DETERMINED | | TEL: 856-6655/ NEYITA LEIVA | | E-MAIL: | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: TUES. JUNE 14/ 2016 | | ACTION: DENIED | | | | 1) AN-1.0 PROJECT INFORMATION/ CODE REFERENCES | | 1A) 2001/2004 W. P. B. AMENDMENTS ARE NO LONGER IN | | AFFECT, THEY SUNDOWN WITH THE ADOPTION OF THE NEWLY | | ADOPTED W. P. B. AMENDMENTS. 2010 W. P. B. AMENDMENTS | | ARE STILL IN AFFECT. | | | | 1B) THE UNSAFE BUILDING ABATEMENT CODE: IS A P. B. | | COUNTY CODE NOT A CITY OF WEST PALM BEACH ORDINANCE. | | | | 1C) ULDC ARTICLE 18 FLOOD DAMAGE PREVENTION IS ALSO A | | PALM BEACH COUNTY DOCUMENT THAT DOES NOT PERTAIN TO THE | | CITY OF WEST PALM BEACH. THIS JOBSITE IS NOT LOCATED IN | | AN A FLOOD ZONE. | | | | 1D) THE CODE REFERENCE FORM THE 2014 FBC-B FIGURE 1609C | | ULTIMATE WIND SPEEDS RISK CATEGORY I BUILDINGS. PLEASE | | NOTE THIS WIND DESIGN OF 160 VULT IS FOR BUILDINGS SUCH | | AS AGRICULTURAL OUT BUILDINGS (BARNS), MINOR STORAGE | | BUILDINGS AND SCREEN ENCLOSURES, 2014 FBC-B TABLE | | 1604.5. RISK CATEGORY OF BUILDINGS AND OTHER | | STRUCTURES. THIS BUILDINGS RISK CATEGORY SHOULD BE RISK | | CATEGORY II, FIGURE 1609B AND A VULT WIND SPEED OF 170 | | VULT. THE STRUCTURAL SHEET S-1.0 DOES HAVE THE CORRECT | | WIND DESIGN CRITERIA. | | | | 2) THE DETAILS ON SHEET S-3.0 DETAILS 2 & 3 BOTH | | INDICATE THE USE OF POLYSTYRENE STRUCTURAL FOAM. THE | | SUBMITTED DETAILS ONLY SHOW THE FOAM BEING ENCASED IN | | ONE DIRECTION. PLEASE PROVIDE A CROSS SECTION 90 | | DEGREES OF THOSE SHOWN, SHOWING THE FOAM BEING FULLY | | ENCASED BY THE CONCRETE, SEE FBC-B 2603.4.1.1. | | | | 3A) SHEETS AN-3.0, A-2.1 & A-5.0 ALL OF THESE SHEETS | | SHOW THE FLOOR PLAN WITH THE FURNITURE, NONE SHOW | | COMPLIANCE WITH THE 2014 FBC-ACCESS. CODE SECTION 226.1 | | GENERAL. WHERE DINING SURFACES ARE PROVIDED FOR THE | | CONSUMPTION OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE | | SEATING SPACES AND STANDING SPACES AT THE DINING | | SURFACES SHALL COMPLY WITH 902. | | | | 3B) SHEETS AN-3.0, A-2.1 & A-5.0 ALL OF THESE SHEETS | | SHOW THE FLOOR PLAN WITH THE FURNITURE, NONE SHOW | | COMPLIANCE WITH THE 2014 FBC-ACCESS. CODE SECTION 226.2 | | DISPERSION. DINING SURFACES AND WORK SURFACES REQUIRED | | TO COMPLY WITH 902 SHALL BE DISPERSED THROUGHOUT THE | | SPACE OR FACILITY CONTAINING DINING SURFACES AND WORK | | SURFACES. PLEASE NOTE INCLUDE THE SEASONAL SEATING AS | | WELL AS THE SEATING AT FN-13. | | | | 3C) SHEETS AN-3.0, A-2.1 & A-5.0 ALL OF THESE SHEETS | | SHOW THE FLOOR PLAN WITH THE FURNITURE, NONE SHOW | | COMPLIANCE WITH THE 2014 FBC-ACCESS. CODE SECTIONS: | | 3C)(1) 902.2 CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR | | SPACE COMPLYING WITH 305 POSITIONED FOR A FORWARD | | APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE | | COMPLYING WITH 306 SHALL BE PROVIDED. | | | | 3C)(2) 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND | | WORK SURFACES SHALL BE 28 INCHES (710 MM) MINIMUM AND | | 34 INCHES (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR | | GROUND. | | | | 4) SHEET A-7.4 SHOWS THE LAYOUT OF THE SMALL CAF?. | | DETAIL (8) AN ELEVATION SHOWS AN ELEVATION OF 3 FT. 6 | | INCHES FOR THE BAR SEATING, BUT THE DETAIL FOR THE | | ACCESSIBLE SEATING DOES NOT SHOW THE HEIGHT OF THE | | ACCESSIBLE TOP. PLEASE SHOW COMPLIANCE WITH 2014 | | FBC-ACCESS. CODE 902.3 HEIGHT. THE TOPS OF DINING | | SURFACES AND WORK SURFACES SHALL BE 28 INCHES (710 MM) | | MINIMUM AND 34 INCHES (865 MM) MAXIMUM ABOVE THE FINISH | | FLOOR OR GROUND. | | | | 5) SHEET A7.1 DETAIL # 6 RAMP ELEVATION & HANDRAILS. | | THE HANDRAILS ARE MISSING THE HORIZONTAL EXTENSION AT | | THE TOP AND BOTTOM OF THE RAMP. SEE THE 2014 | | FBC-ACCESS. CODE 505.10.1 & FIGURE 505.10.1. | | | | 6A) SHEET A-8.0 DETAILS SHOW THE USE OF STEEL TUBES IN | | THE HEADER AND SILL DESIGN WHERE AS THE STRUCTURAL | | SHEET S-3.0 DETAIL # 1 SHOWS THE USE OF A CONCRETE SILL | | AND CONCRETE LINTEL AND STEEL. DISCREPANCY IN PLANS, | | 107.2.1.3. ADDITIONAL INFORMATION REQUIRED. | | | | 6B) SHEET S-3.0 DETAIL # 1 INDICATES THE USE OF A | | LINTEL WITH CONCRETE W NUMBER 4 STIRRUPS AT 4 INCHES ON | | CENTER, W 2 # 5S ON TOP AND BOTTOM. IS THIS A | | PRE-MANUFACTURED LINTEL, OR A POUR IN PLACE BEAM? | | 107.2.1.3. ADDITIONAL INFORMATION REQUIRED. | | | | 7) 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | WILL REQUIRE PRODUCT APPROVALS: | | (31)(A) EXTERIOR DOORS. | | (B) WINDOWS | | (G) ROOF TOP CURBS, PRE-ENGINEERED A/C STANDS | | | | 8) 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA | | RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN WRITING BY | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL. | | | | 9) PROVIDE ENGINEERED DETAILS FOR MOUNTING OACU-1 CURB | | TO THE ROOF STRUCTURE AND THE UNIT TO THE CURB. | | 2014 FBC-B 2014 FBC-B 1604.4 ANALYSIS. LOAD EFFECTS ON | | STRUCTURAL MEMBERS AND THEIR CONNECTIONS SHALL BE | | DETERMINED BY METHODS OF STRUCTURAL ANALYSIS THAT TAKE | | INTO ACCOUNT EQUILIBRIUM, GENERAL STABILITY, GEOMETRIC | | COMPATIBILITY AND BOTH SHORT- AND LONG-TERM MATERIAL | | PROPERTIES. EVERY STRUCTURE SHALL BE DESIGNED TO RESIST | | THE OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES | | SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND | | LOADS? | | 2014 FBC-M- 301.15 WIND RESISTANCE. MECHANICAL | | EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO | | WIND SHALL BE DESIGNED AND INSTALLED TO RESIST THE WIND | | PRESSURES DETERMINED IN ACCORDANCE WITH THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 9) PLEASE INDICATE IF THIS PERMIT IS FOR A CHANGE OF | | OCCUPANCY TO AN A2 OCCUPANCY. IF SO PLANS ARE TO BE | | SUBMITTED TO P.B.C. IMPACT FEE OFFICE FOR IMPACT FEE | | ASSESSMENT. | | | | 10) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | THIS REVIEW. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2016-11-10 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-11-10 |
Time |
07:50 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-11-10 |
Time |
07:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2016-08-12 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-08-12 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-08-12 |
Time |
11:36 |
Sent To |
|
|
Notes |
2016-08-09 09:34:37 | COULD NOT FIND PLANS. PACKET IN BIN C38 IS INCOMPLETE. | | ITEMS RETURNED TO BIN. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-06-23 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-06-23 |
Time |
08:17 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-06-22 |
Time |
13:24 |
Sent To |
|
|
Notes |
2016-06-23 09:00:48 | INITIAL ELECTRICAL PLAN REVIEW | | | | APPLICABLE CODES IN EFFECT: | | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70- 2011 NEC | | COMMENTS: | | | | 1. GENERAL NOTES- PROVIDE A BLOCK NOTE INDICATING THE | | REQUIRED SEPARATE PERMITS AND DATA CUT SHEET SUBMITTALS | | FOR ALL LOW VOLTAGE SYSTEMS TO INCLUDE BUT NOT LIMITED | | TO FIRE ALARM, ACCESS CONTROLS, CCTV, PHONE AND DATA, | | SIGNAGE, WIRELESS SYSTEMS, ETC. A NOTE WILL SUFFICE. | | 2. PROVIDE A NOTE/SIGN TO INDICATE THE REQUIREMENTS NEC | | 110.24 THE MAX. AVAILABLE FAULT CURRENT SHALL BE | | DURABLY MARKED AND DATED ON ALL ELECTRICAL APPARATUS | | AND NEC 110.16 ARC-FLASH HAZARD WARNING LABELS | | REQUIRED. | | 3. PER FBC EC 405.7.3- SHOW VOLTAGE DROP CALCULATIONS | | FOR FEEDERS AND BRANCH CIRCUITS. | | 4. PER FBC EC 405.7- 50% OF ALL RECEPTACLES 125V, 15 | | AND 20A MUST BE AUTOMATICALLY CONTROLLED WHERE | | INSTALLED IN PRIVATE OFFICES, OPEN OFFICES, AND | | COMPUTER CLASSROOMS. THIS INCLUDES THOSE INSTALLED IN | | MODULAR PARTITIONS. SHOW COMPLIANCE. | | 5. PROVIDE A NOTE TO COMPLY WITH TAP RULES ON RISER | | DIAGRAM AT THE INTERIOR OF ELECTRICAL ROOM PER NEC | | 240.21. A NOTE WILL SUFFICE. | | 6. PLEASE DELETE REFERENCE TO CITY OF MIAMI COMPLIANCE | | AND SHOW WPB COMPLIANCE. | | 7. COMMENTS MAY FOLLOW UPON RE-REVIEW. PLEASE FEEL FREE | | TO CONTACT ME SHOULD YOU HAVE ANY QUESTIONS REGARDING | | THIS PROJECT. | | | | | | VALENTINO PEREZ | | ELECTRICAL PLANS EXAMINER II | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2016-11-16 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2016-11-16 |
Time |
10:17 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2016-11-16 |
Time |
10:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2016-07-28 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2016-07-28 |
Time |
12:58 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2016-07-28 |
Time |
12:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2016-06-01 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2016-06-01 |
Time |
11:09 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2016-06-01 |
Time |
10:34 |
Sent To |
|
|
Notes |
2016-06-01 11:09:11 | 701 SOUTH ROSEMARY AVENYE SUITE 101 | | PERMIT #16051290 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | *****PROVISO***** | | | | PROVIDE A LIFE SAFETY PLAN SHOWING OCCUPANT LOADS AND | | REQUIRED EXITS. COORDINATE THE REQUIRED EXITS WITH THE | | ELECTRICAL ENGINEER AS ALL EXTERIOR DOORS APPEAR TO | | HAVE ILLUMINTED EXIT SIGNS. ALL EXTERIOR DOORS NOT | | FUNCTIONING AS EXITS SHALL BE PERMANENTLY MARKED AND | | CLEARLY INDICATED AS, "NOT AN EXIT." | | | | DOOR #115 DOES NOT APPEAR TO BE EQUIPPED WITH PANIC | | HARDWARE. | | | | WESLEY JOLIN | | ASSISTANT FIRE MARSHAL | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 | | | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2016-11-16 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2016-11-16 |
Time |
14:45 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2016-11-01 |
Time |
10:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2016-10-29 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-10-29 |
Time |
11:03 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-10-13 |
Time |
16:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-10-13 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-10-13 |
Time |
08:46 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-09-16 |
Time |
13:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-08-22 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-08-22 |
Time |
14:46 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-07-26 |
Time |
15:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-06-23 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-06-23 |
Time |
09:00 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-06-23 |
Time |
09:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
N |
Date |
2016-10-13 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-10-13 |
Time |
07:51 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2016-10-13 07:52:21 | PLANS STAMPED BY P. B. COUNTY IMPACT FEE OFFICE, NO | | FEES DUE. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2016-08-13 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-08-13 |
Time |
14:00 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-08-05 |
Time |
07:03 |
Sent To |
|
|
Notes |
2016-08-13 14:06:14 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2016-06-15 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-06-15 |
Time |
08:02 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-06-15 |
Time |
08:02 |
Sent To |
|
|
Notes |
2016-06-15 08:03:15 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2016-09-28 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-09-28 |
Time |
15:24 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-09-28 |
Time |
12:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2016-08-11 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-08-11 |
Time |
11:58 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-08-05 |
Time |
10:26 |
Sent To |
|
|
Notes |
2016-08-05 10:26:30 | 8/5/16 | | RE-SUBMITTED PLANS ARE MISSING. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | | | 2ND REVIEW FBC-2014 MECHANICAL | | PERMIT #16051290 | | 8/11/16 | | | | 1) THE ENERGYGAUGESUMMIT SUBMITTAL DOES NOT INCLUDE | | COMPLIANCE DATA FOR THE WATER HEATER OR THE CHILLED | | WATER PIPING AND INSULATION. | | | | 2) REFER TO COMMENT #4 FROM THE 1ST REVIEW AND SUBMIT | | MANUFACTURER'S SPECIFICATIONS FOR THE CONVECTION OVEN. | | PROVIDE EXHAUST AS REQUIRED BY SECTION 507.2.2 AND | | TABLE 6-4 ASHRAE 62.1-2010. | | | | 3) COMMENT #8 FROM THE 1ST REVIEW STILL EXISTS- | | ENGINEERED DETAILS FOR INSTALLATION OF OACU-1 & 2 NOT | | SHOWN ON THE PLAN, ALTHOUGH STRUCTURAL CALCULATIONS | | HAVE BEEN SUBMITTED FOR REVIEW. THE REQUESTED | | MIAMI-DADE ROOF STAND NOA NOT SUBMITTED. | | | | 4) COMMENT #11 FROM THE 1ST REVIEW STILL EXISTS. AS | | PREVIOUSLY REQUESTED PROVIDE THE FLEX DUCT SIZES ON THE | | PLAN, OR RELOCATE THE AIR DISTRIBUTION AND FLEX DUCT | | SCHEDULE TO THE M2.1 PLAN SHEET (MECHANICAL DUCTWORK | | PLAN). | | | | 5) PROVIDE SUBMITTALS FOR ALL PIPING INSULATIONS TO BE | | INSTALLED IN THE RETURN PLENUM, AND PLACE A NOTE ON | | M2.1 INDICATING THE AREA ABOVE THE CEILING IS A RETURN | | PLENUM- SEE SECTION 602. | | | | 6) M2.1: PROVIDE NOTES OR DETAILS TO INDICATE HOW | | SERVICE ACCESS TO ALL ABOVE CEILING MECHANICAL | | EQUIPMENT WILL BE PROVIDED- SECTION 306.1. | | | | 7) M2.1 & A1.0: REFER TO SECTION C403.2.7.3 AND TABLE | | C403.2.7.2 FBC-14 ENERGY CONSERVATION, AND SHOW | | COMPLIANCE FOR THE REQUIRED CONTINOUS AIR BARRIER | | FORMING THE ABOVE CEILING RETURN PLENUM. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | | | | | | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-06-02 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-06-02 |
Time |
08:04 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-06-02 |
Time |
08:04 |
Sent To |
|
|
Notes |
2016-06-02 08:05:48 | 1ST REVIEW: FBC 2014 MECHANICAL | | PERMIT #16051290 | | 6/1/16 | | | | 1) PROVIDE ENERGY CALCULATIONS IN COMPLIANCE WITH | | SECTIONS C101.4.4 AND C401.2 FBC-14 ENERGY | | CONSERVATION. | | | | 2) PROVIDE AC CALCULATIONS FOR THE MINI-SPLITS AND THE | | SCOP RATING OF AC-5 I N THE IT ROOM- SEE TABLE | | C403.2.3(10). | | | | 3) IT DOES NOT APPEAR THAT ADEQUATE HEATING IS BEING | | SUPPLIED TO ALL ROOMS AND SPACES BASED ON THE AC | | CALCULATIONS, AND THE EQUIPMENT SCHEDULES. PLEASE | | CLARIFY WHY MANY OF THE WT BOXES ARE NOT EQUIIPPED WITH | | HEAT- REFER TO SECTION 309.1 FBC-14 MECHANICAL. | | | | 4) TYPE II HEAT HOODS ARE REQUIRED FOR THE CONVECTION | | OVENS IN THE CAFE- SEE SECTION 507.2.2 AND REVISE THE | | PLAN ACCORDINGLY. SEE ALSO TABLE 6-4 ASHRAE 62.1- 2010 | | WHICH REQUIRES AN EXHAUST RATE OF 0.30 CFMS PER SF. | | FPOR KITCHENETTES. | | | | 5) THE EXHAUST DUCT FROM THE JANITOR'S CLOSET SHALL NOT | | CONNECT INTO THE MAIN DUCT SERVING THE RESTROOMS- | | SECTION 501.2 | | | | 6) THE RESTOOM EXHAUST FANS MUST HAVE A MINIMUM | | CAPACITY OF 140 CFMS EACH IN ACCORDANCE WITH TABLE | | 403.3. | | | | 7) PROVIDE AN EXHAUST VENTILATION CALCULATION FOR THE | | MULTI- FUNCTION ROOM, AND CLARIFY THE NEED FOR THE | | EXHAUST SYSTEM IN THE ROOM (WHAT WORK IS BEING | | CONDUCTED IN THE ROOM THAT REQUIRES EXHAUST?). SHOW THE | | EXHAUST DUCT RUN AND TERMINATION LOCATION. | | | | 8) PROVIDE ENGINEERED DETAILS FOR MOUNTING THE OACU-1 | | CURB TO THE ROOF STRUCTURE AND THE UNIT TO THE CURB- | | SECTION 301.15. SUBMIT TWO COPIES OF THE MIAMI-DADE NOA | | FOR THE CONDENSER STANDS APPROVED WITH SIGNATURE BY THE | | STRUCTURAL EOR. | | | | 9) PROVIDE BPD AND WT BOX INSTALLATION DETAILS. | | | | 10) PROVIDE SPECIFICATIONS FOR THE CHILLED WATER PIPING | | AND PIPE INSULATION. | | | | 11) SHEET M2.1: FLEX DUCT SIZES NOT SHOWN ON THE PLAN. | | A) PROVIDE A FIRE DAMPER FOR THE EXHAUST DUCT | | PENETRATING THE CORRIDOR WALL- SECTION 607.5.2. | | | | 12) M7.2: PROVIDE A DUCT SMOKE DETECTOR IN THE RETURN | | AIR DUCT SHOWN IN THE CARRIER CONTROLS DIAGRAM- SECTION | | 606.2.1. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2016-10-12 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-10-12 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-10-12 |
Time |
13:52 |
Sent To |
|
|
Notes |
2016-10-12 13:53:25 | APPROVED WITH PROVISO | | | | PLUMBING PROVISO: | | FOR THE DELETION OF GREASE INTERCEPTOR, MUST BE | | APPROVED BY BUILDING OFFICIAL. | | 1. PROVIDE TWO COPIES OF A LETTER FROM THE OWNER OR | | ARCHITECT STATING THERE WILL BE NO GREASE LADEN WASTE | | PRODUCED FROM COOKING OR CLEANING OF UTENSILS. | | 2. PROVIDE TWO COPIES OF MENU | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2016-08-22 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-08-22 |
Time |
14:34 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-08-22 |
Time |
12:55 |
Sent To |
|
|
Notes |
2016-08-22 14:45:32 | 1ST REVIEW | | | | | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | 1) GREASE INTERCEPTOR'S NOT VENTED PER MANUFACTURE | | INSTALLATION SPECIFICATIONS PLEASE CLARIFY. PER WPB | | AMEND TO FBC 107.2.1 | | | | 2) AUTOMATIC GREASE INTERCEPTOR IS SHOWN BELOW GRADE | | THIS MODEL IS REQUIRED TO BE MOUNTED ABOVE GRADE PLEASE | | CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | 4) 2ND REQUEST THE OCCUPANT LOAD CALCULATIONS SHOW AN | | OCCUPANT LOAD OF 153 PERSONS AND THE PLUMBING FIXTURE | | REQUIREMENTS NOTES 297 PERSONS. CLARIFY. | | | | 6) 2ND REQUEST SUBMIT FACTORY SIZING CALCULATIONS FOR | | THE GREASE TRAP & GREASE INTERCEPTOR. YOU CAN CONTACT | | LEE SCHNEEWEISS WITH SCHIER AT 1-800-538-4792. 2014 | | FBC-PLUMBING SEC.1003.2. | | | | | | 10) 2ND REQUEST SHT. P5.1 - THE SANITARY RISER SHOWS AN | | UNVENTED SINK (SK-1) DRAINING INTO THE TOP OF THE | | INTERCEPTOR.CLARIFY. | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2016-06-22 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-06-22 |
Time |
05:51 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-06-16 |
Time |
12:30 |
Sent To |
|
|
Notes |
2016-06-21 10:49:47 | 1) SHT. AN-1.0 - CODE REFERENCES - REFERENCE IS MADE TO | | THE 2001 WPB AMENDMENTS TO FBC. REVISE TO READ 2014 | | AMENDMENTS. | | 2) SHT.AN-3.0 - PLUMBING FIXTURE REQUIREMENTS - REFER | | TO TABLE 403.1 OF 2014 FLORIDA PLUMBING CODE. | | 3) IDENTIFY THE DIFFERENT OCCUPANCY AREAS ON THE PLAN. | | 4) THE OCCUPANT LOAD CALCULATIONS SHOW AN OCCUPANT LOAD | | OF 153 PERSONS AND THE PLUMBING FIXTURE REQUIREMENTS | | NOTES 297 PERSONS. CLARIFY. | | 5) THE WATER FILTRATION SYSTEM SHALL BE PROTECTED | | AGAINST CONTAMINATION PER 2014 FBC SEC.608.3. | | 6) SUBMIT FACTORY SIZING CALCULATIONS FOR THE GREASE | | TRAP & GREASE INTERCEPTOR. YOU CAN CONTACT LEE | | SCHNEEWEISS WITH SCHIER AT 1-800-538-4792. 2014 | | FBC-PLUMBING SEC.1003.2. | | 7) IS THIS A CHANGE OF OCCUPANCY? INDICATE ON THE | | PLANS. IF SO, ADDITIONAL REVIEW COMMENTS MAY BE | | GENERATED. | | 8) SHT. A-7.3 - THE ACCESSIBLE URRINAL SHALL BE MOUNTED | | WITH THE RIM LOCATED AT 17 INCHES ABOVE FINISH FLOOR, | | NOT 1'-7" AS SHOWN. 2014 FAC SEC. 605.2. | | 9) GRAB BARS SHALL BE MEASURED TO THE TOP OF THE | | GRIPPING SURFACE PER THE 2014 FAC SEC. 609.4. | | 10) SHT. P5.1 - THE SANITARY RISER SHOWS AN UNVENTED | | SINK (SK-1) DRAINING INTO THE TOP OF THE | | INTERCEPTOR.CLARIFY. | | 11) THE DISCHARGE OF THE INTEERCEPTORS ARE SHOWN AS | | INDIRECCT WASTES ON BOTH INTERCEPTORS. CLARIFY.ALSO, | | CLARIFY THE INLET CONNECTION TO THE AUTOMATIC GREASE | | INTERCEPTOR. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
P |
Date |
2016-11-10 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2016-11-10 |
Time |
12:11 |
Rev Time |
1.00 |
Received By |
eschneid |
Date |
2016-11-10 |
Time |
09:09 |
Sent To |
|
|
Notes |
2016-11-10 12:12:03 | PASSED W/PROVISO | | | | 1) PROVISO: PRIOR TO FIRST INSPECTION, SUBMIT A | | REVISION TO SHEET A-6.0, VIA A PERMIT REVISION, WHICH | | INCLUDES THE PAINT MANUFACTURER, COLOR SELECTIONS AND | | LOCATIONS FOR THE EXTERIOR FACADE SO THAT STAFF CAN | | VERIFY COMPLIANCE WITH THE CITYPLACE DESIGN GUIDELINES. | | THE RESPONSE LETTER STATES THAT THE CURRENT SHEET A-6.0 | | INCLUDES THIS INFORMATION, YET IT DOES NOT.THE BRAND | | AND NAMES OF THE PAINT COLORS THAT YOU WILL BE USING. | | THE RESPONSE COMMENTS STATE THAT CITYPLACE APPROVED THE | | PAINT, BUT THE PLANS DID NOT INCLUDE THE SPECIFICS. | | | | 2) SEPARATE PERMITS, WITH PLANS REQUIRED FOR: | | | | A. AWNINGS - PLEASE NOTE: THE CITYPLACE MASTER SIGN | | PLAN REQUIRES THAT ALL AWNINGS AT STREET LEVEL REQUIRE | | AN EIGHT (8) INCH VALANCE, NOT THE SIX (6) INCHES AS | | SHOWN. COMPLIANCE WITH THIS STANDARD WILL BE VERIFIED | | AT THE TIME OF THE BUILDING PERMIT SUBMITTAL FOR THE | | AWNINGS. | | B. SIGNS | | C. EXTERIOR PAVER WORK | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
F |
Date |
2016-10-25 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2016-10-25 |
Time |
11:15 |
Rev Time |
1.00 |
Received By |
eschneid |
Date |
2016-10-25 |
Time |
10:01 |
Sent To |
|
|
Notes |
2016-10-25 11:15:29 | FAILED | | | | PLEASE PROVIDE RESPONSES TO THE FOLLOWING IN WRITING. | | | | 1) REVISED COMMENT: THE MAJORITY OF THE ARCHITECTURAL | | SHEETS WERE NOT UPDATED TO REFLECT THAT THE OKEECHOBEE | | BOULEVARD FACADE AND THE CORNER TOWER ARE REMAINING IN | | THE CURRENT CONFIGURATION. CORRECT ALL SHEETS TO | | ACCURATELY REFLECT THE SCOPE OF WORK. THE FOLLOWING | | SHEETS WERE NOT CORRECTED ? A-1.0, A-1.1, A-2.0, A-2.1, | | A-3.0, A-4.0, A-4.1, A-5.0, A-5.1, A-7.1, A-7.7, AND | | A-9.0. NOTE: THE LOCATIONS OF ITEMS SHOWN ON THE | | ELECTRIC SHEETS (LIGHTS, JUNCTION BOXES, ETC.) MAY BE | | IMPACTED BY THE FACADE REMAINING IN ITS CURRENT | | CONFIGURATION. | | | | 2) REPEAT COMMENT: PLEASE PROVIDE THE BRAND AND NAMES | | OF THE PAINT COLORS THAT YOU WILL BE USING. THE | | RESPONSE COMMENTS STATE THAT CITYPLACE APPROVED THE | | PAINT, BUT THE PLANS DID NOT INCLUDE THE SPECIFICS. | | | | 3) SEPARATE PERMITS, WITH PLANS REQUIRED FOR: | | | | A. AWNINGS - PLEASE NOTE THAT THE CITYPLACE MASTER SIGN | | PLAN REQUIRES THAT AWNINGS ON THE STREET LEVEL SHALL | | HAVE A MINIMUM CLEARANCE OF EIGHT (8) FEET FROM THE | | FINISHED FLOOR ELEVATION TO THE LOWEST POINT OF THE | | AWNING. THE SUBMITTED PLANS DO NOT VERIFY THIS | | REQUIREMENT. PLEASE BE AWARE THAT A GRADE CHANGE IS | | SHOWN ON OKEECHOBEE BOULEVARD, WHICH MAY AFFECT THIS | | REQUIREMENT. ADDITIONALLY, THE AWNINGS ARE SHOWN | | EXTENDING ONLY THREE (3) FEET FROM THE BUILDING, NOT | | THE FOUR (4) FEET REQUIRED BY THE CITYPLACE MASTER SIGN | | PLAN. THIS REQUIREMENT MAY BE WAIVED BY CITYPLACE | | RETAIL, IN WRITING, AT THE TIME OF THE BUILDING PERMIT | | SUBMITTAL FOR THE AWNINGS. | | B. SIGNS | | C. EXTERIOR PAVER WORK | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2016-10-04 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2016-10-04 |
Time |
11:24 |
Rev Time |
1.00 |
Received By |
eschneid |
Date |
2016-09-30 |
Time |
09:31 |
Sent To |
|
|
Notes |
2016-10-04 11:26:00 | FAILED | | | | PLEASE PROVIDE RESPONSES TO THE FOLLOWING IN WRITING. | | | | 1) THE DEMOLITION PLAN (SHEET A-0.0) WAS NOT UPDATED | | AND STILL SHOWS THE DEMOLITION OF THE DOORWAY AND | | WINDOWS ON THE OKEECHOBEE BOULEVARD FA?ADE AND THE | | CORNER TOWER ELEMENT. THE MAJORITY OF THE ARCHITECTURAL | | SHEETS WERE NOT UPDATED TO REFLECT THAT THE OKEECHOBEE | | BOULEVARD FA?ADE AND THE CORNER TOWER ARE REMAINING IN | | THE CURRENT CONFIGURATION. PROVIDE A REVISED DEMOLITION | | PLAN AND UPDATE ALL SHEETS TO ACCURATELY REFLECT THE | | SCOPE OF WORK. | | | | 2) PLEASE PROVIDE THE BRAND AND NAMES OF THE PAINT | | COLORS THAT YOU WILL BE USING. THE RESPONSE COMMENTS | | STATE THAT CITYPLACE APPROVED THE PAINT, BUT THE PLANS | | DID NOT INCLUDE THE SPECIFICS. | | | | 3) SEPARATE PERMITS, WITH PLANS REQUIRED FOR: | | | | A. AWNINGS - PLEASE NOTE THAT THE CITYPLACE MASTER SIGN | | PLAN REQUIRES THAT AWNINGS ON THE STREET LEVEL SHALL | | HAVE A MINIMUM CLEARANCE OF EIGHT (8) FEET FROM THE | | FINISHED FLOOR ELEVATION TO THE LOWEST POINT OF THE | | AWNING. THE SUBMITTED PLANS DO NOT VERIFY THIS | | REQUIREMENT. PLEASE BE AWARE THAT A GRADE CHANGE IS | | SHOWN ON OKEECHOBEE BOULEVARD, WHICH MAY AFFECT THIS | | REQUIREMENT. ADDITIONALLY, THE AWNINGS ARE SHOWN | | EXTENDING ONLY THREE (3) FEET FROM THE BUILDING, NOT | | THE FOUR (4) FEET REQUIRED BY THE CITYPLACE MASTER SIGN | | PLAN. THIS REQUIREMENT MAY BE WAIVED BY CITYPLACE | | RETAIL, IN WRITING, AT THE TIME OF THE BUILDING PERMIT | | SUBMITTAL FOR THE AWNINGS. | | B. SIGNS | | C. EXTERIOR PAVER WORK | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2016-08-16 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2016-08-16 |
Time |
08:33 |
Rev Time |
1.00 |
Received By |
eschneid |
Date |
2016-08-15 |
Time |
09:08 |
Sent To |
|
|
Notes |
2016-08-16 09:01:52 | FAILED | | | | PLEASE PROVIDE RESPONSES TO THE FOLLOWING IN WRITING. | | | | 1) REPEAT COMMENT: PRIVACY WINDOW FILM IS NOT | | PERMITTED. THE EXTERIOR ELEVATION SHEET A-6.0 HAS NOT | | BEEN REVISED TO REFLECT THE REMOVAL OF THE WINDOW FILM | | AS SHOWN ON SHETS AN-4.2 AND A-4.1. ALL PLANS SHALL | | SHOW THE SAME CONDITIONS. | | | | 2) SECTION K.4(H) OF THE CITYPLACE MASTER SIGN PLAN | | STATES THAT AWNINGS SHALL BE A SUNBRELLA 100% SOLUTION | | DYED ACRYLIC OR SUNBRELLA FIRESIST 100% SOLUTION DYED | | MODACRYLIC MATERIAL. WOODEN AWNINGS ARE NOT PERMITTED. | | THE CITYPLACE MASTER SIGN PLAN, INCLUDING THE AWNING | | PROVISIONS, WERE ADOPTED AFTER THE WOODEN AWNINGS WERE | | INSTALLED AT IMPROV; THEREFORE, THAT EXAMPLE IS NOT | | APPLICABLE FOR THE UTILIZATION OF WOODEN AWNINGS. | | | | 3) THE EXTERIOR ELEVATIONS SHALL EITHER SHOW THE ACTUAL | | PROPOSED AWNINGS OR NO AWNINGS WITH A NOTE THAT THE | | AWNINGS WILL BE PERMITTED AT A FUTURE DATE. THE | | ELEVATIONS MAY NOT INCLUDE NON-COMPLIANT AWNINGS OR | | AWNINGS THAT ARE NOT BEING PLANNED. | | | | 4) SHEET A-8.10 WAS NOT UPDATED AND SHOWS OBSOLETE | | AWNING DETAILS. IF THE AWNING DETAILS ARE PROVIDED AS | | REFERENCE, THEY SHALL SHOW THE ACCURATE AWNINGS THAT | | COMPLY WITH THE CITY PLACE MASTER SIGN PLAN. | | | | 5) BASED ON THE MEETING ON 8/19/16 WITH THE CAPITAL ONE | | TEAM AND RELATED, THE AGREEMENT IS: | | A. NO CHANGES TO OKEECHOBEE BLVD. FACADE OTHER THAN | | AWNINGS AND/OR PAINT. | | B. THE CORNER TOWER ELEMENT ON ROSEMARY WILL REMAIN THE | | SAME OR ONLY HAVE AWNINGS REMOVED. | | C. THE RECESSED AREA ON ROSEMARY MAY HAVE THE NEW | | LARGER GLAZED OPENINGS, WHILE RESPECTING THE "DEPTH" | | REQUIREMENT. | | D. PAINT OR SCORED STUCCO IS PERMITTED IN THE RECESSED | | AREA. | | E. THE NORTHERNMOST PROTRUDING "TOWER" ELEMENT SHALL | | HAVE A DIFFERENT TREATMENT THAN THE RECESSED AREA. | | | | 6) SEPARATE PERMITS, WITH PLANS REQUIRED FOR: | | | | A. AWNINGS | | B. SIGNS | | C. EXTERIOR PAVER WORK | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2016-06-15 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2016-06-15 |
Time |
11:13 |
Rev Time |
1.50 |
Received By |
eschneid |
Date |
2016-06-07 |
Time |
16:46 |
Sent To |
|
|
Notes |
2016-06-15 11:14:57 | FAILED | | | | PLEASE PROVIDE RESPONSES TO THE FOLLOWING IN WRITING. | | | | 1) THE PERMIT PLANS SHOW OUTDOOR SEATING. PLEASE | | PROVIDE TWO COPIES OF A SURVEY WHICH SHOWS THE | | DIMENSION FROM THE BUILDING FACE TO THE SOUTH ROSEMARY | | AVENUE RIGHT-OF-WAY AND ANY EASEMENTS THAT ARE WITHIN | | THIS AREA. | | | | 2) PRIVACY WINDOW FILM IS NOT PERMITTED. THE WINDOWS | | SHALL MAINTAIN THE TRANSPARENCY. YOU MAY INSTALL BLINDS | | BEHIND THE WINDOW TO PROVIDE PRIVACY. | | | | 3) THE PROPOSED CAPITAL ONE CAFE IS LOCATED AT THE | | ROSEMARY AVENUE PORTAL AS DESCRIBED IN THE CITYPLACE | | MASTER DESIGN GUIDELINES. THIS AREA IS TO HAVE | | DISTINCTIVE ARCHITECTURAL ELEMENTS TO FRAME THE | | ENTRANCE TO ROSEMARY AVENUE. THE PROPOSED ELEVATIONS | | SHOW THE REMOVAL OF THE DISTINCTIVE STONEWORK ELEMENTS | | WHICH FRAME THE DOORWAYS AT THE CORNER OF OKEECHOBEE | | BOULEVARD AND ROSEMARY AVENUE. THESE ARCHITECTURAL | | ELEMENTS PROVIDE THE DETAILING TO PROVIDE THE VISUAL | | INTEREST MANDATED BY THE DESIGN GUIDELINES. STAFF DOES | | NOT SUPPORT THE REMOVAL OF THESE ARCHITECTURAL | | ELEMENTS. | | | | 4) IN ORDER TO MAINTAIN THE ARCHITECTURAL VARIATION | | ALONG THE FACADES THAT PROVIDES VISUAL INTEREST, THE | | RECESSED AREAS ALONG THE FACADES (AROUND THE WINDOWS) | | SHALL STAY SMOOTH STUCCO PAINTED IN THE MEDITERRANEAN | | COLOR PALLET. PLEASE PROVIDE THE COLOR YOU PROPOSE TO | | USE. | | | | 5) THE PROTRUDING WALL WHERE THE PROPOSED WINDOW, | | FURTHEST NORTH ALONG ROSEMARY AVENUE, IS PROPOSED TO BE | | COVERED WITH NEW CEMENT PLASTER PANELS. PLEASE PROVIDE | | A DESCRIPTION, TO INCLUDE COLOR, OF THESE PANELS. | | | | 6) THE DESIGN GUIDELINES REQUIRE THAT THE DESIGN | | CHARACTER BE IN THE HISTORICAL MEDITERRANEAN STYLE. AS | | SUCH, THE PROPOSED WINDOWS ARE LARGER IN PROPORTION | | RELATIVE TO THE WALL AREA THAN IS TYPICALLY FOUND IN | | THE HISTORICAL MEDITERRANEAN STYLE. PLEASE REVIEW THE | | FACADE DESIGN. PLEASE NOTE THAT THE DESIGN GUIDELINES | | REQUIRE THAT LARGER GLASS AREAS SHOULD BE RECESSED OR | | OTHERWISE SHADED. ARCHES ABOVE THESE WINDOWS AS WELL AS | | ADDITIONAL FRAMING OF THE WINDOWS COULD RESULT IN | | COMPLIANCE WITH THE DESIGN GUIDELINES. | | | | 7) PLEASE PROVIDE SIGHT LINE DETAILS TO VERIFY THAT ANY | | NEW ROOF MOUNTED EQUIPMENT IS SCREENED FROM PUBLIC | | VIEW. THE FULL HEIGHT DIMENSION OF THE EQUIPMENT PLUS | | THE CURB/RACK SHALL BE SHOWN. | | | | 8) SEPARATE PERMITS, WITH PLANS REQUIRED FOR: | | | | A. AWNINGS. PLEASE NOTE THAT THE FLAT AWNINGS ARE NOT | | PERMITTED TO EXTEND PAST THE CORNER TOWER ELEMENT ALONG | | SOUTH ROSEMARY AVENUE AND THE FLAT AWNINGS MAY NOT BE | | MADE OF METAL. | | B. SIGNS | | C. EXTERIOR PAVER WORK. PLEASE NOTE THAT IF ANY WORK IS | | IN THE RIGHT-OF-WAY (VERIFIED WITH THE SURVEY) THEN | | THAT PORTION OF THE WORK WILL REQUIRE A RIGHT-OF-WAY | | PERMIT. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | |
|
|