Plan Review Stops For Permit 16030508 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2016-04-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-04-05 |
Time |
09:01 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-04-05 |
Time |
07:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-03-21 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-03-21 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-03-21 |
Time |
08:41 |
Sent To |
|
|
Notes |
2016-03-21 10:45:23 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 16030508 | | ADD: 477 S. ROSEMARY SUITE # 230 | | CONT: TBD | | TEL: 684-6844/ NIKI BENNETT | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: MON. MARCH 21/2016 | | ACTION: DENIED | | | | 1) PLEASE REVIEW SHEET 004_A1.0 CORRIDOR 206 AND SHEET | | 16044_M1_1. PLEASE REVIEW 2014 FBC-B 1018.5 AIR | | MOVEMENT IN CORRIDORS. CORRIDORS SHALL NOT SERVE AS | | SUPPLY, RETURN, EXHAUST, RELIEF OR VENTILATION AIR | | DUCTS. THE MECHANICAL PLANS SHOW THE RETURN AIR IS | | BEING PULLED DOWN THRU THE CEILING ABOVE INTO THE | | CORRIDOR AND INTO THE AIR HANDLER CLOSET 209. THE DOOR | | SCHEDULE INDICATES THIS DOOR IS A WOOD LOUVERED DOOR. | | THE 2014 FBC-M DOES NOT ALLOW COMBUSTIBLE MATERIALS | | WITHIN PLENUMS. THE SAME ISSUE WITH DOOR 224B, NO | | COMBUSTIBLES ALLOWED WITHIN PLENUMS. | | | | NOTE FBC-B 1018.5 EXC. # 3 IS FOR OFFICES LESS THAN | | 1,000 SQ. FT. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2016-04-06 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-04-06 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-04-04 |
Time |
18:49 |
Sent To |
|
|
Notes |
2016-04-06 13:49:10 | ALL PREVIOUSLY MENTIONED DEFICIENCIES HAVE BEEN | | SATISFACTORILY CORRECTED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2016-03-29 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-03-29 |
Time |
09:43 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-03-29 |
Time |
07:58 |
Sent To |
|
|
Notes |
2016-03-29 09:45:36 | REVIEW COMPLETED AFTER RECEIVING THE MISSING E1.1. | | GLIDDEN SPINA, CP, LEM & SAK NOTIFIED VIA EMAIL. MA |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-03-22 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-03-22 |
Time |
12:55 |
Rev Time |
|
Received By |
albarran |
Date |
2016-03-18 |
Time |
12:02 |
Sent To |
|
|
Notes |
2016-03-22 12:56:20 | 1ST ELECTRICAL REVIEW NOTES FOR REVISION #:16030508 | | REVIEWED FOR COMPLIANCE WITH: | | 5TH EDITION FBC 2014 | | NFPA 70 2011 (NEC) | | | | CORRECTIONS REQUIRED: | | SHEET E0.1 | | 1. DEMOLITION NOTES 10 HAVE UNDEFINED CODE QUOTED. SEE | | CURRENT ADOPTED APPLICABLE CODE WHICH MAY NOT | | NECESSARILY BE THE LATEST EDITIONS. | | 2. SHEET E1.1 ELECTRICAL POWER PLAN IS MISSING. PLEASE | | PROVIDE THIS SHEET FOR REVIEW. PLEASE NOTE THAT THE | | FAILURE TO INCLUDE THIS SHEET IN THE INITIAL SUBMITTAL | | MAY CREATE THE NEED FOR A SECOND RESUBMITTAL AS THIS | | PAGE IS REVIEWED. | | SHEET E2.1 | | 1. IN ADDITION TO THE LIGHTING CONTROLLED MENTIONED. | | COMPLIANCE W/FBC-EC405.2.2.3 DAYLIGHT ZONES SHALL BE | | CONTROLLED SEPARATELY. | | 2. FBC-E C402.4.8 RECESSED LIGHTING. RECESSED LIGHTING | | INSTALLED IN THE BUILDING THERMAL ENVELOPE SHALL BE IC | | RATED AND BE SEALED TO LIMIT AIR LEAKAGE BETWEEN | | CONDITIONED & UNCONDITIONED SPACES. | | SHEET E3.1 | | 1. NEC 110.16 ARC-FLASH HAZARD WARNING LABELS REQUIRED | | ON ALL ELECTRICAL APPARATUS. | | 2. NEC 110.24 MAXIMUM AVAILABLE FAULT CURRENT SHALL BE | | DURABLY MARKED AND DATED ON ALL ELECTRICAL APPARATUS. | | 3. NEC 408.4(B) ALL SWITCHBOARDS AND PANELBOARDS | | SUPPLIED BY A FEEDER IN OTHER THAN A ONE OR TWO FAMILY | | DWELLING SHALL BE MARKED TO INDICATE THE LOCATION AND | | TYPE OF THE SOURCE OF POWER. | | SHEET E5.1 | | 1. INCLUDE THE PROPOSED FIRE STOPPING DETAIL FOR | | ELECTRICAL OUTLET BOX IN A RATED WALL. | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER | | (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER | | WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | GREATLY APPRECIATED. | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | | | THANK YOU, | | MIKE ALBARRAN | | ELECTRICAL PLANS EXAMINER | | PH: 561-805-6746 | | EMAIL: [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2016-04-05 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2016-04-05 |
Time |
12:25 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2016-04-05 |
Time |
12:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2016-03-21 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2016-03-21 |
Time |
16:16 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2016-03-21 |
Time |
16:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-04-18 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2016-04-18 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2016-03-30 |
Time |
09:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-03-24 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2016-03-24 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2016-03-16 |
Time |
17:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2016-04-05 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-04-04 |
Time |
17:13 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-04-04 |
Time |
17:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-03-21 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-03-21 |
Time |
15:23 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-03-21 |
Time |
15:23 |
Sent To |
|
|
Notes |
2016-03-21 15:28:53 | 1ST REVIEW: FBC 2014 MECHANICAL | | PERMIT #16030508 | | 3/21/16 | | | | 1) THE SUMMARY AC CALCULATIONS REQUIRE AN ENGINEERS | | SIGNATURE AND SEAL PER SECTION C403.2.1 FBC-14 ENERGY | | CONSERVATION. PLEASE CLARIFY WHY THERE IS NO | | VENTILATION AIR FOR OCCUPANTS SHOWN ON THE CALCS. | | 2) PROVIDE A DOOR SCHEDULE THAT INDICATES THE TYPE OF | | AND SIZE OF LOUVERED DOORS AT THE AC CLOSETS- REFER TO | | SECTION C403.2.7.2 FBC-14 ENERGY CONSERVATION. | | 3) THE CORRIDOR (HALLWAY 206) CANNOT SERVE AS A RETURN | | AIR DUCT FOR AHU-2- SEE SECTION 601.2 FBC-14 | | MECHANICAL. | | 4) THE AC SCHEDULE INDICATES A TOTAL OF 1600 CFM'S OF | | SUPPLY AIR FOR AHU-2, HOWEVER THE PLAN SHOWS A TOTAL OF | | 1795 CFM'S BEING DISTRIBUTED IN THE ZONE. | | 5) ALL NEW DUCT SMOKE DETECTORS SHALL BE INSTALLED IN | | THE RETURN AIR SYSTEMS OF THE AIR HANDLERS PER SECTION | | 606.2.1 FBC-14 MECHANICAL. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2016-04-06 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-04-06 |
Time |
15:01 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-04-06 |
Time |
13:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2016-03-24 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-03-24 |
Time |
13:04 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-03-23 |
Time |
15:14 |
Sent To |
|
|
Notes |
2016-03-24 13:26:32 | 1ST REVIEW: FBC 2014 | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | 1.SHOW DISTANCE T DRINKING FOUNTAIN TO COMPLY WITH FBC | | PL SEC. 403.5 | | | | 2. EXISTING PRINTS SHOW THE SPACE AS MIXED OCCUPANCY | | RESIDENTIAL AND BUSINESS NOW ITS JUST BUSINESS WHICH | | MAKES THIS A CHANGE OF OCCUPANCY PLEASE CLARIFY. | | PER WPB AMEND. TO FBC SEC 107.2.1 | | | | 3. SHOW COMPLIANCE FOR GRAB BARS TO COMPLY WITH FBC | | ACC. SEC 604.5.1-604.5.2 | | | | 4. PROVIDE RISER DIAGRAM FOR WOMENS BATHROOMS PER WPB | | AMEND TO FBC 107.3.5.1.3(13) | | | | 5. PROVIDE HOT WATER FOR LAVS TO COMPLY WITH FBC PL SEC | | 607.1 |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2016-04-18 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2016-04-18 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2016-04-18 |
Time |
11:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2016-04-14 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2016-04-14 |
Time |
13:41 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2016-04-14 |
Time |
13:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2016-03-24 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2016-03-24 |
Time |
14:36 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2016-03-24 |
Time |
14:36 |
Sent To |
|
|
Notes |
|
|