Plan Review Stops For Permit 16031109 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2016-03-29 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-03-29 |
Time |
11:59 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-03-29 |
Time |
11:19 |
Sent To |
|
|
Notes |
2016-03-29 11:55:14 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 16031109 | | ADD: 400 N. FLAGLER DR. SUITE # 1701 | | CONT: AD SABA ENTERPRISES, INC | | TEL: 561-969-2920 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: TUES. MARCH 29/2016 | | ACTION: APPROVED. | | | | CONTRACTOR SUBMITTED MANUFACTURERS SPEC FOR WHISPER MAT | | CS. WHISPER MAT CS HAS TESTING ON-FILE AS AN APPROVED | | UNDERLAYMENT. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2016-04-18 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-04-18 |
Time |
09:14 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-04-18 |
Time |
09:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-03-29 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-03-29 |
Time |
06:43 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-03-28 |
Time |
14:58 |
Sent To |
|
|
Notes |
2016-03-29 06:56:25 | INITIAL ELECTRICAL PLAN REVIEW | | | | APPLICABLE CODES IN EFFECT: | | FLORIDA EXISTING BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70- 2011 | | COMMENTS: | | | | 1. PLEASE SHOW ON DRAWING A NOTE INDICATING THE | | RECEPTACLE OUTLETS REQUIRED FOR WALL SPACE TO ENSURE | | THAT ALL WALL RECONFIGURED COMPLIES WITH FBC RES- SEC | | E39012.1 AND 2.2 | | 2. PROVIDE A NOTE TO COMPLY WITH AFCI PROTECTION FOR | | BRANCH CIRCUITS IF NEW BRANCH IS EXTENDED FROM PANEL | | BOARD AND TAMPER RESISTANT RECEPTACLE PER FBC RES- SEC | | E3902.12 AND E4002.14 | | 3. SEE FBC RES 314 SMOKE ALARM REQUIREMENTS PER | | ALTERATION. PROVIDE SMOKE DETECTORS TO COMPLY AT THE | | GUEST BEDROOM AND AT THE ENTRANCE TO ROOMS. | | 4. SHOW THE NEW LOCATION OF ELECTRICAL PANEL THAT WAS | | RELOCATED DUE TO WALL DEMO. FBC 107.3.5 | | 5. LABEL ALL RECEPTACLES IN BATHROOM AREA TO GFCI | | PROTECTED. FBC RES E3902.1 | | 6. 75% OF LAMP TO BE HIGH EFFICACY LAMPS PER FBC EC | | 404.1- A NOTE WILL SUFFICE. | | 7. FURTHER COMMENTS MAY FOLLOW UPON RESUBMITTAL. FEEL | | FREE TO CONTACT ME AT THE NUMBER LISTED BELOW SHOULD | | YOU HAVE ANY QUESTIONS OR CONCERNS. | | | | VALENTINO PEREZ | | ELECTRICAL PLANS EXAMINER II | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2016-03-31 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-03-31 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-03-31 |
Time |
14:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
|
Date |
2016-07-15 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2016-07-15 |
Time |
16:21 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2016-07-15 |
Time |
16:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-04-18 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-04-18 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-04-18 |
Time |
09:15 |
Sent To |
|
|
Notes |
2016-04-14 08:57:56 | RESUB ROUTED TO CCOLE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-04-10 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-04-10 |
Time |
05:14 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-03-24 |
Time |
13:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2016-03-29 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-03-29 |
Time |
11:55 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-03-29 |
Time |
11:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2016-04-18 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-04-18 |
Time |
09:28 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-04-18 |
Time |
07:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-03-29 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-03-29 |
Time |
10:26 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-03-29 |
Time |
10:26 |
Sent To |
|
|
Notes |
2016-03-29 10:28:26 | 1ST REVIEW: FBC 2014 MECHANICAL | | PERMIT #16031109 | | 3/29/16 | | | | 1) SUBMIT MECHANICAL PLANS INDICATING ALL ALTERATIONS | | AND MODIFICATIONS TO THE EXISTING HVAC SYSTEMS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2016-04-10 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-04-10 |
Time |
05:13 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-04-10 |
Time |
05:02 |
Sent To |
|
|
Notes |
|
|