Plan Review Details - Permit 16050632
Plan Review Stops For Permit 16050632 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2016-06-17 |
|
|
Cont ID |
|
Sent By |
|
Date |
2016-06-17 |
Time |
|
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-06-17 |
Time |
10:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-05-31 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-05-31 |
Time |
07:17 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-05-31 |
Time |
07:17 |
Sent To |
|
|
Notes |
2016-05-31 07:19:02 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR | | PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED ORIGINALS | | FS471, FAC61G15-23.002. CALCULATIONS PROVIDED ARE | | PHOTOCOPIES. | | | | 2. THE GENERATOR PERMIT DOCUMENTS HAVE NOT YET BEEN | | SUBMITTED. THIS IS A REMINDER THAT THE CONTRACTOR IS | | REQUIRED TO SUBMIT GENERATOR SPECIFICATIONS AND OTHER | | INFORMATION REQUIRED FOR APPLICATION 15110831 (WHICH | | WAS PREVIOUSLY ISSUED IN ERROR). THIS ACTION IS NOT | | REQUIRED FOR THIS DIESEL TANK PERMIT, AND WILL NOT | | DELAY ISSUANCE OF THIS PERMIT (16050632). | | | | | | | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2016-06-06 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-06-06 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-06-06 |
Time |
14:57 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2016-05-23 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-05-23 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-05-23 |
Time |
10:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
11:15 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2016-05-31 |
Time |
09:48 |
Sent To |
|
|
Notes |
2016-06-01 09:48:27 | RESUB ROUTED TO FIRE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-05-31 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-05-31 |
Time |
07:19 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-05-16 |
Time |
09:49 |
Sent To |
|
|
Notes |
2016-05-17 09:49:44 | ROUTED TO FIRE |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2016-06-17 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-06-17 |
Time |
10:34 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-06-17 |
Time |
10:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-05-24 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-05-24 |
Time |
14:58 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-05-24 |
Time |
14:58 |
Sent To |
|
|
Notes |
2016-05-24 15:05:02 | 1ST REVIEW: FBC 2014 MECHANICAL | | PERMIT #16050632 | | 5/24/16 | | | | 1) THE BUOYANCY CALCULATIONS AND THE EXCAVATION DESIGN | | CALCULATIONS MUST BEAR THE ORIGINAL SIGNATURES AND | | SEALS OF THE PROFESSIONAL ENGINEERS OF RECORD- REFER TO | | SECTION 61G15-23.002 FLORIDA ADMINISTRATIVE CODE. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
|