Plan Review Details - Permit 16040764
Plan Review Stops For Permit 16040764
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-06-22 Cont ID  
Sent By cthroop Date 2016-06-22 Time 14:50 Rev Time 0.00
Received By cthroop Date 2016-06-22 Time 13:08 Sent To HIST
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-05-17 Cont ID  
Sent By cthroop Date 2016-05-17 Time 14:44 Rev Time 0.00
Received By cthroop Date 2016-05-17 Time 14:29 Sent To  
Notes
2016-05-17 14:46:391ST REVIEW: FBC 2014 5TH ED
 CHRISTOPHER S. THROOP, C.B.O.
 BLDG. PLANS EXAMINER ? PX3169
 (561) 805-7918
 [email protected]
  
 1. PROVIDE SHORING PLAN FOR THE REMOVAL OF LOAD BEARING
 WALLS.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-06-17 Cont ID  
Sent By vperez Date 2016-06-17 Time 09:33 Rev Time 0.00
Received By vperez Date 2016-06-17 Time 09:28 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date   Cont ID  
Sent By   Date 2016-04-28 Time 12:18 Rev Time 0.00
Received By albarran Date 2016-04-28 Time 08:56 Sent To  
Notes
2016-04-28 12:15:42ELECTRICAL REVIEW COMMENTS
 REVIEWED FOR COMPLIANCE WITH:
 5TH EDITION OF THE FBC 2014 & NFPA 70 (NEC) 2011
 EDITION
  
 CORRECTIONS REQUIRED:
 1. NEC 404.2(C). WHERE SWITCHES CONTROLLING LIGHTING
 LOADS SUPPLIED BY A GROUNDED BRANCH CIRCUIT, THE
 GROUNDED BRANCH CIRCUIT CONDUCTOR FOR THE CONTROLLED
 LIGHTING CIRCUIT SHALL BE PROVIDED AT THE SWITCH.
 2. SHOW FIXED APPLIANCE CIRCUITS ON THE PANEL SCHEDULE
 AND INCLUDE THEM INTO THE LOAD CALCS.
 3. NEC 210.52(E)(1) REQUIRES THAT THERE BE A GFCI
 PROTECTED OUTLET IN THE FRONT AND REAR OF EVERY
 DWELLING UNIT WITH GRADE LEVEL ACCESS.
 4. NEC 210.52(D) BATHROOMS. IN DWELLING UNITS, AT LEAST
 ONE RECEPTACLE OUTLET SHALL BE INSTALLED IN BATHROOMS
 WITHIN 3 FT. OF THE OUTSIDE EDGE OF EACH BASIN. OUTLET
 IS MISSING IN THE DOWNSTAIRS BATHROOM.
 5. NEC 210.52 (A)(1) SPACING. RECEPTACLES SHALL BE
 INSTALLED SUCH THAT NO POINT MEASURED HORIZONTALLY
 ALONG THE FLOOR LINE IN ANY WALL SPACE IS MORE THAN 6
 FT. FROM A RECEPTACLE OUTLET. THIS INCLUDES THE
 DISTANCE FROM THE EDGE OF THE WALL. OUTLETS MISSING IN
 KITCHEN WALL; OUTLET SPACING ON GREAT ROOM WALLS;
 MASTER BEDROOM; BEDROOM 2; WALL BENEATH ELECTRICAL
 PANEL, THE GREAT ROOM WALL TO KITCHEN IS 25?; BY CODE
 IT SHOULD HAVE 3 OUTLETS NOT 2, ALSO CHECK FRONT WALL
 WHICH HAS 18? BETWEEN OUTLETS.
 6. NEC 210.52 (A)(2) WALL SPACE. ANY WALL SPACE 2 FT.
 OR MORE IN WIDTH SHALL REQUIRE A RECEPTACLE. THERE ARE
 OUTLETS MISSING IN THE GREAT ROOM AND BEDROOM 4
 7. PROVIDE MANUFACTURER SPECS FOR THE TANKLESS WATER
 HEATERS. 13KW IS NOT TO BE PROTECTED OR WIRED AS
 INDICATED ON PANEL SCHEDULE. CORRECT ACCORDINGLY AND
 ADJUST LOAD CALCS IF NECESSARY.
 8. PER NEC 422.31(B) A DISCONNECT IS REQUIRED FOR THE
 TANKLESS WATER HEATERS.
 9. THE LOAD CALCS AND PANEL SCHEDULE DO NOT MATCH.
 INCLUDE THE SECOND HVAC UNIT ON PANEL SCHEDULE AND
 ADJUST THE LOAD CALCS CORRECTLY.
 10. NEC 110.33(B) A PERMANENT LADDER OR STAIRWAY SHALL
 BE PROVIDED TO GIVE SAFE ACCESS TO THE WORKING SPACE
 AROUND ELECTRICAL EQUIPMENT INSTALLED ON PLATFORMS,
 BALCONIES, OR MEZZANINE FLOORS OR IN ATTIC OR ROOF
 ROOMS? SPACES. ELSEWHERE IN THE CODE YOU ARE REQUIRED
 TO PROVIDE A LIGHT SWITCHED AT THE ENTRANCE TO THE
 ATTIC THAT ILLUMINATES THE EQUIPMENT IN QUESTION AND A
 GFI OUTLET WITHIN READY ACCESS.
 11. NEC 314.27(D) PADDLE FANS. BOXES USED FOR THE SOLE
 SUPPORT OF CEILING FANS SHALL BE MARKED BY THE
 MANUFACTURER AS SUITABLE FOR THE PURPOSE, AND INDICATE
 THE WEIGHT LIMITATIONS BUT SHALL NOT BE USED TO SUPPORT
 PADDLE FANS HEAVIER THAN 70 LBS.
 12. NEC 410.16(B) PROHIBITS THE USE OF THE TRADITIONAL
 PORCELAIN PULL CHAIN FIXTURES IN CLOSETS. USE A
 SUITABLE WALL SWITCHED LUMINARIES.
  
 FOR A BETTER UNDERSTANDING OR INDICATION AS TO THE
 ABOVE COMMENTS, FEEL FREE TO SIGN OUT THE PLAN SET
 MARKED ?CONTRACTOR?S COPY?.
  
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER
 (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER
 WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD
 CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID
 AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR
 COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE
 GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 THANK YOU,
 MIKE ALBARRAN
 ELECTRICAL PLANS EXAMINER
 PH: 561-805-6746
 EMAIL: [email protected]
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2016-06-23 Cont ID  
Sent By destabro Date 2016-06-23 Time 10:19 Rev Time 0.00
Received By destabro Date 2016-06-23 Time 10:19 Sent To I
Notes
2016-06-23 10:21:086/23/16 - PLANS REFLECT PREVIOUSLY REQUESTED CHANGES.
 NOTE THAT WINDOW REPLACEMENT IS NOT YET APPROVED BY HPB
 - PERMIT DRAWINGS CORRECTED TO REFLECT SUBMITTED COA.
 DLE

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2016-05-06 Cont ID  
Sent By fmittner Date 2016-05-06 Time 11:44 Rev Time 0.00
Received By destabro Date 2016-05-06 Time 11:44 Sent To  
Notes
2016-05-06 11:46:40PER THE COA:
 THE HISTORIC PRESERVATION SECTION HAS REVIEWED THE
 APPLICATION AND PLANS DATED 4/6/2016. THE APPLICATION
 HAS BEEN APPROVED WITH THE FOLLOWING CONDITIONS:
 1.) INSTALL BANDING ELEMENT OR REPLICATE ROOFING DETAIL
 (EXPOSED RAFTER TAILS) BETWEEN THE FIRST AND (PROPOSED)
 SECOND FLOOR ON THE REAR ADDITION TO DIFFERENTIATE THE
 EXISTING STRUCTURE FROM THE NEW CONSTRUCTION.
 2.) MATCH NEW SIDING IN MATERIAL AND WIDTH TO THE
 EXISTING SIDING ON THE MAIN HOUSE.
 3.) IF FEASIBLE, REPLICATE REAR (NORTH) ATTIC DORMER ON
 NEW 2ND STORY REAR ADDITION.
  
 THE PROVIDED ELEVATIONS ACCOMPANYING THIS PERMIT
 (16040764) DO NOT REFLECT THESE CHANGES, NOR DO THEY
 ADDRESS THE MUNTIN PATTERNS OF THE EXISTING WINDOWS.
 PLEASE PROVIDE REVISED PLANS THAT MATCH THE APPROVED
 COA. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT HISTORIC
 PRESERVATION PLANNER, DESIREE ESTABROOK, AT
 561.822.1428.
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2016-06-27 Cont ID  
Sent By cthroop Date 2016-06-27 Time 13:21 Rev Time 0.00
Received By cthroop Date 2016-06-27 Time 13:21 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-06-23 Cont ID  
Sent By destabro Date 2016-06-23 Time 10:21 Rev Time 0.00
Received By cpuell Date 2016-06-10 Time 10:10 Sent To  
Notes
2016-06-13 10:10:40R22

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-05-17 Cont ID  
Sent By cthroop Date 2016-05-17 Time 14:44 Rev Time 0.00
Received By cthroop Date 2016-04-20 Time 10:19 Sent To  
Notes
2016-04-21 10:19:27R23

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-04-18 Cont ID  
Sent By skennedy Date 2016-04-18 Time 12:31 Rev Time 0.00
Received By skennedy Date 2016-04-15 Time 12:31 Sent To  
Notes
2016-04-18 12:32:45FBC 2014 RESIDENTIAL
  
 THE DESCRIPTION ON THE APPLICATION IS:
 TRUSS PACKAGE DIFFERED SUBMITTAL. THERE IS NO OTHER
 ACTIVE APPLICATION AT THE ADDRESS. THE SUBMITTAL IS
 DENIED AND PLACED ON HOLD UNTIL FURTHERR CLARIFIED AND
 FEES ARE PAID. THERE IS ONLY ONE SET OF PLANS.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2016-06-27 Cont ID  
Sent By cthroop Date 2016-06-27 Time 13:21 Rev Time 0.00
Received By cthroop Date 2016-06-27 Time 13:21 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2016-05-17 Cont ID  
Sent By cthroop Date 2016-05-17 Time 15:25 Rev Time 0.00
Received By cthroop Date 2016-05-17 Time 15:25 Sent To  
Notes
2016-05-17 15:26:501ST REVIEW: FBC 2014 5TH ED
 CHRISTOPHER S. THROOP, C.B.O.
 BLDG. PLANS EXAMINER ? PX3169
 (561) 805-7918
 [email protected]
  
 PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN AND
 TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURN STAMPED
 WITH A COPY OF RECEIPT AS APPLICABLE.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2016-05-02 Cont ID  
Sent By jvalido Date 2016-05-02 Time 16:13 Rev Time 0.00
Received By jvalido Date 2016-05-02 Time 14:53 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-06-16 Cont ID  
Sent By gearl Date 2016-06-16 Time   Rev Time 0.00
Received By gearl Date 2016-06-16 Time 14:09 Sent To  
Notes
2016-06-16 14:09:51NEED MANUFACTURE SPEC'S ON WATER HEATER ON SITE AT
 FIRST INSPECTION

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-04-29 Cont ID  
Sent By gjohnson Date 2016-04-29 Time 17:33 Rev Time 0.00
Received By gjohnson Date 2016-04-29 Time 17:33 Sent To  
Notes
2016-04-29 17:46:171ST REVIEW: FBC 2014
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1.SHOW KITCHEN SINK AMD NEW LAUNDRY ON RISER DIAGRAM.
 PER WPB AMEND. TO FBC SEC. 107.3.5.3(11)
  
 2.CLEAN OUT REQUIRED AT THE BASE OF ALL SOIL AND WASTE
 STACKS. PER FBC PL SEC. P3005.2.6
  
 3. PROVIDE MANUFACTURE SPECS FOR TANKLESS HEATER. PER
 WPB AMEND TO FBC 107.2.1
  
 4. SHOW EXISTING LOCATION OF WATER HEATER. PER WPB
 AMEND TO FBC 107.2.1
  
 5.SHOW ON THE RISER WHAT IS EXIST AND WHAT IS AND. .
 PER WPB AMEND TO FBC 107.2.1
  
 6.SCOPE OF WORK DOES NOT LIST NEW ADDITION PLEASE
 CLARIFY. . PER WPB AMEND TO FBC 107.2.1

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2016-05-17 Cont ID  
Sent By cthroop Date 2016-05-17 Time 14:44 Rev Time 0.00
Received By cthroop Date 2016-05-17 Time 14:39 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2016-05-06 Cont ID  
Sent By destabro Date 2016-05-06 Time 11:36 Rev Time 0.00
Received By destabro Date 2016-05-06 Time 11:36 Sent To  
Notes
2016-05-06 11:39:175-6-2016 - 2ND STORY REAR ADDITION APPROVED AT HPD
 LEVEL, MEETS LOT COVERAGE AND FAR REQUIREMENTS PER
 ZONING AND LAND DEVELOPMENT REGULATIONS. - DLE