Plan Review Details - Permit 16041194
Plan Review Stops For Permit 16041194 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2016-05-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-05-12 |
Time |
08:29 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-05-12 |
Time |
08:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-05-04 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-05-04 |
Time |
12:28 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-05-04 |
Time |
12:28 |
Sent To |
|
|
Notes |
2016-05-04 12:28:53 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. REVISE THE FLOOR PLAN TO SHOW ROOM DESIGNATIONS. | | | | 2. FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN | | HEIGHT, NOTE EXISTING CONDITIONS (TYPE OF WINDOW) AND | | OPENING SIZE FOR BEDROOMS, FBC R310, FBC EB 704.1. THE | | CLEAR OPENING CANNOT BE REDUCED BY MORE THAN 5%. | | | | TO PROVIDE FURTHER CLARIFICATION REGARDING INFORMATION | | NEEDED FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN | | HEIGHT: | | | | STATE WHAT TYPE OF WINDOW IS THERE NOW IN THE BEDROOMS | | - AWNING, CASEMENT, SINGLE HUNG? | | | | STATE WHAT THE EXISTING CLEAR OPENING DIMENSIONS ARE. | | CLEAR OPENING IS THE OPENING WHICH EXISTS WHEN THE | | WINDOW IS FULLY OPEN. | | | | STATE WHAT THE PROPOSED CLEAR OPENING DIMENSIONS ARE. | | THIS CAN BE OBTAINED FROM THE MANUFACTURER. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-05-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-05-12 |
Time |
08:29 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-05-05 |
Time |
13:05 |
Sent To |
|
|
Notes |
2016-05-05 13:05:41 | SHILL'S DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-05-04 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-05-04 |
Time |
12:28 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-04-27 |
Time |
15:00 |
Sent To |
|
|
Notes |
2016-04-27 15:00:56 | BLDG MISC 1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy