Plan Review Stops For Permit 16041147 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2016-12-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-12-30 |
Time |
|
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-12-30 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2016-11-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-11-17 |
Time |
17:01 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-11-17 |
Time |
17:01 |
Sent To |
|
|
Notes |
2016-11-17 17:05:11 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 16041147 | | ADD: 914 3RD ST. | | CONT: TREND WEST INC. | | TEL: 561-358-8817 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 4TH REVIEW | | DATE: MON. OCT. 24 /2016 | | ACTION: DENIED | | | | 1) SHEET S1: | | | | 1A)4TH REQUEST. THIS SHEET AND THE ELECTRICAL SHEETS | | SHOW 5 DWELLING UNITS, BUT THE DESIGNER OF RECORD MAKE | | NUMEROUS MENTION TO THE2014 RESIDENTIAL CODE. PLEASE | | NOTE THE FBC- RESIDENTIAL CODE IS FOR 1 & 2 FAMILY | | ONLY!!!!! PLEASE NOTE THIS 5 UNIT RESIDENTIAL STRUCTURE | | IS COVERED AND TO BE REVIEWED UNDER THE 2014 | | FBC-BUILDING CODE- BUILDING CODE. PLEASE CORRECT THE | | CODE REFERENCES TO THE RESIDENTIAL CODE AND TABLES IN | | THE RESIDENTIAL CODE. | | 2) 2014 FLORIDA BUILDING CODE- BUILDING, PLEASE PROVIDE | | THE WIND DESIGN CRITERIA UNDER 2014 FBC-B 1603.1.4 WIND | | DESIGN DATA. | | WIND DESIGN INCLUDES REFERENCES TO THE RESIDENTIAL | | CODE. SEE OTHER COMMENTS. REVISE. PLANS MAY BE SENT TO | | FBPE. HAVE ENGINEER ACKNOWLEDGE IN THE FORM OF A | | RESPONSE LETTER. | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2016-10-24 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-10-24 |
Time |
17:28 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-10-24 |
Time |
16:40 |
Sent To |
|
|
Notes |
2016-10-24 17:16:22 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 16041147 | | ADD: 914 3RD ST. | | CONT: TREND WEST INC. | | TEL: 561-358-8817 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 3RD REVIEW | | DATE: MON. OCT. 24 /2016 | | ACTION: DENIED | | | | 1) SHEET S1: | | | | 1A)3RD REQUEST. THIS SHEET AND THE ELECTRICAL SHEETS | | SHOW 5 DWELLING UNITS, BUT THE DESIGNER OF RECORD MAKE | | NUMEROUS MENTION TO THE2014 RESIDENTIAL CODE. PLEASE | | NOTE THE FBC- RESIDENTIAL CODE IS FOR 1 & 2 FAMILY | | ONLY!!!!! PLEASE NOTE THIS 5 UNIT RESIDENTIAL STRUCTURE | | IS COVERED AND TO BE REVIEWED UNDER THE 2014 | | FBC-BUILDING CODE- BUILDING CODE. PLEASE CORRECT THE | | CODE REFERENCES TO THE RESIDENTIAL CODE AND TABLES IN | | THE RESIDENTIAL CODE. | | | | 2) 2014 FLORIDA BUILDING CODE- BUILDING, PLEASE PROVIDE | | THE WIND DESIGN CRITERIA UNDER 2014 FBC-B 1603.1.4 WIND | | DESIGN DATA. | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | STRUCTURE: | | | | 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, | | VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | 1609.3.1. | | | | 2. RISK CATEGORY. | | | | 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7.2. | | HEIGHT AND EXPOSURE. | | | | 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | | 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/ | | M2). | | | | TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & | | EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE | | BUILDING. | | | | 1609.3.1 WIND SPEED CONVERSION VULT TO VASD. | | | | 3) THE SUBMITTED PRODUCT APPROVAL (FL 12769 JELD WEN) | | WITHOUT SURFACE BOLTS IS GOOD FOR -50 PSF, THE DESIGNER | | OF RECORD INDICATES THE NEGATIVE PRESSURES FOR THIS | | OPENING ARE -52.7 FOR DOORS LOCATED IN A INTERIOR ZONE | | # 4. THE DESIGNER OF RECORD CAN BE MORE RESTRICTIVE | | THAN THE MINIMUM CODE. PRESSURES GIVEN ARE AT 132 VASD. | | | | 4) THE DESIGNER OF RECORD HAS NOT APPLIED THEIR SHOP | | DRAWING STAMP OF APPROVAL ON THE PRODUCT APPROVAL | | SUBMITTED. FBC 107.3.4.1 PRODUCT APPROVALS. THOSE | | PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03 | | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2016-07-21 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-07-21 |
Time |
13:50 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-07-21 |
Time |
09:44 |
Sent To |
|
|
Notes |
2016-07-21 13:50:38 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 16041147 | | ADD: 914 3RD ST. | | CONT: TREND WEST INC. | | TEL: 561-358-8817 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE: THURS. JULY 21 /16 | | ACTION: DENIED | | | | 1) SHEET S1: | | | | 1A) 2ND REQUEST. THIS SHEET AND THE ELECTRICAL SHEETS | | SHOW 5 DWELLING UNITS, BUT THE DESIGNER OF RECORD MAKE | | NUMEROUS MENTION TO THE2014 RESIDENTIAL CODE. PLEASE | | NOTE THE FBC- RESIDENTIAL CODE IS FOR 1 & 2 FAMILY | | ONLY!!!!! PLEASE NOTE THIS 5 UNIT RESIDENTIAL STRUCTURE | | IS COVERED AND TO BE REVIEWED UNDER THE 2014 | | FBC-BUILDING CODE- BUILDING CODE. PLEASE CORRECT THE | | CODE REFERENCES TO THE RESIDENTIAL CODE. | | | | 1B) 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. THE | | EXAMINATION OF THE DOCUMENTS BY THE BUILDING OFFICIAL | | SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA AND | | DOCUMENTS: A FLOOR PLAN MISSING FROM THE 2ND REVIEW. | | | | 107.3.5..11 COMMERCIAL BUILDINGS: | | FLOOR PLAN | | | | PLEASE PROVIDE UNDER THE R2 OCCUPANCY WHICH OF THE USES | | BELOW: | | APARTMENTS | | BOARDING HOUSES (NONTRANSIENT) WITH MORE THAN 16 | | OCCUPANTS | | CONGREGATE LIVING FACILITIES (NONTRANSIENT) WITH MORE | | THAN 16 OCCUPANTS | | HOTELS (NONTRANSIENT) | | | | 1C) THERE IS A DISCREPANCY IN THE SCOPE OF WORK BETWEEN | | THE PERMIT APPLICATION AND THE SHEET S1. SHEET S1 DOES | | NOT LIST THE REPLACEMENT OF ANY WINDOWS, WHERE AS THE | | PERMIT APPLICATION DOES INDICATE NEW WINDOWS. NO | | PRODUCT APPROVALS FOR WINDOWS HAVE BEEN SUBMITTED TO | | DATE. | | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. / 2014 | | FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.4.1 | | COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY | | AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF | | PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE | | PRODUCT APPROVALS: | | (31)(B) WINDOWS | | | | 1D) UNDER COMMENT 1B, THE REQUESTED FLOOR PLAN IS FOR | | THE REPLACEMENT OF WINDOWS, SHOW SIZES OF WINDOWS FOR | | ALL ROOMS, USE OF ROOMS, THE EXISITNG WINDOW AND THE | | TYPE OF PROPOSED WINDOW. PLEASE SHOW COMPLIANCE WITH: | | 2014 FBC-B: | | | | 1D)(1) 1029.2 MINIMUM SIZE. EMERGENCY ESCAPE AND RESCUE | | OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7 | | SQUARE FEET (0.53 M2). | | EXCEPTION: THE MINIMUM NET CLEAR OPENING FOR GRADEFLOOR | | EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE 5 SQUARE | | FEET (0.46 M2). | | | | 1D)(2) 1029.2.1 MINIMUM DIMENSIONS. THE MINIMUM NET | | CLEAR OPENING HEIGHT DIMENSION SHALL BE 24 INCHES (610 | | MM). THE MINIMUM NET CLEAR OPENING WIDTH DIMENSION | | SHALL BE 20 INCHES (508 MM). THE NET CLEAR OPENING | | DIMENSIONS SHALL BE THE RESULT OF NORMAL OPERATION OF | | THE OPENING. | | | | 1D)(3) 1029.3 MAXIMUM HEIGHT FROM FLOOR. EMERGENCY | | ESCAPE AND RESCUE OPENINGS SHALL HAVE THE BOTTOM OF THE | | CLEAR OPENING NOT GREATER THAN 44 INCHES (1118 MM) | | MEASURED FROM THE FLOOR. | | | | | | 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | THIS REVIEW. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-05-13 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-05-13 |
Time |
07:30 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-05-13 |
Time |
06:48 |
Sent To |
|
|
Notes |
2016-05-13 07:33:38 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 16041147 | | ADD: 914 3RD ST. | | CONT: TREND WEST INC. | | TEL: 561-358-8817 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: FRI. MAY 13/16 | | ACTION: DENIED | | | | 1) SHEET S1: | | | | 1A) THIS SHEET AND THE ELECTRICAL SHEETS SHOW 5 | | DWELLING UNITS, BUT THE DESIGNER OF RECORD MAKE | | NUMEROUS MENTION TO THE SINGLE FAMILY CODE. PLEASE NOTE | | THIS 5 UNIT RESIDENTIAL STRUCTURE IS COVERED AND TO BE | | REVIEWED UNDER THE 2014 FBC-BUILDING CODE. PLEASE | | CORRECT THE CODE REFERENCES TO THE RESIDENTIAL CODE. | | | | 1B) 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. THE | | EXAMINATION OF THE DOCUMENTS BY THE BUILDING OFFICIAL | | SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA AND | | DOCUMENTS: A FLOOR PLAN | | 107.3.5..11 COMMERCIAL BUILDINGS: | | FLOOR PLAN | | OCCUPANCY GROUP AND SPECIAL OCCUPANCY REQUIREMENTS | | SHALL BE DETERMINED. R1, R2 OR R4 USAGE: | | R2: | | BOARDING HOUSES (NONTRANSIENT) WITH MORE THAN 16 | | OCCUPANTS | | CONGREGATE LIVING FACILITIES (NONTRANSIENT) WITH MORE | | THAN 16 OCCUPANTS | | HOTELS (NONTRANSIENT) | | R4: | | ALCOHOL AND DRUG CENTERS | | ASSISTED LIVING FACILITIES | | CONGREGATE CARE FACILITIES | | CONVALESCENT FACILITIES | | GROUP HOMES | | HALFWAY HOUSES | | RESIDENTIAL BOARD AND CUSTODIAL CARE FACILITIES | | SOCIAL REHABILITATION FACILITIES | | GROUP R-4 OCCUPANCIES SHALL MEET THE REQUIREMENTS FOR | | CONSTRUCTION AS DEFINED FOR GROUP R-3, EXCEPT AS | | OTHERWISE PROVIDED FOR IN THIS CODE., | | MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED (SEE | | TABLE 503). | | FIRE-RESISTANT CONSTRUCTION REQUIREMENTS SHALL INCLUDE | | THE FOLLOWING COMPONENTS: | | FIRE-RESISTANT SEPARATIONS | | FIRE-RESISTANT PROTECTION FOR TYPE OF CONSTRUCTION | | PROTECTION OF OPENINGS AND PENETRATIONS OF RATED WALLS | | OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: | | OCCUPANCY LOAD | | GROSS | | NET | | MEANS OF EGRESS | | DEPENDING ON THE USAGE: | | ACCESSIBILITY REQUIREMENTS SHALL INCLUDE THE FOLLOWING: | | SITE REQUIREMENTS | | ACCESSIBLE ROUTE | | VERTICAL ACCESSIBILITY | | TOILET AND BATHING FACILITIES | | DRINKING FOUNTAINS | | | | 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | THIS REVIEW. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2017-02-15 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2017-02-15 |
Time |
09:49 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2017-02-15 |
Time |
09:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2016-10-03 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-10-03 |
Time |
16:04 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-10-03 |
Time |
15:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2016-07-18 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-07-18 |
Time |
15:14 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-07-18 |
Time |
13:10 |
Sent To |
|
|
Notes |
2016-07-18 15:17:44 | JOB PERMIT NUMBER: 729 PENN ST | | JOB ADDRESS: 471 SPENCER DRIVE | | WEST PALM BEACH FLORIDA | | DATE: JULY 18 2016 | | ELECTRICAL PLAN REVIEW COMMENTS | | THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION | | HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF | | THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC, | | (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST | | PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF | | SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED. | | | | - SHOW LOCATION OF EXISTING SUB PANEL "A" ON THE FLOOR | | PLAN TO VERIFY WORK CLEARANCES, LOAD CALCULATIONS AND | | PANEL SCHEDULE REFLECT A RANGE BUT HOWEVER ON THE | | KITCHEN LAYOUT THERE IS A COOKTOP AND AN OVEN ? MODIFY | | ACCORDINGLY. FBC 107 MINIMUM PLAN REVIEW CRITERIA. | | - KITCHEN ISLAND RECEPTACLE OUTLETS ON BOTH ENDS SHALL | | BE GFCI PROTECTED AND INSTALLED NO MORE THAN 12'' BELOW | | THE COUNTERTOP. FBC R SECTIONS E3902.6 & E3901.4.2 | | - A/C DISCONNECT SEEMS TO BE BEHIND THE COMPRESSOR, | | PLEASE REFLECT PROPER WORK CLEARANCE. OUTSIDE GFCI | | RECEPTACLE SHALL ?WR? IN ADDITION OF BEING INSTALLED IN | | A ?WP? ENCLOSURE. FBC R SECTIONS E4002.9 & E3405.1 | | - NFPA SECTION 29.8.3.4(6). SMOKE ALARMS AND SMOKE | | DETECTORS SHALL NOT BE INSTALLED WITHIN A 36 IN. (910 | | MM) HORIZONTAL PATH FROM A DOOR TO A BATHROOM | | CONTAINING A SHOWER OR TUB UNLESS LISTED FOR | | INSTALLATION IN CLOSE PROXIMITY TO SUCH LOCATIONS. | | RELOCATE THE UNITS ACCORDINGLY. | | - ONE AND TWO FAMILY DWELLINGS SHALL HAVE OUTDOOR | | RECEPTACLES IN BOTH BACK & FRONT OF THE HOUSE. FBC R | | E3901.7 | | - FBC-E R404.1 A MINIMUM OF 75 PERCENT OF THE LAMPS IN | | PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE | | HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF THE | | PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CONTAIN | | ONLY HIGH EFFICACY LAMPS. | | - PROVIDE AN ATTIC ENTRANCE LIGHT THAT IS SWITCHED AS | | REQUIRED AND ILLUMINATION SHALL BE SUFFICIENT FOR | | SERVICING THE AIR HANDLING UNIT. FBC R SECTION E3903.4 | | | | PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE | | MENTIONED DEFICIENCIES. | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE | | LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE | | STANDARD CITY RE-SUBMITTAL FORM. THE NARRATIVE SHOULD | | INCLUDE THE PLAN REVIEWER'S COMMENTS AND YOUR RESPONSE | | OR ACTION TO SAME. | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO THE | | SUBMITTAL AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | COMPARISON. CLOUDING THE CHANGES WILL BE GREATLY | | APPRECIATED. | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON'T HESITATE TO | | CONTACT ME DIRECTLY. | | | | FBC 2014 5TH ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-04-28 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-04-28 |
Time |
19:09 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-04-28 |
Time |
19:09 |
Sent To |
|
|
Notes |
2016-04-28 19:35:54 | JOB PERMIT NUMBER: 16041147 | | JOB ADDRESS: 914 3RD ST 1 | | WEST PALM BEACH FLORIDA | | DATE: APRIL 28 2016 | | ELECTRICAL PLAN REVIEW COMMENTS | | THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION | | HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF | | THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC, | | (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST | | PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF | | SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED. | | | | - ELECTRICAL SERVICE RISER SHOWS 2? CONDUIT WITH 2 SETS | | OF 3/0 AWG IN PARALLEL , HOWEVER TABLE ANNEX C CONDUIT | | FILL STATES ONLY 5 WIRES FIT ASSUMING EITHER IMC OR RMC | | IS BEING INSTALLED. CLARIFY AND CORRECT ACCORDINGLY ? | | - PROVIDE INTERSYSTEM BONDING TERMINAL STRIP ON THE | | GROUNDING DETAIL IN THE RISER DIAGRAM. NEC 250.94 | | - ELECTRICAL NOTE OF LIGHTING NEEDING TO BE 50 % HIGH | | EFFICIENT IS INCORRECT FBC-E R 404.1 A MINIMUM 75 % | | LAMPS SHALL BE HIGH EFFICACY , FURTHER MORE CHANGE THE | | CODE REFERENCE OF NEC 2008 TO THE APPLICABLE 2011 IN | | TAMPER RESISTANT RECEPTACLE NOTE. | | - SERVICE EQUIPMENT TO INCLUDE ALL PERMANENT PLAQUES OF | | NEC 225.37 , INTERIOR PANELBOARDS TO HAVE | | IDENTIFICATION OF SOURCE OF SUPPLY IN ACCORDANCE WITH | | NEC 408.4 (B) | | - FOR FINAL INSPECTION ARC-FLASH HAZARD WARNING LABELS | | AND AVAILABLE FAULT CURRENT MARKINGS MUST BE ON | | ELECTRICAL APPARATUS SUITABLE TO WITHSTAND ENVIRONMENT. | | - ALL ELECTRICAL BOXES IN A DEMISING WALL SHALL COMPLY | | WITH NEC 300.21 AND FBC SECTION 714. ANY FIRE RATED | | STRUCTURE THAT IS COMPROMISED SHALL BE RETURNED TO ITS | | ORIGINAL FIRE-RATING WITH APPROVED FIRE SEALING | | MATERIAL. | | - PROVIDE SPECS ON A/C WALL UNITS TO VERIFY IF THEY | | PROVIDE HEAT PER FBC-R 303.9 EVERY DWELLING UNIT | | HABITABLE ROOM SHALL BE CAPABLE OF MAINTAINING 68 | | DEGREES FAHRENHEIT AT 3 FT ABOVE FLOOR AND 2 FT FROM | | EXTERIOR WALLS. | | | | PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE | | MENTIONED DEFICIENCIES. | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE | | LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE | | STANDARD CITY RE-SUBMITTAL FORM. THE NARRATIVE SHOULD | | INCLUDE THE PLAN REVIEWER?S COMMENTS AND YOUR RESPONSE | | OR ACTION TO SAME. ADDITIONALLY, PLEASE INSERT | | CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE | | PREVIOUSLY REVIEWED SHEETS FOR COMPARISON. | | CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED. | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | | | FBC 2014 5TH ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 516-805-6713 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2017-02-15 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-02-15 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-02-14 |
Time |
09:37 |
Sent To |
|
|
Notes |
2017-02-15 09:38:09 | RESUB ROUTED TO VPEREZ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2017-01-24 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-01-24 |
Time |
15:28 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-01-17 |
Time |
15:16 |
Sent To |
|
|
Notes |
2017-01-18 15:16:59 | RESUB ROUTED TO CCOLE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2017-01-12 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-01-12 |
Time |
16:25 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-12-22 |
Time |
16:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2016-11-30 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2016-11-30 |
Time |
14:08 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2016-11-04 |
Time |
16:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-10-24 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-10-24 |
Time |
17:28 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-09-29 |
Time |
11:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-07-30 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-07-30 |
Time |
02:00 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-07-01 |
Time |
12:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-05-16 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-05-16 |
Time |
13:50 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-04-26 |
Time |
15:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
7 |
Status |
P |
Date |
2017-02-15 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-02-15 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-02-15 |
Time |
15:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
6 |
Status |
F |
Date |
2017-01-24 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-01-24 |
Time |
15:28 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-01-24 |
Time |
15:28 |
Sent To |
|
|
Notes |
2017-01-24 15:36:48 | 6TH REVIEW FBC-2014 MECHANICAL | | PERMIT #16041147 | | 1/24/17 | | | | 1) THE ELECTRICAL PLANS AND THE REVISED AC AND ENERGY | | CALCULATIONS DO NOT MATCH. THE PLANS INDICATE 5 WALL | | SYSTEMS LOCATED IN THE LIVING ROOMS OF UNITS 1-5. THE | | REVISED CALCULATIONS ARE FOR 15 WALL SYSTEMS TO BE | | LOCATED APPARENTLY IN THE LIVING ROOMS AND BEDROOMS OF | | THE UNITS. PLEASE NOTE THAT THE PANEL SCHEDULES ARE | | INDICATING ONLY FIVE WALL SYSTEMS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
F |
Date |
2016-12-29 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-12-29 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-12-29 |
Time |
08:59 |
Sent To |
|
|
Notes |
2016-12-29 09:54:44 | 5TH REVIEW FBC-2014 MECHANICAL | | PERMIT #16041147 | | 12/28/16 | | | | 1) THE REVISED AC CALCULATIONS BY KO ENERGY DESIGN | | APPEAR TO BE FOR ONE SINGLE 2-BEDROOM RESIDENCE, AND | | INCLUDE TOTAL COOLING AND HEATING LOADS, AND "DUCT | | SIZING". THE PLANS BY BUCHANAN P.E. CONSULTING INC. ARE | | SHOWING 5 "DUCTLESS" THROUGH THE WALL AC UNITS SERVING | | ONLY THE LIVING ROOMS AND KITCHENS AND NO BEDROOMS OF 5 | | DIFFERENT APARTMENTS. AS NOTED IN PREVIOUS REVIEWS, | | THESE CONFLICTS NEED TO BE CORRECTED. PLEASE NOTE | | MINIMUM HEATING IS REQUIRED FOR ALL OCCUPIED SPACES PER | | SECTION 309.1. | | | | 2) PROVIDE AN AC EQUIPMENT SCHEDULE ON THE PLAN TO | | MATCH THE SYSTEM DATA IN THE CALCULATIONS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
F |
Date |
2016-11-10 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-11-10 |
Time |
10:30 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-11-10 |
Time |
10:30 |
Sent To |
|
|
Notes |
2016-11-10 11:12:26 | 4TH REVIEW FBC-2014 MECHANICAL | | PERMIT #16041147 | | 11/10/16 | | | | 1) AS PREVIOUSLY REQUESTED, THE OWNER'S SIGNATURE IS | | REQUIRED TO BE ON THE ENERGY FORMS, AND THE MAKE AND | | MODEL NUMBERS OF THE AC SYSTEMS SHALL BE ON THE PLANS. | | | | 2) THE AC CALCULATIONS DO NOT APPEAR TO BE FOR THE | | PROPOSED PROJECT BECAUSE THEY ARE LISTING THE PROJECT | | TITLE AS "MONTOYA RESIDENCE" WITH A STUART ADDRESS, AND | | THE CALCULATIONS ARE FOR ONLY 3 SYSTEMS. THE PROJECT | | UNDER REVIEW HAS 5 SYSTEMS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2016-10-11 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-10-11 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-10-11 |
Time |
10:27 |
Sent To |
|
|
Notes |
2016-10-11 10:40:03 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #16041147 | | 10/11/16 | | | | 1) THE ENERGY CONSERVATION FORM R402-2014 MUST BE | | SIGNED BY THE PERSON WHO PREPARED THE DOCUMENT AND BY | | THE OWNER/AGENT. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2016-07-20 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-07-20 |
Time |
10:43 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-07-20 |
Time |
10:22 |
Sent To |
|
|
Notes |
2016-07-20 11:03:45 | 2ND REVIEW MECHANICAL | | PERMIT #16041147 | | 7/20/16 | | | | 1) THE COMMENTS FROM THE 1ST REVIEW STILL EXIST. I HAVE | | REPRINTED THEM BELOW. PLEASE NOTE THAT MINIMUM HEATING | | IS REQUIRED FOR ALL OCCUPIABLE SPACES PER SECTION | | 309.1. THE PLANS DO NOT INDICATE COMPLIANCE. | | | | 1ST REVIEW: FBC 2014 MECHANICAL | | PERMIT #16041147 | | 4/29/16 | | | | 1) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE | | NEW AC SYSTEMS IN THE LIVING ROOMS- REFER TO SECTION | | C403.2.1 FBC ENERGY CONSERVATION. | | 2) PROVIDE EQUIPMENT SCHEDULES ON THE PLANS FOR THE NEW | | AC SYSTEMS, INSTALLATION DETAILS, AND SUBMIT | | MANUFACTURER'S SPECIFICATIONS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-05-16 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-04-29 |
Time |
13:50 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-04-29 |
Time |
10:46 |
Sent To |
|
|
Notes |
2016-04-29 10:48:39 | 1ST REVIEW: FBC 2014 MECHANICAL | | PERMIT #16041147 | | 4/29/16 | | | | 1) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE | | NEW AC SYSTEMS IN THE LIVING ROOMS- REFER TO SECTION | | C403.2.1 FBC ENERGY CONSERVATION. | | 2) PROVIDE EQUIPMENT SCHEDULES ON THE PLANS FOR THE NEW | | AC SYSTEMS, INSTALLATION DETAILS, AND SUBMIT | | MANUFACTURER'S SPECIFICATIONS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2017-01-12 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-01-12 |
Time |
16:25 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-01-12 |
Time |
16:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2016-11-28 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-11-28 |
Time |
12:15 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-11-28 |
Time |
12:08 |
Sent To |
|
|
Notes |
2016-11-28 12:18:53 | 1ST REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | 1. PROVIDE SCOPE OF WORK FOR PLUMBING. PER WPB AMEND TO | | FBC 107.2.1 | | | | 2. ADDRESS COMMENTS FROM MECHANICAL AND BUILDING. PER | | WPB AMEND TO FBC 107.2.1 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2016-10-24 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-10-24 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-10-24 |
Time |
13:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2016-07-30 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-07-30 |
Time |
02:00 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-07-30 |
Time |
01:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2016-05-16 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-05-16 |
Time |
13:36 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-05-16 |
Time |
13:36 |
Sent To |
|
|
Notes |
2016-05-16 13:43:48 | 1ST REVIEW: FBC 2014 | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | 1. SHT. E-1 NOTE ON THE PLAN INDICATES WATER HEATERS AS | | NEW PLEASE CLARIFY PROVIDE A DETAILED SCOPE OF ANY | | PLUMBING WORK BEING DONE. PER WPB AMEND. TO FBC | | SEC.107.2.1 | | | | DO TO PLANS BEING INCOMPLETE OR UNCLEAR, A | | COMPREHENSIVE PLAN REVIEW CANNOT BE DONE AT THIS TIME, | | THERE MAYBE ADDITIONAL COMMENTS ON RESUBMITTAL OF | | PLANS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE | | PREVIOUSLY REVIEWED SHEETS. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2016-11-29 |
|
|
Cont ID |
|
Sent By |
|
Date |
2016-11-29 |
Time |
|
Rev Time |
0.00 |
Received By |
kmartin |
Date |
2016-11-29 |
Time |
16:53 |
Sent To |
|
|
Notes |
2016-11-28 14:29:53 | ROUTED TO KEVIN MARTIN |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2016-10-20 |
|
|
Cont ID |
|
Sent By |
|
Date |
2016-10-20 |
Time |
|
Rev Time |
0.00 |
Received By |
kmartin |
Date |
2016-10-20 |
Time |
16:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2016-07-29 |
Time |
|
Rev Time |
0.00 |
Received By |
kmartin |
Date |
2016-07-29 |
Time |
08:30 |
Sent To |
|
|
Notes |
2016-07-29 08:32:55 | 1. AC SCREENING DETAILS NEEDED. | | | | FOR MORE INFORMATION PLEASE CONTACT KEVIN MARTIN, URBAN | | DESIGN PLANNER AT (561) 822-1426 OR [email protected]. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
kmartin |
Date |
2016-05-16 |
Time |
|
Rev Time |
0.00 |
Received By |
kmartin |
Date |
2016-05-16 |
Time |
08:25 |
Sent To |
|
|
Notes |
|
|