Plan Review Details - Permit 16050912
Plan Review Stops For Permit 16050912 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2017-03-04 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-03-04 |
Time |
08:30 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-03-04 |
Time |
07:30 |
Sent To |
|
|
Notes |
2017-03-04 08:23:45 | BUILDING PLAN REVIEW | | NORTON MUSEUM | | W. P. B. PERMIT: 16050912 BUILDING PERMIT | | ADD: 1451 S. OLIVE AVE. | | CONT: GILBANE | | TEL: 561-236-7052 | | E-MAIL: [email protected] MICHAEL IZZO | | E-MAIL: [email protected] MICHAEL J BEAUMIER | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 4TH REVIEW | | DATE: SAT. 04/ 2017 | | ACTION: APPROVED / BUILDING PROVISO | | | | NOTICE: ROBERT BROWN HAS WRITTEN A LETTER OF APPROVAL | | FOR ALTERNATE MATERIALS AND DESIGN. E-MAIL MAY 04/2015 | | AND DESIGN MEETING FROM TUES. JUNE 09/2015 WOULD | | REQUIRE ALTERNATE MATERIALS AND DESIGN METHODS, | | (PROPOSED COMPLIANCE METHOD), ERIC H. COTE SENIOR | | TECHNICAL ADVISOR. | | | | **THE TYPE IB CONSTRUCTION CLASSIFICATION IS BASED ON | | THE TOTAL COMBINED HEIGHT AND AREA OF ALL | | EXISTING-TO-REMAIN BUILDING PORTIONS+ PROPOSED | | ADDITIONS, INCLUDING PLANNED FUTURE ADDITIONS. | | ** THE MATERIALS OF CONSTRUCTION AND ASSOCIATED FIRE | | RESISTANCE RATINGS OF THE EXISTING TO REMAIN BUILDING | | PORTIONS WILL REMAIN UNCHANGED (I.E., PREDOMINATELY | | TYPE IIA, PROTECTED NONCOMBUSTIBLE CONSTRUCTION, OR | | BETTER, EXCEPT FOR EXISTING ROOF CONSTRUCTION IN THE | | CIRCA 1940-1942 PORTIONS). | | ** THE NEW AND EXISTING-TO-REMAIN BUILDING PORTIONS | | WILL FUNCTION AS A SINGLE BUILDING IN ALL RESPECTS. | | | | | | 1) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. WITHIN THE STILLER | | AUDITORIUM THERE IS A PLATFORM LIFT TO GAIN ACCESS TO | | THE LOWER VIEWING AREA. COMPLIANCE FOR THE FLORIDA 2014 | | ACCESSIBILITY CODE FOR VERTICAL ACCESSIBILITY IS BEING | | ACHIEVED BY THE PLATFORM LIFT, ACCESS CODE 207.1 AND AS | | PART OF A MEANS OF EGRESS IT ALSO HAS TO COMPLY WITH | | 1003.2.13 OF THE INTERNATIONAL BUILDING CODE 2000 | | EDITION AND THE 2001 SUPPLEMENT OR SECTION 1007 OF THE | | IBC-B 2003 EDITION. IN THE 2003 IBC-B 1007.5. PLATFORM | | LIFTS (WHEEL CHAIR) SHALL NOT SERVE AS PART OF AN | | ACCESSIBLE MEANS OF EGRESS, EXCEPT WHERE ALLOWED AS | | PART OF A REQUIRED ACCESSIBLE ROUTE IN SECTION 1109.7. | | PLATFORM | | LIFTS IN ACCORDANCE WITH SECTION 2702 SHALL BE | | INSTALLED IN ACCORDANCE WITH ASME A18.1. STANDBY POWER | | SHALL BE PROVIDED FOR THE PLATFORM LIFTS PERMITTED TO | | SERVE AS A PART OF A MEANS OF EGRESS. | | | | 2) PROVISO: 2014FBC-ACCESSIBLITY CODE 703.4.1 HEIGHT | | ABOVE FINISH FLOOR OR GROUND. TACTILE CHARACTERS ON | | SIGNS SHALL BE LOCATED 48 INCHES (1220 MM) MINIMUM | | ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM | | THE BASELINE OF THE LOWEST TACTILE CHARACTER AND 60 | | INCHES (1525 MM) MAXIMUM ABOVE THE FINISH FLOOR OR | | GROUND SURFACE, MEASURED FROM THE BASELINE OF THE | | HIGHEST TACTILE CHARACTER. | | | | 3) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... 2014 | | FBC-ACCESSIBILITY CODE THE USE OF PLATFORM LIFTS IS | | VERY LIMITED IN THEIR USE IN NEW CONSTRUCTION. PLEASE | | REVIEW THE 2014 FBC-ACCESS. CODE 206.7(1-10). | | | | 4) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... SHEET | | 0157_A420 DETAIL # 2 INDICATES THE USE OF FULLY ADHERED | | PVC ROOFING TO 5/8 INCH THERMAL BARRIER THEN METAL | | DECKING. PLEASE IDENTIFY THE 5/8 INCH THERMAL BARRIER | | COMPONENT, SHOW COMPLIANCE WITH FBC-B 603. | | | | 5) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... | | SHOP DRAWINGS ARE TO BE SUBMITTED FOR THE TYPE OF WALL | | AND CEILING SHEATHING/ PANELING AND OR FOAM AND OR | | FABRIC FINISHES. THERE MAY BE USE OF A FOAM PANEL THE | | PLANS ARE NOT CLEAR, BUT THERE IS FABRIC PANELS AS | | SPECIFIED. PLEASE PROVIDE COMPLIANCE WITH FBC-B | | 803.11.2 SET-OUT CONSTRUCTION. WHERE WALLS AND CEILINGS | | ARE REQUIRED TO BE OF FIRE-RESISTANCE-RATED OR | | NONCOMBUSTIBLE CONSTRUCTION AND WALLS ARE SET OUT OR | | CEILINGS ARE DROPPED DISTANCES GREATER THAN SPECIFIED | | IN SECTION 803.11.1, CLASS A FINISH MATERIALS, IN | | ACCORDANCE WITH SECTION 803.1.1 OR 803.1.2 SHALL BE | | USED. | | | | 6) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... | | SHEETS 0269_FS200 & 0270_FS201 BOTH SHOW KITCHEN | | EXHAUST HOODS REQUIRE A SEPARATE PERMIT. THE SHAFTS | | WOULD BE COVERED UNDER THE BUILDING PERMIT. | | | | 7) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... | | SHEETS 0285_S120.7 & 0286_S120.8 THE WATER FEATURE ALSO | | WILL REQUIRE A SEPARATE PERMIT, SHOW THE SAME DETAIL | | SHEETS UNDER THE ARCHITECTURAL, STRUCTURAL, ELECTRICAL | | & PLUMBING DISCIPLES. | | | | 8) COMPLIED. PRESSURES : SHEETS S008, S009, & S010. | | | | 9) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... | | | | 10) MISSING PRODUCT APPROVALS. 2010/ 2014 FBC-B | | 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.4.1 | | COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY | | AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF | | PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE | | PRODUCT APPROVALS: | | (31)(A) EXTERIOR DOORS. | | (B) WINDOWS | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | LOUVERS, EFIS SYSTEMS, | | (D) ROOFING PRODUCTS AND ASSEMBLIES | | (E) SHUTTERS | | (F) SKYLIGHTS | | | | 11) PROVISO: ADMINISTRATION 107.3.4 DESIGN PROFESSIONAL | | IN RESPONSIBLE CHARGE. THE REGISTERED DESIGN | | PROFESSIONAL IN RESPONSIBLE CHARGE SHALL BE RESPONSIBLE | | FOR REVIEWING AND COORDINATING SUBMITTAL DOCUMENTS | | PREPARED BY OTHERS, INCLUDING PHASED AND DEFERRED | | SUBMITTAL ITEMS, FOR COMPATIBILITY WITH THE DESIGN OF | | THE BUILDING. THOSE PRODUCTS WHICH ARE REGULATED BY DCA | | RULE 9N-3SHALL BE REVIEWED AND APPROVED IN WRITING BY | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL. | | | | 12) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... | | ROOFING: FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY ALL | | ROOFING SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES FOR | | ROOF ZONE # 1. REVIEW THE PRODUCT APPROVAL LIMITATIONS, | | IF ENHANCED FASTENING IS ALLOWED FOR ROOF ZONES 2 & 3. | | IF SO RAS 117 CALCULATIONS ARE REQUIRED BY EITHER A | | FLORIDA ARCHITECT OR ENGINEER. | | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED TO | | DETERMINE CODE COMPLIANCE. 2014 FBC-B 1603.1.4 WIND | | DESIGN DATA. | | | | 13) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... | | 2014 FBC-M- 301.15 WIND RESISTANCE. MECHANICAL | | EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO | | WIND SHALL BE DESIGNED AND INSTALLED TO RESIST THE WIND | | PRESSURES DETERMINED IN ACCORDANCE WITH THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 14) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... | | FBC-B 1013.7 ROOF ACCESS. GUARDS SHALL BE PROVIDED | | WHERE THE ROOF HATCH OPENING IS LOCATED WITHIN 10 FEET | | (3048 MM) OF A ROOF EDGE OR OPEN SIDE OF A WALKING | | SURFACE AND SUCH EDGE OR OPEN SIDE IS LOCATED MORE THAN | | 30 INCHES (762 MM) ABOVE THE FLOOR, ROOF OR GRADE | | BELOW. THE GUARD SHALL BE CONSTRUCTED SO AS TO PREVENT | | THE PASSAGE OF A SPHERE 21 INCHES (533 MM) IN DIAMETER. | | | | 15) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... | | FBC-B 1509.6.1 HEIGHT LIMITATIONS. MECHANICAL EQUIPMENT | | SCREENS SHALL NOT EXCEED 18 FEET (5486 MM) IN HEIGHT | | ABOVE THE ROOF DECK, AS MEASURED TO THE HIGHEST POINT | | ON THE MECHANICAL EQUIPMENT SCREEN. | | | | 16) PROVISO: TYPE IB & IIA BUILDING REQUIRE FIRE | | RESISTANCE RATING FOR BUILDING ELEMENTS PER TABLE 601 | | OF THE 2014 FBC-B. PLEASE PROVIDE COMPLIANCE WITH THIS | | SECTION OF THE CODE. FIRE PROTECTION SHOP DRAWING ARE | | TO BE PREPARED TO MEET TABLE 6501 OF THE 2014 FBC-B BY | | G. C. AND SUBMITTED TO THE DESIGNER OF RECORD FOR | | REVIEW AND APPROVAL BEFORE BEING SUBMITTED TO THE | | BUILDING DEPARTMENT. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2017-01-23 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-01-23 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-01-09 |
Time |
08:49 |
Sent To |
|
|
Notes |
2017-01-23 13:57:50 | BUILDING PLAN REVIEW | | NORTON MUSEUM | | W. P. B. PERMIT: 16050912 BUILDING PERMIT | | ADD: 1451 S. OLIVE AVE. | | CONT: GILBANE | | TEL: 561-236-7052 | | E-MAIL: [email protected] MICHAEL IZZO | | E-MAIL: [email protected] MICHAEL J BEAUMIER | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 3RD REVIEW | | DATE: MON. JAN. 23/ 2017 | | ACTION: DENIED | | | | NOTICE: ROBERT BROWN HAS WRITTEN A LETTER OF APPROVAL | | FOR ALTERNATE MATERIALS AND DESIGN. E-MAIL MAY 04/2015 | | AND DESIGN MEETING FROM TUES. JUNE 09/2015 WOULD | | REQUIRE ALTERNATE MATERIALS AND DESIGN METHODS, | | (PROPOSED COMPLIANCE METHOD), ERIC H. COTE SENIOR | | TECHNICAL ADVISOR. | | | | 1) COMPLIED. | | | | 2) COMPLIED UNDER THE STRUCTURAL ONLY PERMIT 16080215, | | GEOTECHNICAL REPORT COMPLETED BY ARDAMAN 12/16/2014. | | | | 4A-H) COMPLIED. | | | | 4I) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. WITHIN THE STILLER | | AUDITORIUM THERE IS A PLATFORM LIFT TO GAIN ACCESS TO | | THE LOWER VIEWING AREA. COMPLIANCE FOR THE FLORIDA 2014 | | ACCESSIBILITY CODE FOR VERTICAL ACCESSIBILITY IS BEING | | ACHIEVED BY THE PLATFORM LIFT, ACCESS CODE 207.1 AND AS | | PART OF A MEANS OF EGRESS IT ALSO HAS TO COMPLY WITH | | 1003.2.13 OF THE INTERNATIONAL BUILDING CODE 2000 | | EDITION AND THE 2001 SUPPLEMENT OR SECTION 1007 OF THE | | IBC-B 2003 EDITION. IN THE 2003 IBC-B 1007.5. PLATFORM | | LIFTS (WHEEL CHAIR) SHALL NOT SERVE AS PART OF AN | | ACCESSIBLE MEANS OF EGRESS, EXCEPT WHERE ALLOWED AS | | PART OF A REQUIRED ACCESSIBLE ROUTE IN SECTION 1109.7. | | PLATFORM | | LIFTS IN ACCORDANCE WITH SECTION 2702 SHALL BE | | INSTALLED IN ACCORDANCE WITH ASME A18.1. STANDBY POWER | | SHALL BE PROVIDED FOR THE PLATFORM LIFTS PERMITTED TO | | SERVE AS A PART OF A MEANS OF EGRESS. | | | | 4J) PROVISO: 2014FBC-ACCESSIBLITY CODE 703.4.1 HEIGHT | | ABOVE FINISH FLOOR OR GROUND. | | TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48 INCHES | | (1220 MM) MINIMUM ABOVE THE FINISH FLOOR OR GROUND | | SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST | | TACTILE CHARACTER AND 60 INCHES (1525 MM) MAXIMUM ABOVE | | THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE | | BASELINE OF THE HIGHEST TACTILE CHARACTER. | | | | | | | | | | | | 5A) COMPLIED. | | | | 5B) 3RD REQUEST. TO CONSIDER THE EXIT PASSAGE WAY | | INDICATED AS CORRIDOR 101M TO BE AN EXTENSION OF THE | | VERTICAL EXIT, THERE WILL NEED TO HAVE A CUT SECTION | | THROUGH THE EXIT ACCESS CORRIDOR (EXIT PASSAGEWAY) EAST | | WEST THAT SHOWS THE FLOOR/ CEILING ASSEMBLIES BELOW AND | | ABOVE WITH THE RATING OF NOT ONLY THE HORIZONTAL | | ASSEMBLIES BUT OF THE VERTICAL SUPPORTING FRAMING. EXIT | | PASSAGEWAYS SHALL BE CONSTRUCTED IN ACCORDANCE WITH | | SECTION 707 OR HORIZONTAL ASSEMBLIES CONSTRUCTED IN | | ACCORDANCE WITH SECTION 711 OR BOTH. SINCE THERE IS | | ROOMS EITHER BELOW OR ABOVE THE EXIT PASSAGEWAY WILL | | NEED TO HAVE THE SAME RATING AS THE VERTICAL EXIT. THIS | | IS NOT CONSIDERED AN EXTENSION TO A STAIRWAY (EXIT | | PASSAGEWAY) IN SECTION 1022.3.1 A FIRE DOOR ASSEMBLY | | COMPLYING WITH SECTION 716.5 SHALL BE INSTALLED IN THE | | FIRE BARRIER TO PROVIDE A MEANS OF EGRESS FROM THE | | INTERIOR EXIT STAIRWAY TO THE EXIT PASSAGEWAY. THE DOOR | | PROTECTS THE VERTICAL EXIT FROM SMOKE AND FIRE. THIS | | REQUEST IS NOT ONLY FROM THE PLAN REVIEWER BUT ALSO THE | | BUILDING OFFICIAL ROBERT BROWN. | | | | 2ND ROUND OF COMMENTS. RESPONSE INDICATES THE ENCLOSURE | | THAT CONNECTS THE OCCUPIED SPACE TO THE VERTICAL EXIT | | ENCLOSURE IS 2 HOUR RATED. IS THIS 2 HOUR RATING RATHER | | THAN HAVE A DOOR SEPARATING THE VERTICAL EXIT FROM THIS | | SPACE, ARE YOU LOOKING THIS IS ALTERNATE MATERIALS AND | | DESIGN METHODS? IF SO YOU WOULD NEED TO REQUEST SO IN | | WRITTEN FORM TO THE BUILDING OFFICIAL. 2014 FLORIDA | | BUILDING CODE W 2014 WEST PALM BEACH AMENDMENTS TO THE | | FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION 104.11 | | ALTERNATE MATERIALS, DESIGN AND METHODS OF | | CONSTRUCTION. | | | | 1ST ROUND OF COMMENTS. ON SHEET 0013_LS101M THERE IS A | | VERTICAL EXIT STAIR # 5 AND ADJACENT TO THE STAIR | | CORRIDOR 101M. THERE IS NO EXIT DOOR SEPARATING THE | | VERTICAL EXIT FROM EITHER AN EXIT ACCESS CORRIDOR OR AN | | EXIT PASSAGE WAY. HIS USE APPEARS TO BE AN EXIT ACCESS | | CORRIDOR MISSING THE DOOR TO THE VERTICAL EXIT. | | 2014 FBC-B 1022.4 OPENINGS. INTERIOR EXIT STAIRWAY AND | | RAMP OPENING PROTECTIVES SHALL BE IN ACCORDANCE WITH | | THE REQUIREMENTS OF SECTION 716. SEE TABLE 716.5. | | OPENINGS IN INTERIOR EXIT STAIRWAYS AND RAMPS OTHER | | THAN UNPROTECTED EXTERIOR OPENINGS SHALL BE LIMITED TO | | THOSE NECESSARY FOR EXIT ACCESS TO THE ENCLOSURE FROM | | NORMALLY OCCUPIED SPACES AND FOR EGRESS FROM THE | | ENCLOSURE. | | | | 6A) COMPLIED. 6B) EXISTING CONDITION. | | | | 6C-G) COMPLIED. | | | | 6H) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... 2014 | | FBC-ACCESSIBILITY CODE THE USE OF PLATFORM LIFTS IS | | VERY LIMITED IN THEIR USE IN NEW CONSTRUCTION. PLEASE | | REVIEW THE 2014 FBC-ACCESS. CODE 206.7(1-10). | | | | 6I-6J) COMPLIED. | | | | 7) COMPLIED. | | 8A) 2ND REQUEST. PLEASE CLARIFY IN THE F P DRAWINGS, | | WHICH SHEET COMPLIANCE CAN BE FOUND. SHEET 0171_A510 | | DETAIL DOES PROVIDE A DETAIL FOR THE DRAFT CURTAIN BUT | | AGAIN THERE IS NO MENTION OF CLOSELY SPACED SPRINKLERS | | IN ACCORDANCE WITH NFPA 13. | | | | 9) COMPLIED. | | | | 10) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... SHEET | | 0157_A420 DETAIL # 2 INDICATES THE USE OF FULLY ADHERED | | PVC ROOFING TO 5/8 INCH THERMAL BARRIER THEN METAL | | DECKING. PLEASE IDENTIFY THE 5/8 INCH THERMAL BARRIER | | COMPONENT, SHOW COMPLIANCE WITH FBC-B 603. | | | | 11&12, A-C) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO | | BE SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... | | SHOP DRAWINGS ARE TO BE SUBMITTED FOR THE TYPE OF WALL | | AND CEILING SHEATHING/ PANELING AND OR FOAM AND OR | | FABRIC FINISHES. THERE MAY BE USE OF A FOAM PANEL THE | | PLANS ARE NOT CLEAR, BUT THERE IS FABRIC PANELS AS | | SPECIFIED. PLEASE PROVIDE COMPLIANCE WITH FBC-B | | 803.11.2 SET-OUT CONSTRUCTION. WHERE WALLS AND CEILINGS | | ARE REQUIRED TO BE OF FIRE-RESISTANCE-RATED OR | | NONCOMBUSTIBLE CONSTRUCTION AND WALLS ARE SET OUT OR | | CEILINGS ARE DROPPED DISTANCES GREATER THAN SPECIFIED | | IN SECTION 803.11.1, CLASS A FINISH MATERIALS, IN | | ACCORDANCE WITH SECTION 803.1.1 OR 803.1.2, SHALL BE | | USED. | | | | 13 & 14) COMPLIED. | | | | 15) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... | | SHEETS 0269_FS200 & 0270_FS201 BOTH SHOW KITCHEN | | EXHAUST HOODS REQUIRE A SEPARATE PERMIT. THE SHAFTS | | WOULD BE COVERED UNDER THE BUILDING PERMIT. | | | | 16) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... | | SHEETS 0285_S120.7 & 0286_S120.8 THE WATER FEATURE ALSO | | WILL REQUIRE A SEPARATE PERMIT, SHOW THE SAME DETAIL | | SHEETS UNDER THE ARCHITECTURAL, STRUCTURAL, ELECTRICAL | | & PLUMBING DISCIPLES. | | | | 17) COMPLIED. PRESSURES : SHEETS S008, S009, & S010. | | | | 18) COMPLIED SEE STRUCTURAL PERMIT: 16080215. | | | | 19) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... | | 19) MISSING PRODUCT APPROVALS. 2010/ 2014 FBC-B | | 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.4.1 | | COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY | | AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF | | PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE | | PRODUCT APPROVALS: | | (31)(A) EXTERIOR DOORS. | | (B) WINDOWS | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | LOUVERS, EFIS SYSTEMS, | | (D) ROOFING PRODUCTS AND ASSEMBLIES | | (E) SHUTTERS | | (F) SKYLIGHTS | | | | 20) PROVISO: ADMINISTRATION 107.3.4 DESIGN PROFESSIONAL | | IN RESPONSIBLE CHARGE. THE REGISTERED DESIGN | | PROFESSIONAL IN RESPONSIBLE CHARGE SHALL BE RESPONSIBLE | | FOR REVIEWING AND COORDINATING SUBMITTAL DOCUMENTS | | PREPARED BY OTHERS, INCLUDING PHASED AND DEFERRED | | SUBMITTAL ITEMS, FOR COMPATIBILITY WITH THE DESIGN OF | | THE BUILDING. THOSE PRODUCTS WHICH ARE REGULATED BY DCA | | RULE 9N-3SHALL BE REVIEWED AND APPROVED IN WRITING BY | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL. | | | | 21) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... | | ROOFING: FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY ALL | | ROOFING SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES FOR | | ROOF ZONE # 1. REVIEW THE PRODUCT APPROVAL LIMITATIONS, | | IF ENHANCED FASTENING IS ALLOWED FOR ROOF ZONES 2 & 3. | | IF SO RAS 117 CALCULATIONS ARE REQUIRED BY EITHER A | | FLORIDA ARCHITECT OR ENGINEER. | | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED TO | | DETERMINE CODE COMPLIANCE. 2014 FBC-B 1603.1.4 WIND | | DESIGN DATA. | | | | 22) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... | | 2014 FBC-M- 301.15 WIND RESISTANCE. MECHANICAL | | EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO | | WIND SHALL BE DESIGNED AND INSTALLED TO RESIST THE WIND | | PRESSURES DETERMINED IN ACCORDANCE WITH THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 23) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... | | FBC-B 1013.7 ROOF ACCESS. GUARDS SHALL BE PROVIDED | | WHERE THE ROOF HATCH OPENING IS LOCATED WITHIN 10 FEET | | (3048 MM) OF A ROOF EDGE OR OPEN SIDE OF A WALKING | | SURFACE AND SUCH EDGE OR OPEN SIDE IS LOCATED MORE THAN | | 30 INCHES (762 MM) ABOVE THE FLOOR, ROOF OR GRADE | | BELOW. THE GUARD SHALL BE CONSTRUCTED SO AS TO PREVENT | | THE PASSAGE OF A SPHERE 21 INCHES (533 MM) IN DIAMETER. | | | | 24) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... | | FBC-B 1509.6.1 HEIGHT LIMITATIONS. MECHANICAL EQUIPMENT | | SCREENS SHALL NOT EXCEED 18 FEET (5486 MM) IN HEIGHT | | ABOVE THE ROOF DECK, AS MEASURED TO THE HIGHEST POINT | | ON THE MECHANICAL EQUIPMENT SCREEN. | | | | 25) 2ND REQUEST TYPE IB & IIA BUILDING REQUIRE FIRE | | RESISTANCE RATING FOR BUILDING ELEMENTS PER TABLE 601 | | OF THE 2014 FBC-B. PLEASE PROVIDE COMPLIANCE WITH THIS | | SECTION OF THE CODE. CLARIFICATION. PLEASE PROVIDE HOW | | CODE COMPLIANCE WILL BE ACHIEVED, USING WHAT METHODS | | AND MATERIALS. A SPECIFICATION IS JUST THAT, PLEAS | | PROVIDE THE DOCUMENTS HOW THE FIRE RATING OF STRUCTURAL | | MEMBERS WILL BE ACHIEVED. | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. SUCH | | DRAWINGS AND SPECIFICATIONS SHALL CONTAIN INFORMATION, | | IN THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY | | WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE | | SPECIFIC, AND THE TECHNICAL CODES SHALL NOT BE CITED AS | | A WHOLE OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | INFORMATION. | | | | NEW COMMENT. TYPE IB & IIA BUILDING REQUIRE FIRE | | RESISTANCE RATING FOR BUILDING ELEMENTS PER TABLE 601 | | OF THE 2014 FBC-B. PLEASE PROVIDE COMPLIANCE WITH THIS | | SECTION OF THE CODE. THANK YOU. | | | | 26 ) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2016-10-29 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-10-29 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-10-28 |
Time |
11:11 |
Sent To |
|
|
Notes |
2016-10-29 10:24:36 | BUILDING PLAN REVIEW | | NORTON MUSEUM | | W. P. B. PERMIT: 16050912 BUILDING PERMIT | | ADD: 1451 S. OLIVE AVE. | | CONT: GILBANE | | TEL: 561-236-7052 | | E-MAIL: [email protected] MICHAEL IZZO | | E-MAIL: [email protected] MICHAEL J BEAUMIER | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE: SAT. 29/ 2016 | | ACTION: DENIED | | | | NOTICE: ROBERT BROWN IS SUPPOSE TO WRITE A LETTER OF | | APPROVAL FOR ALTERNATE MATERIALS AND DESIGN. | | | | 1) COMPLIED. | | | | 2) 2ND REQUEST, NOT COMPLETED UNDER THE FOUNDATION/ | | STRUCTURE ONLY PERMIT. SHEET 0277_S003 HEADING | | FOUNDATIONS INDICATES THERE WAS A GEOTECHNICAL REPORT | | COMPLETED BY ARDAMAN 12/16/2014. PLEASE SUBMIT REPORT. | | NOTE WHEN SUBMITTED ELECTRONICALLY THE SOILS ENGINEER | | WILL NEED TO SUBMIT UNDER AN ELECTRONIC SEAL PER | | 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING | | ELECTRONICALLY TRANSMITTED PLANS, SPECIFICATIONS, | | REPORTS OR OTHER DOCUMENTS (ELECTRONIC SEALS). | | OTHERWISE ONE PAPER ORIGINAL SIGNED AND SEALED DOCUMENT | | WILL BE RETAINED AND SCANNED INTO THE SYSTEM. | | PLEASE NOTE THE RESPONSE UNDER THE STRUCTURE ONLY | | PERMIT WAS THAT A PAPER COPY WAS ALREADY SUBMITTED TO | | THE BUILDING DEPARTMENT. I?VE CHECKED WITH THE | | ELECTRONIC PLAN REVIEW LIBRARIAN ON THE INCOMING | | APPLICATION AND ASSORTED PAPERWORK, THERE IS NO PAPER A | | GEOTECHNICAL REPORT COMPLETED BY ARDAMAN 12/16/2014 | | WITHIN THE PAPERWORK, THE LIBRARIAN RECORDS SUCH PAPER | | DOCUMENTS SO I KNOW TO VERIFY THE REPORT IN PAPER IS | | THE SAME REPORT SUBMITTED ELECTRONICALLY AND VERIFY | | SIGNATURE ON THE PAPER DOCUMENT. | | | | 4A-H) COMPLIED. | | | | 4I) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. WITHIN THE STILLER | | AUDITORIUM THERE IS A PLATFORM LIFT TO GAIN ACCESS TO | | THE LOWER VIEWING AREA. COMPLIANCE FOR THE FLORIDA 2014 | | ACCESSIBILITY CODE FOR VERTICAL ACCESSIBILITY IS BEING | | ACHIEVED BY THE PLATFORM LIFT, ACCESS CODE 207.1 AND AS | | PART OF A MEANS OF EGRESS IT ALSO HAS TO COMPLY WITH | | 1003.2.13 OF THE INTERNATIONAL BUILDING CODE 2000 | | EDITION AND THE 2001 SUPPLEMENT OR SECTION 1007 OF THE | | IBC-B 2003 EDITION. IN THE 2003 IBC-B 1007.5. PLATFORM | | LIFTS (WHEEL CHAIR) SHALL NOT SERVE AS PART OF AN | | ACCESSIBLE MEANS OF EGRESS, EXCEPT WHERE ALLOWED AS | | PART OF A REQUIRED ACCESSIBLE ROUTE IN SECTION 1109.7. | | PLATFORM | | LIFTS IN ACCORDANCE WITH SECTION 2702 SHALL BE | | INSTALLED IN ACCORDANCE WITH ASME A18.1. STANDBY POWER | | SHALL BE PROVIDED FOR THE PLATFORM LIFTS PERMITTED TO | | SERVE AS A PART OF A MEANS OF EGRESS. | | | | 4J) 2ND REQUEST. THE ISSUE IS WITH EXITING, AND AN | | ACCESSIBLE EXIT, NOT JUST FOR THIS ROOM BUT EXITS FOR | | THE WHOLE OF THE BUILDING. THE DRAWING INDEX INDICATES | | SHEET 0260.03_A933_SIGNAGE DETAILS . THE ARE NO DETAILS | | FOR ACCESSIBLE SIGNAGE AND FOR DOORS THAT ARE NOT PART | | OF AN ACCESSIBLE ROUTE. THE HEIGHT OF SIGNAGE THAT HAS | | TACTILE CHARACTERS WITH BRAILLE,2014 FBC-ACCESSIBILITY | | CODE 703.4.1. | | 703.1 SIGNS SHALL COMPLY WITH 703. WHERE BOTH VISUAL | | AND TACTILE CHARACTERS ARE REQUIRED, EITHER ONE SIGN | | WITH BOTH VISUAL AND TACTILE CHARACTERS, OR TWO | | SEPARATE SIGNS, ONE WITH VISUAL, AND ONE WITH TACTILE | | CHARACTERS, SHALL BE PROVIDED. | | 2014 FBC-B 1011.4 RAISED CHARACTER AND BRAILLE EXIT | | SIGNS. A SIGN STATING EXIT IN RAISED CHARACTERS AND | | BRAILLE AND COMPLYING WITH ICC A117.1 SHALL BE PROVIDED | | ADJACENT TO EACH DOOR TO AN AREA OF REFUGE, AN EXTERIOR | | AREA FOR ASSISTED RESCUE, AN EXIT STAIRWAY, AN EXIT | | RAMP, AN EXIT PASSAGEWAY AND THE EXIT DISCHARGE. | | | | 1ST ROUND COMMENTS. THE SOME OF THE EXITS DO NOT | | INDICATE IF THEY ARE ACCESSIBLE EGRESS DOORWAYS | | COMPLYING WITH 2014 FBC-ACCESSIBILITY CODE 207.1 | | ACCESSIBLE MEANS OF EGRESS SHALL COMPLY WITH THE 2003 | | IBC SECTION 1007. 2003 IBC-B 1007.1. WHERE 2 OR MORE | | MEANS OF EGRESS IS REQUIRED BY SECTION 1014.1 OR 1018.1 | | FROM ANY ACCESSIBLE PORTION OF THE SPACE SHALL BE | | SERVED BY NOT LESS THAN TWO ACCESSIBLE MEANS OF EGRESS. | | THE LIFE SAFETY PLAN IS VAGUE AT BEST. 1027.5 ACCESS TO | | A PUBLIC WAY. THE EXIT DISCHARGE SHALL PROVIDE A DIRECT | | AND UNOBSTRUCTED ACCESS TO A PUBLIC WAY. | | | | 5A) COMPLIED. | | | | 5B) 2ND REQUEST. RESPONSE INDICATES THE ENCLOSURE THAT | | CONNECTS THE OCCUPIED SPACE TO THE VERTICAL EXIT | | ENCLOSURE IS 2 HOUR RATED. IS THIS 2 HOUR RATING RATHER | | THAN HAVE A DOOR SEPARATING THE VERTICAL EXIT FROM THIS | | SPACE, ARE YOU LOOKING THIS IS ALTERNATE MATERIALS AND | | DESIGN METHODS? IF SO YOU WOULD NEED TO REQUEST SO IN | | WRITTEN FORM TO THE BUILDING OFFICIAL. 2014 FLORIDA | | BUILDING CODE W 2014 WEST PALM BEACH AMENDMENTS TO THE | | FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION 104.11 | | ALTERNATE MATERIALS, DESIGN AND METHODS OF | | CONSTRUCTION. | | | | 1ST ROUND OF COMMENTS. ON SHEET 0013_LS101M THERE IS A | | VERTICAL EXIT STAIR # 5 AND ADJACENT TO THE STAIR | | CORRIDOR 101M. THERE IS NO EXIT DOOR SEPARATING THE | | VERTICAL EXIT FROM EITHER AN EXIT ACCESS CORRIDOR OR AN | | EXIT PASSAGE WAY. HIS USE APPEARS TO BE AN EXIT ACCESS | | CORRIDOR MISSING THE DOOR TO THE VERTICAL EXIT. | | 2014 FBC-B 1022.4 OPENINGS. INTERIOR EXIT STAIRWAY AND | | RAMP OPENING PROTECTIVES SHALL BE IN ACCORDANCE WITH | | THE REQUIREMENTS OF SECTION 716. SEE TABLE 716.5. | | OPENINGS IN INTERIOR EXIT STAIRWAYS AND RAMPS OTHER | | THAN UNPROTECTED EXTERIOR OPENINGS SHALL BE LIMITED TO | | THOSE NECESSARY FOR EXIT ACCESS TO THE ENCLOSURE FROM | | NORMALLY OCCUPIED SPACES AND FOR EGRESS FROM THE | | ENCLOSURE. | | | | 6A) COMPLIED. 6B) EXISTING CONDITION. | | | | 6C-G) COMPLIED. | | | | 6H) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... 2014 | | FBC-ACCESSIBILITY CODE THE USE OF PLATFORM LIFTS IS | | VERY LIMITED IN THEIR USE IN NEW CONSTRUCTION. PLEASE | | REVIEW THE 2014 FBC-ACCESS. CODE 206.7(1-10). | | | | 6I-6J) COMPLIED. | | | | 7) COMPLIED. | | 8A) 2ND REQUEST. PLEASE CLARIFY IN THE F P DRAWINGS, | | WHICH SHEET COMPLIANCE CAN BE FOUND. SHEET 0171_A510 | | DETAIL DOES PROVIDE A DETAIL FOR THE DRAFT CURTAIN BUT | | AGAIN THERE IS NO MENTION OF CLOSELY SPACED SPRINKLERS | | IN ACCORDANCE WITH NFPA 13. | | | | 9) COMPLIED. | | | | 10) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... SHEET | | 0157_A420 DETAIL # 2 INDICATES THE USE OF FULLY ADHERED | | PVC ROOFING TO 5/8 INCH THERMAL BARRIER THEN METAL | | DECKING. PLEASE IDENTIFY THE 5/8 INCH THERMAL BARRIER | | COMPONENT, SHOW COMPLIANCE WITH FBC-B 603. | | | | 11&12, A-C) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO | | BE SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... | | SHOP DRAWINGS ARE TO BE SUBMITTED FOR THE TYPE OF WALL | | AND CEILING SHEATHING/ PANELING AND OR FOAM AND OR | | FABRIC FINISHES. THERE MAY BE USE OF A FOAM PANEL THE | | PLANS ARE NOT CLEAR, BUT THERE IS FABRIC PANELS AS | | SPECIFIED. PLEASE PROVIDE COMPLIANCE WITH FBC-B | | 803.11.2 SET-OUT CONSTRUCTION. WHERE WALLS AND CEILINGS | | ARE REQUIRED TO BE OF FIRE-RESISTANCE-RATED OR | | NONCOMBUSTIBLE CONSTRUCTION AND WALLS ARE SET OUT OR | | CEILINGS ARE DROPPED DISTANCES GREATER THAN SPECIFIED | | IN SECTION 803.11.1, CLASS A FINISH MATERIALS, IN | | ACCORDANCE WITH SECTION 803.1.1 OR 803.1.2, SHALL BE | | USED. | | | | 13 & 14) COMPLIED. | | | | 15) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... | | SHEETS 0269_FS200 & 0270_FS201 BOTH SHOW KITCHEN | | EXHAUST HOODS REQUIRE A SEPARATE PERMIT. THE SHAFTS | | WOULD BE COVERED UNDER THE BUILDING PERMIT. | | | | 16) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... | | SHEETS 0285_S120.7 & 0286_S120.8 THE WATER FEATURE ALSO | | WILL REQUIRE A SEPARATE PERMIT, SHOW THE SAME DETAIL | | SHEETS UNDER THE ARCHITECTURAL, STRUCTURAL, ELECTRICAL | | & PLUMBING DISCIPLES. | | | | 17) SEMI-COMPLIED. THE SHEETS S008, S009, & S010 ALL | | SHOW THE PRESSURES FROM THE WIND STUDY FOR ROOF ZONES | | 1, 2 & 3. THESE 3 SHEETS LISTED ABOVE S008 IS THE ONLY | | SHEET WHICH SHOWS PRESSURES FOR ROOF ZONES 1, 2 & 3. | | THE ROOF ZONES DO NOT PROVIDE PRESSURES FOR ROOF TOP | | EQUIPMENT THAT WILL BE ANCHORED TO THE (MWFRS) MAIN | | WIND FORCE RESISTING SYSTEM. | | PLEASE PROVIDE THE PRESSURES FOR THE DOORS AND WINDOWS | | IN WALL ZONES 4 & 5. PLEASE PROVIDE THE PRESSURES FOR | | THE WINDOWS AND DOORS AS PER THE WIND STUDY THAT WAS | | COMPLETED. FBC-B 1609.1.1DETERMINATION OF WIND LOADS. | | EXCEPTION #6 WIND TUNNEL TESTING IN ACCORDANCE WITH | | CHAPTER 31 OF ASCE 7. PLEASE NOTE THIS MAY ALSO BE | | ACCOMPLISHED UNDER THE STRUCTURE ONLY PERMIT # | | 16080215. | | 18) 2ND REQUEST. IT SEEMS THE PLANS ARE INCOMPLETE | | PLEASE PROVIDE WHERE THE FOUNDATION SCHEDULE, CONCRETE | | COLUMN, HOOPS & VERTICAL REBAR AND BEAMS ARE LOCATED, I | | COULD NOT FIND THEM IN THE STRUCTURAL SHEETS. | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR | | BUILDINGS. | | 107.3.5.1.1. COMMERCIAL BUILDINGS/ BUILDING: | | FOUNDATION SCHEDULE | | COLUMN SCHEDULE | | BEAM ( CONCRETE/ LINTEL) SCHEDULE | | | | 19) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... | | 19) MISSING PRODUCT APPROVALS. 2010/ 2014 FBC-B | | 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.4.1 | | COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY | | AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF | | PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE | | PRODUCT APPROVALS: | | (31)(A) EXTERIOR DOORS. | | (B) WINDOWS | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | LOUVERS, EFIS SYSTEMS, | | (D) ROOFING PRODUCTS AND ASSEMBLIES | | (E) SHUTTERS | | (F) SKYLIGHTS | | | | 20) PROVISO: ADMINISTRATION 107.3.4 DESIGN PROFESSIONAL | | IN RESPONSIBLE CHARGE. THE REGISTERED DESIGN | | PROFESSIONAL IN RESPONSIBLE CHARGE SHALL BE RESPONSIBLE | | FOR REVIEWING AND COORDINATING SUBMITTAL DOCUMENTS | | PREPARED BY OTHERS, INCLUDING PHASED AND DEFERRED | | SUBMITTAL ITEMS, FOR COMPATIBILITY WITH THE DESIGN OF | | THE BUILDING. THOSE PRODUCTS WHICH ARE REGULATED BY DCA | | RULE 9N-3SHALL BE REVIEWED AND APPROVED IN WRITING BY | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL. | | | | 21) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... | | ROOFING: FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY ALL | | ROOFING SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES FOR | | ROOF ZONE # 1. REVIEW THE PRODUCT APPROVAL LIMITATIONS, | | IF ENHANCED FASTENING IS ALLOWED FOR ROOF ZONES 2 & 3. | | IF SO RAS 117 CALCULATIONS ARE REQUIRED BY EITHER A | | FLORIDA ARCHITECT OR ENGINEER. | | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED TO | | DETERMINE CODE COMPLIANCE. 2014 FBC-B 1603.1.4 WIND | | DESIGN DATA. | | | | 22) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... | | 2014 FBC-M- 301.15 WIND RESISTANCE. MECHANICAL | | EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO | | WIND SHALL BE DESIGNED AND INSTALLED TO RESIST THE WIND | | PRESSURES DETERMINED IN ACCORDANCE WITH THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 23) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... | | FBC-B 1013.7 ROOF ACCESS. GUARDS SHALL BE PROVIDED | | WHERE THE ROOF HATCH OPENING IS LOCATED WITHIN 10 FEET | | (3048 MM) OF A ROOF EDGE OR OPEN SIDE OF A WALKING | | SURFACE AND SUCH EDGE OR OPEN SIDE IS LOCATED MORE THAN | | 30 INCHES (762 MM) ABOVE THE FLOOR, ROOF OR GRADE | | BELOW. THE GUARD SHALL BE CONSTRUCTED SO AS TO PREVENT | | THE PASSAGE OF A SPHERE 21 INCHES (533 MM) IN DIAMETER. | | | | 24) PROVISO: DEFERRED SUBMITTAL 107. 3.4.3 TO BE | | SUBMITTED AFTER PERMIT ISSUANCE. SHOP DRAWING TO BE | | SUBMITTED AND REVIEWED AND STAMPED APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD BEFORE SUBMITTAL TO THE | | BUILDING DEPARTMENT. FL 61G1-23.015 (2) THE ARCHITECT | | IS RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL | | PROJECT DATA, REPORTS, SHOP DRAWINGS ETC... | | FBC-B 1509.6.1 HEIGHT LIMITATIONS. MECHANICAL EQUIPMENT | | SCREENS SHALL NOT EXCEED 18 FEET (5486 MM) IN HEIGHT | | ABOVE THE ROOF DECK, AS MEASURED TO THE HIGHEST POINT | | ON THE MECHANICAL EQUIPMENT SCREEN. | | | | 25) NEW COMMENT. TYPE IB & IIA BUILDING REQUIRE FIRE | | RESISTANCE RATING FOR BUILDING ELEMENTS PER TABLE 601 | | OF THE 2014 FBC-B. PLEASE PROVIDE COMPLIANCE WITH THIS | | SECTION OF THE CODE. THANK YOU. | | | | 26 ) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-07-11 |
|
|
Cont ID |
|
Sent By |
|
Date |
2016-07-11 |
Time |
07:59 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-07-07 |
Time |
10:30 |
Sent To |
|
|
Notes |
2016-07-11 07:43:15 | BUILDING PLAN REVIEW | | NORTON MUSEUM | | W. P. B. PERMIT: 16050912 | | ADD: 1451 S. OLIVE AVE. | | CONT: GILBANE | | TEL: 561-236-7052 | | E-MAIL: [email protected] MICHAEL IZZO | | [email protected] MICHAEL J BEAUMIER | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: SAT. JULY 09/ 2016 | | ACTION: DENIED | | | | 1) PLEASE BE AWARE THIS SCOPE OF WORK REQUIRES A | | THRESHOLD INSPECTOR, SEE F.S. THRESHOLD BUILDING FL S. | | S. 553.71(7) ?THRESHOLD BUILDING" MEANING ANY BUILDING | | WHICH IS GREATER THAN (3) STORIES OR 50 FT. IN HEIGHT, | | OR WHICH HAS AN ASSEMBLY OCCUPANCY CLASSIFICATION AS | | DENIED IN THE FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 | | SQ. FT. IN AREA AND AN OCCUPANT CONTENT OF GREATER THAN | | 500 PERSONS. | | | | 1A) 109.3.6.1 THRESHOLD INSPECTION PLAN. THE ENFORCING | | AGENCY SHALL REQUIRE A (WRITTEN/ TYPED) SPECIAL | | INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A | | THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION | | PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL | | INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING | | AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR | | THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE | | OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE | | SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT | | THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE | | WITH THE PERMITTED DOCUMENTS. | | | | 1B) THRESHOLD INSPECTOR: WPB AMENDMENT 109.3.6.2 W.P.B. | | CONSTRUCTION SERVICES DEPARTMENT REQUESTS FOR THRESHOLD | | BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY FL S | | 553.79(5) FLORIDA STATUTES TO THE MINIMUM INSPECTIONS | | REQUIRED BY THIS CODE. THE THRESHOLD INSPECTION FORMS | | ARE REQUIRED TO BE FILED OUT BY ALL PARTIES WITH | | INTEREST, NOTARIZED AND RETURNED TO THIS OFFICE, AND | | REVIEWED AND APPROVED BEFORE PERMIT ISSUANCE WILL TAKE | | PLACE. | | THE THRESHOLD INSPECTION FORMS WERE SENT TO: | | [email protected] MICHAEL IZZO 07/09/2016 7:24 AM | | [email protected] MICHAEL J BEAUMIER 07/09/2016 | | 7:37 AM | | | | 1C) THRESHOLD BLDG., REQUIRED STATEMENT: W.P.B. | | AMENDMENT 110.3.7.4.4 ALL PLANS FOR THE BUILDING WHICH | | ARE REQUIRED TO BE SIGNED AND SEALED BY THE ARCHITECT | | OR ENGINEER OF RECORD CONTAIN A STATEMENT THAT, TO THE | | BEST OF THE ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE | | PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE | | FIRE-SAFETY STANDARDS AS DETERMINED BY THE LOCAL | | AUTHORITY IN ACCORDANCE WITH THIS SECTION AND 633 | | FLORIDA STATUTE. | | | | 1D) 110.3.7.4.3 ALL SHORING AND RESHORING PROCEDURES, | | PLANS AND DETAILS SHALL BE SUBMITTED TO THE ENFORCEMENT | | AGENCY FOR RECORDKEEPING. EACH SHORING AND RESHORING | | INSTALLATION SHALL BE SUPERVISED, INSPECTED AND | | CERTIFIED TO BE IN COMPLIANCE WITH THE SHORING | | DOCUMENTS BY THE CONTRACTOR. | | | | 1D) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME' | | OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE | | RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS | | SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE | | WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, | | AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES | | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST | | MEETING THE ABOVE CRITERIA. | | | | 1E) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR | | HISTORY FOR THIS TYPE OF CONSTRUCTION. | | | | 1F) NOTE FOR PAPER PLANS 3 SETS OF DOCUMENTS ARE | | REQUIRED. FOR DIGITAL PLANS, AFTER PERMIT ISSUANCE, | | PLEASE E-MAIL THE PERMIT LIBRARIAN OF THE PERMIT BEING | | ISSUED, THE PERMIT LIBRARIAN WILL THEN E-MAIL YOU THE | | APPROVED AND BATCH STAMPED PLANS SO YOU MAY PRINT YOUR | | PLANS, TWO SETS OF PLANS WILL NEED TO BE PRINTED IN | | COLOR, (1) FOR THE THRESHOLD INSPECTOR, THE OTHER FOR | | THE MEP INSPECTORS OTHER PLANS YOU WISH TO PRINT MAYBE | | IN BLACK & WHITE.. | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | CODE, CHAPTER 1, ADMINISTRATION, 110.3.7 THRESHOLD | | BUILDINGS, GUIDELINES AND POLICIES FOR PROJECTS | | CONCERNING SPECIAL INSPECTORS. | | | | 1G) PLEASE CALL THE CITY OF WEST PALM BEACH?S AUTOMATED | | TELEPHONE INSPECTIONS LINE (561) 805-6700) FOR ALL | | BUILDING INSPECTIONS FOR AUDITING OF JOBSITE | | INSPECTIONS WITHOUT THIS THE PERMIT EXPIRES IN 6 | | MONTHS, ABANDONMENT OF JOB, NO INSPECTION ACTIVITY. | | | | 1H) 109.3.6 THRESHOLD BUILDINGS, OPERATING GUIDELINES | | FOR THRESHOLD INSPECTORS #26. ASSURE THAT THE DESIGNER | | HAS REQUIRED ON THE PLANS OR SPECIFICATIONS ONE | | MATERIAL, APPROVED FOR FIRE STOPPING PENETRATIONS, FOR | | WALLS AND CEILINGS. | | | | 2) SHEET 0277_S003 HEADING FOUNDATIONS INDICATES THERE | | WAS A GEOTECHNICAL REPORT COMPLETED BY ARDAMAN | | 12/16/2014. PLEASE SUBMIT REPORT. NOTE WHEN SUBMITTED | | ELECTRONICALLY THE SOILS ENGINEER WILL NEED TO SUBMIT | | UNDER AN ELECTRONIC SEAL PER 61G15-23.005 PROCEDURES | | FOR SIGNING AND SEALING ELECTRONICALLY TRANSMITTED | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS | | (ELECTRONIC SEALS). | | OTHERWISE ONE PAPER ORIGINAL SIGNED AND SEALED DOCUMENT | | WILL BE RETAINED AND SCANNED INTO THE SYSTEM. | | | | 3) UNDER SHEET 0008_A0004 THE PHASING PLAN THE PLANS | | SHOW EXISTING AND THE EXPANSION PLAN. PLEASE PROVIDE | | THE EXISTING TOTAL SQUARE FOOTAGE OF THE BUILDING AND | | THE TOTAL SQUARE FOOTAGE OF THE BUILDING AT THE END OF | | THIS EXPANSION. THIS INFORMATION WILL BE REQUIRED BY | | PALM BEACH COUNTY IMPACT FEE OFFICE TO DETERMINE IF | | IMPACT FEES ARE DUE. 107.2.1.3 ADDITIONAL INFORMATION | | IS REQUIRED. | | | | 4) SHEET 0012_ LS101 VERSES 0097_A101; | | | | 4A) THE LIFE SAFETY PLAN SEEMS INCOMPLETE, IT APPEARS | | THERE ARE EXISTING AREAS OF THE MUSEUM AND PORTIONS | | THAT ARE GOING TO BE REMODELED THAT PROVIDE THE SQUARE | | FOOTAGE OF THE ROOM AND OCCUPANT LOADS BUT THERE IS NO | | ROOM NUMBER TO BE ABLE TO IDENTIFY THE ROOM. | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | OFFICIAL. | | | | 4B) THE LIFE SAFETY PLANS CHARTS SHOWING EXIT CAPACITY | | AND OCCUPANT LOADS BUT THE PLAN DOES NOT SHOW | | THE EGRESS PATH FOR 50 % OF THE BUILDING. WHERE THE | | ROOMS THAT DO SHOW WHAT AMOUNT OF OCCUPANTS THAT ARE | | EXITING A ROOM, THEY DO NOT GIVE AN ACCUMULATIVE | | OCCUPANT LOAD OF THE EXIT ACCESS CORRIDORS, TO THE | | EXIT. DOOR SWINGS CANNOT BE EVALUATED BECAUSE THE PATH | | OF TRAVEL AND OCCUPANT LOADS IS UNKNOWN. FBC-B 1005.2 | | MINIMUM WIDTH BASED ON COMPONENT. THE MINIMUM WIDTH, IN | | INCHES (MM), OF ANY MEANS OF EGRESS COMPONENTS SHALL | | NOT BE LESS THAN THAT SPECIFIED FOR SUCH COMPONENT, | | ELSEWHERE IN THIS CODE. | | | | 4C) ROOM 120 THE EMILY & LEONARD LAUDER RESTAURANT | | INDICATES 3511 SQ. FT. AND AN OCCUPANT LOAD OF 235 IN | | THE LS101 SHEET. WHEREAS IN THE OCCUPANT LOAD CHART | | THIS SAME ROOM SHOWS 3,736 SQ. FT. AND AN OCCUPANT LOAD | | OF250.EVEN IF YOU FIGURE THE PRIVATE DINING ROOM 121 | | THE SQ. FOOTAGE TOTALS UP TO 4286 SQ. FT. THERE IS A | | DISCREPANCY IN THE OCCUPANT LOADS FOR BOTH OF THESE | | ROOMS. THE PRIVATE DINING ROOM OF 775 SQ. FT. /15= 52 | | OCCUPANTS NOT 49. THERE IS A DISCREPANCY IN THE PLANS. | | SEE FBC-B TABLE 1004.1.2. | | | | 4D) WITHIN THIS SAME AREA ROOMS 120 & 121 THE TOTAL | | OCCUPANT LOAD 235 + 52 = 287 OCCUPANTS. THE PLANS ONLY | | ACCOUNT FOR 167 OCCUPANTS OF THE 287 OCCUPANT LOAD, | | THERE ARE 120 OCCUPANTS NOT ACCOUNTED FOR. PLEASE ALSO | | NOTE IN THE PRIVATE DINING ROOM 121 LABELED 49 | | OCCUPANTS WHICH SHOULD BE 775/15= 52 OCCUPANTS. THE | | PLAN SHOWS ALL EXITING THROUGH ONE DOORWAY. PLEASE | | REVIEW THE 2014 FBC-B TABLE 1015.1 THE MAXIMUM | | ALLOWABLE WITH ONE EXIT IS 49 FOR ASSEMBLY OCCUPANCY. | | IF THE OCCUPANCY WAS FIGURED ON THE 775 SQ. FT. AS A | | NET @ 15 FT./OCCUPANT THEN THE OCCUPANT LOAD IS 52 | | REQUIRING 2 EXITS, NOT PROVIDED. | | | | 4E) ROOM 118 THE RESTAURANT LOBBY AREA DOES NOT HAVE AN | | OCCUPANT LOAD FIGURED IN, THE PLANS DO NOT INDICATE IF | | THIS IS A PRE-FUNCTION AREA WHERE THERE WOULD POSSIBLY | | BE A QUEUING LINE WHERE AN AREA WOULD BE ROPED OFF WITH | | BOLLARDS, THE EGRESS PATH IS UNKNOWN IN THIS CASE? THE | | OTHER UNKNOWN IS ROOM 119 SALTMAN CORRIDOR WHERE ARE | | THESE OCCUPANTS EXITING. FBC-B 1028.4 THIS SECTION IS | | FOR A-1 ASSEMBLY BUT MAYBE A SIMILAR TYPE USE. | | | | 4F) AREA OF CONCERN WITH STAIR #2 AND EXIT C. THE 1ST | | FLOOR PLAN SHOWS A OCCUPANT LOAD OF 135 BEING TAKEN | | FROM THE 2ND FLOOR WORST CASE SCENARIO FLOOR DOWN THIS | | STAIR. THE EXIT DOOR C IS MAXED OUT AT 340/ 340 | | OCCUPANT LOAD. WHEN VIEWING ON SHEET 0014_LS 102 THE | | TOTAL OCCUPANT LOAD OF THE 2ND FLOOR OF 463 THERE IS | | ONLY 443 OCCUPANTS ACCOUNTED FOR IN THE (4) STAIR | | WELLS, STAIR 1 (136 OCC.), STAIR 2 (135) STAIR 4 (68) | | AND STAIR 5(104), 136 + 135 + 68 + 104= 443 OCCUPANTS/ | | SHORT 20 OCCUPANTS IN THE STAIRWELLS!!!! ALTHOUGH | | STAIRWELL # 2 COULD ACCOMMODATE MORE OCCUPANTS THE | | LIMITING FACTOR IS AT EXIT DOOR C, IS FULL 340/ 340 | | OCCUPANTS. SEE FBC-B 1005.3.2 AND ALSO THE EXCEPTION. | | | | 4G) CLOAK ROOM NOR CLOSETS SHOW OCCUPANT LOADS. FBC-B | | TABLE 1004.1.2. | | | | 4H) THE COMBINATION FOYERS/ VESTIBULE 110 & 145 SHOW AN | | OCCUPANT LOAD OF ONLY 9. THIS AREA MAY ALSO BE A | | QUEUING AREA FOR THE A1 THEATER OCCUPANCY. THE PLANS DO | | NOT INDICATE IF THIS IS TO BE A PRE-FUNCTION AREA WHERE | | THERE WOULD POSSIBLY BE A QUEUING LINE WHERE AN AREA | | WOULD BE ROPED OFF WITH BOLLARDS; THE EGRESS PATH IS | | UNKNOWN IN THIS CASE? FBC-B 1028.4 THIS SECTION IS FOR | | A-1 ASSEMBLY USAGE. | | | | 4I) WITHIN THE STILLER AUDITORIUM THERE IS A PLATFORM | | LIFT TO GAIN ACCESS TO THE LOWER VIEWING AREA. | | COMPLIANCE FOR THE FLORIDA 2014 ACCESSIBILITY CODE FOR | | VERTICAL ACCESSIBILITY IS BEING ACHIEVED BY THE | | PLATFORM LIFT, ACCESS CODE 207.1 AND AS PART OF A MEANS | | OF EGRESS IT ALSO HAS TO COMPLY WITH 1003.2.13 OF THE | | INTERNATIONAL BUILDING CODE 2000 EDITION AND THE 2001 | | SUPPLEMENT OR SECTION 1007 OF THE IBC-B 2003 EDITION. | | IN THE 2003 IBC-B 1007.5. PLATFORM LIFTS (WHEEL CHAIR) | | SHALL NOT SERVE AS PART OF AN ACCESSIBLE MEANS OF | | EGRESS, EXCEPT WHERE ALLOWED AS PART OF A REQUIRED | | ACCESSIBLE ROUTE IN SECTION 1109.7. PLATFORM | | LIFTS IN ACCORDANCE WITH SECTION 2702 SHALL BE | | INSTALLED IN ACCORDANCE WITH ASME A18.1. STANDBY POWER | | SHALL BE PROVIDED FOR THE PLATFORM LIFTS PERMITTED TO | | SERVE AS A PART OF A MEANS OF EGRESS. | | | | 4J) THE SOME OF THE EXITS DO NOT INDICATE IF THEY ARE | | ACCESSIBLE EGRESS DOORWAYS COMPLYING WITH 2014 | | FBC-ACCESSIBILITY CODE 207.1 ACCESSIBLE MEANS OF EGRESS | | SHALL COMPLY WITH THE 2003 IBC SECTION 1007. 2003 IBC-B | | 1007.1. WHERE 2 OR MORE MEANS OF EGRESS IS REQUIRED BY | | SECTION 1014.1 OR 1018.1 FROM ANY ACCESSIBLE PORTION OF | | THE SPACE SHALL BE SERVED BY NOT LESS THAN TWO | | ACCESSIBLE MEANS OF EGRESS. THE LIFE SAFETY PLAN IS | | VAGUE AT BEST. 1027.5 ACCESS TO A PUBLIC WAY. THE EXIT | | DISCHARGE SHALL PROVIDE A DIRECT AND UNOBSTRUCTED | | ACCESS TO A PUBLIC WAY. | | | | 5) SHEET 0013_LS101M & 0098_A101M: | | | | 5A) ON SHEET 0013_LS101M JUST TO THE RIGHT OF CORRIDOR | | 101M THERE IS A SMALL ROOM AND DOOR. THERE IS ALSO A | | NOTE ON THE PLANS PLEASE CLARIFY ROOM AND DOOR | | ARRANGEMENT. 107.2.1.3 ADDITIONAL INFORMATION IS | | REQUIRED. | | | | 5B) ON SHEET 0013_LS101M THERE IS A VERTICAL EXIT STAIR | | # 5 AND ADJACENT TO THE STAIR CORRIDOR 101M. THERE IS | | NO EXIT DOOR SEPARATING THE VERTICAL EXIT FROM EITHER | | AN EXIT ACCESS CORRIDOR OR AN EXIT PASSAGE WAY. HIS USE | | APPEARS TO BE AN EXIT ACCESS CORRIDOR MISSING THE DOOR | | TO THE VERTICAL EXIT. | | 2014 FBC-B 1022.4 OPENINGS. INTERIOR EXIT STAIRWAY AND | | RAMP OPENING PROTECTIVES SHALL BE IN ACCORDANCE WITH | | THE REQUIREMENTS OF SECTION 716. SEE TABLE 716.5. | | OPENINGS IN INTERIOR EXIT STAIRWAYS AND RAMPS OTHER | | THAN UNPROTECTED EXTERIOR OPENINGS SHALL BE LIMITED TO | | THOSE NECESSARY FOR EXIT ACCESS TO THE ENCLOSURE FROM | | NORMALLY OCCUPIED SPACES AND FOR EGRESS FROM THE | | ENCLOSURE. | | | | 6) SHEET 0014_LS102 & 0099_A102: | | | | 6A) BETWEEN THE 2 SHEETS THERE IS A DISCREPANCY IN THE | | STAIR IDENTIFICATION NUMBER LS SHEET LIST STAIR AS | | STAIR # 01 WHEREAS 0099_A102 ON GRIDLINES X3 5.3X XF-3 | | IDENTIFIES THE STAIR AS STAIR # 3 B217. DISCREPANCY IN | | PLANS. 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | 6B) THE LOWER RIGHT CORNER OF THE PLAN STAIR LABEL BOTH | | 1 & 3 HAVE (2) OTHER ROOMS WITHIN THE VERTICAL STAIR | | ENCLOSURE. ONE NOT LABELED THE OTHER B215 SECURITY | | CLOSET. PLEASE REVIEW THE 2014 FBC-B 1022.4 OPENINGS. | | INTERIOR EXIT STAIRWAY AND RAMP OPENING PROTECTIVES | | SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION | | 716. OPENINGS IN INTERIOR EXIT STAIRWAYS OTHER THAN | | UNPROTECTED EXTERIOR OPENINGS SHALL BE LIMITED TO THOSE | | NECESSARY FOR EXIT ACCESS TO THE ENCLOSURE FROM | | NORMALLY OCCUPIED SPACES AND FOR EGRESS FROM THE | | ENCLOSURE. ELEVATORS SHALL NOT OPEN INTO INTERIOR EXIT | | STAIRWAYS AND RAMPS. | | | | 6C) THE 2ND FLOOR IS OPEN TO THE 1ST FLOOR IN THE GRAND | | HALL AND ADMISSIONS. PLEASE PROVIDE A NORTH / SOUTH | | SECTION THROUGH THE CENTER OF THIS AREA. SHEET 0099 THE | | 2ND FLOOR SHOWS WHAT APPEARS TO BE A 2 STORY ATRIUM. | | THE LIFE SAFETY PLAN 0014 THE 2ND FLOOR SHOWS A SMOKE | | PARTITION RATED WALL. THE SHEET 0015_LS 103 THE 3RD | | STORY SHOWS A SMOKE RATED PARTITION DOWN TO THE 2ND | | FLOOR. IF THIS IS A 3 STORY ATRIUM THEN COMPLIANCE WITH | | 404.4 & 404.5. | | | | 6D) 2014 FBC-B 404.4 FIRE ALARM SYSTEM. A FIRE ALARM | | SYSTEM SHALL BE PROVIDED IN ACCORDANCE WITH SECTION | | 907.2.14. | | | | 404.5 SMOKE CONTROL. A SMOKE CONTROL SYSTEM SHALL BE | | INSTALLED IN ACCORDANCE WITH SECTION 909. | | EXCEPTION: SMOKE CONTROL IS NOT REQUIRED FOR ATRIUMS | | THAT CONNECT ONLY TWO STORIES. | | | | 6E) THE OTHER ISSUE IS THE PLANS CALL OUT FOR THE | | PARTITIONS ON THE 2ND AND 3RD FLOORS TO BE SMOKE | | PARTITIONS. | | THE PLANS DO NOT INDICATE THERE WILL BE A SMOKE CONTROL | | SYSTEM FBC-B 404.6 EXCEPTION # 3 DIES STATE: | | A FIRE BARRIER IS NOT REQUIRED BETWEEN THE ATRIUM AND | | THE ADJOINING SPACES OF ANY THREE FLOORS OF THE ATRIUM | | PROVIDED SUCH SPACES ARE ACCOUNTED FOR IN THE DESIGN OF | | THE SMOKE CONTROL SYSTEM. | | | | 6F) FOR THE ATRIUM SMOKE CONTROL SYSTEM WILL ALSO NEED | | TO COMPLY WITH: FBC-B 404.7 STANDBY POWER. EQUIPMENT | | REQUIRED TO PROVIDE SMOKE CONTROL SHALL BE CONNECTED TO | | A STANDBY POWER SYSTEM IN ACCORDANCE WITH SECTION | | 909.11. | | | | 6G) FBC-B 404.8 ATRIUM. INTERIOR FINISH. THE INTERIOR | | FINISH OF WALLS AND CEILINGS OF THE ATRIUM SHALL BE NOT | | LESS THAN CLASS B WITH NO REDUCTION IN CLASS FOR | | SPRINKLER PROTECTION. | | | | 6H)(1) THE PLANS INDICATE THE USE OF A LULA ELEVATOR | | FROM CORRIDOR 216 TO THE LIBRARY 220. WITH IN THIS | | SPACE THERE IS A SET OF STAIRS. PLEASE IDENTIFY IF THIS | | IS NEW CONSTRUCTION OR MODIFICATIONS TO EXISTING | | CONSTRUCTION. WITHIN THE 2014 FBC-ACCESSIBILITY CODE | | THE USE OF PLATFORM LIFTS IS VERY LIMITED IN THEIR USE | | IN NEW CONSTRUCTION. PLEASE REVIEW THE 2014 FBC-ACCESS. | | CODE 206.7(1-10). | | | | 6H)(2) IF ALLOWED AS PART OF A RENOVATION PROJECT THEN | | SHOW COMPLIANCE WITH: FLORIDA 2014 ACCESSIBILITY CODE | | FOR VERTICAL ACCESSIBILITY IS BEING ACHIEVED BY THE | | PLATFORM LIFT, ACCESS CODE 207.1 AND AS PART OF A MEANS | | OF EGRESS IT ALSO HAS TO COMPLY WITH 1003.2.13 OF THE | | INTERNATIONAL BUILDING CODE 2000 EDITION AND THE 2001 | | SUPPLEMENT OR SECTION 1007 OF THE IBC-B 2003 EDITION. | | IN THE 2003 IBC-B 1007.5. PLATFORM LIFTS (WHEEL CHAIR) | | SHALL NOT SERVE AS PART OF AN ACCESSIBLE MEANS OF | | EGRESS, EXCEPT WHERE ALLOWED AS PART OF A REQUIRED | | ACCESSIBLE ROUTE IN SECTION 1109.7. PLATFORM LIFTS IN | | ACCORDANCE WITH SECTION 2702 SHALL BE INSTALLED IN | | ACCORDANCE WITH ASME A18.1. STANDBY POWER SHALL BE | | PROVIDED FOR THE PLATFORM LIFTS PERMITTED TO SERVE AS A | | PART OF A MEANS OF EGRESS. | | | | 6I) DISCREPANCY IN IDENTIFICATION OF STAIRS, SHEET | | 0014_LS102 IDENTIFIES THE STAIR AS 05 WHERE AS SHEET | | 0099_A102 IDENTIFIES THE SAME STAIR AS 1A. 107.2.1.3 | | ADDITIONAL INFORMATION REQUIRED. | | | | 6J) WITHIN THE SAME STAIR IDENTIFIED ABOVE THE TOP | | LANDING THERE IS A DOOR NOT IDENTIFIED BUT DOES NOT | | HAVE THE 18 INCHES MANEUVERING CLEARANCES ON THE INSIDE | | OF THE DOOR. ACCESS. CODE 404.2.4. | | | | 7) SHEET 0015_LS103 & 0100_A103: | | | | 7A) AGAIN ON THE LIFE SAFETY SHEET IN THE LOWER RIGHT | | HAND CORNER THE STAIRWELL IS LABELED STAIR 1 & 3. | | DISCREPANCY IN PLANS. 107.2.1.3 ADDITIONAL INFORMATION | | IS REQUIRED. | | | | 8) GRAND STAIR CASE, STAIR # 2 IS A OPEN STAIR AS | | ALLOWED BY FBC-B 1009.3 EXCEPTION # 4. SHEETS 0014 & | | 0015 DUE INDICATE THE USE OF DRAFT STOP WITH FIRE | | SPRINKLERS, SHEET 0012 THE 1ST FLOOR THERE IS NO | | MENTION OF A DRAFT CURTAIN OR FIRE SPRINKLERS. PLEASE | | SHOW COMPLIANCE WITH FBC-B 1009.3 EXC. # 4. | | | | 8A) SHEET 0171_A510 DETAIL DOES PROVIDE A DETAIL FOR | | THE DRAFT CURTAIN BUT AGAIN THERE IS NO MENTION OF | | CLOSELY SPACED SPRINKLERS IN ACCORDANCE WITH NFPA 13. | | 8B) SHEET 0166_A503 GRAND STAIR SECTION DETAIL 1 DOES | | NOT EVEN SHOW A DRAFT CURTAIN ON THE 3RD FLOOR. | | SHOW COMPLIANCE WITH: FBC-B 1009.3 EXC. # 4. IN OTHER | | THAN GROUP B AND M OCCUPANCIES, EXIT ACCESS STAIRWAY | | OPENINGS ARE NOT REQUIRED TO BE ENCLOSED PROVIDED THAT | | THE BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC | | SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1, | | THE FLOOR OPENING DOES NOT CONNECT MORE THAN FOUR | | STORIES, THE AREA OF THE FLOOR OPENING BETWEEN STORIES | | DOES NOT EXCEED TWICE THE HORIZONTAL PROJECTED AREA OF | | THE EXIT ACCESS STAIRWAY, AND THE OPENING IS PROTECTED | | BY A DRAFT CURTAIN AND CLOSELY SPACED SPRINKLERS IN | | ACCORDANCE WITH NFPA 13. | | | | 9) SHEET 0228_A806 DOOR SCHEDULE: DOOR C310A MISSING 90 | | MIN. LABEL. FBC-B TABLE 716.5 OPENING PROTECTIVES. | | | | 10) SHEET 0157_A420 DETAIL # 2 INDICATES THE USE OF | | FULLY ADHERED PVC ROOFING TO 5/8 INCH THERMAL BARRIER | | THEN METAL DECKING. PLEASE IDENTIFY THE 5/8 INCH | | THERMAL BARRIER COMPONENT, SHOW COMPLIANCE WITH FBC-B | | 603. | | | | 11)SHEET 0173_ A601 RFC & SHEET 0258_A921 AUDITORIUM | | CEILING DETAILS: | | | | 11A) DETAILS THIS SHEET SHOW A DROPPED DOWN CEILING | | FRAMING SYSTEM. THESE DETAILS DO NOT INDICATE THE | | MATERIALS OF THE FRAMING IS MADE FROM SIZE NOR SPACING. | | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | 11B) DETAILS THIS SHEET SHOW A DROPPED DOWN CEILING BUT | | NO REFERENCE TO THE THICKNESS OF THE CEILING BOARD, | | TYPE OF MATERIAL, ETC? 107.3.5.1.1. 11 INTERIOR | | FINISHES. 803.11.2 SET-OUT CONSTRUCTION. | | | | 11C) THERE MAYBE USE OF A FOAM PANEL THE PLANS ARE NOT | | CLEAR, BUT THERE IS FABRIC PANELS AS SPECIFIED. PLEASE | | PROVIDE COMPLIANCE WITH FBC-B 803.11.2 SET-OUT | | CONSTRUCTION. WHERE WALLS AND CEILINGS ARE REQUIRED TO | | BE OF FIRE-RESISTANCE-RATED OR NONCOMBUSTIBLE | | CONSTRUCTION AND WALLS ARE SET OUT OR CEILINGS ARE | | DROPPED DISTANCES GREATER THAN SPECIFIED IN SECTION | | 803.11.1, CLASS A FINISH MATERIALS, IN ACCORDANCE WITH | | SECTION 803.1.1 OR 803.1.2, SHALL BE USED. | | | | 12) SHEET 0173_A601 AUDITORIUM WALLS & SHEET 0255_A918: | | | | 12A) BUILT OUT WALL DETAILS AS BEFORE COMMENTS, DO NOT | | INDICATE THE FRAMING MATERIAL SIZE NOR SPACING OF THE | | FRAMING MEMBERS. 107.2.1.3 ADDITIONAL INFORMATION IS | | REQUIRED. | | | | 12B) ) DETAILS THIS SHEET SHOW A BUILT OUT WALL DETAILS | | BUT NO REFERENCE TO THE THICKNESS OF THE WALL BOARD, | | TYPE OF MATERIAL, ETC? 107.3.5.1.1. 11 INTERIOR | | FINISHES. 803.11.2 SET-OUT CONSTRUCTION. | | | | 12C) THERE MAYBE USE OF A FOAM PANEL THE PLANS ARE NOT | | CLEAR, BUT THERE IS FABRIC PANELS AS SPECIFIED. PLEASE | | PROVIDE COMPLIANCE WITH FBC-B 803.11.2 SET-OUT | | CONSTRUCTION. WHERE WALLS AND CEILINGS ARE REQUIRED TO | | BE OF FIRE-RESISTANCE-RATED OR NONCOMBUSTIBLE | | CONSTRUCTION AND WALLS ARE SET OUT OR CEILINGS ARE | | DROPPED DISTANCES GREATER THAN SPECIFIED IN SECTION | | 803.11.1, CLASS A FINISH MATERIALS, IN ACCORDANCE WITH | | SECTION 803.1.1 OR 803.1.2, SHALL BE USED. | | | | 13) SHEET 0260_A930 ALL DETAILS SHOW ELECTRICAL FLOOR | | BOXES LOCATED IN CONCRETE STRUCTURAL SLABS WITH WOOD | | STRINGER BUILT UP FLOORING HEIGHT NOT GIVEN, WITH 2 | | LAYERS OF SUB-FLOORING NOT IDENTIFIED. SHOW COMPLIANCE | | WITH 2014 FBC-B SECTIONS: | | | | 805.1 APPLICATION. COMBUSTIBLE MATERIALS INSTALLED ON | | OR EMBEDDED IN FLOORS OF BUILDINGS OF TYPE I OR II | | CONSTRUCTION SHALL COMPLY WITH SECTIONS 805.1.1 THROUGH | | 805.1.3. | | EXCEPTION: STAGES AND PLATFORMS CONSTRUCTED IN | | ACCORDANCE WITH SECTIONS 410.3 AND 410.4, RESPECTIVELY. | | | | 805.1.1 SUBFLOOR CONSTRUCTION. FLOOR SLEEPERS, BUCKS | | AND NAILING BLOCKS SHALL NOT BE CONSTRUCTED OF | | COMBUSTIBLE MATERIALS, UNLESS THE SPACE BETWEEN THE | | FIRE-RESISTANCE-RATED FLOOR ASSEMBLY AND THE FLOORING | | IS EITHER SOLIDLY FILLED WITH NONCOMBUSTIBLE MATERIALS | | OR FIREBLOCKED IN ACCORDANCE WITH SECTION 718, AND | | PROVIDED THAT SUCH OPEN SPACES SHALL NOT EXTEND UNDER | | OR THROUGH PERMANENT PARTITIONS OR WALLS. | | | | 805.1.2 WOOD FINISH FLOORING. WOOD FINISH FLOORING IS | | PERMITTED TO BE ATTACHED DIRECTLY TO THE EMBEDDED OR | | FIREBLOCKED WOOD SLEEPERS AND SHALL BE PERMITTED WHERE | | CEMENTED DIRECTLY TO THE TOP SURFACE OF | | FIRE-RESISTANCE-RATED FLOOR ASSEMBLIES OR DIRECTLY TO A | | WOOD SUBFLOOR ATTACHED TO SLEEPERS AS PROVIDED FOR IN | | SECTION 805.1.1. | | | | 14) SHEETS 0269_FS200 & 0270_FS201 BOTH SHOW KITCHEN | | EXHAUST HOODS THAT VENT UP THROUGH THE ROOF USUALLY. | | NOTE NONE OF THE FLOOR SHEETS SHOW A RATED SHAFT GOING | | FROM FLOOR THROUGH TO THE ROOF. 2014 FBC-B 713.1 | | GENERAL. THE PROVISIONS OF THIS SECTION SHALL APPLY TO | | SHAFTS REQUIRED TO PROTECT OPENINGS AND PENETRATIONS | | THROUGH FLOOR/CEILING AND ROOF/CEILING ASSEMBLIES. | | 713.4 FIRE-RESISTANCE RATING. SHAFT ENCLOSURES SHALL | | HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN 2 HOURS | | WHERE CONNECTING FOUR STORIES OR MORE, AND NOT LESS | | THAN 1 HOUR WHERE CONNECTING LESS THAN FOUR STORIES. | | THE NUMBER OF STORIES CONNECTED BY THE SHAFT ENCLOSURE | | SHALL INCLUDE ANY BASEMENTS BUT NOT ANY MEZZANINES. | | SHAFT ENCLOSURES SHALL HAVE A FIRE RESISTANCE RATING | | NOT LESS THAN THE FLOOR ASSEMBLY PENETRATED, BUT NEED | | NOT EXCEED 2 HOURS. SHAFT ENCLOSURES SHALL MEET THE | | REQUIREMENTS OF SECTION 703.2. | | 713.11 ENCLOSURE AT THE BOTTOM. SHAFTS THAT DO NOT | | EXTEND TO THE BOTTOM OF THE BUILDING OR STRUCTURE SHALL | | COMPLY WITH ONE OF THE FOLLOWING: | | | | 15) SHEETS 0269_FS200 & 0270_FS201 BOTH SHOW KITCHEN | | EXHAUST HOODS REQUIRE A SEPARATE PERMIT. THE SHAFTS | | WOULD BE COVERED UNDER THE BUILDING PERMIT. | | | | 16) SHEETS 0285_S120.7 & 0286_S120.8 THE WATER FEATURE | | ALSO WILL REQUIRE A SEPARATE PERMIT, SHOW THE SAME | | DETAIL SHEETS UNDER THE ARCHITECTURAL, STRUCTURAL, | | ELECTRICAL & PLUMBING DISCIPLES. | | | | 17) SHEET S003 PROVIDES THE WIND DESIGN CRITERIA, | | PLEASE PROVIDE THE MEAN ROOF HEIGHT FOR THE BUILDING | | AND ASSOCIATED PRESSURES FOR ALL ROOF ZONES 1,2,& 3 AND | | WALL ZONES 4 & 5. 2014 FBC-B 1603.1.4 WIND DESIGN DATA. | | (5) . DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF. TABLE | | 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & EXPOSURE. | | PROVIDE THE MEAN ROOF HEIGHT FOR THE BUILDING. | | | | 18) IT SEEMS THE PLANS ARE INCOMPLETE PLEASE PROVIDE | | WHERE THE FOUNDATION SCHEDULE, CONCRETE COLUMN, HOOPS & | | VERTICAL REBAR AND BEAMS ARE LOCATED, I COULD NOT FIND | | THEM IN THE STRUCTURAL SHEETS. | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR | | BUILDINGS. | | 107.3.5.1.1. COMMERCIAL BUILDINGS/ BUILDING: | | FOUNDATION SCHEDULE | | COLUMN SCHEDULE | | BEAM ( CONCRETE/ LINTEL) SCHEDULE | | | | 19) MISSING PRODUCT APPROVALS. 2010/ 2014 FBC-B | | 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.4.1 | | COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY | | AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF | | PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE | | PRODUCT APPROVALS: | | (31)(A) EXTERIOR DOORS. | | (B) WINDOWS | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | LOUVERS, EFIS SYSTEMS, | | (D) ROOFING PRODUCTS AND ASSEMBLIES | | (E) SHUTTERS | | (F) SKYLIGHTS | | | | 20) ADMINISTRATION 107.3.4 DESIGN PROFESSIONAL IN | | RESPONSIBLE CHARGE. THE REGISTERED DESIGN | | PROFESSIONAL IN RESPONSIBLE CHARGE SHALL BE RESPONSIBLE | | FOR REVIEWING AND COORDINATING SUBMITTAL DOCUMENTS | | PREPARED BY OTHERS, INCLUDING PHASED AND DEFERRED | | SUBMITTAL ITEMS, FOR COMPATIBILITY WITH THE DESIGN OF | | THE BUILDING. THOSE PRODUCTS WHICH ARE REGULATED BY DCA | | RULE 9N-3SHALL BE REVIEWED AND APPROVED IN WRITING BY | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL. | | | | 21) ROOFING: FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY | | ALL ROOFING SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES | | FOR ROOF ZONE # 1. REVIEW THE PRODUCT APPROVAL | | LIMITATIONS, IF ENHANCED FASTENING IS ALLOWED FOR ROOF | | ZONES 2 & 3. IF SO RAS 117 CALCULATIONS ARE REQUIRED BY | | EITHER A FLORIDA ARCHITECT OR ENGINEER. | | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED TO | | DETERMINE CODE COMPLIANCE. 2014 FBC-B 1603.1.4 WIND | | DESIGN DATA. | | | | 22) 2014 FBC-M- 301.15 WIND RESISTANCE. MECHANICAL | | EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO | | WIND SHALL BE DESIGNED AND INSTALLED TO RESIST THE WIND | | PRESSURES DETERMINED IN ACCORDANCE WITH THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 23) FBC-B 1013.7 ROOF ACCESS. GUARDS SHALL BE PROVIDED | | WHERE THE ROOF HATCH OPENING IS LOCATED WITHIN 10 FEET | | (3048 MM) OF A ROOF EDGE OR OPEN SIDE OF A WALKING | | SURFACE AND SUCH EDGE OR OPEN SIDE IS LOCATED MORE THAN | | 30 INCHES (762 MM) ABOVE THE FLOOR, ROOF OR GRADE | | BELOW. THE GUARD SHALL BE CONSTRUCTED SO AS TO PREVENT | | THE PASSAGE OF A SPHERE 21 INCHES (533 MM) IN DIAMETER. | | | | 24) FBC-B 1509.6.1 HEIGHT LIMITATIONS. MECHANICAL | | EQUIPMENT SCREENS SHALL NOT EXCEED 18 FEET (5486 MM) IN | | HEIGHT ABOVE THE ROOF DECK, AS MEASURED TO THE HIGHEST | | POINT ON THE MECHANICAL EQUIPMENT SCREEN. | | | | 25) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | THIS REVIEW. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2017-01-06 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2017-01-06 |
Time |
10:46 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2017-01-05 |
Time |
10:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2016-10-12 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-10-12 |
Time |
12:06 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-10-12 |
Time |
12:06 |
Sent To |
|
|
Notes |
2016-10-12 12:07:52 | PROVISO: | | | | ENG HAS AGREED AS PER RESPONSE NARRATIVE TO PROVIDE AT | | A LATER DATE | | | | PROVIDE PHOTOMETRIC FOR ALL INTERIOR AND EXTERIOR | | LIGHTING AREAS, MINIMUM LIGHTINGS LEVELS TO BE | | MAINTAINED PER FBC. | | | | VAL PEREZ | | *6717 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-06-22 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-06-22 |
Time |
10:32 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-06-20 |
Time |
12:08 |
Sent To |
|
|
Notes |
2016-06-22 10:33:15 | APPLICABLE CODES IN EFFECT: | | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70- 2011 NEC | | COMMENTS: | | | | 1. SHEET E100/E200- PROVIDE A BLOCK NOTE INDICATING THE | | REQUIRED SEPARATE PERMITS AND DATA CUT SHEET SUBMITTALS | | FOR ALL SITE LIGHTING AND ASSOCIATED EQUIPMENT. A NOTE | | WILL SUFFICE. | | 2. GENERAL NOTES- PROVIDE A BLOCK NOTE INDICATING THE | | REQUIRED SEPARATE PERMITS AND DATA CUT SHEET SUBMITTALS | | FOR ALL LOW VOLTAGE SYSTEMS TO INCLUDE BUT NOT LIMITED | | TO FIRE ALARM, ACCESS CONTROLS, CCTV, PHONE AND DATA, | | SIGNAGE, WIRELESS SYSTEMS, ETC. A NOTE WILL SUFFICE. | | 3. PLEASE PROVIDE DETAILS OF ALL ELECTRICAL ROOMS | | IMPACTED BY SCOPE OF WORK. FBC 107.3.5 | | 4. PROVIDE A NOTE/SIGN TO INDICATE THE REQUIREMENTS NEC | | 110.24 THE MAX. AVAILABLE FAULT CURRENT SHALL BE | | DURABLY MARKED AND DATED ON ALL ELECTRICAL APPARATUS | | AND NEC 110.16 ARC-FLASH HAZARD WARNING LABELS | | REQUIRED. | | 5. PER FBC EC 405.7.3- SHOW VOLTAGE DROP CALCULATIONS | | FOR FEEDERS AND BRANCH CIRCUITS. | | 6. SHEET E-121.8K- PROVIDE A BLOCK NOTE INDICATING THE | | REQUIRED SEPARATE PERMITS FOR HOOD SUPPRESSION SYSTEMS. | | 7. PROVIDE PHOTOMETRIC FOR ALL INTERIOR AND EXTERIOR | | LIGHTING AREAS, MINIMUM LIGHTINGS LEVELS TO BE | | MAINTAINED PER FBC. | | 8. COMMENTS MAY FOLLOW UPON RE-REVIEW. PLEASE FEEL FREE | | TO CONTACT ME SHOULD YOU HAVE ANY QUESTIONS REGARDING | | THIS PROJECT. | | | | | | VALENTINO PEREZ | | ELECTRICAL PLANS EXAMINER II | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2016-10-21 |
|
|
Cont ID |
|
Sent By |
Mgonzale |
Date |
2016-10-21 |
Time |
|
Rev Time |
1.00 |
Received By |
mgonzale |
Date |
2016-10-21 |
Time |
|
Sent To |
Z |
|
Notes |
2016-10-21 14:51:39 | PROJECT WILL BE REVIEWED THRU ENGINEERING. | | | | | | MANUEL JULIAN GONZALEZ | | ENGINEERING PROJECT COORDINATOR | | PUBLIC WORKS DEPARTMENT | | 401 CLEMATIS STREET, 4TH FLOOR | | WEST PALM BEACH, FL 33401 | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | MAIN PHONE: (561) 822-1200 | | DIRECT: (561) 494-1085 | | FAX: (561) 494-1116 | | EMAIL: [email protected] | | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS | | /FORMS,-PERMITS-APPLICATIONS | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2016-07-20 |
|
|
Cont ID |
|
Sent By |
mgonzale |
Date |
2016-07-20 |
Time |
|
Rev Time |
1.00 |
Received By |
mgonzale |
Date |
2016-07-20 |
Time |
|
Sent To |
Z |
|
Notes |
2016-07-20 14:19:46 | ADDRESS PLANNING'S COMMENTS. | | | | MANUEL JULIAN GONZALEZ | | ENGINEERING PROJECT COORDINATOR | | PUBLIC WORKS DEPARTMENT | | 401 CLEMATIS STREET, 4TH FLOOR | | WEST PALM BEACH, FL 33401 | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | MAIN PHONE: (561) 822-1200 | | DIRECT: (561) 494-1085 | | FAX: (561) 494-1116 | | EMAIL: [email protected] | | WWW.WPB.ORG/ENGINEERING |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2017-03-07 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-03-06 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-03-06 |
Time |
09:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2016-12-22 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-12-22 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-12-22 |
Time |
13:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2016-10-17 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-10-17 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-10-11 |
Time |
16:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2016-06-24 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-06-24 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-06-13 |
Time |
12:07 |
Sent To |
|
|
Notes |
2016-06-20 16:14:05 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | 1) SHEET FS 200 - THERE IS NO INDICATION THAT THE HOOD | | VENTING WILL BE INSTALLED PER NFPA 96 AND UNDER | | SEPARATE SHOP DRAWINGS. | | | | NFPA 101 | | CHAPTER 9 BUILDING SERVICE AND FIRE PROTECTION | | EQUIPMENT | | | | 9.2.3 COMMERCIAL COOKING EQUIPMENT. COMMERCIAL COOKING | | EQUIPMENT SHALL BE IN ACCORDANCE WITH NFPA 96, STANDARD | | FOR VENTILATION CONTROL AND FIRE PROTECTION OF | | COMMERCIAL COOKING OPERATIONS, UNLESS SUCH | | INSTALLATIONS ARE APPROVED EXISTING INSTALLATIONS, | | WHICH SHALL BE PERMITTED TO BE CONTINUED IN SERVICE. | | | | NFPA 96, CHAPTER 4 GENERAL REQUIREMENTS | | 4.1 GENERAL. | | 4.1.1 COOKING EQUIPMENT USED IN PROCESSES PRODUCING | | SMOKE OR GREASE-LADEN VAPORS SHALL BE EQUIPPED WITH AN | | EXHAUST SYSTEM THAT COMPLIES WITH ALL THE EQUIPMENT AND | | PERFORMANCE REQUIREMENTS OF THIS STANDARD. | | | | PLEASE PROVIDE THE APPLICABLE NOTE. | | | | | | 2) SHEET S 300 - THERE APPEARS TO LIGHTWEIGHT TRUSS | | CONSTRUCTION WITHIN AND ON THE STRUCTURE. | | | | PER FLORIDA 69A-60.0081; NOTICE SIGNAGE IS REQUIRED FOR | | STRUCTURES WITH LIGHT-FRAME TRUSS-TYPE CONSTRUCTION. | | ANY COMMERCIAL, INDUSTRIAL, OR ANY MULTIUNIT | | RESIDENTIAL STRUCTURE OF THREE UNITS OR MORE WHICH USES | | HORIZONTAL OR VERTICAL LIGHT-FRAME TRUSS-TYPE | | CONSTRUCTION IN ANY PORTION SHALL BE MARKED WITH A | | MALTESE CROSS SIGN MEASURING 8 INCHES HORIZONTALLY AND | | 8 INCHES VERTICALLY, OF A BRIGHT RED REFLECTIVE COLOR. | | THE APPROVED SYMBOL SHALL BE PLACED WITHIN 24 INCHES TO | | THE LEFT OF THE MAIN ENTRY DOOR. | | 1. STRUCTURES WITH LIGHT-FRAME TRUSS ROOFS SHALL BE | | MARKED WITH THE LETTER "R". | | 2. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR SYSTEMS | | SHALL BE MARKED WITH THE LETTER "F". | | 3. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR AND ROOF | | SYSTEMS SHALL BE MARKED WITH THE LETTERS "R/F". | | | | | | 3) SHEET LS 001 & FP 100 - A STANDPIPE SYSTME IS | | INDICATED ON LS 100; HOWEVER, THERE IS NO INDICATIONS | | OF STANDPIPE(S) ON FP 100. | | | | PLEASE PROVIDE INDICATIONS AND LOCATIONS OF STANDPIPE | | PROTECTION. | | | | | | 4) SHEET E 001 - THERE IS NO INDICATION THAT THE FIRE | | ALARM WILL BE INSTALLED PER NFPA 72 AND UNDER SEPARATE | | SHOP DRAWINGS. | | | | NFPA 101, CHAPTER 9 BUILDING SERVICE AND FIRE | | PROTECTION EQUIPMENT | | 9.6.1.3 A FIRE ALARM SYSTEM REQUIRED FOR LIFE SAFETY | | SHALL BE INSTALLED, TESTED, AND MAINTAINED IN | | ACCORDANCE WITH THE APPLICABLE REQUIREMENTS OF N | | FPA 70, NATIONAL ELECTRICAL CODE, AND NFPA | | 72, NATIONAL FIRE ALARM AND SIGNALING CODE, UNLESS IT | | IS AN APPROVED EXISTING INSTALLATION, WHICH SHALL BE | | PERMITTED TO BE CONTINUED IN USE. | | | | PLEASE PROVIDE A NOTE INDICATING THAT THE FIRE ALARM | | SHALL BE INSTALLED PER NFPA 72 AND UNDER SEPARATE SHOP | | DRAWINGS.. | | | | | | 5) SHEET LS 001 - THERE IS NO INDICATIONS THAT THE FIRE | | ALARM WILL BE SUBMITTED AND INSTALLED UNDER SEPARATE | | SHOP DRAWINGS. | | | | PLEASE PROVIDE A NOTE. | | | | | | 6) SHEET LS 001 - THERE IS INDICATION UNDER THE TILTE | | VERTICAL OPENINGS FOR THE INSTALLTION OF A DRAFT | | CURTAIN AND CLOSELY SPACED SPRINKLERS. SHEET FP 100 AND | | OTHER FP SHEETS DO NOT INCLUDE INDICATIONS OR DESIGN. | | | | PLEASE PROVIDE DESIGN INDICATORS FOR DRAFT CURTAINS AND | | CLOSELY SPACED SPRINKLERS IN THE APPLICABLE SPACES PER | | THE ENGINEER OF RECORD. | | | | | | 7) SHEET A 806 - WITHIN THE DOOR SCHEDULE UNDER THE | | HDWR SET HEADING THERE IS REFERENCE TO "E" NUMBERS AND | | OTHER NUMBERS. THOSE INDICATORS COULD NOT BE READILY | | IDENTIFIED ON THIS SHEET OR ANOTHER SHEET TO CONFIRM | | PROPER HARDWARE. | | | | PLEASE CLARIFY OR IDENTFY THE CORRESPONDING SHEET. | | | | 8) SHEET LS 101 & A 806 - DOOR 116 IS INDCIATED WITHIN | | A SMOKE BARRIER WALL; HOWEVER, THE DOOR SCHEDULE DOES | | NOT INDICATE IT WITH ANY FIRE RATING. | | | | PLEASE CORRECT OR VERIFY. | | | | 9) SHEET LS 101 & A 806 - DOOR 118 D IS INDICATED | | WITHINA SMOKE BARRIER WALL; HOWEVER, THE DOOR SCHEDULE | | DOES NOT INDICATE IT WITH ANY FIRE RATING. | | | | 10) SHEET LS 101 & A 806 - DOOR 123 IS INDICATED WITHIN | | A 2 HR FIRE RATED WALL; HOWEVER, THE DOOR SCHEDULE | | INDICATES AS A SMOKE BARRIER DOOR. | | | | PLEASE COORECT TO 90 MIN. DOOR OR VERIFY. | | | | 11) SHEET LS 101, A 121 & A 806 - THE FLOOR LAYOUT | | AROUND DOOR 105 IS SLIGHTLY DIFFERENT; HOWEVER, DOOR | | 105 IS WITHIN A 2 HR FIRE RATED WALL AND THE DOOR | | SCHEDULE DOES NOT INDICATE ANY FIRE RATING. | | | | PLEASE CORRECT TO 90 MIN DOOR OR VERIFY. | | | | 12) SHEET LS 102 & A 806 - DOOR 226E IS INDICATED | | WITHIN A SMOKE BARRIER WALL; HOWEVER, THE DOOR SCHEDULE | | DOES NOT INDICATE IT WITH ANY FIRE RATING. | | | | PLEASE COORECT TO 90 MIN. DOOR OR VERIFY. | | | | 13 ) SHEET LS 102 & A 806 - DOOR 225A IS INDICATED | | WITHIN A SMOKE BARRIER WALL; HOWEVER, THE DOOR SCHEDULE | | DOES NOT INDICATE IT WITH ANY FIRE RATING. | | | | PLEASE COORECT TO 90 MIN. DOOR OR VERIFY. | | | | 14) SHEET LS 101M & A 806 - DOOR 101 MA IS INDICATED | | WITHIN A 2 HR FIRE RATED WALL; HOWEVER, THE DOOR | | SCHEDULE INDICATES NO RATING. | | | | PLEASE COORECT TO 90 MIN. DOOR OR VERIFY. | | | | 15) SHEET LS 101 & A 806 - DOOR 124 IS INDICATED WITHIN | | A 2 HR FIRE RATED WALL; HOWEVER, THE DOOR SCHEDULE | | INDICATES NO RATING. | | | | PLEASE COORECT TO 90 MIN. DOOR OR VERIFY. | | | | 16) SHEET LS 101 & A 806 - THE DOOR CONNECTING VESTIBLE | | 124 AND THE STAIRWELL DOES NOT APPEAR TO BE INDICATED | | WITH A DOOR NUMBER AND IS NOT ON THE DOOR SCHEDULE. | | | | PLEASE COORECT OR VERIFY. | | | | 17) SHEET A 806 - THERE IS INDICATIONS WITHIN THE DOOR | | SCHEDULE OF HARDWARE SET ID NUMBERS. I AM NOT ABLE TO | | READLITY LOCATE THE SHEET THAT IDENTIFIES THE | | CORRESPONDING HARDWARE SETS FOR VERIFICATION PURPOSES. | | | | PLEASE CORRECT OF VERIFY. | | | | 18) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | | | | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
P |
Date |
2017-03-06 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-03-06 |
Time |
16:19 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-03-06 |
Time |
16:19 |
Sent To |
|
|
Notes |
2017-03-06 16:19:47 | PROVISO 2ND REQUEST | | PLUMBING | | 1. PROVIDE A CLEAR AND CONCISE ISOMETRIC DRAWING FOR | | THE STORM DRAIN SHOWING ALL SIZES SLOPE OF PIPE, SQ FT | | AND LEVEL. THE ONE IN THE PLAN SET IS NOT CLEAR AND | | DOES NOT SHOW ALL THE REQUIRED INFORMATION. MUST BE | | APPROVED BY BUILDING DEPARTMENT PRIOR TO FIST ROUGH | | INSPECTION. | | GAS | | 1. PROVIDE COMBUSTION AIR CALCULATIONS FOR GAS | | APPLIANCES IN THE KITCHEN. MUST BE APPROVED BY BUILDING | | DEPARTMENT PRIOR TO FIST ROUGH INSPECTION. | | 2. PROVIDE MANUFACTURE SPECIFICATIONS AND INSTALLATION | | GUIDE FOR GAS APPLIANCES. MUST BE APPROVED BY BUILDING | | DEPARTMENT PRIOR TO FIST ROUGH INSPECTION. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | | | | | | | | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2017-01-20 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-01-20 |
Time |
09:47 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-01-20 |
Time |
09:47 |
Sent To |
|
|
Notes |
2017-01-20 09:47:56 | PROVISO | | PLUMBING | | 1. PROVIDE A CLEAR AND CONCISE ISOMETRIC DRAWING FOR | | THE STORM DRAIN SHOWING ALL SIZES SLOPE OF PIPE, SQ FT | | AND LEVEL. THE ONE IN THE PLAN SET IS NOT CLEAR AND | | DOES NOT SHOW ALL THE REQUIRED INFORMATION. MUST BE | | APPROVED BY BUILDING DEPARTMENT PRIOR TO FIST ROUGH | | INSPECTION. | | GAS | | 1. PROVIDE COMBUSTION AIR CALCULATIONS FOR GAS | | APPLIANCES IN THE KITCHEN. MUST BE APPROVED BY BUILDING | | DEPARTMENT PRIOR TO FIST ROUGH INSPECTION. | | 2. PROVIDE MANUFACTURE SPECIFICATIONS AND INSTALLATION | | GUIDE FOR GAS APPLIANCES. MUST BE APPROVED BY BUILDING | | DEPARTMENT PRIOR TO FIST ROUGH INSPECTION. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | | | | | | | | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2016-10-28 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-10-28 |
Time |
11:50 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-10-28 |
Time |
11:50 |
Sent To |
|
|
Notes |
2016-10-28 11:54:34 | 1ST REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | GAS COMMENTS: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL | | CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS ENCLUDE | | EXISTING PER FBC-2014 FUEL GAS, SECS. 402.4.1, 402.4.2. | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL | | PIPE SIZES, AND THE EHD NUMBER OF CORRUGATED STAINLESS | | STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. WPB | | AMENDMENTS TO FBC SEC. 107.2.1. | | | | 3. TYPE OF GAS, (LP OR NATURAL). | | | | 4. BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD ON | | THE SYSTEM. ENCLUDE ANY EXISTING REFER TO THE FBC-2014 | | FUEL GAS SECS. 401.8 THRU 402.6.1 AND TABLES 402.4(1) | | THRU 402.4(37). | | | | 5. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, | | (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING | | AND/OR SYSTEM PER THE FBC-2014 FUEL GAS APPENDIX A ? | | USE OF CAPACITY SECTION A.3.1(4) & 2014 FUEL GAS CODE | | SEC. 402.4.1. | | | | 6. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | FBC-2014 FUEL GAS CODE SEC. 304. | | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) PER FBC-2014 | | FUEL GAS SEC. 402.2. IF NATURAL GAS SPECIFY .5 PSI OR 2 | | PSI. | | | | 8. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE | | SEC. 502 THRU 505. | | | | 9. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2017-03-13 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2017-03-13 |
Time |
15:58 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2017-02-17 |
Time |
09:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-01-23 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-01-23 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-12-16 |
Time |
09:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-12-08 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-12-08 |
Time |
08:54 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2016-10-05 |
Time |
09:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-07-22 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2016-07-22 |
Time |
09:02 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2016-06-03 |
Time |
08:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
N |
Date |
2017-01-09 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-01-09 |
Time |
16:22 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-01-09 |
Time |
16:22 |
Sent To |
|
|
Notes |
2017-01-09 16:23:09 | P. B. C. IMPACT FEES WERE PAID UNDER STRUCTURAL PERMIT | | 16080215. | | RECEIPT NUMBER 2016-1018-70 | | MU RECEIPT: 2016-024353-0000 | | FEES: $3,805.74 | | J. WITMER PX | 2016-11-04 11:09:12 | IMPACT FEES GIVEN TO JWITMER |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2016-10-28 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-10-28 |
Time |
16:46 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-10-28 |
Time |
16:46 |
Sent To |
|
|
Notes |
2016-10-28 16:46:26 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2016-06-28 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-06-28 |
Time |
14:47 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-06-28 |
Time |
14:47 |
Sent To |
|
|
Notes |
2016-06-28 14:58:12 | IMPACT FEES | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2017-03-09 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-03-09 |
Time |
15:56 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-02-24 |
Time |
07:33 |
Sent To |
|
|
Notes |
2017-03-09 16:14:06 | MECHANICAL PROVISOS. | | NORTON MUSEUM OF ART | | PERMIT #16050912 | | 3/9/2017 | | | | 1) THE MECHANICAL PLANS HAVE BEEN APPROVED | | CONDITIONALLY. A REVISION TO THE PLANS IS REQUIRED TO | | CORRECT THE DEFICIENCIES LISTED BELOW. | | | | A) PROVIDE DUCT SMOKE DETECTORS IN THE RETURN SYSTEMS | | OF THE AHU'S. | | | | B) PROVIDE FIRE DAMPERS FOR ALL DUCTS PENETRATING THE | | FIRE-RATED WALL OF MECHANICAL ROOM 302. | | | | C) A NEW CHILLER (CH-1) IS BEING INSTALLED IN THE | | EXISTING MECHANICAL ROOM. ADDITIONAL VENTILATION FOR | | NORMAL AND EMERGENCY VENTILATION MAY BE REQUIRED. REFER | | TO SECTIONS 1105.6- 1105.6.3.2 FBC-14 MECHANICAL AND | | PROVIDE EXHAUST VENTILATION CALCULATIONS FOR BOTH | | NORMAL AND EMERGENCY CONDITIONS AS REQUIRED BY SECTIONS | | 1105.6.3.1 AND 1105.6.3.2. SHOW LOCATIONS OF ALL | | COMPONENTS OF THE VENTILATION SYSTEM INCLUDING EXHAUST | | FANS AND AIR INTAKES. INCLUDE EQUIPMENT SCHEDULES FOR | | ALL EXISTING FANS OR NEW FANS (EXHAUST OR INTAKE) | | INDICATING THEIR CAPACITIES, AND THE DIMENSIONS OF ALL | | AIR INTAKE OPENINGS. PLEASE NOTE THE NEW CH-3 USES A | | DIFFERENT REFRIGERANT THAN THE EXISTING CH-1 AND CH-2, | | THEREFORE THE EXISTING LEAK DETECTOR MAY NOT BE | | COMPATIBLE. | | SUBMIT SPECIFICATIONS FOR THE LEAK DETECTOR. | | | | D) AHU HEATING COIL: CORRECT OR CLARIFY THE CONFLICTS | | BETWEEN THE AC CALCULATIONS FOR THE HEATING COIL | | SELECTION VERSUS THE HEATING CAPACITIES SHOWN IN THE | | EQUIPMENT SCHEDULES: AHU'S 3, 14, 18, 19, 20, & 22. | | | | 2) DEFERRED SUBMITTALS: AS REQUESTED BY THE CONTRACTOR | | PLEASE REVIEW THE FOLLOWING LIST OF DEFERRED | | SUBMITTALS. PLEASE NOTE:) DEFERRED SUBMITTALS SECTION | | 107.3.4.2 WPB AMENDMENTS TO THE FBC. FOR THE PURPOSES | | OF THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS | | THOSE PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT | | THE TIME OF THE APPLICATION AND THAT ARE TO BE | | SUBMITTED TO THE BUILDING OFFICIAL WITHIN A SPECIFIED | | PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE | | PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | FOR REVIEW BY THE BUILDING OFFICIAL. | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | OFFICIAL. | | | | A) STRUCTURAL ENGINEERING FOR INSTALLATION OF THE | | COOLING TOWERS INCLUDING THE SUPPORT BASE, ACCESS | | STAIRS, WALKWAYS AND PLATFORM. | | | | B) MECHANICAL AND ELECTRICAL POWER AND LIGHTING SYSTEMS | | COMMISSIONING: PRELIMINARY AND FINAL REPORTS. | | | | C) FLORIDA PRODUCT APPROVALS AND/OR MIAMI-DADE NOA'S | | FOR LOUVERS PROTECTING OUTSIDE AIR AND EXHAUST OUTLET | | OPENINGS. PLEASE NOTE:) PRODUCT APPROVALS- THOSE | | PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03 | | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL. | | | | D) MANUFACTURER'S SPECIFICATIONS FOR THE GLOBAL PLASMA | | SOLUTIONS IAQ EQUIPMENT AND DEVICES. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2017-01-10 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-01-10 |
Time |
17:39 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-01-10 |
Time |
14:18 |
Sent To |
|
|
Notes |
2017-01-10 17:47:30 | 3RD REVIEW FBC-2014 MECHANICAL | | PERMIT #16050912 | | NORTON MUSUEM | | 1/10/17 | | | | 1) 3RD REQUEST FOR AC COOLING AND HEATING CALCULATIONS. | | | | 2) THE REVISED ENERGYGAUGE COMPLIANCE FORM WAS | | SUBMITTED WITHOUT THE OWNER/AGENT'S SIGNATURE. | | | | 3) 3RD REQUEST FOR COMPLETE VENTILATION CALCULATIONS. | | THE CALCULATIONS ON M607 ARE FOR THE ROOMS AND SPACES | | UTILIZING THE IAQ PROCEDURE - SYSTEMS 3, 18, 19,20,21,& | | 22, HOWEVER MINIMUM VENTILATION CALCULATIONS ARE | | REQUIRED FOR ALL OF THE OTHER ROOMS AND SPACES I.E. THE | | FIRST FLOOR GALLERIES AND DINING AREAS ON THE SOUTH | | END- SYSTEMS 14 & 15. PLEASE NOTE THAT DEMAND | | CONTROLLED VENTILATION MAY BE REQUIRED- SEE SECTION | | C403.2.5.1 FBC-14 ENERGY CONSERVATION. | | | | 4) 3RD REQUEST FOR EXHAUST VENTILATION CALCULATIONS FOR | | THE CHILLER ROOM , AND AN EQUIPMENT SCHEDULE FOR EF-9. | | | | 5) 3RD REQUEST FOR DUCT SMOKE DETECTORS TO BE SHOWN IN | | THE RETURN AIR SYSTEMS OF THE AHU'S. | | | | 6) 3RD REQUEST TO SHOW THE MISSING SMOKE AND FIRE | | DAMPERS: | | REFER TO SECTION 607.5.4.AND PROVIDE SMOKE DAMPERS FOR | | ALL DUCTS LISTED BELOW THAT PENETRATE SMOKE BARRIERS, | | UNLESS MEETING ONE OF THE THREE EXCEPTIONS LISTED UNDER | | THE SECTION. | | M121.5- 12X10 DUCT AT SMITH GALLERY 131/RESTROOM WALL. | | M121.8- 38X14 & 42X14 DUCTS AT LAUDER RESTAURANT | | 120/LOBBY 118/CORRIDOR 113 WALLS. | | M122.8- 12X12 AT CONFERENCE 223/MCGRAW 225. | | 30X12 AT MCGRAW 225/VESTIBULE 226. | | 14X10 AT MARDEN 226/MCGRAW 225. | | M123.7- ALL DUCTS TRAVERSING THROUGH THE MARDEN GALLERY | | 226/ CLASSROOM 221/ THE ADMISSIONS/GRAND HALL/& OFFICES | | 209 & 210. | | M123.8- DUCTS AT CORRIDOR 301/MEP & GROSS GALLERY 304. | | M123.8:FSD'S FOR DUCTS PENETRATING THE SHAFT AT | | CORRIDOR 301. | | PROVIDE KEY NOTES AT ALL FD, FSD, AND SD DAMPER | | LOCATIONS. | | . | | 7) INDICATE HOW ACCESS WILL BE PROVIDED TO THE FIRE | | DAMPERS LOCATED AT THE FLOOR/CEILING ASSEMBLY ABOVE THE | | STILLER AUDITORIUM. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | CCOLE | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2016-10-26 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-10-26 |
Time |
08:22 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-10-24 |
Time |
17:41 |
Sent To |
|
|
Notes |
2016-10-26 08:23:33 | 2ND REVIEW FBC-2014 MECHANICAL | | PERMIT #16050912 | | NORTON MUSEUM OF ART | | 10/25/16 | | | | THE SECOND REVIEW OF THE RESUBMITTED PLANS AND | | DOCUMENTS INDICATE THAT MANY OF THE 1ST REVIEW COMMENTS | | STILL EXIST EITHER ENTIRELY OR PARTIALLY. THOSE | | COMMENTS AND THE DESIGN PROFESSIONAL'S NARRATIVE | | RESPONSES WILL BE REFERENCED IN THIS FOLLOW-UP REVIEW | | | | 1) COMMENT #1 FROM THE 1ST REVIEW: AS REQUESTED BY THE | | ENGINEER IN THE NARRATIVE, THE COMMISSIONING OF THE | | BUILDING MECHANICAL AND ELECTRICAL POWER AND LIGHTING | | SYSTEMS IS ACCEPTABLE AS A DEFERRED SUBMITTAL, HOWEVER | | AN OUTLINE OF THE PROCEDURES MUST BE PLACED ON THE | | MECHANICAL AND ELECTRICAL PLANS. | | | | 2) COMMENT #2, 1ST REVIEW: THE REQUESTED AC COOLING AND | | HEATING CALCULATIONS WERE NOT SUBMITTED- PLEASE | | PROVIDE. | | | | 3) COMMENT #3: THE ENERGYGAUGE COMPLIANCE SUBMITTAL | | MUST BE SIGNED BY THE OWNER/AGENT. | | | | 4) COMMENT #4: PLEASE REFER TO SECTION 6.3.6 ASHRAE | | 62.1- 2010 AND SUBMIT DOCUMENTATION TO CLARIFY THE IAQ | | PROCEDURE. | | | | 6.3.6 DOCUMENTATION. WHEN THE IAQ PROCEDURE IS USED, | | THE FOLLOWING INFORMATION SHALL BE INCLUDED IN THE | | DESIGN DOCUMENTATION: | | THE CONTAMINANTS OF CONCERN CONSIDERED IN THE | | DESIGN PROCESS, THE SOURCES AND EMISSION RATES OF THE | | CONTAMINANTS | | OF CONCERN, THE CONCENTRATION LIMITS AND EXPOSURE | | PERIODS | | AND THE REFERENCES FOR THESE LIMITS, AND THE ANALYTICAL | | APPROACH USED TO DETERMINE VENTILATION RATES AND AIR | | CLEANING | | REQUIREMENTS. THE CONTAMINANT MONITORING AND OCCUPANT | | AND/ | | OR VISITOR EVALUATION PLANS SHALL ALSO BE INCLUDED IN | | THE DOCUMENTATION. | | | | 5) COMMENTS #5 & 6: DEFERRED SUBMITTALS FOR THE O/A | | LOUVERS ARE ACCEPTABLE PER THE NARRATIVE REQUEST, | | HOWEVER THE LOCATIONS AND CLEARANCES FOR THE AIR | | INTAKES MOST BE SHOWN ON THE PLANS. | | | | 6) COMMENT #7: THE NARRATIVE REFERENCES SHEET M-604 IN | | RESPONSE TO THE COMMENT, HOWEVER THAT PLAN SHEET HAS | | NOT BEEN UPLOADED FOR REVIEW. | | | | 7) COMMENT #8: THE REQUESTED EXHAUST VENTILATION | | CALCULATIONS FOR THE CHILLER ROOM AND FAN SCHEDULE WERE | | NOT PROVIDED- SEE SECTIONS 1105.6.3.1 AND 1105.6.3.2 | | AND INDICATE COMPLIANCE. | | | | 8) COMMENT #10: THE NARRATIVE RESPONSE SUBMITTED TO | | THIS COMMENT STATES THAT THE ANCHORAGE OF THE COOLING | | TOWERS WILL BE ENGINEERED AND INSTALLED BY THE | | CONTRACTOR. PLEASE NOTE THAT THE STRUCTURAL PLANS AND | | DETAILS FOR INSTALLATION OF THE COOLING TOWERS | | INCLUDING THE SUPPORT BASES AND ATTACHMENTS SHALL BE | | DESIGNED BY A FL. LICENSED ENGINEER IN ACCORDANCE WITH | | FLORIDA STATUTE 471. PLEASE PROVIDE THE REQUESTED | | ENGINEERING AND SUBMITTAL DOCUMENTS. | | | | 9) COMMENT #12: PLEASE CORRECT THE ENERGY SUBMITTAL | | WHICH INDICATES 1 CHILLER INSTEAD OF THE 3 BEING | | INSTALLED, AND SUBMIT MANUFACTURER'S SPECIFICATIONS AS | | PREVIOUSLY REQUESTED. | | | | 10) PLEASE REFER BACK TO COMMENT #14 FROM THE 1ST | | REVIEW AND ADD THE REQUESTED KEY NOTES TO IDENTIFY DUCT | | DROPS AND RISERS AND THEIR RESPECTIVE AHU'S. | | | | A) SEE SECTIONS 606.2.1 AND 606.2.3 AND SHOW THE | | LOCATIONS OF ALL REQUIRED DUCT SMOKE DETECTORS. | | | | B) REFER TO SECTION 607.5.4. AND PROVIDE SMOKE DAMPERS | | FOR ALL DUCTS LISTED BELOW THAT PENETRATE SMOKE | | BARRIERS, UNLESS MEETING ONE OF THE THREE EXCEPTIONS | | LISTED UNDER THE SECTION. | | M121.5- 12X10 DUCT AT SMITH GALLERY 131/RESTROOM WALL. | | M121.8- 38X14 & 42X14 DUCTS AT LAUDER RESTAURANT | | 120/LOBBY 118/CORRIDOR 113 WALLS. | | M122.8- 12X12 AT CONFERENCE 223/MCGRAW 225. | | 30X12 AT MCGRAW 225/VESTIBULE 226. | | 14X10 AT MARDEN 226/MCGRAW 225. | | M123.7- ALL DUCTS TRAVERSING THROUGH THE MARDEN GALLERY | | 226/ CLASSROOM 221/ THE ADMISSIONS/GRAND HALL/& OFFICES | | 209 & 210. | | M123.8- DUCTS AT CORRIDOR 301/MEP & GROSS GALLERY 304. | | PROVIDE KEY NOTES AT ALL FD, FSD, AND SD DAMPER | | LOCATIONS. | | | | C) M122.5B: SHOW HORIZONTAL DAMPERS AT DUCT | | PENETRATIONS OF THE FLOOR/CEILING ASSEMBLY IN THE | | MECHANICAL EQUIPMENT ROOM. THIS COMMENT SHALL APPLY TO | | ALL PLAN SHEETS SHOWING DUCTS PENETRATING HORIZONTAL | | MEMBRANES | | | | D) AS PREVIOUSLY REQUESTED PLEASE IDENTIFY ALL ROOMS ON | | THE MECHANICAL PLANS. | | | | 12) COMMENT #16: PROVIDE A CONDENSATE DISPOSAL RISER | | AND LAYOUT PLAN SHOWING ALL PIPING RUNS, PIPE TYPES AND | | SIZES, AND DISCHARGE LOCATIONS. | | | | 13) PLEASE PROVIDE A MECHANICAL SYMBOL AND LEGEND PLAN | | SHEET. | | | | 14) REFER TO SECTION 107.3.4.2 WPB AMENDMENTS OF THE | | FBC AND PROVIDE ON THE PLAN OR IN DOCUMENT FORM A LIST | | OF ALL MECHANICAL EQUIPMENT AND COMPONENTS THAT ARE | | REQUESTED TO BE DEFERRED SUBMITTALS. | | | | A) DEFERRED SUBMITTAL: 107.3.4.2 DEFERRED SUBMITTALS. | | FOR THE PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS | | ARE DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE | | NOT SUBMITTED AT THE TIME OF THE APPLICATION AND THAT | | ARE TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A | | SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL | | HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION | | DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | OFFICIAL. | | B) DEFERRED SUBMITTAL. 2010 FBC 107.3.4.1 PRODUCT | | APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED BY THE | | DCA RULE 9N-03 SHALL BE REVIEWED AND APPROVED IN | | WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-06-22 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-06-22 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-06-15 |
Time |
17:33 |
Sent To |
|
|
Notes |
2016-06-22 15:48:38 | NORTON MUSUEM | | PERMIT #16050512 | | 1ST REVIEW MECHANICAL | | 6/16/16 | | | | PLEASE REFER TO SECTION 107.3.5.1 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE- MINIMUM PLAN | | REVIEW CRITERIA FOR COMMERCIAL BUILDINGS. THE UPLOADED | | PLANS AND DOCUMENTS ARE NOT MEETING THE MINIMUM | | REQUIREMENTS, AND MORE DETAILS AND SUBMITTALS WILL BE | | REQUIRED FOR A THOROUGH REVIEW OF THE PROJECT. PLEASE | | REVIEW THE COMMENT LIST BELOW AND PROVIDE A RESPONSE | | NARRATIVE FROM THE DESIGN PROFESSIONAL CORRESPONDING TO | | THE RESUBMITTED AND CORRECTED PLANS AND DOCUMENTS. | | | | 1) REFER TO SECTION C408.2 FBC-14 ENERGY CONSERVATION | | AND PROVIDE A COMMISSIONING PLAN AS OUTLINED IN SECTION | | C408.2.1. | | | | 2) REFER TO SECTION C403.2.1 AND PROVIDE AC COOLING AND | | HEATING CALCULATIONS FOR ALL NEW SYSTEMS SHOWN IN THE | | PLANS AND THE SCHEDULES. | | | | 3) REFER TO SECTION C103.1.1.1.2: THE SUBMITTED ENERGY | | CALCULATIONS MUST BE SIGNED BY ALL OF THE DESIGN | | PROFESSIONALS INVOLVED WITH THE PROJECT. | | | | 4) PROVIDE MINIMUM VENTILATION CALCULATIONS IN | | ACCORDANCE WITH TABLE 403.3 FBC-14 MECHANICAL. PROVIDE | | ON THE PLAN A SCHEDULE INDICATING BOTH THE REQUIRED AND | | PROVIDED CFM'S OF OUTDOOR AIR FOR ALL ROOMS AND SPACES. | | | | 5) SHOW THE LOCATIONS OF ALL OUTDOOR AIR INTAKES- | | GRAVITY OR MECHANICAL- WITH REQUIRED CLEARANCE | | DISTANCES AS REQUIRED BY SECTION 401.4. | | | | 6) REFER TO SECTION 401.5 FOR ALL AIR INTAKES OPENINGS | | TO BE PROTECTED BY LOUVERS. PRODUCT APPROVALS AND/OR | | MIAMI-DADE NOA'S MUST BE LISTED ON THE PLANS AND | | DOCUMENTS MUST BE SUBMITTED WITH THE DESIGN | | PROFESSIONAL'S APPROVAL SIGNATURE. THIS INCLUDES THE 45 | | SF AIR INTAKE SHOWN ON M123.8. | | | | 7) PROVIDE EXHAUST VENTILATION CALCULATIONS THAT | | CORRELATE WITH ALL FANS SHOWN IN THE SCHEDULE AND ALL | | OTHER ROOMS AND SPACES REQUIRING EXHAUST PER TABLE | | 403.3 FBC-14 MECHANICAL, AND TABLE 6-4 ASHRAE | | 62.1-2010. SEE COMMENT #8 BELOW FOR THE MECHANICAL ROOM | | VENTILATION REQUIREMENTS. A) REFER TO SECTION 501.3.1 | | AND INDICATE ALL REQUIRED CLEARANCES FOR THE EXHAUST | | OUTLET TERMINATIONS. B) PROVIDE AIR BALANCE | | CALCULATIONS THAT CORRELATE WITH THE REQUIRED MINIMUM | | VENTILATION CALCS- SEE COMMENT #4 ABOVE. ADVISORY: | | SEPARATE PERMITS, PLANS, AND CALCULATIONS FOR THE | | KITCHEN EXHAUST HOOD AND FIRE SUPPRESSION SYSTEMS ARE | | REQUIRED, HOWEVER THE EXHAUST CFM'S MUST BE INCLUDED IN | | THE AIR BALANCE CALCULATIONS. | | | | 8) SHEET M121.7: A NEW CHILLER (CH-1) IS BEING | | INSTALLED IN THE EXISTING MECHANICAL ROOM. ADDITIONAL | | VENTILATION FOR NORMAL AND EMERGENCY VENTILATION MAY BE | | REQUIRED. REFER TO SECTIONS 1105.6- 1105.6.3.2 AND | | PROVIDE EXHAUST VENTILATION CALCULATIONS FOR BOTH | | NORMAL AND EMERGENCY CONDITIONS AS REQUIRED BY SECTIONS | | 1105.6.3.1 AND 1105.6.3.2. SHOW LOCATIONS OF ALL | | COMPONENTS OF THE VENTILATION SYSTEM INCLUDING EXHAUST | | FANS AND AIR INTAKES. INCLUDE EQUIPMENT SCHEDULES FOR | | ALL EXISTING FANS OR NEW FANS (EXHAUST OR INTAKE) | | INDICATING THEIR CAPACITIES, AND THE DIMENSIONS OF ALL | | AIR INTAKE OPENINGS. PLEASE NOTE: A) EF-9 SHOWN IN THE | | DRAWING IS NOT INCLUDED IN THE SCHEDULE. IS THIS AN | | EXISTING FAN? B) THE NEW CH-3 USES A DIFFERENT | | REFRIGERANT THAN THE EXISTING CH-1 AND CH-2, THEREFORE | | THE EXISTING LEAK DETECTOR MAY NOT BE COMPATIBLE. C) | | WHERE ARE THE NOTES OR DETAILS THAT CORRESPOND WITH THE | | M91, 92, 93, & 94 TAGS SHOWN AT THE MECHANICAL ROOM. | | THE M TAG IS USED IN OTHER PLAN LOCATIONS BUT I HAVE | | NOT LOCATED ANY CORRESPONDING NOTES OR DETAILS. | | | | 9) PROVIDE AN ENLARGED DRAWING OF THE MECHANICAL ROOM | | SHOWING ALL EQUIPMENT, PIPING LAYOUTS, WORKING | | CLEARANCES, EQUIPMENT ANCHORING, AND RELIEF PIPINGS AND | | VENTS. | | | | 10) SHEET M122.7: PROVIDE ENLARGED DRAWINGS OF THE NEW | | COOLING TOWERS INCLUDING SITE SPECIFIC WIND LOAD | | ENGINEERING FOR ANCHORING THE SUPPORT BASE TO THE ROOF | | STRUCTURE, AND THE TOWERS TO THE SUPPORT STEEL. PROVIDE | | MANUFACTURER'S SPECIFICATIONS FOR THE COOLING TOWERS | | APPROVED WITH SIGNATURES BY THE EOR. | | | | 11) M601: REFER TO TABLES C403.2.3(7) AND C40.2.3(8) | | FBC-14 ENERGY CONSERVATION AND PROVIDE IN THE EQUIPMENT | | SCHEDULES THE EFFICIENCY AND PERFORMANCE RATINGS FOR | | THE CHILLER AND THE COOLING TOWERS. SUBMIT | | MANUFACTURER'S SPECIFICATIONS FOR THE CHILLER, TOWERS, | | AND PUMPS WITH APPROVAL SIGNATURES BY THE EOR. | | | | 12) M105: REFER TO SECTION 301.15 FBC-14 MECHANICAL AND | | SECTION 1609 FBC-14 BUILDING AND SHOW THE LOCATIONS OF | | ALL ROOFTOP MECHANICAL EQUIPMENT, AND PROVIDE WIND LOAD | | ENGINEERING FOR TIE DOWN OF ALL APPLIANCES, EQUIPMENT, | | CURBS AND STANDS TO THE ROOF STRUCTURE. A) SHOW THE | | REQUIRED CLEARANCE DISTANCES FOR ALL EXHAUST OUTLETS TO | | AIR INTAKES. B) SHOW THE CLEARANCE DISTANCS FROM THE | | SERVICEABLE EQUIPMENT TO THE ROOF EDGES- SECTION | | 304.11. | | | | 13) M601: AHU'S 23, 30, 31, 32, 33, & 34 LISTED AS NEW | | IN THE SCHEDULE ARE NOT SHOWN IN THE ENERGY | | CALCULATIONS. PLEASE DARKEN THE PRINTED NOTES UNDER THE | | AHU SCHEDULE- THEY ARE TOO FAINT TO READ. | | | | 14) SHEETS M121.7- M123.8B, 1ST, 2ND, & 3RD FLOOR | | MECHANICAL PLANS: MANY OF THE SAME DEFICIENCIES AND | | OMISSIONS EXIST ON ALL OF THESE PLAN SHEETS. IT MAY BE | | HELPFUL TO ADD KEY NOTES TO ALL THESE SHEETS AND LEGEND | | SYMBOLS TO CLARIFY THE SCOPE OF WORK AND EXPEDITE THE | | REVIEW, I.E. IT IS DIFFICULT TO TELL WHICH AC SYSTEMS | | THE DUCT DROPS ARE CONNECTED TO. AN AC LABEL AT THESE | | LOCATIONS WOULD BE VERY HELPFUL A) DUCT SMOKE DETECTORS | | IN THE RETURN AIR SYSTEMS NOT SHOWN- SEE SECTIONS | | 606.2.1 AND 606.2.3. B) FIRE AND SMOKE DAMPERS NOT | | SHOWN AT DUCTS PENETRATED FIRE AND SMOKE BARRIERS AND | | PARTITIONS. IT MAY BE HELPFUL TO OVERLAY THE WALLS ON | | THE MECHANICAL PLAN THAT ARE FIRE OR SMOKE RATED, AND | | AGAIN, KEY NOTES ARE HELPFUL FOR LOCATING REQUIRED | | DAMPERS AND DUCT SMOKE DETECTORS. C) IDENTIFY AND LABEL | | ALL DUCT SHAFTS AND PIPE CHASES. D) LABEL ALL DIFFUSERS | | AND RETURN GRILLS ON THE PLANS AND INCLUDE THE CFM | | AIRFLOW RATES- MANY OF THE SLOT AND CEILING DIFFUSERS | | ON THE PLANS ARE NOT LABELED. E) MANY OF THE BRANCH AND | | TRANSFER DUCT SIZES ARE NOT INDICATED AS WELL AS SOME | | OF THE MAIN DUCT TRUNKS. F) INSTALLATION AND SUPPORT | | DETAILS FOR THE AIR HANDLERS NOT SHOWN. G) SHOW ACCESS | | PANEL LOCATIONS FOR MAINTENANCE AND REPLACEMENT OF THE | | AIR HANDLERS AND ALL OTHER ABOVE CEILING EQUIPMENT. H) | | IDENTIFY ALL ROOMS AND SPACES ON THE PLANS (THE PRINT | | IS VERY FAINT). PLEASE REVIEW AND REVISE THE PLANS | | ACCORDINGLY. | | | | 15) PLEASE REVIEW SECTION C403.2.4.4 (SHUTOFF DAMPER | | CONTROLS), AND C403.2.5.1 (DEMAND CONTROLLED | | VENTILATION) AND REVISE THE PLANS TO SHOW COMPLIANCE | | WHERE REQUIRED. | | | | 16) REFER TO SECTION 307 AND PROVIDE PRIMARY AND | | SECONDARY CONDENSATE DISPOSAL PLANS FOR THE AIR | | HANDLERS. | | | | 17) PROVIDE EQUIPMENT SCHEDULES FOR THE BOILERS AND | | SHOW THEIR LOCATIONS ON THE PLANS. | | | | 18) SHOW THE LOCATION OF THE ERU-1S ON THE PLANS. | | | | 19) THE MECHANICAL REVIEW IS SUSPENDED AT THIS TIME DUE | | TO DEFICIENCIES IN THE PLANS AND THE LACK OF | | SUBMITTALS. PLEASE NOTE THAT THERE MAY BE ADDITIONAL | | COMMENTS AFTER REVISED AND CORRECTED PLANS ARE | | RESUBMITTED FOR REVIEW. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2017-03-06 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-03-06 |
Time |
16:18 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-03-06 |
Time |
16:18 |
Sent To |
|
|
Notes |
2017-03-06 16:19:01 | PROVISO 2ND REQUEST | | PLUMBING | | 1. PROVIDE A CLEAR AND CONCISE ISOMETRIC DRAWING FOR | | THE STORM DRAIN SHOWING ALL SIZES SLOPE OF PIPE, SQ FT | | AND LEVEL. THE ONE IN THE PLAN SET IS NOT CLEAR AND | | DOES NOT SHOW ALL THE REQUIRED INFORMATION. MUST BE | | APPROVED BY BUILDING DEPARTMENT PRIOR TO FIST ROUGH | | INSPECTION. | | GAS | | 1. PROVIDE COMBUSTION AIR CALCULATIONS FOR GAS | | APPLIANCES IN THE KITCHEN. MUST BE APPROVED BY BUILDING | | DEPARTMENT PRIOR TO FIST ROUGH INSPECTION. | | 2. PROVIDE MANUFACTURE SPECIFICATIONS AND INSTALLATION | | GUIDE FOR GAS APPLIANCES. MUST BE APPROVED BY BUILDING | | DEPARTMENT PRIOR TO FIST ROUGH INSPECTION. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | | | | | | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2017-01-20 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-01-20 |
Time |
08:50 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-01-19 |
Time |
13:20 |
Sent To |
|
|
Notes |
2017-01-20 08:52:17 | PROVISO | | PLUMBING | | 1. PROVIDE A CLEAR AND CONCISE ISOMETRIC DRAWING FOR | | THE STORM DRAIN SHOWING ALL SIZES SLOPE OF PIPE, SQ FT | | AND LEVEL. THE ONE IN THE PLAN SET IS NOT CLEAR AND | | DOES NOT SHOW ALL THE REQUIRED INFORMATION. MUST BE | | APPROVED BY BUILDING DEPARTMENT PRIOR TO FIST ROUGH | | INSPECTION. | | GAS | | 1. PROVIDE COMBUSTION AIR CALCULATIONS FOR GAS | | APPLIANCES IN THE KITCHEN. MUST BE APPROVED BY BUILDING | | DEPARTMENT PRIOR TO FIST ROUGH INSPECTION. | | 2. PROVIDE MANUFACTURE SPECIFICATIONS AND INSTALLATION | | GUIDE FOR GAS APPLIANCES. MUST BE APPROVED BY BUILDING | | DEPARTMENT PRIOR TO FIST ROUGH INSPECTION. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | | | | | | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2016-10-27 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-10-27 |
Time |
14:45 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-10-25 |
Time |
12:43 |
Sent To |
|
|
Notes |
2016-10-27 14:47:02 | 2ND REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: 2ND REQUEST | | | | 1.NOT COMPLIED. IT APPEARS THAT THE FIXTURE COUNT IS TO | | LOW FOR THE OCCUPANT LOAD. PLEASE PROVIDE A BREAKDOWN | | OF FIXTURES REQUIRED AND FIXTURES PROVIDED. PER FBC PL | | TABLE 403.1 | | USING THE OCCUPANT LOAD FROM THE LIFE SAFETY PAGES THE | | REQUIRED NUMBER OF WATER CLOSETS FOR THE WOMEN WOULD BE | | 26 TOTAL I CAN ONLY FIND 16 ON THE PLAN. THE REQUIRED | | NUMBER OF WATER CLOSETS FOR THE MEN IS 16 I FOUND 12 ON | | THE PLAN. IF YOU PROVIDE A BREAKDOWN SHOWING OCCUPANT | | LOAD FOR EACH OCCUPANT TYPE AND THE REQUIRED FIXTURE | | COUNT AND WHAT IS PROVIDED> IT MIGHT CLARIFY THIS | | PROBLEM. | | | | 3. NOT COMPLIED SHT. P101-104 PLEASE IDENTIFY PIPING | | AND SIZES. PERWPB AMEND. TO FBC 107.2.1 | | | | 6. NOT COMPLIED PROVIDE ISOMETRIC RISER DIAGRAM FOR ANY | | NEW STORM WITH SQFT. THAT IS BEING DRAINED ON EACH | | PIPE. PER WPB AMEND. TO FBC 107.3.5.1.3(13) | | SHT. P505 | | A) THEIR ARE PIPES ON THE RISER DIAGRAM THAT END WITH | | NO INDICATION OF WHERE THEY GO OR WHAT SIZE PLEASE | | IDENTIFY EACH PEACE OF PIPE TO COINCIDE WITH A LOCATION | | . | | B) PROVIDE SQUARE FOOTAGE AND SLOPE ON EACH SECTION OF | | PIPE. | | C) SHOW LEVEL AND LOCATION OF EACH ROOF DRAIN. | | | | 11.NOT COMPLIED SHT A703 DETAIL 3A SHOW GRAB BARS IN | | AMBULATORY TOILET COMPARTMENT.PER FBC ACC. 604.8.2.3 | | | | NEW COMMENTS: | | | | 1. SHT. P504 THE VENTS ON THE FLOOR SINKS CAN NOT RUN | | HORIZONTALLY. PER FBC PL SEC 905.3 VENT CONNECTION TO | | DRAINAGE SYSTEM. | | EVERY DRY VENT CONNECTING TO A HORIZONTAL DRAIN SHALL | | CONNECT ABOVE THE CENTERLINE OF THE HORIZONTAL DRAIN | | PIPE. | | | | 905.4 VERTICAL RISE OF VENT. | | EVERY DRY VENT SHALL RISE VERTICALLY TO A POINT NOT | | LESS THAN 6 INCHES (152 MM) ABOVE THE FLOOD LEVEL RIM | | OF THE HIGHEST TRAP OR TRAPPED FIXTURE BEING VENTED. | | | | 2.SHT. P121.5-P123.8 WHAT ARE THE SYMBOLS OF THE | | CIRCLES WITH THE P50-P58 PLEASE SHOW ON THE PLAN. PER | | WPB AMEND. TO FBC 107.2.1 | | | | 3. ON THE SANITARY RISER DIAGRAM PLEASE PROVIDE A WAY | | TO IDENTIFY THE STACKS TO COINCIDE WITH THE FLOOR | | PLANS. PER WPB AMEND. TO FBC 107.2.1 | | | | 4. PROVIDE A ISOMETRIC RISER DIAGRAM FOR THE KITCHEN | | PLUMBING.. PER WPB AMEND. TO FBC 107.2.1 | | | | 5. PLEASE EXPAND OR ENLARGE ALL ISOMETRIC DRAWINGS TO | | INSURE THAT THEY CAN BE EASILY READ BY THE INSPECTORS | | IN THE FIELD. PER WPB AMEND. TO FBC 107.2.1 | | | | | | DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND | | THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON | | RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS. | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | | | | | | | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2016-06-28 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-06-28 |
Time |
11:13 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-06-21 |
Time |
14:53 |
Sent To |
|
|
Notes |
2016-06-28 14:15:49 | 1ST REVIEW | | | | | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | 1. IT APPEARS THAT THE FIXTURE COUNT IS TO LOW FOR THE | | OCCUPANT LOAD. PLEASE PROVIDE A BREAKDOWN OF FIXTURES | | REQUIRED AND FIXTURES PROVIDED. PER FBC PL TABLE 403.1 | | | | 2. SEPARATE PERMITS REQUIRED FOR ANY NEW BACKFLOW | | DEVICES AT METERS. PER WPB UTILITIES | | | | 3. SHT. P101-104 PLEASE IDENTIFY PIPING AND SIZES. | | PERWPB AMEND. TO FBC 107.2.1 | | | | 4. SHT. P122.7-123.7-122.8-123.8 THE NOTE ON THE GAS | | MAIN AND COLD WATER MAIN READS 3IN GAS AND CW THE GAS | | MAIN IS SHOWN AS 2IN. IN OTHER AREAS PLEASE CLARIFY. | | PER WPB AMEND. TO FBC 107.2.1 | | | | 5. PLEASE PROVIDE SEPARATE SANITARY AND WATER ISOMETRIC | | DRAWINGS FOR THE KITCHEN, COFFEE BAR AND KITCHENETTE RM | | 212 PER WPB AMEND. TO FBC 107.3.5.1.3(13) | | | | 6. PROVIDE ISOMETRIC RISER DIAGRAM FOR ANY NEW STORM | | WITH SQFT. THAT IS BEING DRAINED ON EACH PIPE. PER WPB | | AMEND. TO FBC 107.3.5.1.3(13) | | | | 7. SHT. P503 RISER FO RUMENS RM 143 THE URINALS ARE | | SHOWN AS WC-1 PLEASE CLARIFY. PER WPB AMEND. TO FBC | | 107.2.1 | | | | 8. SHT. 503 SHOW FAMILY BATHROOM ON RISER DIAGRAM. PER | | WPB AMEND. TO FBC 107.2.1 | | | | 9. PROVIDE SIZING CALCULATIONS FOR GREASE INTERCEPTOR. | | PER WPB AMEND. TO FBC 107.2.1 | | | | 10. SHT. 501 DETAIL 13 PLEASE COMPLY WITH GREASE TRAP | | DETAIL | | NOTE | | 1) INLET INVERT SHALL DISCHARGE A MINIMUM OF 2 ?? ABOVE | | THE LIQUID LEVEL LINE AND OUTLET PIPE SHALL HAVE A TEE | | WITH A MINIMUM DIAMETER OF 4? TO WITHIN 8? OF THE | | BOTTOM OF THE TANK. | | 2) MANHOLES SHALL BE PROVIDED OVER THE INLET AND OUTLET | | OF EACH INTERCEPTOR AND BE BROUGHT TO GRADE. MINIMUM | | SIZE OF MANHOLES SHALL BE 24?. | | 3) LID TYPE: | | A) REGULAR ? FOUR-INCH THICK REINFORCED CONCRETE OR | | APPROVED EQUIVALENT. | | B) TRAFFIC BEARING ? SIX-INCH THICK REINFORCED CONCRETE | | OR APPROVED EQUIVALENT. | | 4) A TWO-WAY CLEANOUT TEE, BROUGHT TO GRADE, SHALL BE | | INSTALLED ENTERING AND LEAVING EACH GREASE INTERCEPTOR. | | 5) CLEANOUTS INSTALLED IN VEHICULAR TRAFFIC PAVED AREAS | | SHALL BE PROTECTED BY USE OF A CLEANOUT BOX WITH METAL | | LID. | | 6) WALLS SHALL BE A MINIMUM OF 3? THICK AND BOTTOM | | SHALL BE A MINIMUM OF 4? THICK REINFORCED CONCRETE. | | 7) TANK MUST BE TRAFFIC BEARING. | | 8) PROVIDE ENGINEER OF RECORD APPROVED DETAIL/SHOP | | DRAWINGS. | | 9) SIZE: SIZE OF THE GREASE TRAP SHALL BE BASED UPON | | THE ANTICIPATED FLOW RATE, WATER TEMPERATURE AND GREASE | | CONCENTRATION. ADEQUATE DETENTION TIME SHALL BE | | PROVIDED TO ALLOW THE GREASE TO BE DEPOSITED WITHIN THE | | GREASE TRAP BEFORE ENTERING THE CITY WASTEWATER SYSTEM. | | MINIMUM CAPACITY SIZE: 750 GALLONS. MAXIMUM CAPACITY | | SIZE: 1250 GALLONS. | | FOR SIZE APPROVAL, PLEASE CONTACT THE UTILITIES | | DEPARTMENT, ENVIRONMENTS COMPLIANCE (HOLLY MCGRATH | | LABORATORY) SUPERVISOR: (561) 822-2271 E-MAIL: | | [email protected] | | 10) ALTERNATE MATERIALS AND DESIGN SHALL BE SUBMITTED | | FOR INDIVIDUAL APPROVAL. | | | | 11. SHT A703 DETAIL 3A SHOW GRAB BARS IN AMBULATORY | | TOILET COMPARTMENT.PER FBC ACC. 604.8.2.3 | | | | | | DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND | | THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON | | RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS. | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | | | | | | | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2017-03-06 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-03-04 |
Time |
08:26 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2017-03-06 16:32:23 | 3/6/17 SHEETS THAT ARE MISSING ELECTRONIC SIGNATURE | | FP-100, FP-501, FP-121M.7, P-501, P502, P-504, P-505, | | P-121.5 | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | 2017-03-04 08:26:05 | SAT. MARCH 04/ 2017. BUILDING 4TH SIGNATURE REVIEW, | | SHEETS MISSING THE ELECTRONIC SIGNATURE: | | SHEETS ARCHITECTURAL & STRUCTURALS SHEETS MISSING | | SIGNATURES.61G15-23.005 PROCEDURES FOR SIGNING AND | | SEALING ELECTRONICALLY TRANSMITTED PLANS, | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.JAMES A. | | WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2017-03-20 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2017-03-20 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2017-03-20 |
Time |
13:52 |
Sent To |
|
|
Notes |
2016-10-29 10:57:48 | BUILDING 2ND SIGNATURE REVIEW, SHEETS MISSING THE | | ELECTRONIC SIGNATURE: | | SHEETS ARCHITECTURAL & STRUCTURALS SHEETS MISSING | | SIGNATURES.61G15-23.005 PROCEDURES FOR SIGNING AND | | SEALING ELECTRONICALLY TRANSMITTED PLANS, | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.JAMES A. | | WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | |
|
|
Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
Rev No |
2 |
Status |
P |
Date |
2016-10-28 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-10-28 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-10-28 |
Time |
16:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
Rev No |
1 |
Status |
F |
Date |
2016-07-11 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-07-11 |
Time |
07:38 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-07-11 |
Time |
07:38 |
Sent To |
|
|
Notes |
2016-07-11 07:39:19 | SEE BUILDING COMMENT # 1. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2017-03-13 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2017-03-13 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2017-03-13 |
Time |
15:31 |
Sent To |
|
|
Notes |
2017-03-13 15:36:56 | ZONING PLAN REVIEW | | ___________________________________________ | | | | DATE OF REVIEW: 03.13.2017 | | PERMIT NO.: 16050912 | | ADDRESS: 1451 S OLIVE AVENUE | | CONTRACTOR/CONTACT: MICHAEL IZZO | | TELEPHONE NO.: | | SCOPE OF REVIEW: NORTON MUSEUM EXPANSION | | ___________________________________________ | | | | REVIEW STATUS: PASSED WITH PROVISOS | | ___________________________________________ | | | | THE SCOPE OF THIS APPROVAL IS FOR CONSTRUCTION OF THE | | BUILDING ONLY...AND DOES NOT INCLUDE ANY SITE WORK, | | LANDSCAPING, ETC. THIS REVIEW HAS BEEN PASSED SUBJECT | | TO THE FOLLOWING PROVISOS: | | | | 1. ANY REQUIRED EASEMENTS (I.E. DRAINAGE, UTILITIES, | | PUBLIC ACCESS, ETC.) SHALL BE PROVIDED VIA PLAT OR | | SEPARATE LEGAL INSTRUMENT. | | | | 2. ALL CHAINLINK FENCING SHALL BE COMPLETELY SCREENED | | FROM VIEW UTILIZING SHRUBS, HEDGING, OR OTHER | | ACCEPTABLE LANDSCAPE MATERIAL. | | | | 3. THE DEVELOPER SHALL BE RESPONSIBLE FOR THE | | INSTALLATION OF IRRIGATION AND LANDSCAPING WITHIN THE | | RIGHTS-OF-WAY ADJACENT TO THE CSPD, AND SHALL BE | | RESPONSIBLE FOR THE MAINTENANCE OF SUCH IMPROVEMENTS, | | IN PERPETUITY. | | | | 4. ALL UTILITY ELEMENTS (I.E. BACKFLOW PREVENTERS, | | ETC.) SHALL BE SCREENED WITH LANDSCAPING TO THE MAXIMUM | | EXTENT ALLOWED BY THE CONTROLLING UTILITY AGENCY. IT | | APPEARS THAT THERE ARE CONFLICTS BETWEEN SUCH UTILITY | | ELEMENTS AND FENCING, ETC. ALL CONFLICTS SHALL BE | | RESOLVED AND SUFFICIENT SCREENING PROVIDED. | | | | 5. IMPROVEMENTS WITHIN THE SOUTH DIXIE RIGHT-OF-WAY | | (INCLUDING NEW CURBING, BOLLARDS, LIGHTING, SIDEWALKS, | | ETC.) SHALL BE SUBJECT TO PERMITTING BY FDOT. | | MAINTENANCE AGREEMENTS MAY BE REQUIRED. | | | | 6. ALL IMPROVEMENTS WITHIN THE JEFFERSON ROAD, | | CRANESNEST WAY, AND SOUTH OLIVE AVENUE RIGHT-OF-WAY | | (I.E. ON-STREET PARKING, RESURFACING, ETC.) SHALL BE | | SUBJECT TO A CITY OF WPB RIGHT-OF-WAY PERMIT, OBTAINED | | FROM THE CITY'S ENGINEERING DEPARTMENT. | | | | 7. ALL SIGNAGE (WALL MOUNTED, FREESTANDING, ETC.) SHALL | | BE SUBMITTED AND REVIEWED UNDER SEPARATE PERMITS. | | | | 8. PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF | | OCCUPANCY: | | | | A. THE PROPERTY SHALL BE RE-PLATTED IN ACCORDANCE WITH | | ALL APPLICABLE STATUTES, REGULATIONS, AND THE CITY?S | | POLICIES AND PROCEDURES. | | | | B. JEFFERSON ROAD, BETWEEN SOUTH DIXIE HIGHWAY AND | | SOUTH OLIVE AVENUE SHALL BE MILLED AND RESURFACED. ALL | | APPLICABLE PERMITS SHALL BE OBTAINED FROM THE CITY?S | | PUBLIC WORKS DEPARTMENT. | | | | C. ANY DAMAGE TO EXISTING UTILITIES RESULTING FROM THE | | DEVELOPER'S CONSTRUCTION ACTIVITIES SHALL BE REPAIRED, | | AT THE DEVELOPER'S EXPENSE. | | | | THE FOLLOWING COMMENTS SHALL BE ADDRESSED PRIOR TO | | AUTHORIZING ANY SITE WORK (AS REFERENCED ABOVE): | | | | 9. A MINOR AMENDMENT SHALL BE APPROVED BY THE | | DEVELOPMENT SERVICES DEPARTMENT - PLANNING DIVISION | | PROVIDING DETAILED LANDSCAPE PLANS FOR CONSTRUCTION | | IMPLEMENTATION. SUCH PLANS SHALL: | | | | A. SPECIFY THE EXACT SPECIES AND LOCATION OF ALL | | TREES, SHRUBS, HEDGES, GROUNDCOVER, ETC. AND BE IN | | COMPLIANCE WITH ARTICLE XIV OF THE CITY?S ZONING AND | | LAND DEVELOPMENT REGULATIONS, EXCEPT FOR THOSE | | PREVIOUSLY WAIVERS GRANTED | | | | B. IDENTIFY THE LOCATION OF ALL TREES/PALMS THAT ARE | | TO BE RELOCATED ON-SITE; | | | | C. IDENTIFY THE LOCATIONS REQUIRED FOR ROOT BARRIERS; | | | | I. INCLUDE A SHRUB PLANTING PLAN FOR THE OFF-SITE | | PARKING LOT LOCATED ON THE WEST SIDE OF SOUTH DIXIE | | HIGHWAY; | | | | II. PROVIDE THE DETAILED LANDSCAPE IMPROVEMENTS | | PROPOSED WITHIN THE SOUTH DIXIE HIGHWAY RIGHT-OF-WAY. | | PLEASE NOTE THAT ANY PLANTINGS SHALL NOT IMPEDE WITH | | THE SITE DISTANCE AND SHALL BE APPROVED BY FDOT. | | | | 10. ALL LANDSCAPING SHALL BE SUBMITTED AND REVIEWED AS | | A SEPARATE PERMIT APPLICATION, SUBMITTED TO THE CITY'S | | BUILDING DIVISION. | | | | 11. PHOTOMETRIC PLAN SHALL BE PROVIDED AND SHALL NOT | | EXCEED 1.0 FOOTCANDLES WHEN MEASURED AT THE PROPERTY | | LINE. | | | | 12. THE DATA TABLE ON SHEET L102 SHOWS SIGNIFICANT | | CHANGES FROM WHAT WAS APPROVED BY THE CITY COMMISSION. | | MODIFICATIONS SHALL BE APPROVED THROUGH A MINOR PD | | AMENDMENT, UNLESS TRIGGERING ONE OF THE PROVISIONS OF | | SEC. 94-207(E)(1) OF THE CITY'S ZONING AND LAND | | DEVELOPMENT REGULATIONS. ALSO, THERE ARE | | INCONSISTENCIES IN THE DATA TABLE, SUCH AS SQUARE | | FOOTAGE FOR THE MUSEUM. NOTE THAT AN INCREASE IN SQUARE | | FOOTAGE MAY NECESSITATE ADDITIONAL PARKING, ETC. IN | | YOUR RESPONSE TO THIS COMMENT PREVIOUSLY, IT WAS | | INDICATED THAT SOME OF THE EXISTING SHEDS ARE TO BE | | PARTIALLY DEMOLISHED AND THAT THE NEW SERVICE YARD SHED | | IS LARGER. THERE ARE A COUPLE ISSUES WITH THIS...THE | | EXISTING SHEDS ARE LOCATED WITHIN THE BOUNDARIES OF THE | | HISTORIC SINGLE FAMILY HOMES AND REQUIRE APPROVAL OF | | THE CITY'S HISOTORIC PRESERVATION DIVISION PRIOR TO ANY | | DEMOLITION / RENOVATION. ADDITIONALLY, THESE WERE NOT | | COUNTED TOWARD THE NORTON'S PARKING REQUIREMENTS AS | | THEY WERE NOT DEEMED A PART OF THE MUSEUM ITSELF; | | HOWEVER, THE SERVICE YARD SHED WAS AND IT'S INCREASE IN | | SIZE DOES AFFECT THE PARKING REQUIREMENT, ETC. | | | | 13. THROUGHOUT THE PERMIT SET VARIOUS TRADES ARE USING | | DIFFERENT VARIATIONS OF SITE / LANDSCAPE PLANS AS THE | | BASIS FOR THEIR DRAWINGS. ALL PLANS ACROSS ALL TRADES | | NEED TO BE CONSISTENT AND MATCH...AND THEY ALL SHOULD | | MATCH THOSE PLANS THAT HAVE BEEN APPROVED DURING THE | | PLANNED DEVELOPMENT (PD) PROCESS. | | | | 14. AS INDICATED PREVIOUSLY, STAFF HAS SIGNFICANT | | CONCERNS REGARDING SOME OF THE PROPOSED REVISIONS TO | | THE SITE / LANDSCAPE PLANS, SUCH AS RECONFIGURATION OF | | THE PARKING / DROP-OFF AT THE CORNER OF JEFFERSON AND | | DIXIE, PROPOSED HEDGING / FENCING, ETC. THESE ISSUES | | NEED TO BE RESOLVED, INCORPORATED INTO THE REVISED | | PLANS, AND APPROVED THROUGH THE PLANNED DEVELOPMENT | | (PD) PROCESS BEFORE PERMITTING SUCH WORK. | | ___________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ___________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT - PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1448 | | F: 561.822.1460 | | | | E: [email protected] | | | | W: WPB.ORG | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2017-01-19 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2017-01-19 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2017-01-19 |
Time |
14:50 |
Sent To |
|
|
Notes |
2017-01-19 15:30:06 | ZONING PLAN REVIEW | | ___________________________________________ | | | | DATE OF REVIEW: 01.19.2017 | | PERMIT NO.: 16050912 | | ADDRESS: 1451 S OLIVE AVENUE | | CONTRACTOR/CONTACT: MICHAEL IZZO | | TELEPHONE NO.: | | SCOPE OF REVIEW: NORTON MUSEUM EXPANSION | | ___________________________________________ | | | | REVIEW STATUS: FAILED | | ___________________________________________ | | | | ZONING STAFF DOES NOT HAVE ANY OBJECTION TO THE SCOPE | | OF WORK PERTAINING TO THE CONFINES OF THE BUILDING AND | | WILL PASS ITS REVIEW (SUBJECT TO PROVISOS) ONCE THE | | PERMIT IS READY TO BE ISSUED BY THE OTHER TRADES. | | PLEASE NOTE THAT CONCERNS / COMMENTS REMAIN WITH REGARD | | TO THE PROPOSED SITE WORK (PARKING LOTS, SIDEWALKS, | | LANDSCAPING, ETC.) AND WILL NEED TO BE RESOLVED BEFORE | | ZONING STAFF AUTHORIZES THE PROJECT TO PROCEED WITH | | THOSE ASPECTS OF THE PROJECT. | | | | THE FOLLOWING COMMENTS WILL REMAIN AS PROVISOS SO THAT | | ALL PARTIES ARE AWARE THROUGHOUT THE DURATION OF THE | | CONSTRUCTION: | | | | 1. ANY REQUIRED EASEMENTS (I.E. DRAINAGE, UTILITIES, | | PUBLIC ACCESS, ETC.) SHALL BE PROVIDED VIA PLAT OR | | SEPARATE LEGAL INSTRUMENT. | | | | 2. ALL CHAINLINK FENCING SHALL BE COMPLETELY SCREENED | | FROM VIEW UTILIZING SHRUBS, HEDGING, OR OTHER | | ACCEPTABLE LANDSCAPE MATERIAL. | | | | 3. THE DEVELOPER SHALL BE RESPONSIBLE FOR THE | | INSTALLATION OF IRRIGATION AND LANDSCAPING WITHIN THE | | RIGHTS-OF-WAY ADJACENT TO THE CSPD, AND SHALL BE | | RESPONSIBLE FOR THE MAINTENANCE OF SUCH IMPROVEMENTS, | | IN PERPETUITY. | | | | 4. ALL UTILITY ELEMENTS (I.E. BACKFLOW PREVENTERS, | | ETC.) SHALL BE SCREENED WITH LANDSCAPING TO THE MAXIMUM | | EXTENT ALLOWED BY THE CONTROLLING UTILITY AGENCY. IT | | APPEARS THAT THERE ARE CONFLICTS BETWEEN SUCH UTILITY | | ELEMENTS AND FENCING, ETC. ALL CONFLICTS SHALL BE | | RESOLVED AND SUFFICIENT SCREENING PROVIDED. | | | | 5. IMPROVEMENTS WITHIN THE SOUTH DIXIE RIGHT-OF-WAY | | (INCLUDING NEW CURBING, BOLLARDS, LIGHTING, SIDEWALKS, | | ETC.) SHALL BE SUBJECT TO PERMITTING BY FDOT. | | MAINTENANCE AGREEMENTS MAY BE REQUIRED. | | | | 6. ALL IMPROVEMENTS WITHIN THE JEFFERSON ROAD, | | CRANESNEST WAY, AND SOUTH OLIVE AVENUE RIGHT-OF-WAY | | (I.E. ON-STREET PARKING, RESURFACING, ETC.) SHALL BE | | SUBJECT TO A CITY OF WPB RIGHT-OF-WAY PERMIT, OBTAINED | | FROM THE CITY'S ENGINEERING DEPARTMENT. | | | | 7. ALL SIGNAGE (WALL MOUNTED, FREESTANDING, ETC.) SHALL | | BE SUBMITTED AND REVIEWED UNDER SEPARATE PERMITS. | | | | 8. PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF | | OCCUPANCY: | | | | A. THE PROPERTY SHALL BE RE-PLATTED IN ACCORDANCE WITH | | ALL APPLICABLE STATUTES, REGULATIONS, AND THE CITY?S | | POLICIES AND PROCEDURES. | | | | B. JEFFERSON ROAD, BETWEEN SOUTH DIXIE HIGHWAY AND | | SOUTH OLIVE AVENUE SHALL BE MILLED AND RESURFACED. ALL | | APPLICABLE PERMITS SHALL BE OBTAINED FROM THE CITY?S | | PUBLIC WORKS DEPARTMENT. | | | | C. ANY DAMAGE TO EXISTING UTILITIES RESULTING FROM THE | | DEVELOPER'S CONSTRUCTION ACTIVITIES SHALL BE REPAIRED, | | AT THE DEVELOPER'S EXPENSE. | | | | THE FOLLOWING COMMENTS SHALL BE ADDRESSED PRIOR TO | | AUTHORIZING ANY SITE WORK (AS REFERENCED ABOVE): | | | | 5. A MINOR AMENDMENT SHALL BE APPROVED BY THE | | DEVELOPMENT SERVICES DEPARTMENT - PLANNING DIVISION | | PROVIDING DETAILED LANDSCAPE PLANS FOR CONSTRUCTION | | IMPLEMENTATION. SUCH PLANS SHALL: | | | | A. SPECIFY THE EXACT SPECIES AND LOCATION OF ALL | | TREES, SHRUBS, HEDGES, GROUNDCOVER, ETC. AND BE IN | | COMPLIANCE WITH ARTICLE XIV OF THE CITY?S ZONING AND | | LAND DEVELOPMENT REGULATIONS, EXCEPT FOR THOSE | | PREVIOUSLY WAIVERS GRANTED | | | | B. IDENTIFY THE LOCATION OF ALL TREES/PALMS THAT ARE | | TO BE RELOCATED ON-SITE; | | | | C. IDENTIFY THE LOCATIONS REQUIRED FOR ROOT BARRIERS; | | | | I. INCLUDE A SHRUB PLANTING PLAN FOR THE OFF-SITE | | PARKING LOT LOCATED ON THE WEST SIDE OF SOUTH DIXIE | | HIGHWAY; | | | | II. PROVIDE THE DETAILED LANDSCAPE IMPROVEMENTS | | PROPOSED WITHIN THE SOUTH DIXIE HIGHWAY RIGHT-OF-WAY. | | PLEASE NOTE THAT ANY PLANTINGS SHALL NOT IMPEDE WITH | | THE SITE DISTANCE AND SHALL BE APPROVED BY FDOT. | | | | 6. ON SHEET C102, THERE ARE SIGNS SHOWN IN THE SOUTH | | DIXIE HIGHWAY PEDESTRIAN SIDEWALK. PLEASE CLARIFY. | | | | 7. ALL LANDSCAPING SHALL BE SUBMITTED AND REVIEWED AS A | | SEPARATE PERMIT APPLICATION, SUBMITTED TO THE CITY'S | | BUILDING DIVISION. | | | | 8. PHOTOMETRIC PLAN SHALL BE PROVIDED AND SHALL NOT | | EXCEED 1.0 FOOTCANDLES WHEN MEASURED AT THE PROPERTY | | LINE. | | | | 9. THE DATA TABLE ON SHEET L102 SHOWS SIGNIFICANT | | CHANGES FROM WHAT WAS APPROVED BY THE CITY COMMISSION. | | MODIFICATIONS SHALL BE APPROVED THROUGH A MINOR PD | | AMENDMENT, UNLESS TRIGGERING ONE OF THE PROVISIONS OF | | SEC. 94-207(E)(1) OF THE CITY'S ZONING AND LAND | | DEVELOPMENT REGULATIONS. ALSO, THERE ARE | | INCONSISTENCIES IN THE DATA TABLE, SUCH AS SQUARE | | FOOTAGE FOR THE MUSEUM. NOTE THAT AN INCREASE IN SQUARE | | FOOTAGE MAY NECESSITATE ADDITIONAL PARKING, ETC. IN | | YOUR RESPONSE TO THIS COMMENT PREVIOUSLY, IT WAS | | INDICATED THAT SOME OF THE EXISTING SHEDS ARE TO BE | | PARTIALLY DEMOLISHED AND THAT THE NEW SERVICE YARD SHED | | IS LARGER. THERE ARE A COUPLE ISSUES WITH THIS...THE | | EXISTING SHEDS ARE LOCATED WITHIN THE BOUNDARIES OF THE | | HISTORIC SINGLE FAMILY HOMES AND REQUIRE APPROVAL OF | | THE CITY'S HISOTORIC PRESERVATION DIVISION PRIOR TO ANY | | DEMOLITION / RENOVATION. ADDITIONALLY, THESE WERE NOT | | COUNTED TOWARD THE NORTON'S PARKING REQUIREMENTS AS | | THEY WERE NOT DEEMED A PART OF THE MUSEUM ITSELF; | | HOWEVER, THE SERVICE YARD SHED WAS AND IT'S INCREASE IN | | SIZE DOES AFFECT THE PARKING REQUIREMENT, ETC. | | | | 10. THROUGHOUT THE PERMIT SET VARIOUS TRADES ARE USING | | DIFFERENT VARIATIONS OF SITE / LANDSCAPE PLANS AS THE | | BASIS FOR THEIR DRAWINGS. ALL PLANS ACROSS ALL TRADES | | NEED TO BE CONSISTENT AND MATCH...AND THEY ALL SHOULD | | MATCH THOSE PLANS THAT HAVE BEEN APPROVED DURING THE | | PLANNED DEVELOPMENT (PD) PROCESS. | | | | 11. AS INDICATED PREVIOUSLY, STAFF HAS SIGNFICANT | | CONCERNS REGARDING SOME OF THE PROPOSED REVISIONS TO | | THE SITE / LANDSCAPE PLANS, SUCH AS RECONFIGURATION OF | | THE PARKING / DROP-OFF AT THE CORNER OF JEFFERSON AND | | DIXIE, PROPOSED HEDGING / FENCING, ETC. THESE ISSUES | | NEED TO BE RESOLVED, INCORPORATED INTO THE REVISED | | PLANS, AND APPROVED THROUGH THE PLANNED DEVELOPMENT | | (PD) PROCESS BEFORE PERMITTING SUCH WORK. | | ___________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ___________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT - PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1448 | | F: 561.822.1460 | | | | E: [email protected] | | | | W: WPB.ORG | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2016-11-16 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2016-11-16 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2016-11-16 |
Time |
14:05 |
Sent To |
|
|
Notes |
2016-11-16 14:05:04 | ZONING PLAN REVIEW | | ___________________________________________ | | | | DATE OF REVIEW: 11.16.2016 | | PERMIT NO.: 16050912 | | ADDRESS: 1451 S OLIVE AVENUE | | CONTRACTOR/CONTACT: MICHAEL IZZO | | TELEPHONE NO.: | | SCOPE OF REVIEW: NORTON MUSEUM EXPANSION | | ___________________________________________ | | | | REVIEW STATUS: FAILED | | ___________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. ANY REQUIRED EASEMENTS (I.E. DRAINAGE, UTILITIES, | | PUBLIC ACCESS, ETC.) SHALL BE PROVIDED VIA PLAT OR | | SEPARATE LEGAL INSTRUMENT. | | | | 2. ALL CHAINLINK FENCING SHALL BE COMPLETELY SCREENED | | FROM VIEW UTILIZING SHRUBS, HEDGING, OR OTHER | | ACCEPTABLE LANDSCAPE MATERIAL. | | | | 3. THE DEVELOPER SHALL BE RESPONSIBLE FOR THE | | INSTALLATION OF IRRIGATION AND LANDSCAPING WITHIN THE | | RIGHTS-OF-WAY ADJACENT TO THE CSPD, AND SHALL BE | | RESPONSIBLE FOR THE MAINTENANCE OF SUCH IMPROVEMENTS, | | IN PERPETUITY. | | | | 4. ALL UTILITY ELEMENTS (I.E. BACKFLOW PREVENTERS, | | ETC.) SHALL BE SCREENED WITH LANDSCAPING TO THE MAXIMUM | | EXTENT ALLOWED BY THE CONTROLLING UTILITY AGENCY. IT | | APPEARS THAT THERE ARE CONFLICTS BETWEEN SUCH UTILITY | | ELEMENTS AND FENCING, ETC. ALL CONFLICTS SHALL BE | | RESOLVED AND SUFFICIENT SCREENING PROVIDED. | | | | 5. A MINOR AMENDMENT SHALL BE APPROVED BY THE | | DEVELOPMENT SERVICES DEPARTMENT - PLANNING DIVISION | | PROVIDING DETAILED LANDSCAPE PLANS FOR CONSTRUCTION | | IMPLEMENTATION. SUCH PLANS SHALL: | | | | A. SPECIFY THE EXACT SPECIES AND LOCATION OF ALL | | TREES, SHRUBS, HEDGES, GROUNDCOVER, ETC. AND BE IN | | COMPLIANCE WITH ARTICLE XIV OF THE CITY?S ZONING AND | | LAND DEVELOPMENT REGULATIONS, EXCEPT FOR THOSE | | PREVIOUSLY WAIVERS GRANTED | | | | B. IDENTIFY THE LOCATION OF ALL TREES/PALMS THAT ARE | | TO BE RELOCATED ON-SITE; | | | | C. IDENTIFY THE LOCATIONS REQUIRED FOR ROOT BARRIERS; | | | | I. INCLUDE A SHRUB PLANTING PLAN FOR THE OFF-SITE | | PARKING LOT LOCATED ON THE WEST SIDE OF SOUTH DIXIE | | HIGHWAY; | | | | II. PROVIDE THE DETAILED LANDSCAPE IMPROVEMENTS | | PROPOSED WITHIN THE SOUTH DIXIE HIGHWAY RIGHT-OF-WAY. | | PLEASE NOTE THAT ANY PLANTINGS SHALL NOT IMPEDE WITH | | THE SITE DISTANCE AND SHALL BE APPROVED BY FDOT. | | | | 6. ON SHEET C102, THERE ARE SIGNS SHOWN IN THE SOUTH | | DIXIE HIGHWAY PEDESTRIAN SIDEWALK. PLEASE CLARIFY. | | | | 7. IMPROVEMENTS WITHIN THE SOUTH DIXIE RIGHT-OF-WAY | | (INCLUDING NEW CURBING, BOLLARDS, LIGHTING, SIDEWALKS, | | ETC.) SHALL BE SUBJECT TO PERMITTING BY FDOT. | | MAINTENANCE AGREEMENTS MAY BE REQUIRED. | | | | 8. ALL IMPROVEMENTS WITHIN THE JEFFERSON ROAD, | | CRANESNEST WAY, AND SOUTH OLIVE AVENUE RIGHT-OF-WAY | | (I.E. ON-STREET PARKING, RESURFACING, ETC.) SHALL BE | | SUBJECT TO A CITY OF WPB RIGHT-OF-WAY PERMIT, OBTAINED | | FROM THE CITY'S ENGINEERING DEPARTMENT. | | | | 9. ALL LANDSCAPING SHALL BE SUBMITTED AND REVIEWED AS A | | SEPARATE PERMIT APPLICATION, SUBMITTED TO THE CITY?S | | BUILDING DIVISION. | | | | 10. ON SHEET L103, THE EXISTING EAST ENTRANCE HAS A | | LABEL INDICATING "EXISTING PATH TO BE REMOVED", BUT | | DOES NOT SHOW WHAT THE PROPOSED IMPROVEMENTS ARE. THE | | SITE PLAN SHOULD BE AN ACCURATE REFLECTION OF THE | | COMPLETED PROJECT. | | | | 11. ON SHEET L102 NOT ALL OF THE PARKING LOT STRIPING | | IS SHOWN. THIS SHALL BE PROVIDED TO ENSURE COMPLIANCE | | WITH THE NUMBER OF PARKING SPACES REQUIRED. | | | | 12. PHOTOMETRIC PLAN SHALL BE PROVIDED AND SHALL NOT | | EXCEED 1.0 FOOTCANDLES WHEN MEASURED AT THE PROPERTY | | LINE. | | | | 13. ALL SIGNAGE (WALL MOUNTED, FREESTANDING, ETC.) | | SHALL BE SUBMITTED AND REVIEWED UNDER SEPARATE PERMITS. | | | | 14. PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF | | OCCUPANCY: | | | | A. THE PROPERTY SHALL BE RE-PLATTED IN ACCORDANCE WITH | | ALL APPLICABLE STATUTES, REGULATIONS, AND THE CITY?S | | POLICIES AND PROCEDURES. | | | | B. JEFFERSON ROAD, BETWEEN SOUTH DIXIE HIGHWAY AND | | SOUTH OLIVE AVENUE SHALL BE MILLED AND RESURFACED. ALL | | APPLICABLE PERMITS SHALL BE OBTAINED FROM THE CITY?S | | PUBLIC WORKS DEPARTMENT. | | | | C. ANY DAMAGE TO EXISTING UTILITIES RESULTING FROM THE | | DEVELOPER'S CONSTRUCTION ACTIVITIES SHALL BE REPAIRED, | | AT THE DEVELOPER'S EXPENSE. | | | | | | 15. SHEET L103, L104 DOES NOT MATCH SHEET L101. | | | | 16. SHEET L003 (MASTER PLAN) DOES NOT MATCH THE MASTER | | PLAN APPROVED BY THE CITY COMMISSION. SITE IMPROVEMENTS | | (PARKING,ETC.) HAVE BEEN MODIFIED AND THE BOUNDARY | | IDENTIFYING THE HISTORIC PROPERTY HAS BEEN MOVED. | | | | 17. THE DATA TABLE ON SHEET L102 SHOWS SIGNIFICANT | | CHANGES FROM WHAT WAS APPROVED BY THE CITY COMMISSION. | | MODIFICATIONS SHALL BE APPROVED THROUGH A MINOR PD | | AMENDMENT, UNLESS TRIGGERING ONE OF THE PROVISIONS OF | | SEC. 94-207(E)(1) OF THE CITY'S ZONING AND LAND | | DEVELOPMENT REGULATIONS. ALSO, THERE ARE | | INCONSISTENCIES IN THE DATA TABLE, SUCH AS SQUARE | | FOOTAGE FOR THE MUSEUM. NOTE THAT AN INCREASE IN SQUARE | | FOOTAGE MAY NECESSITATE ADDITIONAL PARKING, ETC. | | | | 18. SHEET E200 DOES NOT MATCH SHEET L101. | | ___________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ___________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1448 | | F: 561.822.1460 | | | | E: [email protected] | | | | W: WPB.ORG | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2016-07-20 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2016-07-20 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2016-07-20 |
Time |
13:53 |
Sent To |
|
|
Notes |
2016-07-20 13:54:39 | ZONING PLAN REVIEW | | ___________________________________________ | | | | DATE OF REVIEW: 07.20.2016 | | PERMIT NO.: 16050912 | | ADDRESS: 1451 S OLIVE AVENUE | | CONTRACTOR/CONTACT: MICHAEL IZZO | | TELEPHONE NO.: | | SCOPE OF REVIEW: NORTON MUSEUM EXPANSION | | ___________________________________________ | | | | REVIEW STATUS: FAILED | | ___________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY EXISTING | | TREES, A TREE ALTERATION PERMIT SHALL BE OBTAINED FROM | | THE DEVELOPMENT SERVICES DEPARTMENT ? PLANNING | | DIVISION. | | | | 2. ANY REQUIRED EASEMENTS (I.E. DRAINAGE, UTILITIES, | | PUBLIC ACCESS, ETC.) SHALL BE PROVIDED VIA PLAT OR | | SEPARATE LEGAL INSTRUMENT. | | | | 3. ALL CHAINLINK FENCING SHALL BE COMPLETELY SCREENED | | FROM VIEW UTILIZING SHRUBS, HEDGING, OR OTHER | | ACCEPTABLE LANDSCAPE MATERIAL. | | | | 4. THE DEVELOPER SHALL BE RESPONSIBLE FOR THE | | INSTALLATION OF IRRIGATION AND LANDSCAPING WITHIN THE | | RIGHTS-OF-WAY ADJACENT TO THE CSPD, AND SHALL BE | | RESPONSIBLE FOR THE MAINTENANCE OF SUCH IMPROVEMENTS, | | IN PERPETUITY. | | | | 5. ALL UTILITY ELEMENTS (I.E. BACKFLOW PREVENTERS, | | ETC.) SHALL BE SCREENED WITH LANDSCAPING TO THE MAXIMUM | | EXTENT ALLOWED BY THE CONTROLLING UTILITY AGENCY. IT | | APPEARS THAT THERE ARE CONFLICTS BETWEEN SUCH UTILITY | | ELEMENTS AND FENCING, ETC. ALL CONFLICTS SHALL BE | | RESOLVED AND SUFFICIENT SCREENING PROVIDED. | | | | 6. A MINOR AMENDMENT SHALL BE SUBMITTED TO AND APPROVED | | BY THE DEVELOPMENT SERVICES DEPARTMENT ? PLANNING | | DIVISION PROVIDING DETAILED LANDSCAPE PLANS FOR | | CONSTRUCTION IMPLEMENTATION. SUCH PLANS SHALL: | | | | A. SPECIFY THE EXACT SPECIES AND LOCATION OF ALL | | TREES, SHRUBS, HEDGES, GROUNDCOVER, ETC. AND BE IN | | COMPLIANCE WITH ARTICLE XIV OF THE CITY?S ZONING AND | | LAND DEVELOPMENT REGULATIONS, EXCEPT FOR THOSE | | PREVIOUSLY WAIVERS GRANTED | | | | B. IDENTIFY THE LOCATION OF ALL TREES/PALMS THAT ARE | | TO BE RELOCATED ON-SITE; | | | | C. IDENTIFY THE LOCATIONS REQUIRED FOR ROOT BARRIERS; | | | | I. INCLUDE A SHRUB PLANTING PLAN FOR THE OFF-SITE | | PARKING LOT LOCATED ON THE WEST SIDE OF SOUTH DIXIE | | HIGHWAY; | | | | II. PROVIDE THE DETAILED LANDSCAPE IMPROVEMENTS | | PROPOSED WITHIN THE SOUTH DIXIE HIGHWAY RIGHT-OF-WAY. | | PLEASE NOTE THAT ANY PLANTINGS SHALL NOT IMPEDE WITH | | THE SITE DISTANCE AND SHALL BE APPROVED BY FDOT. | | | | 7. ALL OF THE LANDSCAPING ON THE APPROVED LANDSCAPE | | PLANS SHALL BE INSTALLED. PLEASE CLARIFY WHY | | SIGNIFICANT AMOUNTS OF THE PREVIOUSLY-APPROVED | | LANDSCAPE PLAN ARE BEING EXCLUDED. | | | | 8. A CONSTRUCTION SITE SECURITY AND MANAGEMENT PLAN | | SHALL BE REVIEWED AND APPROVED BY THE CITY OF WEST PALM | | BEACH POLICE DEPARTMENT ? CRIME PREVENTION UNIT. A COPY | | OF THE MANAGEMENT PLAN AND APPROVAL LETTER FROM THE | | CRIME PREVENTION UNIT SHALL BE PROVIDED TO THE | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION. | | | | 9. THE CITY OF WEST PALM BEACH POLICE DEPARTMENT ? | | CRIME PREVENTION UNIT SHALL REVIEW AND APPROVE ALL | | CONSTRUCTION DRAWINGS TO ENSURE THEY ADHERENCE TO | | GENERALLY-ACCEPTED CRIME PREVENTION THROUGH | | ENVIRONMENTAL DESIGN (CPTED) PRINCIPLES. A LETTER FROM | | THE CRIME PREVENTION UNIT INDICATING THAT SUCH PLANS | | HAVE BEEN REVIEWED AND APPROVED SHALL BE PROVIDED TO | | THE DEVELOPMENT SERVICES DEPARTMENT ? PLANNING | | DIVISION. | | | | 10. ON SHEET C102, PLEASE CLARIFY WHY THE NEW CURB ON | | SOUTH DIXIE HIGHWAY IS NOT IN LINE WITH THE EXISTING | | CURB LINE AT JEFFERSON ROAD AND CRANESNEST WAY. THIS | | DOES NOT MATCH WHAT IS SHOWN ON SHEET L101 AND THE | | APPROVED SITE PLAN. | | | | 11. ON SHEET C102, THERE ARE MULTIPLE SIGNS SHOWN IN | | THE SOUTH DIXIE HIGHWAY PEDESTRIAN SIDEWALK. PLEASE | | CLARIFY. | | | | 12. IMPROVEMENTS WITHIN THE SOUTH DIXIE RIGHT-OF-WAY | | (INCLUDING NEW CURBING, BOLLARDS, LIGHTING, SIDEWALKS, | | ETC.) SHALL BE SUBJECT TO PERMITTING BY FDOT. | | MAINTENANCE AGREEMENTS MAY BE REQUIRED. | | | | 13. ALL IMPROVEMENTS WITHIN THE JEFFERSON ROAD, | | CRANESNEST WAY, AND SOUTH OLIVE AVENUE RIGHT-OF-WAY | | (I.E. ON-STREET PARKING, RESURFACING, ETC.) SHALL BE | | SUBJECT TO A CITY OF WPB RIGHT-OF-WAY PERMIT, OBTAINED | | FROM THE CITY?S ENGINEERING DEPARTMENT. | | | | 14. ALL LANDSCAPING SHALL BE SUBMITTED AND REVIEWED AS | | A SEPARATE PERMIT APPLICATION, SUBMITTED TO THE CITY?S | | BUILDING DIVISION. | | | | 15. ON SHEET L101, REMOVE ALL LANDSCAPE MATERIAL FROM | | THE PLAN. | | | | 16. ON SHEET L101 THERE IS A LOT OF DEMARCATION AND | | MARKINGS THAT ARE NOT CLEARLY IDENTIFIED/LABELED, | | LABELS ARE IN THE WRONG LOCATION, DETAILS ARE NOT | | REFERENCED, ETC. | | | | 17. ON SHEET L101, THE EXISTING EAST ENTRANCE HAS A | | LABEL INDICATING ?EXISTING PATH TO BE REMOVED?, BUT | | DOES NOT SHOW WHAT THE PROPOSED IMPROVEMENTS ARE. THE | | SITE PLAN SHOULD BE AN ACCURATE REFLECTION OF THE | | COMPLETED PROJECT. | | | | 18. SITE DATA TABLE SHALL BE PROVIDED. THIS WAS ON | | SHEET L102 OF THE APPROVED SITE PLAN BUT IS NO LONGER | | SHOWN. | | | | 19. ON SHEET L102 NOT ALL OF THE PARKING LOT STRIPING | | IS SHOWN. THIS SHALL BE PROVIDED TO ENSURE COMPLIANCE | | WITH THE NUMBER OF PARKING SPACES REQUIRED. | | | | 20. PHOTOMETRIC PLAN SHALL BE PROVIDED AND SHALL NOT | | EXCEED 1.0 FOOTCANDLES WHEN MEASURED AT THE PROPERTY | | LINE. | | | | 21. PLEASE PROVIDE INFORMATION PERTAINING TO THE USE FO | | THE EXTERIOR IMAGE PROJECTOR. WHAT IS THE INTENDED USE? | | WHERE WILL IT BE PROJECTING TO? WHAT INFORMATION WILL | | BE PROJECTED? | | | | 22. ALL SIGNAGE (WALL MOUNTED, FREESTANDING, ETC.) | | SHALL BE SUBMITTED AND REVIEWED UNDER SEPARATE PERMITS. | | | | 23. PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF | | OCCUPANCY: | | | | A. THE PROPERTY SHALL BE RE-PLATTED IN ACCORDANCE WITH | | ALL APPLICABLE STATUTES, REGULATIONS, AND THE CITY?S | | POLICIES AND PROCEDURES. | | | | B. JEFFERSON ROAD, BETWEEN SOUTH DIXIE HIGHWAY AND | | SOUTH OLIVE AVENUE SHALL BE MILLED AND RESURFACED. ALL | | APPLICABLE PERMITS SHALL BE OBTAINED FROM THE CITY?S | | PUBLIC WORKS DEPARTMENT. | | | | C. ANY DAMAGE TO EXISTING UTILITIES RESULTING FROM THE | | DEVELOPER?S CONSTRUCTION ACTIVITIES SHALL BE REPAIRED, | | AT THE DEVELOPER?S EXPENSE. | | ___________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ___________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1448 | | F: 561.822.1460 | | | | E: [email protected] | | | | W: WPB.ORG | | |
|
|
|