Plan Review Stops For Permit 16051207 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2016-10-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-10-11 |
Time |
17:08 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-10-11 |
Time |
17:07 |
Sent To |
|
|
Notes |
2016-10-11 17:28:43 | 10-11-16 MET WITH MR. & MRS. KENNEDY (OWNER'S) TO GO | | OVER REVIEWS. THEY NEED TO GET PERMIT. THEY SAID BANK | | MAY FORECLOSURE THEIR HOUSE IF THEY DON'T START WORK. I | | OFFER THEM TO ISSUE PERMIT WITH PROVISO. TOLD THEM | | REVISION FEES WILL APPLY. THEY AGREED. | | | | | | MAIN HOUSE: | | BUILDING REVIEW APPROVED WITH PROVISO (NOTE: SUBMIT | | REVISIONS PRIOR TO INSPECTIONS TO AVOID | | CONFLICTS/DELAYS): | | 1- BEDROOM #1 NEEDS EGRESS OPENING THAT COMPLIES WITH | | SEC. R310 FBC-RESIDENTIAL. | | 2- PROVIDE COMPLETE ENGINEER'S STRUCTURAL DRAWINGS | | SHOWING ALL FRAMING PLANS AND SPECIFICATIONS. SEC. | | R301.1 FBC-RESIDENTIAL. NOTE: PLANS REQUIRED PRIOR TO | | ANY INSPECTION. | | 3- NEED CARBON MONOXIDE ALARMS WITHIN ALL BEDROOM AS | | REQUIRED BY SEC. R315 FBC- RESIDENTIAL. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2016-08-29 |
|
|
Cont ID |
|
Sent By |
destabro |
Date |
2016-08-29 |
Time |
13:19 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-08-29 |
Time |
13:37 |
Sent To |
|
|
Notes |
2016-08-29 13:37:59 | MAIN HOUSE: | | RESIDENTIAL (R3) ADDITION/ALTERATION SECOND BUILDING | | REVIEW CHECKLIST. | | CODE: FBC 5TH EDITION (2014) | | | | ORIGINAL COMMENT: | | 1- PROVIDE COMPLIANCE WITH THE EGRESS REQUIREMENTS OF | | BEDROOM #1 SHOWN ON THE FIRST FLOOR PLAN. SPECIFY | | WINDOW TYPE, SIZE AND SILL HEIGHT SEC. R310 | | FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | RESPONSE: | | THE EMERGENCY ESCAPE SHALL OPEN DIRECTLY INTO A PUBLIC | | WAY OR TO A YARD OR COURT THAT OPENS TO A PUBLIC WAY. | | SEE SEC. R310.1 FBC-RESIDENTIAL. THE DOORS SHOWN ON | | FLOOR PLAN DON'T COMPLY. THEY DON'T OPEN INTO A PUBLIC | | WAY OR YARD OR COURT THAT OPENS TO A PUBLIC WAY. REVISE | | PLANS AS REQUIRED. | | | | ORIGINAL COMMENT: | | 2- SCOPE OF WORK IS NOT CLEAR. CLEARLY SPECIFY EXTENT | | OF WORK TO BE PERFORMED. WHY SUBMITTING PRODUCT | | APPROVAL FOR SINGLE HUNG WINDOWS. WHAT'S NEW , WHAT'S | | EXISTING, ETC. SEC. 107.2.1 CITY CITY AMENDMENTS. | | | | RESPONSE: | | (1) SCOPE BUILDING NOTE #1 INDICATES "REPAIR DAMAGED | | EXISTING FRAMING AND STUCCO ON EXISTING EXTERIOR WALL". | | NEED TO INDICATE ON PLANS DAMAGED AREAS AND PROVIDE | | COMPLETE DETAILS AND SPECIFICATIONS FOR THE PROPOSED | | REPAIR. SPECIFY ALL FRAMING MEMBERS AND CONNECTORS. | | SEC. R301.1 FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | (2) SCOPE BUILDING NOTE #3 INDICATES "INSTALL NEW | | INTERIOR FRAMING TO CREATE NEW UPSTAIRS BATHROOM | | ATTACHED TO MASTER BEDROOM". PROVIDE COMPLETE FRAMING | | PLANS AND SPECIFICATIONS. SPECIFY ALL FRAMING MEMBERS | | AND CONNECTORS. SEC. R301.1 FBC-RESIDENTIAL, 5TH | | EDITION (2014). | | | | ORIGINAL COMMENTS: | | 3- SPECIFY CARBON MONOXIDE ALARMS FOR ALL BEDROOMS | | SHOWING COMPLIANCE WITH SEC. R315 FBC-RESIDENTIAL. | | | | RESPONSE: | | CARBON MONOXIDE ALARMS TO BE INCLUDED IN THE ORIGINAL | | DRAWING. CORRECTIONS BY HAND ON SUBMITTED COPIES ARE | | NOT ALLOWED. | | | | ORIGINAL COMMENT: | | 4- PROVIDE THE NAME AND SIGNATURE IN ALL PLANS OF THE | | PERSON RESPONSIBLE FOR THE DESIGN AS REQUIRED BY SEC. | | 107.2.1 CITY AMENDMENTS | | | | RESPONSE: | | STILL MISSING THE NAME OF THE PERSON RESPONSIBLE FOR | | THE DESIGN. | | | | **** PLEASE REMOVE ANY REVISED DRAWING AND INSERT THE | | NEW DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMITT OLD | | DRAWINGS FOR REFERENCE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-07-05 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-07-05 |
Time |
09:11 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-07-01 |
Time |
18:21 |
Sent To |
|
|
Notes |
2016-07-05 10:28:54 | RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW | | COMMENTS. | | CODE: FBC 5TH EDITION (2014) | | | | 1- ACCORDING TO PALM BEACH COUNTY PROPERTY APPRAISER, | | THE REAR PART OF THE HOUSE IS A FINISHED OPEN PORCH. | | THERE ARE NO CITY RECORDS FOR THE CONSTRUCTION OF OF | | BEDROOM #1 AS SHOWN ON PLANS SUBMITTED. AFTER THE PLANS | | ARE REVISED, BRING PLANS TO PALM BEACH COUNTY (2300 N. | | JOG RD.) FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY | | STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. | | COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED LAND | | DEVELOPMENT CODE. | | | | 2- PROVIDE COMPLIANCE WITH THE EGRESS REQUIREMENTS OF | | BEDROOM #1 SHOWN ON THE FIRST FLOOR PLAN. SPECIFY | | WINDOW TYPE, SIZE AND SILL HEIGHT SEC. R310 | | FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | 3- SCOPE OF WORK IS NOT CLEAR. CLEARLY SPECIFY EXTENT | | OF WORK TO BE PERFORMED. WHY SUBMITTING PRODUCT | | APPROVAL FOR SINGLE HUNG WINDOWS. WHAT'S NEW , WHAT'S | | EXISTING, ETC. SEC. 107.2.1 CITY CITY AMENDMENTS. | | | | 4- SECOND FLOOR PLAN IS NOT DRAWN CORRECTLY. IT IS VERY | | CONFUSING. IT SHOWS THE FLOOR LAYOUT OF THE FIRST FLOOR | | INSTEAD OF SHOWING THE ROOF TOPS. REVISE AS REQUIRED. | | SEC. 107.2.1 CITY AMENDMENTS. | | | | 5- SPECIFY CARBON MONOXIDE ALARMS FOR ALL BEDROOMS | | SHOWING COMPLIANCE WITH SEC. R315 FBC-RESIDENTIAL. | | | | 6- PROVIDE THE NAME AND SIGNATURE IN ALL PLANS OF THE | | PERSON RESPONSIBLE FOR THE DESIGN AS REQUIRED BY SEC. | | 107.2.1 CITY AMENDMENTS | | | | **** PLEASE REMOVE ANY REVISED DRAWING AND INSERT THE | | NEW DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMITT OLD | | DRAWINGS FOR REFERENCE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2016-10-12 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-10-12 |
Time |
11:15 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-10-12 |
Time |
10:46 |
Sent To |
|
|
Notes |
2016-10-12 11:15:38 | REVIEW 2014 5TH FBC ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | | | | | PASSED WITH THE FOLLOWING PROVISO'S ( RED-LINED ) | | | | 1] AFCI PROTECTION REQUIRED PER NEC 210.12(B) | | | | 2] TAMPER RESISITANT RECEPTACLES REQUIRED PER NEC | | 406.12 | | | | 3] SMOKE ALARMS REQUIRED PER FBC-R 314 & 315 | | | | 4] LABEL METER ENCLOSURE "METER MAIN" TO COMPLY WITH | | NEC 230.70[A][1] DISCONNECTING MEANS OF SERVICE | | CONDUCTORS SHALL BE LOCATED AT A READILY ACCESSIBLE | | LOCATION NEAREST THE POINT OF ENTRANCE. | | | | 5] CORRECT GROUNDING DETAILS TO A # 4 CU ELECTRODE | | CONDUCTOR PER TABLE NEC 250.66 AND ADD AN INTERSYSTEM | | BONDING TERMINAL IN ACCORDANCE WITH NEC 250.94 | | | | 4) CLARIFY PANEL LOCATION ? IS IT IN A CLOTHES CLOSET ? | | DOES THE WORKING SPACE HEIGHT SUFFICE THE 6.5' FROM | | FLOOR REQUIREMENT ? NEC 240.24(2)(D) & FBC-R SECTION | | E3405 WORKING CLEARANCE | | | | 5) PLEASE TRY TO DARKEN IN THE ELECTRICAL POINTS ON THE | | FLOOR PLAN FOR THE QUALITY OF THE EXAMINER REVIEW. | | FBC-107 MINIMUM PLAN REVIEW | | | | - PERMIT # 16051207, 523 28TH STREET WPB FLORIDA. [ | | FRONT BUILDING ] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2016-08-17 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-08-17 |
Time |
13:28 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-08-17 |
Time |
11:16 |
Sent To |
|
|
Notes |
2016-08-17 13:51:43 | REVIEW 2014 5TH FBC ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | | | 1) ORIGINAL PLANS WERE PASSED WITH SEVERAL PROVISO'S | | THAT WEREN'T ADDRESSED IN THE 2ND SUBMITTAL PLEASE ADD | | THE FOLLOWING NOTES: | | 1A) AFCI PROTECTION REQUIRED PER NEC 210.12[B] | | 1B) TAMPER RESISITANT RECEPTACLES REQUIRED PER NEC | | 406.12 | | 1C) SMOKE ALARMS REQUIRED PER FBC-R 314 & 315 | | | | 2) LABEL METER ENCLOSURE "METER MAIN" TO COMPLY WITH | | NEC 230.70[A][1] DISCONNECTING MEANS OF SERVICE | | CONDUCTORS SHALL BE LOCATED AT A READILY ACCESSIBLE | | LOCATION NEAREST THE POINT OF ENTRANCE. | | | | 3) CORRECT GROUNDING DETAILS TO A # 4 CU ELECTRODE | | CONDUCTOR PLUS AUGMENTATE A ROD OR COMPLY WITH PROVING | | 25 OHMS TO GROUND. NEC 250.56. ADD AN INTERSYSTEM | | BONDING TERMINAL IN ACCORDANCE WITH NEC 250.94 | | | | 4) CLARIFY PANEL LOCATION ? IS IT IN A CLOTHES CLOSET ? | | DOES THE WORKING SPACE HEIGHT SUFFICE THE 6.5' FROM | | FLOOR REQUIREMENT ? NEC 110.26 WORKING CLEARANCE & | | FBC-R SECTION E3405 | | | | 5) PLEASE TRY TO DARKEN IN THE ELECTRICAL POINTS ON THE | | FLOOR PLAN FOR THE QUALITY OF THE EXAMINER REVIEW. | | FBC-107 MINIMUM PLAN REVIEW | | | | - PERMIT # 16051207, 523 28TH STREET WPB FLORIDA. [ | | FRONT BUILDING ] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2016-06-16 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-06-16 |
Time |
17:18 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-06-16 |
Time |
16:54 |
Sent To |
|
|
Notes |
2016-06-16 17:18:43 | REVIEW 2014 5TH FBC ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | | | - PASSED WITH PROVISO COMMENTS MARKED ON PLANS. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2016-09-13 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-09-13 |
Time |
06:44 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-09-13 |
Time |
06:44 |
Sent To |
|
|
Notes |
2016-09-13 06:46:11 | GAS PLAN REVIEW | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | 107.2.1. | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | FBC-R, SEC. G2404.3. | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | GAS SEC. 301.3. | | | | A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION. | | | | | | | | | | GAS PERMIT APPLICATION REQUIREMENTS | | | | EFFECTIVE IMMEDIATELY THE FOLLOWING INFORMATION SHALL | | BE SHOWN ON ALL GAS DRAWINGS SUBMITTED FOR PERMITTING | | IN THE CITY OF WEST PALM BEACH: | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL | | CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS PER | | FBC-2014 FUEL GAS, SECS. 402.4.1, 402.4.2. | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL | | PIPE SIZES, AND THE EHD NUMBER OF CORRUGATED STAINLESS | | STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. WPB | | AMENDMENTS TO FBC SEC. 107.2.1. | | | | 3. TYPE OF GAS, (LP OR NATURAL). | | | | 4. BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD ON | | THE SYSTEM. REFER TO THE FBC-2014 FUEL GAS SECS. 401.8 | | THRU 402.6.1 AND TABLES 402.4(1) THRU 402.4(37). | | | | 5. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, | | (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING | | AND/OR SYSTEM PER THE FBC-2014 FUEL GAS APPENDIX A ? | | USE OF CAPACITY SECTION A.3.1(4) & 2014 FUEL GAS CODE | | SEC. 402.4.1. | | | | 6. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | FBC-2014 FUEL GAS CODE SEC. 304. | | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) PER FBC-2014 | | FUEL GAS SEC. 402.2. IF NATURAL GAS SPECIFY .5 PSI OR 2 | | PSI. | | | | 8. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE | | SEC. 502 THRU 505. | | | | 9. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | | | 10. CLEARLY SHOW THE LOCATION AND CAPACITY OF LP | | TANK(S), TYPE OF TANK (DOT OR ASME), THE DISTANCE OF | | THE TANK FROM THE BUILDING AND ADJACENT PROPERTY LINES | | THE DISTANCE OF THE TANK FROM ALL SOURCES OF IGNITION, | | OTHER CONTAINERS, BUILDINGS, AND THE LOCATION OF ANY | | BUILDING OPENINGS BELOW THE RELIEF VALVE OF THE TANK | | PER NFPA 58, TABLE 3-2.2.2. | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2016-08-22 |
|
|
Cont ID |
|
Sent By |
destabro |
Date |
2016-08-22 |
Time |
13:05 |
Rev Time |
0.00 |
Received By |
destabro |
Date |
2016-08-22 |
Time |
13:05 |
Sent To |
B |
|
Notes |
2016-08-22 13:19:06 | 8/22/16 - CONTRIBUTING PROPERTY TO THE OLD NORTHWOOD | | HISTORIC DISTRICT. REVISED PLANS FOR MAIN HOUSE INCLUDE | | THE REPAIR OF EXTERIOR STUCCO. APPLICANT MUST MAINTAIN | | EXISTING TEXTURED STUCCO APPEARANCE. WINDOW AND DOOR | | REPLACEMENT IS PROPOSED ONLY FOR ACCESSORY REAR | | STRUCTURE. DLE |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2016-06-01 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2016-06-01 |
Time |
11:11 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2016-06-01 |
Time |
11:07 |
Sent To |
|
|
Notes |
2016-06-01 14:46:14 | SAW ACCESSORY STRUCTURE IS UNDER SEPERATE PERMIT | | 16051208. SICNE THIS PERMIT FOR MAIN STRUCTURE | | INDICATES ONLY INTERIOR, HISOTRIC IS N/A | 2016-06-01 11:13:21 | PERMIT PACKET INDICATES WINDOW REPLACEMENT IN ACCESSORY | | STRUCTURE. NEED TO KNOW WHAT EXISTING WINDOWS ARE AND | | WHAT LITE PATTERN IS GOING IN, LIST FRAME COLOR AND | | CLEAR GLASS OR LOW-E NO TINT. QUESTIONS, CONTACT | | FRIEDERIKE MITTNER, CITY HSITORIC PRESERVATION PLANNER | | AT (561) 822-1457. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-09-22 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2016-09-22 |
Time |
09:43 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2016-08-12 |
Time |
15:53 |
Sent To |
|
|
Notes |
2016-08-15 15:53:50 | R30 | | **TRAVELLING WITH 16051208** |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-07-05 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-07-05 |
Time |
10:46 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-05-26 |
Time |
13:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2016-08-29 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-08-29 |
Time |
14:40 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-08-29 |
Time |
14:40 |
Sent To |
|
|
Notes |
2016-08-29 14:50:00 | $236.59 PAID. MU-2016 019990. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2016-07-05 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-07-05 |
Time |
10:32 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-07-05 |
Time |
10:32 |
Sent To |
|
|
Notes |
2016-07-05 10:32:45 | 1- ACCORDING TO PALM BEACH COUNTY PROPERTY APPRAISER, | | THE REAR PART OF THE HOUSE IS A FINISHED OPEN PORCH. | | THERE ARE NO CITY RECORDS FOR THE CONSTRUCTION OF OF | | BEDROOM #1 AS SHOWN ON PLANS SUBMITTED. AFTER THE PLANS | | ARE REVISED, BRING PLANS TO PALM BEACH COUNTY (2300 N. | | JOG RD.) FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY | | STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. | | COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED LAND | | DEVELOPMENT CODE. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
jvalido |
Date |
2016-09-21 |
Time |
17:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-06-15 |
|
|
Cont ID |
|
Sent By |
jvalido |
Date |
2016-06-15 |
Time |
11:58 |
Rev Time |
0.00 |
Received By |
jvalido |
Date |
2016-06-15 |
Time |
11:29 |
Sent To |
|
|
Notes |
2016-06-15 11:58:43 | CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA | | BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION | | | | 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1 | | INFORMATION ON CONSTRUCTION DOCUMENTS | | PROVIDE MECHANICAL PLANS. DIFFERENTIATE ALL NEW | | DUCTWORK FROM EXISTING DUCTWORK ON PLANS. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2016-10-12 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-10-12 |
Time |
13:30 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-10-12 |
Time |
13:30 |
Sent To |
|
|
Notes |
2016-10-12 13:30:57 | APPROVED WITH PROVISO | | | | PROVIDE BEFORE FIRST INSPECTION | | | | A APPROVED BY BUILDING DEPARTMENT RISER DIAGRAM | | CONTAINING THE FOLLOWING: | | | | 1.PLEASE PROVIDE A COMPLETE RISER DIAGRAM. SHOWING | | EXISTING AND NEW PIPING AND REFLECTING THE FLOOR PLAN. | | PER WPB AMEND TO FBC 107.3.5.3(11) | | | | 2. SHOW EXISTING AND NEW PIPING AND NEW TANKLESS HEATER | | ON WATER RISER DIAGRAM. PER WPB AMEND TO FBC | | 107.3.5.3(11) | | | | 3. THE FOLLOWING FIXTURES NEED VENTS, MASTER BATH LAV , | | KITCHEN SINK ,WASHING MACHINE . PER FBC RES P3101.2.1 | | | | 4. SHOW THE P-TRAPS ON THE SINKS, SHOWERS, TUBS AND | | WASHING MACHINE. PER WPB AMEND TO FBC 107.2.1 | | | | 5. A CLEAN OUT IS REQUIRED AT THE BASE OF THE SOIL | | STACK FROM THE SECOND FLOOR. PER FBC RES P3005.2.6 | | | | | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2016-09-13 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-09-13 |
Time |
06:06 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-09-12 |
Time |
16:21 |
Sent To |
|
|
Notes |
2016-09-13 06:06:43 | 2ND REVIEW | | | | | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | | | PLUMBING COMMENTS: DUE TO NEW DRAWING BEING SUBMITTED | | THE FOLLOWING DEFICIENCIES IN THE PLANS WERE FOUND | | | | 1.PLEASE PROVIDE A COMPLETE RISER DIAGRAM. SHOWING | | EXISTING AND NEW PIPING AND REFLECTING THE FLOOR PLAN. | | PER WPB AMEND TO FBC 107.3.5.3(11) | | | | 2. SHOW EXISTING AND NEW PIPING AND NEW TANKLESS HEATER | | ON WATER RISER DIAGRAM. PER WPB AMEND TO FBC | | 107.3.5.3(11) | | | | 3. THE FOLLOWING FIXTURES NEED VENTS, MASTER BATH LAV , | | KITCHEN SINK ,WASHING MACHINE . PER FBC RES P3101.2.1 | | | | 4. SHOW THE P-TRAPS ON THE SINKS, SHOWERS, TUBS AND | | WASHING MACHINE. PER WPB AMEND TO FBC 107.2.1 | | | | 5. A CLEAN OUT IS REQUIRED AT THE BASE OF THE SOIL | | STACK FROM THE SECOND FLOOR. PER FBC RES P3005.2.6 | | | | | | | | | | | 2016-08-29 14:04:37 | NEW DRAWINGS SUBMITTED. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2016-06-09 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-06-09 |
Time |
14:29 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-06-09 |
Time |
14:28 |
Sent To |
|
|
Notes |
2016-06-09 14:34:59 | REVIEW APPROVED BY GEORGE EARL |
|
|