Plan Review Details - Permit 16040905
Plan Review Stops For Permit 16040905
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-05-26 Cont ID  
Sent By skennedy Date 2016-05-26 Time 15:23 Rev Time 0.00
Received By skennedy Date 2016-05-26 Time 15:23 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-05-17 Cont ID  
Sent By cthroop Date 2016-05-17 Time 13:58 Rev Time 0.00
Received By cthroop Date 2016-05-17 Time 12:09 Sent To  
Notes
2016-05-17 14:05:231ST REVIEW: FBC 2014 5TH ED
 CHRISTOPHER S. THROOP, C.B.O.
 BLDG. PLANS EXAMINER ? PX3169
 (561) 805-7918
 [email protected]
  
  
 1. PROVIDE ENERGY CALCULATIONS.
  
 FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402
 SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO
 DEMONSTRATE CODE COMPLIANCE BY THIS METHOD.
  
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-05-20 Cont ID  
Sent By skennedy Date 2016-05-20 Time 14:36 Rev Time 0.00
Received By skennedy Date 2016-05-20 Time 14:36 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-04-28 Cont ID  
Sent By mvaldes Date 2016-04-28 Time 16:22 Rev Time 0.00
Received By mvaldes Date 2016-04-28 Time 15:47 Sent To  
Notes
2016-04-28 16:40:25JOB PERMIT NUMBER: 16040905
 JOB ADDRESS: 3301 N FLAGLER DR
 WEST PALM BEACH FLORIDA 33407
 DATE: APRIL 28 2016
  ELECTRICAL PLAN REVIEW COMMENTS
  
 THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION
 HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF
 THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC,
 (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST
 PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF
 SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED.
  
 - NEC 210.12B - OUTLETS TO BE AFCI PROTECTED.
 - NEC 406.11- PROVIDE TAMPER RESISTANT RECEPTACLES.
 - SMOKE ALARMS REQUIRED PER RESIDENTIAL CODE SECTIONS
 314 & 315.
 - EXTERIOR DOORS BY TV ROOM AND KITCHEN ARE MISSING A
 SWITCHED LIGHTING OUTLET ACCORDING TO NEC 210.70 A (2)
 (B)
 - PROVIDE AN INTERSYSTEM BONDING STRIP TERMINAL , ADD
 TO GROUNDING DETAIL IN RISER DIAGRAM. NEC 250.94
 - NEC 210.63 HVAC EQUIPMENT SERVICE OUTLET. A 125 VOLT,
 SINGLE-PHASE, 15 OR 20-AMPERE-RATED RECEPTACLE OUTLET
 SHALL BE INSTALLED AT AN ACCESSIBLE LOCATION FOR THE
 SERVICING OF HVAC EQUIPMENT. THE RECEPTACLE SHALL BE
 LOCATED WITHIN 25 FT. OF THE EQUIPMENT.
 - MAKE SURE NEW SERVICE LOCATION SHALL COMPLY WITH NEC
 TABLE 680.8 POOL OVERHEAD CONDUCTORS CLEARANCES.
  
 PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE
 MENTIONED DEFICIENCIES.
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE
 LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE
 STANDARD CITY RE-SUBMITTAL FORM. THE NARRATIVE SHOULD
 INCLUDE THE PLAN REVIEWER?S COMMENTS AND YOUR RESPONSE
 OR ACTION TO SAME. ADDITIONALLY, PLEASE INSERT
 CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE
 PREVIOUSLY REVIEWED SHEETS FOR COMPARISON.
 CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 FBC 2014 5TH ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 516-805-6713
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-05-26 Cont ID  
Sent By skennedy Date 2016-05-26 Time 15:23 Rev Time 0.00
Received By skennedy Date 2016-04-20 Time 14:14 Sent To  
Notes
2016-04-20 14:14:30R18

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2016-05-26 Cont ID  
Sent By skennedy Date 2016-05-26 Time 15:23 Rev Time 0.00
Received By skennedy Date 2016-05-26 Time 15:23 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2016-05-17 Cont ID  
Sent By cthroop Date 2016-05-17 Time 13:56 Rev Time 0.00
Received By cthroop Date 2016-05-17 Time 13:56 Sent To  
Notes
2016-05-17 13:58:071ST REVIEW: FBC 2014 5TH ED
 CHRISTOPHER S. THROOP, C.B.O.
 BLDG. PLANS EXAMINER ? PX3169
 (561) 805-7918
 [email protected]
  
 PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN AND
 TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURN STAMPED
 WITH A COPY OF RECEIPT AS APPLICABLE.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2016-05-26 Cont ID  
Sent By skennedy Date 2016-05-26 Time 15:23 Rev Time 0.00
Received By skennedy Date 2016-05-26 Time 15:23 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-05-17 Cont ID  
Sent By jvalido Date 2016-05-17 Time 18:21 Rev Time 0.00
Received By jvalido Date 2016-05-17 Time 18:12 Sent To  
Notes
2016-05-17 18:21:29CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA
 BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION
  
 FBC RESIDENTIAL 2014
  
 107.1 CONSTRUCTION DOCUMENTS & 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS
  
 PROVIDE A DETAILED PLAN SHOW ALL MECHANICAL HVAC WORK
 DONE.

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-05-04 Cont ID  
Sent By gearl Date 2016-05-04 Time 12:09 Rev Time 0.00
Received By gearl Date 2016-05-04 Time 12:08 Sent To  
Notes
2016-05-04 12:11:08 
  
  
  
 1. NEED TO HAVE PLUMBING RISER DIAGRAM FOR MASTER
 BATHROOM AT 1ST ROUGH INSPECTION
  
 GEORGE EARL PLUMBING PLANS REVIEWER 0013 B

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2016-05-17 Cont ID  
Sent By cthroop Date 2016-05-17 Time 13:56 Rev Time 0.00
Received By cthroop Date 2016-05-17 Time 13:56 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2016-05-23 Cont ID  
Sent By ajones Date 2016-05-23 Time 12:13 Rev Time 0.00
Received By ajones Date 2016-05-23 Time 12:13 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved