Plan Review Details - Permit 16040411
Plan Review Stops For Permit 16040411
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-05-19 Cont ID  
Sent By shill Date 2016-05-19 Time 16:27 Rev Time 0.00
Received By shill Date 2016-05-19 Time 16:27 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-04-19 Cont ID  
Sent By shill Date 2016-04-19 Time 13:47 Rev Time 0.00
Received By shill Date 2016-04-19 Time 13:47 Sent To  
Notes
2016-04-19 13:49:08****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. REVISE THE FLOOR PLAN TO PROVIDE THE FOLLOWING
 INFORMATION: WINDOW TYPE IN EACH OPENING, ROOM
 DESIGNATIONS. FBC 107, PLAN SHOULD BE CLEAR AS TO
 SCOPE. TWO DIFFERENT WINDOW PRODUCT APPROVALS PROVIDED,
 ONE IMPACT AND ONE NON IMPACT, AND A MULLION PRODUCT
 APPROVAL. FLOOR PLAN APPEARS TO SHOW A WINDOW AND A
 DOOR. REVISE FLOOR PLAN TO SHOW PROPOSED INSTALLATION,
 SIZES OF INDIVIDUAL WINDOWS, MULLION SPAN. SCOPE IS NOT
 ADEQUATELY SHOWN.
  
 2. FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN
 HEIGHT, NOTE EXISTING CONDITIONS (TYPE OF WINDOW) AND
 OPENING SIZE FOR BEDROOMS, FBC R310, FBC EB 704.1. THE
 CLEAR OPENING CANNOT BE REDUCED BY MORE THAN 5%.
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-05-19 Cont ID  
Sent By shill Date 2016-05-19 Time 16:27 Rev Time 0.00
Received By shill Date 2016-05-19 Time 08:28 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-04-19 Cont ID  
Sent By shill Date 2016-04-19 Time 13:52 Rev Time 0.00
Received By shill Date 2016-04-18 Time 12:46 Sent To  
Notes
***NONE***