Plan Review Details - Permit 16041095
Plan Review Stops For Permit 16041095
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-07-11 Cont ID  
Sent By aclange Date 2016-07-11 Time 16:29 Rev Time 0.00
Received By aclange Date 2016-07-11 Time 16:29 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-05-17 Cont ID  
Sent By aclange Date 2016-05-17 Time 16:55 Rev Time 0.00
Received By aclange Date 2016-05-17 Time 16:55 Sent To  
Notes
2016-05-17 16:56:28****CORRECTIONS****
  
 ART LANGE - BUILDING INSPECTOR
 561-805-6667 [email protected]
 FBC FLORIDA BUILDING CODE 2014 5TH EDITION/ FRC FLORIDA
 RESIDENTIAL CODE 2015 5TH EDITION
  
 1. FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND
 ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF
 THE PERSON RESPONSIBLE FOR THE DESIGN.
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS
 SHALL BE SUBMITTED WHEN APPROVED BY THE BUILDING
 OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT
 CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF
 THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT
 LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED
 BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND
 SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM
 OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS,
 WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE
 TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC,
 AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE
 OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5).
  
 2. PLEASE SUBMIT 2 SETS OF PLANS AND INCLUDE THE WIND
 DESIGN CRITERIA AND HOW THE PANELS WILL COMPLY WITH
 R301.1. PROVIDE ENGINEERING INCLUDING ANCHORING METHOD
 AND HOW IT WILL COMPLY WITH DEAD LOADS AND THE BASIC
 WIND SPEEDS OF 170 MPH 3 SECOND GUST. R301.4 DEAD
 LOADS, R301.1.3 ENGINEERING, R301.2.1.1 WIND DESIGN
 CRITERIA.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-07-11 Cont ID  
Sent By mvaldes Date 2016-07-11 Time 14:48 Rev Time 0.00
Received By mvaldes Date 2016-07-11 Time 14:33 Sent To  
Notes
2016-07-11 14:49:44REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
  
 - RED LINED IN WIRE AND BREAKER SIZES ACCORDING TO
 PHONE CONVERSATION WITH PROPERTY OWNER CARLOS JEAN.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-04-25 Cont ID  
Sent By mvaldes Date 2016-04-25 Time 19:02 Rev Time 0.00
Received By mvaldes Date 2016-04-25 Time 18:11 Sent To  
Notes
2016-04-25 19:04:52JOB PERMIT NUMBER: 16041095
 JOB ADDRESS: 119 N CHILLINGWORTH
 WEST PALM BEACH FLORIDA 33409
 DATE: APRIL 25 2016
  ELECTRICAL PLAN REVIEW COMMENTS
  
 THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION
 HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF
 THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC,
 (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST
 PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF
 SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED.
  
 - 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 ELECTRONIC MEDIA DOCUMENTS SHALL BE
 SUBMITTED WHEN APPROVED BY THE BUILDING OFFICIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES
 SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE
 TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE
 FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE
 DESIGN. (SEE ALSO SECTION 107.3.5).
  
 - FBC 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING
 PLANS SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON
 SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM.
 THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE,
 SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO
 RECORDS MANAGEMENT.
 - PROVIDE A SITE SPECIFIC PLAN SHOWING ELECTRICAL AND
 SOLAR EQUIPMENT AS IT RELATES TO EACH OTHER. THE FLOOR
 PLAN TO INCLUDE THE ROUTING OF SERVICE CONDUCTORS FROM
 UTILITY AND THE POINT OF CONNECTION OF THE INTERACTIVE
 GRID TIED SOLAR SYSTEM.
 - NEC 690 SHOW LABEL REQUIREMENTS OF GFP MARKINGS ON
 INVERTERS , DC / AC DISCONNECTING MEANS, INVERTER UL
 LISTING # REQUIRED , NEC 705 FEEDER CONDUCTOR AND
 PANELBOARD BUS AMPERE RATING CALCULATION ( 120 % ) ,
 NEC 240.21 TAP RULES MUST BE TAKEN INTO CONSIDERATION.
  
 PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE
 MENTIONED DEFICIENCIES.
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE
 LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE
 STANDARD CITY RE-SUBMITTAL FORM. THE NARRATIVE SHOULD
 INCLUDE THE PLAN REVIEWER?S COMMENTS AND YOUR RESPONSE
 OR ACTION TO SAME. ADDITIONALLY, PLEASE INSERT
 CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE
 PREVIOUSLY REVIEWED SHEETS FOR COMPARISON.
 CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 FBC 2014 5TH ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 516-805-6713
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-07-11 Cont ID  
Sent By aclange Date 2016-07-11 Time 16:29 Rev Time 0.00
Received By aclange Date 2016-07-07 Time 14:43 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-05-17 Cont ID  
Sent By aclange Date 2016-05-17 Time 16:56 Rev Time 0.00
Received By aclange Date 2016-04-25 Time 13:02 Sent To  
Notes
2016-04-25 13:02:32ROUTED TO ELECTRICAL INBOX