Plan Review Details - Permit 16051208
Plan Review Stops For Permit 16051208
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-10-12 Cont ID  
Sent By jgomez Date 2016-10-12 Time 07:55 Rev Time 0.00
Received By jgomez Date 2016-10-12 Time 07:51 Sent To  
Notes
2016-10-12 08:04:3210-11-16 MET WITH MR. & MRS. KENNEDY (OWNER'S) TO GO
 OVER REVIEWS. THEY NEED TO GET PERMIT. THEY SAID BANK
 MAY FORECLOSURE THEIR HOUSE IF THEY DON'T START WORK. I
 OFFER THEM TO ISSUE PERMIT WITH PROVISO. TOLD THEM
 REVISION FEES WILL APPLY. THEY AGREED.
  
 REAR STRUCTURE:
 BUILDING REVIEW APPROVED WITH PROVISO (NOTE: SUBMIT
 REVISIONS PRIOR TO INSPECTIONS TO AVOID
 CONFLICTS/DELAYS):
  
 1- PROVIDE COMPLETE ENGINEER'S STRUCTURAL DETAILS AND
 SPECIFICATIONS FOR THE STRUCTURAL REPAIRS. SEC. R301.1
 FBC-RESIDENTIAL.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-08-29 Cont ID  
Sent By jgomez Date 2016-08-29 Time 17:26 Rev Time 0.00
Received By jgomez Date 2016-08-29 Time 17:17 Sent To  
Notes
2016-08-29 17:30:55REAR STRUCTURE:
 RESIDENTIAL (R3) ALTERATION SECOND BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014)
  
 ORIGINAL COMMENT:
 1- SCOPE OF WORK IS NOT CLEAR. CLEARLY SPECIFY EXTENT
 OF WORK TO BE PERFORMED. SPECIFY WHAT'S NEW , WHAT'S
 EXISTING, ETC. SEC. 107.2.1 CITY CITY AMENDMENTS.
  
 RESPONSE:
 (1) SCOPE BUILDING NOTE #2 STATES "REPAIR DAMAGED
 EXISTING FRAMING AND LAPPED SIDING ON EXISTING EXTERIOR
 WALL, TO MATCH EXISTING". NEED TO IDENTIFY REPAIR AREAS
 AND PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 STRUCTURAL REPAIRS. CLEARLY SPECIFY ALL FRAMING MEMBERS
 AND CONNECTORS. SEC. R301.1 FBC-RESIDENTIAL, 5TH
 EDITION (2014).
  
 (2) SCOPE OF WORK SHOWN ON FP-1 DRAWING DOESN'T MATCH
 SCOPE OF WORK SHOWN ON DRAWING FP-1 SUBMITTED UNDER THE
 MAIN HOUSE PERMIT #16051207. REVISE ALL SCOPE OF WORK
 TO MATCH. SEC. 107.2.1 CITY AMENDMENTS.
  
 ORIGINAL COMMENT:
 2- PROVIDE THE NAME AND SIGNATURE IN ALL PLANS OF THE
 PERSON RESPONSIBLE FOR THE DESIGN AS REQUIRED BY SEC.
 107.2.1 CITY AMENDMENTS.
  
 RESPONSE:
 STILL MISSING THE NAME OF THE PERSON RESPONSIBLE FOR
 THE DESIGN.
  
 3- IF THE ENTRY DOOR OF THE FIRST FLOOR IS GOING TO BE
 REPLACED, THEN PROVIDE PRODUCT APPROVAL (2 COPIES) AS
 REQUIRED BY FAC 61G20-3.002(33).
  
  
 **** PLEASE REMOVE ANY REVISED DRAWING AND INSERT THE
 NEW DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD
 DRAWINGS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-07-05 Cont ID  
Sent By jgomez Date 2016-07-05 Time 12:46 Rev Time 0.00
Received By jgomez Date 2016-07-01 Time 18:26 Sent To  
Notes
2016-07-05 13:47:24RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW
 COMMENTS.
 CODE: FBC 5TH EDITION (2014)
  
 1- ACCORDING TO PALM BEACH COUNTY PROPERTY APPRAISER,
 THE FIRST FLOOR IS UNFINISHED STORAGE. THERE ARE NO
 CITY RECORDS FOR THE CONSTRUCTION OF AN APARTMENT AS
 SHOWN ON PLANS SUBMITTED. IN ADDITION ZONING DOESN'T
 ALLOW ANOTHER APARTMENT. ZONING MAY ALLOW ADDITIONAL
 LIVABLE AREA BUT NO AN INDEPENDENT APARTMENT. AFTER THE
 PLANS ARE REVISED, BRING PLANS TO PALM BEACH COUNTY
 (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. BRING
 BACK COUNTY STAMPED PLANS AND COPY OF PAID RECEIPT IF
 FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF THE
 UNIFIED LAND DEVELOPMENT CODE.
  
 2- FIRST FLOOR PLAN LAYOUT AND SECOND FLOOR PLAN LAYOUT
 ARE EXACTLY THE SAME BUT THE NAMES OF THE ROOMS ARE
 DIFFERENT. THE PROPOSED USE AND OCCUPANCY OF THE FIRST
 FLOOR IS NOT CLEAR. FOR EXAMPLE, THE LAYOUT SHOWS A
 ROOM WITH A CLOSET AND A BATHROOM, BUT IT IS CALLED
 "ENTERTAINMENT ROOM". THIS IS GENERALLY USED AS A
 BEDROOM AS SHOWN ON THE SECOND FLOOR PLAN. (PLAN REVIEW
 WILL BE DONE BASED ON THE BEDROOM USE). THE LAYOUT ALSO
 SHOWS A KITCHEN AND A LIVING ROOM, BUT IT IS CALLED
 "EXERCISE, RECREATIONAL & ENTERTAINMENT ROOM". THIS IS
 GENERALLY USED AS KITCHEN AND LIVING ROOM AS SHOWN ON
 THE SECOND FLOOR PLAN. ALSO, THE ELECTRICAL FLOOR PLANS
 SHOW TWO SEPARATE METERS. CLARIFY, WHY PROVIDING TWO
 SEPARATE METERS IF ONLY ONE UNIT IS ALLOWED. NOTE:
 ELECTRICAL MAY MAY NEED TO BE REVISED.
 FOR YOUR INFORMATION ZONING MAY ALLOW THE CONVERSION OF
 THE FIRST FLOOR FROM STORAGE TO LIVABLE SPACE WITH SOME
 RESTRICTIONS. COORDINATE WITH ZONING FOR ALLOWED USE.
 CLEARLY DEFINE THE USE AND OCCUPANCY OF EACH ROOM TO
 PERFORM A PROPER PLAN REVIEW. REVISE PLANS AS REQUIRED
 TO VERIFY COMPLIANCE WITH THE PROPOSED USE AND
 OCCUPANCY. SEC. 102.2 CITY AMENDMENTS.
  
 3- COORDINATE WITH ITEM #3 ABOVE AND PROVIDE COMPLIANCE
 WITH THE EGRESS REQUIREMENTS OF THE BEDROOM ON THE
 FIRST FLOOR PLAN. SPECIFY WINDOW TYPE, SIZE. SEC. R310
 FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 4- SCOPE OF WORK IS NOT CLEAR. CLEARLY SPECIFY EXTENT
 OF WORK TO BE PERFORMED. SPECIFY WHAT'S NEW , WHAT'S
 EXISTING, ETC. SEC. 107.2.1 CITY CITY AMENDMENTS.
  
 5- SECOND FLOOR PLAN IS NOT DRAWN CORRECTLY. IT IS
 CONFUSING. IT SHOWS THE APARTMENT ENTRY DOOR THAT IS
 LOCATED ON THE FIRST FLOOR PLAN. REVISE AS REQUIRED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 6- PROVIDE THE NAME AND SIGNATURE IN ALL PLANS OF THE
 PERSON RESPONSIBLE FOR THE DESIGN AS REQUIRED BY SEC.
 107.2.1 CITY AMENDMENTS.
  
 7- THIS HOUSE IS A CONTRIBUTING HISTORIC HOUSE. IT IS
 EXEMPT FROM THE ENERGY CODE. ENERGY CALCULATIONS ARE
 NOT REQUIRED, BUT IF CONTRACTOR WANTS TO SUBMIT THEM,
 THEN REVISE THE FOLLOWING:
 A) CLARIFY WHY SUBMITTING ONE ENERGY CALCULATIONS PER
 FLOOR. SEC. 107.2.1 CITY AMENDMENTS.
  
 B) OWNER INFORMATION IS INCORRECT. SEC. R101.5.1.1.2
 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
  
 C) THE PERMIT OFFICE IS INCORRECT. THE PERMIT OFFICE IS
 CITY OF WEST PALM BEACH NOT PALM BEACH. TWO DIFFERENT
 MUNICIPALITIES. SEC. R101.5.1.1.2 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
  
 D) SPECIFY THE JURISDICTION NUMBER. SEC. R101.5.1.1.2
 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
  
 E) THIS IS NOT AN ADDITION. SEE PLANS. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
  
 F) NUMBER OF BEDROOMS IS INCORRECT. SEC. R101.5.1.1.2
 FBC-ENERGY CONSERVATION, 5TH EDITION (2014). NOTE: THIS
 APPLIES TO THE ENERGY CALCULATIONS OF THE 1ST FLOOR.
 COORDINATE WITH REVISED PLANS AS REQUIRED BY ITEM #2
 ABOVE.
  
 G) CONDITIONED FLOOR AREA IS INCORRECT. IT DOESN'T
 MATCH PLANS. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION,
 5TH EDITION (2014).
  
 H) PROVIDE MANUFACTURER'S DOCUMENTATION SHOWING THE
 DOORS AND WINDOWS U-FACTOR AND SHGC FACTOR SPECIFIED ON
 ITEM #7. SEC. R405.4.3 FBC-ENERGY CONSERVATION, 5TH
 EDITION (2014).
  
 I ) THE FLOOR TYPE AND INSULATION R-VALUE (ITEM #8) FOR
 THE SECOND FLOOR ENERGY CALCULATIONS IS INCORRECT.
 THERE IS NOT SLAB ON GRADE FOR THE SECOND FLOOR. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
  
 J) PROVIDE MANUFACTURER'S INFORMATION SHOWING HOW
 PROVIDING R-19 INSULATION ON THE WALLS. CHECK THICKNESS
 OF WALL AND THICKNESS OF PROPOSED INSULATION. SEC.
 R405.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
  
 K) CLARIFY HOW THE CEILING OF THE FIRST FLOOR ENERGY
 CALCULATIONS IS VENTED AS SPECIFIED ON ITEM #10. SEC.
 R405.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
  
 L) PROVIDE THE NAME OF THE PERSON PREPARING THE ENERGY
 CALCULATIONS AS REQUIRED BY SEC. R405.4.2 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
  
 M) OWNER/AGENT TO CERTIFY AND DATE THE ENERGY
 CALCULATIONS AT THE BOTTOM OF THE FORM AS REQUIRED BY
 SEC. R103.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
  
 N) PAGE 2 OF 4 OF THE ENERGY CALCULATIONS FOR THE FIRST
 FLOOR SPECIFY THAT THERE IS A KITCHEN. FIRST FLOOR IS
 NOT ALLOWED TO HAVE A KITCHEN. SEE ZONING COMMENTS.
 COORDINATE WITH REVISED PLANS AND REVISE CALCULATIONS
 AS REQUIRED. SEC. R103.2 FBC-ENERGY CONSERVATION, 5TH
 EDITION (2014).
  
 O) ROOFING MATERIAL SHOWN ON PAGE 2 OF 4 IS INCORRECT.
 ACCORDING TO CITY RECORDS THE LAST ROOFING PERMIT
 APPLICATION FOR THE REAR STRUCTURE WAS FOR SHINGLES NOT
 BARREL TILE. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION,
 5TH EDITION (2014).
  
 P) WINDOWS OVERHANG SEPARATION SHOWN ON PAGE 2 OF 4 IS
 INCORRECT. IT DOESN'T MATCH PLANS. SEC. R101.5.1.1.2
 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
  
 **** PLEASE REMOVE ANY REVISED DRAWING AND INSERT THE
 NEW DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD
 DRAWINGS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2016-10-12 Cont ID  
Sent By mvaldes Date 2016-10-12 Time 11:40 Rev Time 0.00
Received By mvaldes Date 2016-10-12 Time 11:34 Sent To  
Notes
2016-10-12 11:40:23REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
 PASSED WITH THE FOLLOWING PROVISO'S ( RED LINED )
  
 1] AFCI PROTECTION REQUIRED PER NEC 210.12(B)
  
 2] TAMPER RESISITANT RECEPTACLES REQUIRED PER NEC
 406.12
  
 3] SMOKE ALARMS REQUIRED PER FBC-R 314 & 315
  
 4] LABEL METER ENCLOSURE "METER MAIN" TO COMPLY WITH
 NEC 230.70[A][1] DISCONNECTING MEANS OF SERVICE
 CONDUCTORS SHALL BE LOCATED AT A READILY ACCESSIBLE
 LOCATION NEAREST THE POINT OF ENTRANCE.
  
 5] CORRECT GROUNDING DETAILS TO A # 4 CU ELECTRODE
 CONDUCTOR PER TABLE NEC 250.66 AND ADD AN INTERSYSTEM
 BONDING TERMINAL IN ACCORDANCE WITH NEC 250.94
  
 6] OVERCURRENT DEVICES SHALL NOT BE LOCATED IN THE
 VICINITY OF EASILY IGNITIBLE MATERIAL, SUCH AS IN
 CLOTHES CLOSETS. RELOCATE PANEL ON SECOND FLOOR AND
 PROVIDE PROPER WORKING CLEARANCE FOR THE FIRST FLOOR
 PANEL. NEC 240.21(2)(D) & FBC-R_E3405 WORKING CLEARANCE
 3' ?
  
 7] PLEASE TRY TO DARKEN IN THE ELECTRICAL POINTS ON THE
 FLOOR PLAN FOR THE QUALITY OF THE EXAMINER REVIEW.
 FBC-107 MINIMUM PLAN REVIEW
  
 - PERMIT # 16051208, 523 28TH STREET WPB FLORIDA. [
 REAR BUILDING ]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2016-08-17 Cont ID  
Sent By mvaldes Date 2016-08-17 Time 13:59 Rev Time 0.00
Received By mvaldes Date 2016-08-17 Time 13:59 Sent To  
Notes
2016-08-17 14:05:42REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
 1) ORIGINAL PLANS WERE PASSED WITH SEVERAL PROVISO'S
 THAT WEREN'T ADDRESSED IN THE 2ND SUBMITTAL PLEASE ADD
 THE FOLLOWING NOTES:
 1A) AFCI PROTECTION REQUIRED PER NEC 210.12[B]
 1B) TAMPER RESISITANT RECEPTACLES REQUIRED PER NEC
 406.12
 1C) SMOKE ALARMS REQUIRED PER FBC-R 314 & 315
  
 2) LABEL METER ENCLOSURE "METER MAIN" TO COMPLY WITH
 NEC 230.70[A][1] DISCONNECTING MEANS OF SERVICE
 CONDUCTORS SHALL BE LOCATED AT A READILY ACCESSIBLE
 LOCATION NEAREST THE POINT OF ENTRANCE.
  
 3) CORRECT GROUNDING DETAILS TO A # 4 CU ELECTRODE
 CONDUCTOR PLUS AUGMENTATE A ROD OR COMPLY WITH PROVING
 25 OHMS TO GROUND. NEC 250.56. ADD AN INTERSYSTEM
 BONDING TERMINAL IN ACCORDANCE WITH NEC 250.94
  
 4) OVERCURRENT DEVICES SHALL NOT BE LOCATED IN THE
 VICINITY OF EASILY IGNITIBLE MATERIAL, SUCH AS IN
 CLOTHES CLOSETS. RELOCATE PANEL ON SECOND FLOOR AND
 PROVIDE PROPER WORKING CLEARANCE FOR THE FIRST FLOOR
 PANEL. NEC 240.21[D] & 110.26
  
 5) PLEASE TRY TO DARKEN IN THE ELECTRICAL POINTS ON THE
 FLOOR PLAN FOR THE QUALITY OF THE EXAMINER REVIEW.
 FBC-107 MINIMUM PLAN REVIEW
  
 - PERMIT # 16051208, 523 28TH STREET WPB FLORIDA. [
 REAR BUILDING ]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-07-06 Cont ID  
Sent By mvaldes Date 2016-06-16 Time 17:50 Rev Time 0.00
Received By mvaldes Date 2016-06-16 Time 17:20 Sent To  
Notes
2016-06-16 17:51:46REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
 - FAILED WITH RED STAMPED COMMENTS MARKED ON PLANS.
  
 - ACCORDING TO ZONING YOUR ONLY PERMITTED TO METER ONE
 UNIT IN THE BACK SO ELIMANATE THE 2 METER STACK TO
 MATCH RISER DIAGRAM FOR INDIVIDUAL METERING.
  
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2016-09-13 Cont ID  
Sent By gjohnson Date 2016-09-13 Time 06:47 Rev Time 0.00
Received By gjohnson Date 2016-09-13 Time 06:47 Sent To  
Notes
2016-09-13 06:48:04GAS PLAN REVIEW
 A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE
 REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK.
 PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT
 SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE
 SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC.
 107.2.1.
  
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE
 FBC-R, SEC. G2404.3.
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL
 GAS SEC. 301.3.
  
 A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION.
  
 GAS PERMIT APPLICATION REQUIREMENTS
  
 EFFECTIVE IMMEDIATELY THE FOLLOWING INFORMATION SHALL
 BE SHOWN ON ALL GAS DRAWINGS SUBMITTED FOR PERMITTING
 IN THE CITY OF WEST PALM BEACH:
  
 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL
 CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS PER
 FBC-2014 FUEL GAS, SECS. 402.4.1, 402.4.2.
  
 2. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL
 PIPE SIZES, AND THE EHD NUMBER OF CORRUGATED STAINLESS
 STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. WPB
 AMENDMENTS TO FBC SEC. 107.2.1.
  
 3. TYPE OF GAS, (LP OR NATURAL).
  
 4. BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD ON
 THE SYSTEM. REFER TO THE FBC-2014 FUEL GAS SECS. 401.8
 THRU 402.6.1 AND TABLES 402.4(1) THRU 402.4(37).
  
 5. SHOW THE DISTANCE FROM THE POINT OF DELIVERY,
 (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING
 AND/OR SYSTEM PER THE FBC-2014 FUEL GAS APPENDIX A ?
 USE OF CAPACITY SECTION A.3.1(4) & 2014 FUEL GAS CODE
 SEC. 402.4.1.
  
 6. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE
 FBC-2014 FUEL GAS CODE SEC. 304.
  
 7. INDICATE THE DELIVERY PRESSURE (PSI) PER FBC-2014
 FUEL GAS SEC. 402.2. IF NATURAL GAS SPECIFY .5 PSI OR 2
 PSI.
  
 8. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND
 TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE
 SEC. 502 THRU 505.
  
 9. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL
 GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA
 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2
  
 10. CLEARLY SHOW THE LOCATION AND CAPACITY OF LP
 TANK(S), TYPE OF TANK (DOT OR ASME), THE DISTANCE OF
 THE TANK FROM THE BUILDING AND ADJACENT PROPERTY LINES
 THE DISTANCE OF THE TANK FROM ALL SOURCES OF IGNITION,
 OTHER CONTAINERS, BUILDINGS, AND THE LOCATION OF ANY
 BUILDING OPENINGS BELOW THE RELIEF VALVE OF THE TANK
 PER NFPA 58, TABLE 3-2.2.2.
  
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2016-08-24 Cont ID  
Sent By destabro Date 2016-08-24 Time 15:39 Rev Time 0.00
Received By destabro Date 2016-08-24 Time 15:39 Sent To B
Notes
2016-08-24 15:41:378/24/16 - PER CONVERSATION WITH THE APPLICANT, WOOD
 SIDING WILL BE REPAIRED FIRST AND REPLACED ONLY IF
 DAMAGED BEYOND REPAIR, AND TWO SOUTH-FACING WINDOWS ON
 THE FIRST FLOOR OF THE ANCILLARY BUILDING WILL BE
 REPLACED WITH WHITE FRAME ALUMINUM IMPACT PRODUCTS WITH
 COLONIAL GRID, RAISED OGEE PROFILES. THE OTHER ORIGINAL
 WOOD WINDOWS ARE TO BE RESTORED.THIS IS A CONTRIBUTING
 PROPERTY TO THE OLD NORTHWOOD HISTORIC DISTRICT, AND
 THE PROPOSED WORK FOLLOWS THE DESIGN GUIDELINES FOR
 THIS DISTRICT. RETURNED TO BOX R30. DLE

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2016-06-01 Cont ID  
Sent By fmittner Date 2016-06-01 Time 15:19 Rev Time 0.00
Received By fmittner Date 2016-06-01 Time 15:19 Sent To  
Notes
2016-06-01 15:21:31NEED IMAGE OF EXISTING WINDOWS, CONFIRMATION OF FRAME
 COLOR, LITE PATTERN, LOW-E OR CLEAR GLASS.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-09-22 Cont ID  
Sent By cpuell Date 2016-09-22 Time 09:43 Rev Time 0.00
Received By cpuell Date 2016-08-12 Time 15:55 Sent To  
Notes
2016-08-15 15:56:13R30
 **TRAVELLING WITH 16051207**

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-07-05 Cont ID  
Sent By jgomez Date 2016-07-05 Time 12:46 Rev Time 0.00
Received By jgomez Date 2016-05-26 Time 10:32 Sent To  
Notes
2016-06-13 10:32:56BIN R03

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2016-08-29 Cont ID  
Sent By jgomez Date 2016-08-29 Time 17:18 Rev Time 0.00
Received By jgomez Date 2016-08-29 Time 17:18 Sent To  
Notes
2016-08-29 17:19:35$236.59 PAID. MU-2016-019990.
 SEE ELECTRICAL DRAWING E-1 UNDER MAIN HOUSE PERMIT
 #16051207 FOR COUNTY IMPACT FEES STAMP.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2016-07-05 Cont ID  
Sent By jgomez Date 2016-07-05 Time 13:58 Rev Time 0.00
Received By jgomez Date 2016-07-05 Time 13:58 Sent To  
Notes
2016-07-05 14:00:311- ACCORDING TO PALM BEACH COUNTY PROPERTY APPRAISER,
 THE FIRST FLOOR IS UNFINISHED STORAGE. THERE ARE NO
 CITY RECORDS FOR THE CONSTRUCTION OF AN APARTMENT AS
 SHOWN ON PLANS SUBMITTED. IN ADDITION ZONING DOESN'T
 ALLOW ANOTHER APARTMENT. ZONING MAY ALLOW ADDITIONAL
 LIVABLE AREA BUT NO AN INDEPENDENT APARTMENT. AFTER THE
 PLANS ARE REVISED, BRING PLANS TO PALM BEACH COUNTY
 (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. BRING
 BACK COUNTY STAMPED PLANS AND COPY OF PAID RECEIPT IF
 FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF THE
 UNIFIED LAND DEVELOPMENT CODE.
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2016-09-21 Cont ID  
Sent By jvalido Date 2016-09-21 Time 18:18 Rev Time 0.00
Received By jvalido Date 2016-09-21 Time 17:54 Sent To  
Notes
2016-09-21 17:55:28CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA
 BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION
  
 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS
  
 FLORIDA ENERGY CODE FBC 2014
  
 JORGE VALIDO
 WPB MECHANICAL INSPECTOR/PLANS EXAMINER
 [email protected]
 561-805-6716
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-06-16 Cont ID  
Sent By jvalido Date 2016-06-16 Time 16:18 Rev Time 0.00
Received By jvalido Date 2016-06-16 Time 16:14 Sent To  
Notes
2016-06-16 16:18:26CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA
 BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION
 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS
  
 (1) PROVIDE CFM VALUES FOR BATHROOM EXHAUST.
  
 FLORIDA ENERGY CODE FBC 2014
  
 (2) PROVIDE SIGNATURE OF OWNER/AGENT ON ENERGY
 CALCULATIONS FORM R405-2014

Review Stop P PLUMBING
Rev No 3 Status P Date 2016-10-12 Cont ID  
Sent By gjohnson Date 2016-10-12 Time 13:18 Rev Time 0.00
Received By gjohnson Date 2016-10-12 Time 13:18 Sent To  
Notes
2016-10-12 13:23:44APPROVED WITH PROVISO
  
 PROVIDE BEFORE FIRST INSPECTION
  
 A APPROVED BY BUILDING DEPARTMENT RISER DIAGRAM
 CONTAINING THE FOLLOWING:
  
 1.PLEASE PROVIDE A COMPLETE RISER DIAGRAM. SHOWING
 EXISTING AND NEW PIPING AND REFLECTING THE FLOOR PLAN.
 PER WPB AMEND TO FBC 107.3.5.3(11)
  
 2. SHOW EXISTING AND NEW PIPING AND NEW TANKLESS HEATER
 ON WATER RISER DIAGRAM. PER WPB AMEND TO FBC
 107.3.5.3(11)
  
 3. THE FOLLOWING FIXTURES NEED VENTS, MASTER BATH LAV ,
 KITCHEN SINK ,WASHING MACHINE . PER FBC RES P3101.2.1
  
 4. SHOW THE P-TRAPS ON THE SINKS, SHOWERS, TUBS AND
 WASHING MACHINE. PER WPB AMEND TO FBC 107.2.1
  
 5. A CLEAN OUT IS REQUIRED AT THE BASE OF THE SOIL
 STACK FROM THE SECOND FLOOR. PER FBC RES P3005.2.6
  
  
  
  
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2016-09-13 Cont ID  
Sent By gjohnson Date 2016-09-13 Time 06:16 Rev Time 0.00
Received By gjohnson Date 2016-09-13 Time 06:16 Sent To  
Notes
2016-09-13 06:16:552ND REVIEW
  
  
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
  
 PLUMBING COMMENTS: DUE TO NEW DRAWING BEING SUBMITTED
 THE FOLLOWING DEFICIENCIES IN THE PLANS WERE FOUND
  
 1.PLEASE PROVIDE A COMPLETE RISER DIAGRAM. SHOWING
 EXISTING AND NEW PIPING AND REFLECTING THE FLOOR PLAN.
 PER WPB AMEND TO FBC 107.3.5.3(11)
  
 2. SHOW EXISTING AND NEW PIPING AND NEW TANKLESS HEATER
 ON WATER RISER DIAGRAM. PER WPB AMEND TO FBC
 107.3.5.3(11)
  
 3. THE FOLLOWING FIXTURES NEED VENTS, MASTER BATH LAV ,
 KITCHEN SINK ,WASHING MACHINE . PER FBC RES P3101.2.1
  
 4. SHOW THE P-TRAPS ON THE SINKS, SHOWERS, TUBS AND
 WASHING MACHINE. PER WPB AMEND TO FBC 107.2.1
  
 5. A CLEAN OUT IS REQUIRED AT THE BASE OF THE SOIL
 STACK FROM THE SECOND FLOOR. PER FBC RES P3005.2.6
  
  
  
  
  
 NEW DRAWINGS SUBMITTED.
2016-08-29 17:26:30NEW DRAWINGS SUBMITTED.

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-06-09 Cont ID  
Sent By gjohnson Date 2016-06-09 Time 14:41 Rev Time 0.00
Received By gjohnson Date 2016-06-09 Time 14:41 Sent To  
Notes
2016-06-09 14:41:42REVIEW APPROVED BY GEORGE EARL

Review Stop Z ZONING
Rev No 2 Status P Date 2016-09-20 Cont ID  
Sent By awooten Date 2016-09-20 Time 11:52 Rev Time 0.00
Received By awooten Date 2016-09-16 Time 15:14 Sent To  
Notes
2016-09-20 11:52:04*****ZONING REVIEW********
  
 ONLY ONE UNIT PERMITTED IN ACCESSORY STRUCTURE.

Review Stop Z ZONING
Rev No 1 Status F Date 2016-07-05 Cont ID  
Sent By fmittner Date 2016-06-01 Time 15:19 Rev Time 0.00
Received By destabro Date 2016-07-05 Time 13:23 Sent To  
Notes
2016-06-01 15:19:27ONLY ONE UNIT PERMITTED IN ACCESSORY STRUCTURE.