Plan Review Details - Permit 16050432
Plan Review Stops For Permit 16050432 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2016-05-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-05-13 |
Time |
18:49 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-05-13 |
Time |
18:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2016-05-25 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-05-25 |
Time |
18:55 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-05-25 |
Time |
18:55 |
Sent To |
|
|
Notes |
2016-05-25 18:56:04 | BOND POOL WATER |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-05-12 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-05-12 |
Time |
19:10 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-05-12 |
Time |
18:40 |
Sent To |
|
|
Notes |
2016-05-12 19:09:50 | REVIEW 2014 5TH FBC ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 516-805-6713 | | [email protected] | | | | | | - NEC 680.21(C) GFCI PROTECTION. OUTLETS SUPPLYING POOL | | PUMP MOTORS 15 OR 20 AMPERES, 125 VOLT OR 240 VOLT, | | SINGLE PHASE, WHETHER BY RECEPTACLE OR DIRECT | | CONNECTION, SHALL BE PROVIDED WITH GROUND-FAULT | | CIRCUIT-INTERRUPTER PROTECTION FOR PERSONNEL. | | | | - NEC 680.22 GFCI PROTECTION REQUIRED FOR POOL LIGHT | | CIRCUIT , AND POOL EQUIPMENT SUCH AS HEATERS, BLOWERS | | AND ETC. | | | | - PROVIDE POOL LIGHT SPECS TO VERIFY IF ITS A LISTED | | LOW-VOLTAGE LUMINAIRE NOT REQUIRING GROUNDING, | | OTHERWISE ALL POOL LIGHT ASSEMBLY . WET-NICHE AND | | DRY-NICHE SHALL BE CONNECTED TO AN INSULATED COPPER | | GROUNDING CONDUCTOR # 8 AWG. NEC 680.24 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2016-05-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-05-13 |
Time |
18:38 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-05-13 |
Time |
18:37 |
Sent To |
|
|
Notes |
2016-05-13 18:39:25 | NO GAS IS SHOWN ON THE PLANS. SEPARATE PERMIT, | | APPLICATION AND REVIEWS WILL BE REQUIRED. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-05-25 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-05-25 |
Time |
18:56 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-05-19 |
Time |
14:15 |
Sent To |
|
|
Notes |
2016-05-19 14:15:39 | RESUB ROUTED TO NJWIRA VIA ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-05-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-05-13 |
Time |
18:49 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-05-11 |
Time |
13:13 |
Sent To |
|
|
Notes |
2016-05-11 13:13:37 | ROUTED TO ZONING |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2016-05-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-05-13 |
Time |
18:49 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-05-13 |
Time |
18:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2016-05-24 |
|
|
Cont ID |
|
Sent By |
njwira |
Date |
2016-05-24 |
Time |
11:27 |
Rev Time |
0.00 |
Received By |
njwira |
Date |
2016-05-24 |
Time |
11:27 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2016-05-12 |
|
|
Cont ID |
|
Sent By |
njwira |
Date |
2016-05-12 |
Time |
13:14 |
Rev Time |
0.00 |
Received By |
njwira |
Date |
2016-05-12 |
Time |
10:58 |
Sent To |
|
|
Notes |
2016-05-12 10:59:22 | 5/12/16- FAILED- NEEDS TO PROVIDE LOCATION ON SURVEY OF | | WHERE THE POOL EQUIPMENT IS LOCATED. | | | | NATHAN WIRA | | [email protected] |
|
|
|