Plan Review Details - Permit 16040039
Plan Review Stops For Permit 16040039
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2016-05-23 Cont ID  
Sent By cthroop Date 2016-05-23 Time 10:38 Rev Time 0.00
Received By cthroop Date 2016-05-23 Time 10:32 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2016-05-17 Cont ID  
Sent By cthroop Date 2016-05-17 Time 08:35 Rev Time 0.00
Received By cthroop Date 2016-05-17 Time 08:35 Sent To  
Notes
2016-05-17 08:59:433RD REVIEW: FBC 2014 5TH ED
 CHRISTOPHER S. THROOP, C.B.O.
 BLDG. PLANS EXAMINER ? PX3169
 (561) 805-7918
 [email protected]
  
 1. PROVIDE FASTENER SCHEDULE FOR WOOD AND DRYWALL
 REPLACEMENT.
 2. PROVIDE REPAIR DETAIL FOR REMOVAL OF CONCRETE SLAB.
 3. PROVIDE DETAIL FOR RATED FLOOR/CEILING ASSEMBLY.
 4. PROVIDE FLOOR PLAN WITH DEMENSIONS.
 5. DESIGNER TO SIGN PALNS.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES
 SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE
 TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE
 FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE
 DESIGN. (SEE ALSO SECTION 107.3.5).
  
 R302.3 TWO-FAMILY DWELLINGS.
 DWELLING UNITS IN TWO-FAMILY DWELLINGS SHALL BE
 SEPARATED FROM EACH OTHER BY WALL AND/OR FLOOR
 ASSEMBLIES HAVING NOT LESS THAN A 1-HOUR
 FIRE-RESISTANCE RATING WHEN TESTED IN ACCORDANCE WITH
 ASTM E 119 OR UL 263. FIRE-RESISTANCE-RATED
 FLOOR/CEILING AND WALL ASSEMBLIES SHALL EXTEND TO AND
 BE TIGHT AGAINST THE EXTERIOR WALL, AND WALL ASSEMBLIES
 SHALL EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF
 THE ROOF SHEATHING.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-04-07 Cont ID  
Sent By cthroop Date 2016-04-07 Time 08:56 Rev Time 0.00
Received By cthroop Date 2016-04-07 Time 08:56 Sent To  
Notes
2016-04-29 11:26:361ST REVIEW: FBC 2014 5TH ED
 CHRISTOPHER S. THROOP, C.B.O.
 BLDG. PLANS EXAMINER ? PX3169
 (561) 805-6718
 [email protected]
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
  
 1. PROVIDE FLOOR PLAN WITH DEMENSIONS OF ALL AREAS OF
 PROJECT THAT WORK SHALL BE PERFORMED.
 2. PROVIDE DETAILED SCOPE OF WORK.
 3. PROVIDE FASTENER SCHEDULE FOR ALL DRYWALL AND WOOD
 SHEATHING, (FLOOR & WALLS).
 4. PROVIDE DOOR AND WINDOW SCHEDULE FOR ANY REPLACEMENT
 DOORS &/OR WINDOWS.
 5. PROVIDE DETAIL ON TENANT SEPERATION WALLS (FIRE
 WALL).
 6. PROVIDE DETAIL ON HORIZONTAL RATED FLOOR/CEILING
 ASSEMBLIES.
 7. DESIGNER TO SIGN PLANS.
 8. ADDITIONAL COMMENTS MAY BE GENERATED UPON REVIEW OF
 PROPERLY SUBMITTED DOCUMENTS.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES
 SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE
 TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE
 FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE
 DESIGN. (SEE ALSO SECTION 107.3.5).
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status N Date 2016-04-05 Cont ID  
Sent By cthroop Date 2016-04-05 Time 13:12 Rev Time 0.00
Received By cthroop Date 2016-04-05 Time 13:11 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2016-04-04 Cont ID  
Sent By mvaldes Date 2016-04-04 Time 18:11 Rev Time 0.00
Received By mvaldes Date 2016-04-04 Time 18:11 Sent To  
Notes
2016-04-04 18:11:55ROUTED TO CHRIS THROOP.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-05-23 Cont ID  
Sent By cthroop Date 2016-05-23 Time 10:39 Rev Time 0.00
Received By cthroop Date 2016-05-19 Time 10:38 Sent To  
Notes
2016-05-20 10:39:11RESUB ROUTED TO CTHROOP

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-05-17 Cont ID  
Sent By cthroop Date 2016-05-17 Time 08:35 Rev Time 0.00
Received By cthroop Date 2016-05-12 Time 10:21 Sent To  
Notes
2016-05-13 10:21:19RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-04-07 Cont ID  
Sent By cthroop Date 2016-04-07 Time 08:56 Rev Time 0.00
Received By cthroop Date 2016-04-01 Time 10:12 Sent To  
Notes
2016-04-04 10:12:16ROUTED TO ELECTRICAL INBOX

Review Stop P PLUMBING
Rev No 4 Status P Date 2016-05-17 Cont ID  
Sent By tklarge Date 2016-05-17 Time 14:58 Rev Time 0.00
Received By tklarge Date 2016-05-17 Time 14:58 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2016-05-17 Cont ID  
Sent By tklarge Date 2016-05-17 Time 04:54 Rev Time 0.00
Received By tklarge Date 2016-05-17 Time 03:17 Sent To  
Notes
2016-05-17 04:54:54TABLE 403.1 OF THE 2014 FBC-PLUMBING REQUIRES A MINIMUM
 OF ONE AUTOMATIC CLOTHES WASHER CONNECTION IN THE
 UNITS. THE PLANS DO NOT SHOW ANY PROVISIONS FOR
 AUTOMATIC CLOTHES WASHER CONNECTION. SHOW THE LOCATION
 OF THE AUTOMATIC CLOTHES WASHER CONNECTION ON THE FLOOR
 PLAN AND ALSO ON THE PLUMBING RISER.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2016-04-29 Cont ID  
Sent By tklarge Date 2016-04-29 Time 10:09 Rev Time 0.00
Received By tklarge Date 2016-04-29 Time 09:43 Sent To  
Notes
2016-04-29 10:09:551) SUBMIT A SANITARY DRAINAGE RISER AND A WATER RISER
 THAT CLEARLY SHOWS THE SCOPE OF PLUMBING WORK TO BE
 DONE AND HOW IT IS TO BE DONE. THE SUBMITTED DRAWING IS
 UNACCEPTABLE AND DOES NOT COMPLY WITH THE PLUMBING
 CODE.FBC 107.1, 107.2.1. THE DRAWING DOES NOT SHOW ALL
 THE PIPING THAT IS TO BE REPLACED. THERE ARE PLUMBING
 RISERS AND STACKS AND UNDERGROUND PIPING THAT IS BEING
 REPLACED THAT IS NOT BEING SHOWN ON THE PLANS.
 2) SUBMIT A FLOOR PLAN THAT CLEARLY REFLECTS THE ENTIRE
 SCOPE OF WORK TO BE DONE.CLEARLY IDENTIFY WHAT WORK IS
 BEING DONE IN WHAT AREAS. FBC 107.1.
 3) SHOW ALL FIXTURE CLEARANCE DIMENSIONS AS REQUIRED BY
 THE 2014 FBC-PLUMBING SEC. 405.3.1.
 4) PLANS SHALL BE SUBMITTED IN DUPLICATE PER THE 2014
 FBC-PLUMBING SEC.107.1.
 5) THE PLAN SHOWS A FLAT, DRY VENT ON THE SHOWER AND
 THE WATER CLOSET. VENTS SHALL CONNECT TO THE HORIZONTAL
 DRAIN PIPE IN ACCORDANCE WITH THE 2014 FBC-PLUMBING
 SEC.905.3.
 6) CLEANOUTS ARE REQUIRED IN THE BASE OF ALL STACKS PER
 2014 FBC-PLUMBING SEC.708.3.4.
 7) SIZE ALL OF THE DRAIN AND VENT PIPES IN ACCORDANCE
 WITH THE 2014 FBC-PLUMBING SECS.710.1, TABLE 710.1 (2),
 906.1, 906.2.
  
 THESE PLANS ARE SEVERELY DEFICIENT IN THE SCOPE OF
 WORK. DO NOT RESUBMIT JUST THE PLUMBING PLANS FOR
 REVIEW AGAIN. RESUBMITTED PLANS SHALL ADDRESS ALL THE
 COMMENTS FROM ALL TRADES.
  
 PLEASE REFER TO THE FLORIDA BUILDING CODE WEBSITE FOR
 FUTHER INFORMATION REGARDING THE ABOVE NOTED CODE
 SECTIONS AT WWW.FLORIDABUILDING.ORG.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  
  
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-04-06 Cont ID  
Sent By tklarge Date 2016-04-06 Time 14:39 Rev Time 0.00
Received By tklarge Date 2016-04-06 Time 14:39 Sent To  
Notes
2016-04-06 14:39:001) SUBMIT A SANITARY DRAINAGE RISER THAT CLEARLY SHOWS
 THE SCOPE OF PLUMBING WORK TO BE DONE. THE SUBMITTED
 DRAWING IS UNACCEPTABLE.FBC 107.1
 2) SUBMIT A FLOOR PLAN THAT CLEARLY REFLECTS THE ENTIRE
 SCOPE OF WORK TO BE DONE.CLAERLY IDENTIFY WHAT WORK IS
 BEING DONE IN WHAT AREAS. FBC 107.1.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  