Plan Review Stops For Permit 16030757 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2016-04-29 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-04-29 |
Time |
10:23 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-04-29 |
Time |
10:23 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-03-31 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-03-31 |
Time |
11:55 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-03-31 |
Time |
11:55 |
Sent To |
P |
|
Notes |
2016-03-31 11:57:18 | 1ST REVIEW: FBC 2014 5TH ED | | CHRISTOPHER S. THROOP, C.B.O. | | BLDG. PLANS EXAMINER ? PX3169 | | (561) 805-6718 | | [email protected] | | | | 1. PLUMBING PERMIT REQUIRED. | | 2. IDENTIFY LOCATION OF NEW DRYWALL. | | 3. STATE R-VALUE OF NEW INSULATION. | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND | | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM | | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, | | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE | | TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC, | | AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE | | OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | SECTION 107.3.5). | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2016-04-29 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-04-29 |
Time |
08:35 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-04-29 |
Time |
08:35 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-03-21 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-03-21 |
Time |
08:20 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-03-21 |
Time |
08:20 |
Sent To |
B |
|
Notes |
2016-03-21 08:21:03 | INITIAL ELECTRICAL PLAN REVIEW | | | | APPLICABLE CODES IN EFFECT: | | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA EXISTING BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70- 2011 NEC | | COMMENTS: | | | | 1. ELECTRICAL SHEET- PLEASE UPDATE ALL REFERENCES TO | | REFLECT CURRENT BUILDING CODES. FLORIDA BUILDING CODE | | 2014 5TH EDITION FAMILY, NEC 2011. | | 2.PLEASE CLARIFY ELECTRICAL SCOPE AND LABEL PLANS | | ACCORDINGLY. LABEL NEW OR EXISTING FOR EXAMPLE INTERIOR | | DEVICES. FBC 107.3.5 | | 3.ELECTRICAL CONTRACTOR TO SIGN AND NOTARIZED SIGNATURE | | ON DRAWINGS IF NO DESIGNER OF RECORD IS SHOWN FOR THIS | | PROJECT. ELECTRICAL PERMIT REQUIRED | | 4.SHOW PROPER SPACING AT THE KITCHEN LOCATION AND | | THROUGHOUT SCOPE. PER FBC RES E3901- WALL SPACE | | REQUIREMENTS AND COUNTERTOP WALL SPACE IN KITCHEN AREA. | | 5.SHOW THE SMOKE DETECTORS LAYOUT PER FBC RES 314 | | REQUIREMENTS | | 6.NEW SLIDING GLASS DOOR, PLEASE CLARIFY IF THERE IS AN | | EXISTING SWITCH AND LIGHTING OUTLET TO COMPLY WITH FBC | | RES E3903, IF NOT SHOW ON DRAWINGS. | | 7.TAMPER RESISTANT RECEPTACLES REQUIRED, PROVIDE A NOTE | | TO COMPLY. FBC RES E4002.14 | | 8.FURTHER COMMENTS MAY FOLLOW UPON RE-REVIEW. FEEL FREE | | TO CONTACT ME AT THE NUMBER LISTED BELOW SHOULD YOU | | HAVE ANY QUESTIONS OR CONCERNS. | | | | | | | | VALENTINO PEREZ | | ELECTRICAL PLANS EXAMINER II | | 561-805-6717 | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-05-03 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-05-03 |
Time |
11:56 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-04-28 |
Time |
16:25 |
Sent To |
|
|
Notes |
2016-04-28 16:25:52 | RESUB ROUTED TO VPEREZ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-04-04 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-04-04 |
Time |
05:14 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-04-04 |
Time |
05:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-03-31 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-03-31 |
Time |
11:52 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-03-17 |
Time |
14:01 |
Sent To |
|
|
Notes |
2016-03-31 11:54:46 | CLOSED I-STOP BY MISTAKE. WILL OPEN NEW I-STOP. SENT TO | | PLUMBING. CST | 2016-03-17 14:02:14 | ROUTED TO ELECTRICAL INBOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2016-05-03 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2016-05-03 |
Time |
12:04 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2016-05-03 |
Time |
12:04 |
Sent To |
|
|
Notes |
2016-05-03 12:12:42 | NO PLAN SUBMITTED, REVISION REQUIRED. APPROVED TO | | EXPEDITE FIRE REPAIR. | | | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2016-05-03 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-05-03 |
Time |
11:56 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-05-02 |
Time |
04:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2016-04-04 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-04-04 |
Time |
05:14 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-04-04 |
Time |
05:10 |
Sent To |
|
|
Notes |
|
|