Plan Review Details - Permit 16031271
Plan Review Stops For Permit 16031271 |
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2016-03-31 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-03-31 |
Time |
12:03 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-03-31 |
Time |
12:03 |
Sent To |
|
|
Notes |
2016-03-31 12:09:34 | REVIEW 2014 5TH FBC ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 516-805-6713 | | [email protected] | | | | | | PASSED WITH A PROVISO OF THE FOLLOWING ITEMS | | | | - ADD A SMOKE DETECTOR IN FRONT OF FACP. NFPA 72 10.15 | | , FBC 907 .4.1 | | | | - INCLUDE GENERAL NOTE STATING MECHANICAL PROTECTION | | REQUIRED AND RED MARKING LABELED " FIRE ALARM CIRCUIT " | | . NEC 760 , NFPA 72 10.5.5.2 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2016-03-29 |
|
|
Cont ID |
|
Sent By |
fstal |
Date |
2016-03-29 |
Time |
16:12 |
Rev Time |
|
Received By |
fstal |
Date |
|
Time |
|
Sent To |
E |
|
Notes |
2016-03-29 16:22:01 | (1) FIRE ALARM INSTALLATION SHALL COMPLY WITH NEC, NFPA | | 70 AND 72. ALL FIRE PROTECTION EQUIPMENT SHALL REMAIN | | INSERVICE DURING ALL PHASES OF CONSTRUCTION AND | | INSTALLATION. | | | | (2) NFPA 90A-6.4.2.1 SMOKE DETECTORS LISTED FOR USE IN | | AIR DISTRIBUTION SYSTEMS SHALL BE LOCATED AS FOLLOWS: | | DOWNSTREAM OF THE AIR FILTERS AND AHEAD OF ANY BRANCH | | CONNECTIONS IN AIR SUPPLY SYSTEMS HAVING A CAPACITY | | GREATER THAN 944 L/SEC (2000 FT3/MIN) AT EACH STORY | | PRIOR TO THE CONNECTION TO A COMMON RETURN AND PRIOR TO | | ANY RECIRCULATION OR FRESH AIR INLET CONNECTION IN AIR | | RETURN SYSTEMS HAVING A CAPACITY GREATER THAN 7080 | | L/SEC (15,000 FT3/MIN) AND SERVING MORE THAN ONE STORY. | | | | (3) NFPA 72-10.18.2.4, 2010 VERIFICATION OF COMPLIANT | | INSTALLATION. WHERE REQUIRED, COMPLIANCE OF THE | | COMPLETED INSTALLATION WITH THE REQUIREMENTS OF THIS | | CODE, AS IMPLEMENTED VIA THE REFERRING CODE(S), | | SPECIFICATIONS, AND/OR OTHER CRITERIA APPLICABLE TO THE | | SPECIFIC INSTALLATION, SHALL BE CERTIFIED BY A | | QUALIFIED AND IMPARTIAL THIRD-PARTY ORGANIZATION | | ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION. | | | | FRANK STALLWORTH, FIRE INSPECTOR I | | WEST PALM BEACH FIRE PREVENTION BUREAU | | 500 N. DIXIE HWY | | WEST PALM BEACH, FLORIDA 33401 | | OFFFICE: 561-840-4780 | | FAX: 561-840-4774 | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-03-31 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-03-31 |
Time |
12:09 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-03-28 |
Time |
10:25 |
Sent To |
|
|
Notes |
2016-03-28 10:25:21 | ROUTED TO FIRE INBOX |
|
|
|