Plan Review Details - Permit 16050764
Plan Review Stops For Permit 16050764 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2016-06-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-06-22 |
Time |
08:56 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-06-22 |
Time |
08:38 |
Sent To |
|
|
Notes |
2016-06-22 08:59:57 | 06/22/16 TALKED TO GARY HIGHT ABOUT ROOF VENTS PROVISO: | | | | APPROVED WITH PROVISO: | | | | 1- IF THERE ARE ROOF VENTS TO BE REPLACED, THEN PRODUCT | | APPROVAL IS REQUIRED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-05-24 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-05-24 |
Time |
17:13 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-05-24 |
Time |
17:02 |
Sent To |
|
|
Notes |
2016-05-24 17:27:06 | RESIDENTIAL (R3) FRONT BUILDING, RE-ROOF BUILDING | | REVIEW COMMENTS | | CODE: FBC 5TH EDITION (2014). | | | | 1- FLAT ROOF ASSEMBLY W-51 FROM FLORIDA PRODUCT | | APPROVAL FL2533-R15 DOESN'T MEET THE DESIGN PRESSURES | | FOR ROOF ZONE #3. THE DESIGN PRESSURES FOR SELECTED | | ASSEMBLY ARE -105.0 PSF. THIS PROPERTY SEEMS TO BE | | LOCATED IN EXPOSURE "D" AND THE DESIGN PRESSURES FOR | | ZONE #3 ARE HIGHER THAN -105.0 PSF. SEC. R301.2.1.4.3 | | FBC-RESIDENTIAL, 5TH EDITION (2014). NEED TO PROVIDE | | SIGNED AND SEALED RAS 117 CALCULATIONS TO MEET THE | | DESIGN PRESSURES FOR ZONE #3, SPECIFY ANOTHER ASSEMBLY | | THAT MEETS THE DESIGN PRESSURES FOR ZONE #3 OR PROVIDE | | ANOTHER PRODUCT APPROVAL WITH ASSEMBLY THAT MEETS THE | | DESIGN PRESSURES FOR ALL ROOF ZONES. NOTE: COORDINATE | | WITH ITEM #2 BELOW REGARDING FLORIDA PRODUCT APPROVAL | | SUBMITTED.. | | | | 2- PROVIDE CURRENT PRODUCT APPROVAL. FLORIDA PRODUCT | | APPROVAL FL2533-R15 SUBMITTED WAS REVISED WITH REVISION | | #16. PROVIDE 2 COPIES OF REVISED FL2533-R16. | | FAC 61G20-3.002(33). | | | | 3- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR THE | | GALVANIZED ROOF VENTS SPECIFIED ON THE PROPOSAL | | SUBMITTED. FAC 61G20-3.002(33). | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2016-05-24 |
|
|
Cont ID |
|
Sent By |
destabro |
Date |
2016-05-24 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
destabro |
Date |
2016-05-24 |
Time |
11:00 |
Sent To |
B |
|
Notes |
2016-05-24 11:13:46 | 5/24/16- PASSED HPD REVIEW, THIS PROPERTY CONTRIBUTES | | TO THE EL CID HISTORIC DISTRICT AND THE ROOF IS A | | REPLACEMENT IN-KIND. APPLICATION MAY BE MISSING PRODUCT | | APPROVALS? DLE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-06-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-06-22 |
Time |
09:00 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-06-21 |
Time |
15:10 |
Sent To |
|
|
Notes |
2016-06-21 15:10:28 | RESUB ROUTED TO JGOMEZ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-05-24 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-05-24 |
Time |
17:02 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-05-18 |
Time |
13:23 |
Sent To |
|
|
Notes |
2016-05-19 13:23:16 | ROUTED TO HISTORIC VIA ZONING INBOX |
|
|
|