Plan Review Details - Permit 16051150
Plan Review Stops For Permit 16051150 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2016-05-31 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-05-31 |
Time |
15:04 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-05-31 |
Time |
14:55 |
Sent To |
HIST |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-05-27 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-05-27 |
Time |
18:41 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-05-27 |
Time |
18:20 |
Sent To |
|
|
Notes |
2016-05-27 18:43:02 | BUILDING REVIEW COMMENTS TO REVISION SUBMITTED TO | | ADDRESS PROVISO DATED 05/10/16: | | | | ORIGINAL COMMENT: | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR: | | A) NEW OVERHEAD GARAGE DOORS AS SHOWN ON PLANS. | | RESPONSE: NOT ADDRESSED. NO PRODUCT APPROVAL SUBMITTED | | AT THIS TIME. | | | | B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS | | AND DETAILS. | | RESPONSE: OK. | | | | 2- ARCHITECT TO REVIEW/APPROVE PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.34.1 CITY AMENDMENTS. | | RESPONSE: THIS APPLIES TO GARAGE DOORS. NO PRODUCT | | APPROVAL SUBMITTED YET. | | | | ORIGINAL COMMENT: | | 3- PROVIDE COMPLETE FRAMING DETAIL FOR THE INSTALLATION | | OF TWO OVERHEAD GARAGE DOORS INSTEAD OF ONE AS SHOWN ON | | PLANS. SPECIFY ALL FRAMING MEMBERS AND CONNECTORS. SEC. | | R301.1 FBC-RESIDENTIAL, 5TH EDITION (2014). | | RESPONSE: REVISED DRAWING DOESN'T SPECIFY THE | | STRUCTURAL CONNECTORS OF ALL THE FRAMING MEMBERS OF THE | | NEW GARAGE DOORS. PROVIDE COMPLETE FRAMING DETAILS AND | | SPECIFICATIONS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2016-06-01 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-05-27 |
Time |
18:43 |
Rev Time |
0.00 |
Received By |
destabro |
Date |
2016-06-01 |
Time |
15:31 |
Sent To |
|
|
Notes |
2016-06-01 15:32:03 | 6/1/16 - PASSED PER PRODUCT APPROVAL SUBMITTAL. DLE | 2016-05-27 19:03:18 | REVISION DENIED BY BUILDING. NO NEED TO SEND TO | | HISTORIC NOW. PLANS WILL BE SENT TO HISTORIC AFTER | | PLANS ARE REVISED AND GARAGE DOORS PRODUCT APPROVALS | | ARE SUBMITTED. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-05-31 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-05-31 |
Time |
15:03 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-05-31 |
Time |
14:53 |
Sent To |
|
|
Notes |
2016-05-31 14:54:56 | JOSE VALDES SUBMITTED GARAGE DOORS PRODUCT APPROVALS | | AND ARCHITECT'S LETTER WITH FRAMING SPECIFICATIONS. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-05-27 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-05-27 |
Time |
19:01 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-05-26 |
Time |
14:16 |
Sent To |
|
|
Notes |
2016-05-26 14:16:57 | REVISION ROUTED TO JGOMEZ |
|
|
|