Plan Review Details - Permit 16051207
Plan Review Stops For Permit 16051207
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-10-12 Cont ID  
Sent By jgomez Date 2016-10-11 Time 17:08 Rev Time 0.00
Received By jgomez Date 2016-10-11 Time 17:07 Sent To  
Notes
2016-10-11 17:28:4310-11-16 MET WITH MR. & MRS. KENNEDY (OWNER'S) TO GO
 OVER REVIEWS. THEY NEED TO GET PERMIT. THEY SAID BANK
 MAY FORECLOSURE THEIR HOUSE IF THEY DON'T START WORK. I
 OFFER THEM TO ISSUE PERMIT WITH PROVISO. TOLD THEM
 REVISION FEES WILL APPLY. THEY AGREED.
  
  
 MAIN HOUSE:
 BUILDING REVIEW APPROVED WITH PROVISO (NOTE: SUBMIT
 REVISIONS PRIOR TO INSPECTIONS TO AVOID
 CONFLICTS/DELAYS):
 1- BEDROOM #1 NEEDS EGRESS OPENING THAT COMPLIES WITH
 SEC. R310 FBC-RESIDENTIAL.
 2- PROVIDE COMPLETE ENGINEER'S STRUCTURAL DRAWINGS
 SHOWING ALL FRAMING PLANS AND SPECIFICATIONS. SEC.
 R301.1 FBC-RESIDENTIAL. NOTE: PLANS REQUIRED PRIOR TO
 ANY INSPECTION.
 3- NEED CARBON MONOXIDE ALARMS WITHIN ALL BEDROOM AS
 REQUIRED BY SEC. R315 FBC- RESIDENTIAL.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-08-29 Cont ID  
Sent By destabro Date 2016-08-29 Time 13:19 Rev Time 0.00
Received By jgomez Date 2016-08-29 Time 13:37 Sent To  
Notes
2016-08-29 13:37:59MAIN HOUSE:
 RESIDENTIAL (R3) ADDITION/ALTERATION SECOND BUILDING
 REVIEW CHECKLIST.
 CODE: FBC 5TH EDITION (2014)
  
 ORIGINAL COMMENT:
 1- PROVIDE COMPLIANCE WITH THE EGRESS REQUIREMENTS OF
 BEDROOM #1 SHOWN ON THE FIRST FLOOR PLAN. SPECIFY
 WINDOW TYPE, SIZE AND SILL HEIGHT SEC. R310
 FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 RESPONSE:
 THE EMERGENCY ESCAPE SHALL OPEN DIRECTLY INTO A PUBLIC
 WAY OR TO A YARD OR COURT THAT OPENS TO A PUBLIC WAY.
 SEE SEC. R310.1 FBC-RESIDENTIAL. THE DOORS SHOWN ON
 FLOOR PLAN DON'T COMPLY. THEY DON'T OPEN INTO A PUBLIC
 WAY OR YARD OR COURT THAT OPENS TO A PUBLIC WAY. REVISE
 PLANS AS REQUIRED.
  
 ORIGINAL COMMENT:
 2- SCOPE OF WORK IS NOT CLEAR. CLEARLY SPECIFY EXTENT
 OF WORK TO BE PERFORMED. WHY SUBMITTING PRODUCT
 APPROVAL FOR SINGLE HUNG WINDOWS. WHAT'S NEW , WHAT'S
 EXISTING, ETC. SEC. 107.2.1 CITY CITY AMENDMENTS.
  
 RESPONSE:
 (1) SCOPE BUILDING NOTE #1 INDICATES "REPAIR DAMAGED
 EXISTING FRAMING AND STUCCO ON EXISTING EXTERIOR WALL".
 NEED TO INDICATE ON PLANS DAMAGED AREAS AND PROVIDE
 COMPLETE DETAILS AND SPECIFICATIONS FOR THE PROPOSED
 REPAIR. SPECIFY ALL FRAMING MEMBERS AND CONNECTORS.
 SEC. R301.1 FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 (2) SCOPE BUILDING NOTE #3 INDICATES "INSTALL NEW
 INTERIOR FRAMING TO CREATE NEW UPSTAIRS BATHROOM
 ATTACHED TO MASTER BEDROOM". PROVIDE COMPLETE FRAMING
 PLANS AND SPECIFICATIONS. SPECIFY ALL FRAMING MEMBERS
 AND CONNECTORS. SEC. R301.1 FBC-RESIDENTIAL, 5TH
 EDITION (2014).
  
 ORIGINAL COMMENTS:
 3- SPECIFY CARBON MONOXIDE ALARMS FOR ALL BEDROOMS
 SHOWING COMPLIANCE WITH SEC. R315 FBC-RESIDENTIAL.
  
 RESPONSE:
 CARBON MONOXIDE ALARMS TO BE INCLUDED IN THE ORIGINAL
 DRAWING. CORRECTIONS BY HAND ON SUBMITTED COPIES ARE
 NOT ALLOWED.
  
 ORIGINAL COMMENT:
 4- PROVIDE THE NAME AND SIGNATURE IN ALL PLANS OF THE
 PERSON RESPONSIBLE FOR THE DESIGN AS REQUIRED BY SEC.
 107.2.1 CITY AMENDMENTS
  
 RESPONSE:
 STILL MISSING THE NAME OF THE PERSON RESPONSIBLE FOR
 THE DESIGN.
  
 **** PLEASE REMOVE ANY REVISED DRAWING AND INSERT THE
 NEW DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMITT OLD
 DRAWINGS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-07-05 Cont ID  
Sent By jgomez Date 2016-07-05 Time 09:11 Rev Time 0.00
Received By jgomez Date 2016-07-01 Time 18:21 Sent To  
Notes
2016-07-05 10:28:54RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW
 COMMENTS.
 CODE: FBC 5TH EDITION (2014)
  
 1- ACCORDING TO PALM BEACH COUNTY PROPERTY APPRAISER,
 THE REAR PART OF THE HOUSE IS A FINISHED OPEN PORCH.
 THERE ARE NO CITY RECORDS FOR THE CONSTRUCTION OF OF
 BEDROOM #1 AS SHOWN ON PLANS SUBMITTED. AFTER THE PLANS
 ARE REVISED, BRING PLANS TO PALM BEACH COUNTY (2300 N.
 JOG RD.) FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY
 STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE.
 COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED LAND
 DEVELOPMENT CODE.
  
 2- PROVIDE COMPLIANCE WITH THE EGRESS REQUIREMENTS OF
 BEDROOM #1 SHOWN ON THE FIRST FLOOR PLAN. SPECIFY
 WINDOW TYPE, SIZE AND SILL HEIGHT SEC. R310
 FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 3- SCOPE OF WORK IS NOT CLEAR. CLEARLY SPECIFY EXTENT
 OF WORK TO BE PERFORMED. WHY SUBMITTING PRODUCT
 APPROVAL FOR SINGLE HUNG WINDOWS. WHAT'S NEW , WHAT'S
 EXISTING, ETC. SEC. 107.2.1 CITY CITY AMENDMENTS.
  
 4- SECOND FLOOR PLAN IS NOT DRAWN CORRECTLY. IT IS VERY
 CONFUSING. IT SHOWS THE FLOOR LAYOUT OF THE FIRST FLOOR
 INSTEAD OF SHOWING THE ROOF TOPS. REVISE AS REQUIRED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 5- SPECIFY CARBON MONOXIDE ALARMS FOR ALL BEDROOMS
 SHOWING COMPLIANCE WITH SEC. R315 FBC-RESIDENTIAL.
  
 6- PROVIDE THE NAME AND SIGNATURE IN ALL PLANS OF THE
 PERSON RESPONSIBLE FOR THE DESIGN AS REQUIRED BY SEC.
 107.2.1 CITY AMENDMENTS
  
 **** PLEASE REMOVE ANY REVISED DRAWING AND INSERT THE
 NEW DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMITT OLD
 DRAWINGS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2016-10-12 Cont ID  
Sent By mvaldes Date 2016-10-12 Time 11:15 Rev Time 0.00
Received By mvaldes Date 2016-10-12 Time 10:46 Sent To  
Notes
2016-10-12 11:15:38REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
  
 PASSED WITH THE FOLLOWING PROVISO'S ( RED-LINED )
  
 1] AFCI PROTECTION REQUIRED PER NEC 210.12(B)
  
 2] TAMPER RESISITANT RECEPTACLES REQUIRED PER NEC
 406.12
  
 3] SMOKE ALARMS REQUIRED PER FBC-R 314 & 315
  
 4] LABEL METER ENCLOSURE "METER MAIN" TO COMPLY WITH
 NEC 230.70[A][1] DISCONNECTING MEANS OF SERVICE
 CONDUCTORS SHALL BE LOCATED AT A READILY ACCESSIBLE
 LOCATION NEAREST THE POINT OF ENTRANCE.
  
 5] CORRECT GROUNDING DETAILS TO A # 4 CU ELECTRODE
 CONDUCTOR PER TABLE NEC 250.66 AND ADD AN INTERSYSTEM
 BONDING TERMINAL IN ACCORDANCE WITH NEC 250.94
  
 4) CLARIFY PANEL LOCATION ? IS IT IN A CLOTHES CLOSET ?
 DOES THE WORKING SPACE HEIGHT SUFFICE THE 6.5' FROM
 FLOOR REQUIREMENT ? NEC 240.24(2)(D) & FBC-R SECTION
 E3405 WORKING CLEARANCE
  
 5) PLEASE TRY TO DARKEN IN THE ELECTRICAL POINTS ON THE
 FLOOR PLAN FOR THE QUALITY OF THE EXAMINER REVIEW.
 FBC-107 MINIMUM PLAN REVIEW
  
 - PERMIT # 16051207, 523 28TH STREET WPB FLORIDA. [
 FRONT BUILDING ]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2016-08-17 Cont ID  
Sent By mvaldes Date 2016-08-17 Time 13:28 Rev Time 0.00
Received By mvaldes Date 2016-08-17 Time 11:16 Sent To  
Notes
2016-08-17 13:51:43REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
 1) ORIGINAL PLANS WERE PASSED WITH SEVERAL PROVISO'S
 THAT WEREN'T ADDRESSED IN THE 2ND SUBMITTAL PLEASE ADD
 THE FOLLOWING NOTES:
 1A) AFCI PROTECTION REQUIRED PER NEC 210.12[B]
 1B) TAMPER RESISITANT RECEPTACLES REQUIRED PER NEC
 406.12
 1C) SMOKE ALARMS REQUIRED PER FBC-R 314 & 315
  
 2) LABEL METER ENCLOSURE "METER MAIN" TO COMPLY WITH
 NEC 230.70[A][1] DISCONNECTING MEANS OF SERVICE
 CONDUCTORS SHALL BE LOCATED AT A READILY ACCESSIBLE
 LOCATION NEAREST THE POINT OF ENTRANCE.
  
 3) CORRECT GROUNDING DETAILS TO A # 4 CU ELECTRODE
 CONDUCTOR PLUS AUGMENTATE A ROD OR COMPLY WITH PROVING
 25 OHMS TO GROUND. NEC 250.56. ADD AN INTERSYSTEM
 BONDING TERMINAL IN ACCORDANCE WITH NEC 250.94
  
 4) CLARIFY PANEL LOCATION ? IS IT IN A CLOTHES CLOSET ?
 DOES THE WORKING SPACE HEIGHT SUFFICE THE 6.5' FROM
 FLOOR REQUIREMENT ? NEC 110.26 WORKING CLEARANCE &
 FBC-R SECTION E3405
  
 5) PLEASE TRY TO DARKEN IN THE ELECTRICAL POINTS ON THE
 FLOOR PLAN FOR THE QUALITY OF THE EXAMINER REVIEW.
 FBC-107 MINIMUM PLAN REVIEW
  
 - PERMIT # 16051207, 523 28TH STREET WPB FLORIDA. [
 FRONT BUILDING ]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-06-16 Cont ID  
Sent By mvaldes Date 2016-06-16 Time 17:18 Rev Time 0.00
Received By mvaldes Date 2016-06-16 Time 16:54 Sent To  
Notes
2016-06-16 17:18:43REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
 - PASSED WITH PROVISO COMMENTS MARKED ON PLANS.

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2016-09-13 Cont ID  
Sent By gjohnson Date 2016-09-13 Time 06:44 Rev Time 0.00
Received By gjohnson Date 2016-09-13 Time 06:44 Sent To  
Notes
2016-09-13 06:46:11GAS PLAN REVIEW
 A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE
 REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK.
 PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT
 SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE
 SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC.
 107.2.1.
  
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE
 FBC-R, SEC. G2404.3.
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL
 GAS SEC. 301.3.
  
 A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION.
  
  
  
  
 GAS PERMIT APPLICATION REQUIREMENTS
  
 EFFECTIVE IMMEDIATELY THE FOLLOWING INFORMATION SHALL
 BE SHOWN ON ALL GAS DRAWINGS SUBMITTED FOR PERMITTING
 IN THE CITY OF WEST PALM BEACH:
  
 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL
 CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS PER
 FBC-2014 FUEL GAS, SECS. 402.4.1, 402.4.2.
  
 2. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL
 PIPE SIZES, AND THE EHD NUMBER OF CORRUGATED STAINLESS
 STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. WPB
 AMENDMENTS TO FBC SEC. 107.2.1.
  
 3. TYPE OF GAS, (LP OR NATURAL).
  
 4. BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD ON
 THE SYSTEM. REFER TO THE FBC-2014 FUEL GAS SECS. 401.8
 THRU 402.6.1 AND TABLES 402.4(1) THRU 402.4(37).
  
 5. SHOW THE DISTANCE FROM THE POINT OF DELIVERY,
 (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING
 AND/OR SYSTEM PER THE FBC-2014 FUEL GAS APPENDIX A ?
 USE OF CAPACITY SECTION A.3.1(4) & 2014 FUEL GAS CODE
 SEC. 402.4.1.
  
 6. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE
 FBC-2014 FUEL GAS CODE SEC. 304.
  
 7. INDICATE THE DELIVERY PRESSURE (PSI) PER FBC-2014
 FUEL GAS SEC. 402.2. IF NATURAL GAS SPECIFY .5 PSI OR 2
 PSI.
  
 8. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND
 TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE
 SEC. 502 THRU 505.
  
 9. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL
 GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA
 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2
  
 10. CLEARLY SHOW THE LOCATION AND CAPACITY OF LP
 TANK(S), TYPE OF TANK (DOT OR ASME), THE DISTANCE OF
 THE TANK FROM THE BUILDING AND ADJACENT PROPERTY LINES
 THE DISTANCE OF THE TANK FROM ALL SOURCES OF IGNITION,
 OTHER CONTAINERS, BUILDINGS, AND THE LOCATION OF ANY
 BUILDING OPENINGS BELOW THE RELIEF VALVE OF THE TANK
 PER NFPA 58, TABLE 3-2.2.2.
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2016-08-22 Cont ID  
Sent By destabro Date 2016-08-22 Time 13:05 Rev Time 0.00
Received By destabro Date 2016-08-22 Time 13:05 Sent To B
Notes
2016-08-22 13:19:068/22/16 - CONTRIBUTING PROPERTY TO THE OLD NORTHWOOD
 HISTORIC DISTRICT. REVISED PLANS FOR MAIN HOUSE INCLUDE
 THE REPAIR OF EXTERIOR STUCCO. APPLICANT MUST MAINTAIN
 EXISTING TEXTURED STUCCO APPEARANCE. WINDOW AND DOOR
 REPLACEMENT IS PROPOSED ONLY FOR ACCESSORY REAR
 STRUCTURE. DLE

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2016-06-01 Cont ID  
Sent By fmittner Date 2016-06-01 Time 11:11 Rev Time 0.00
Received By fmittner Date 2016-06-01 Time 11:07 Sent To  
Notes
2016-06-01 14:46:14SAW ACCESSORY STRUCTURE IS UNDER SEPERATE PERMIT
 16051208. SICNE THIS PERMIT FOR MAIN STRUCTURE
 INDICATES ONLY INTERIOR, HISOTRIC IS N/A
2016-06-01 11:13:21PERMIT PACKET INDICATES WINDOW REPLACEMENT IN ACCESSORY
 STRUCTURE. NEED TO KNOW WHAT EXISTING WINDOWS ARE AND
 WHAT LITE PATTERN IS GOING IN, LIST FRAME COLOR AND
 CLEAR GLASS OR LOW-E NO TINT. QUESTIONS, CONTACT
 FRIEDERIKE MITTNER, CITY HSITORIC PRESERVATION PLANNER
 AT (561) 822-1457.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-09-22 Cont ID  
Sent By cpuell Date 2016-09-22 Time 09:43 Rev Time 0.00
Received By cpuell Date 2016-08-12 Time 15:53 Sent To  
Notes
2016-08-15 15:53:50R30
 **TRAVELLING WITH 16051208**

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-07-05 Cont ID  
Sent By jgomez Date 2016-07-05 Time 10:46 Rev Time 0.00
Received By jgomez Date 2016-05-26 Time 13:15 Sent To  
Notes
2016-05-27 13:16:09R03

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2016-08-29 Cont ID  
Sent By jgomez Date 2016-08-29 Time 14:40 Rev Time 0.00
Received By jgomez Date 2016-08-29 Time 14:40 Sent To  
Notes
2016-08-29 14:50:00$236.59 PAID. MU-2016 019990.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2016-07-05 Cont ID  
Sent By jgomez Date 2016-07-05 Time 10:32 Rev Time 0.00
Received By jgomez Date 2016-07-05 Time 10:32 Sent To  
Notes
2016-07-05 10:32:451- ACCORDING TO PALM BEACH COUNTY PROPERTY APPRAISER,
 THE REAR PART OF THE HOUSE IS A FINISHED OPEN PORCH.
 THERE ARE NO CITY RECORDS FOR THE CONSTRUCTION OF OF
 BEDROOM #1 AS SHOWN ON PLANS SUBMITTED. AFTER THE PLANS
 ARE REVISED, BRING PLANS TO PALM BEACH COUNTY (2300 N.
 JOG RD.) FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY
 STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE.
 COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED LAND
 DEVELOPMENT CODE.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By jvalido Date 2016-09-21 Time 17:09 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-06-15 Cont ID  
Sent By jvalido Date 2016-06-15 Time 11:58 Rev Time 0.00
Received By jvalido Date 2016-06-15 Time 11:29 Sent To  
Notes
2016-06-15 11:58:43CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA
 BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION
  
 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS
 PROVIDE MECHANICAL PLANS. DIFFERENTIATE ALL NEW
 DUCTWORK FROM EXISTING DUCTWORK ON PLANS.

Review Stop P PLUMBING
Rev No 3 Status P Date 2016-10-12 Cont ID  
Sent By gjohnson Date 2016-10-12 Time 13:30 Rev Time 0.00
Received By gjohnson Date 2016-10-12 Time 13:30 Sent To  
Notes
2016-10-12 13:30:57APPROVED WITH PROVISO
  
 PROVIDE BEFORE FIRST INSPECTION
  
 A APPROVED BY BUILDING DEPARTMENT RISER DIAGRAM
 CONTAINING THE FOLLOWING:
  
 1.PLEASE PROVIDE A COMPLETE RISER DIAGRAM. SHOWING
 EXISTING AND NEW PIPING AND REFLECTING THE FLOOR PLAN.
 PER WPB AMEND TO FBC 107.3.5.3(11)
  
 2. SHOW EXISTING AND NEW PIPING AND NEW TANKLESS HEATER
 ON WATER RISER DIAGRAM. PER WPB AMEND TO FBC
 107.3.5.3(11)
  
 3. THE FOLLOWING FIXTURES NEED VENTS, MASTER BATH LAV ,
 KITCHEN SINK ,WASHING MACHINE . PER FBC RES P3101.2.1
  
 4. SHOW THE P-TRAPS ON THE SINKS, SHOWERS, TUBS AND
 WASHING MACHINE. PER WPB AMEND TO FBC 107.2.1
  
 5. A CLEAN OUT IS REQUIRED AT THE BASE OF THE SOIL
 STACK FROM THE SECOND FLOOR. PER FBC RES P3005.2.6
  
  
  
  
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2016-09-13 Cont ID  
Sent By gjohnson Date 2016-09-13 Time 06:06 Rev Time 0.00
Received By gjohnson Date 2016-09-12 Time 16:21 Sent To  
Notes
2016-09-13 06:06:432ND REVIEW
  
  
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
  
 PLUMBING COMMENTS: DUE TO NEW DRAWING BEING SUBMITTED
 THE FOLLOWING DEFICIENCIES IN THE PLANS WERE FOUND
  
 1.PLEASE PROVIDE A COMPLETE RISER DIAGRAM. SHOWING
 EXISTING AND NEW PIPING AND REFLECTING THE FLOOR PLAN.
 PER WPB AMEND TO FBC 107.3.5.3(11)
  
 2. SHOW EXISTING AND NEW PIPING AND NEW TANKLESS HEATER
 ON WATER RISER DIAGRAM. PER WPB AMEND TO FBC
 107.3.5.3(11)
  
 3. THE FOLLOWING FIXTURES NEED VENTS, MASTER BATH LAV ,
 KITCHEN SINK ,WASHING MACHINE . PER FBC RES P3101.2.1
  
 4. SHOW THE P-TRAPS ON THE SINKS, SHOWERS, TUBS AND
 WASHING MACHINE. PER WPB AMEND TO FBC 107.2.1
  
 5. A CLEAN OUT IS REQUIRED AT THE BASE OF THE SOIL
 STACK FROM THE SECOND FLOOR. PER FBC RES P3005.2.6
  
  
  
  
  
2016-08-29 14:04:37NEW DRAWINGS SUBMITTED.

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-06-09 Cont ID  
Sent By gjohnson Date 2016-06-09 Time 14:29 Rev Time 0.00
Received By gjohnson Date 2016-06-09 Time 14:28 Sent To  
Notes
2016-06-09 14:34:59REVIEW APPROVED BY GEORGE EARL