Plan Review Details - Permit 16040672
Plan Review Stops For Permit 16040672
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-05-12 Cont ID  
Sent By shill Date 2016-05-12 Time 08:35 Rev Time 0.00
Received By shill Date 2016-05-12 Time 08:35 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-05-04 Cont ID  
Sent By shill Date 2016-05-04 Time 11:43 Rev Time 0.00
Received By shill Date 2016-05-04 Time 11:43 Sent To  
Notes
2016-05-04 11:45:22****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. REVISE THE FLOOR PLAN TO SHOW ROOM DESIGNATIONS.
  
 2. FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN
 HEIGHT, NOTE EXISTING CONDITIONS (TYPE OF WINDOW) AND
 OPENING SIZE FOR BEDROOMS, FBC R310, FBC EB 704.1. THE
 CLEAR OPENING CANNOT BE REDUCED BY MORE THAN 5%.
  
 TO PROVIDE FURTHER CLARIFICATION REGARDING INFORMATION
 NEEDED FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN
 HEIGHT:
  
 STATE WHAT TYPE OF WINDOW IS THERE NOW IN THE BEDROOMS
 - AWNING, CASEMENT, SINGLE HUNG?
  
 STATE WHAT THE EXISTING CLEAR OPENING DIMENSIONS ARE.
 CLEAR OPENING IS THE OPENING WHICH EXISTS WHEN THE
 WINDOW IS FULLY OPEN.
  
 STATE WHAT THE PROPOSED CLEAR OPENING DIMENSIONS ARE.
 THIS CAN BE OBTAINED FROM THE MANUFACTURER.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-05-12 Cont ID  
Sent By shill Date 2016-05-12 Time 08:35 Rev Time 0.00
Received By shill Date 2016-05-05 Time 13:03 Sent To  
Notes
2016-05-05 13:04:02SHILL'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-05-04 Cont ID  
Sent By shill Date 2016-05-04 Time 11:45 Rev Time 0.00
Received By shill Date 2016-04-13 Time 15:30 Sent To  
Notes
2016-04-13 15:30:23BLDG MISC 1