Plan Review Details - Permit 16030503
Plan Review Stops For Permit 16030503
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-06-07 Cont ID  
Sent By jwitmer Date 2016-06-07 Time 08:00 Rev Time 0.00
Received By jwitmer Date 2016-06-07 Time 07:51 Sent To  
Notes
2016-06-07 07:58:54BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16030503
 ADD: 1451 OLIVE AVE.
 CONT: GILBANE
 TEL: 561-236-7052
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: TUES. JUNE 07/2016
 ACTION: BUILDING PROVISO
  
 1) COMPLIED.
  
 2) COMPLIED.
  
 2A)COMPLIED.
  
 2B) COMPLIED.
  
 2D-F) PROVISO: 2010 FBC-B 1609.1.2 PROTECTION OF
 OPENINGS, 1609.6.4.4.1 COMPONENTS & CLADDING
  
 PROVISO: FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE
 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR
 CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)(A) EXTERIOR DOORS.
  
 PROVISO: 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED
 BY DCA RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN
 WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 3-4) COMPLIED.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-03-25 Cont ID  
Sent By jwitmer Date 2016-03-25 Time 09:35 Rev Time  
Received By jwitmer Date 2016-03-25 Time 07:15 Sent To  
Notes
2016-03-25 09:35:37BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16030503
 ADD: 1451 OLIVE AVE.
 CONT: GILBANE
 TEL: 561-236-7052
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: FRI. MARCH 25/2016
 ACTION: DENIED
  
 1) THE PERMIT APPLICATION INDICATES UNDER THE HEADING
 DESCRIPTION OF WORK: DEMOLITION OF A PORTION OF THE
 MUSEUM IN PREPARATION FOR EXPANSION. PLEASE INDICATE AS
 TO WHICH STAGE (SHEET 0003_D002_PHASING DIAGRAM) THIS
 SCOPE OF WORK THIS PERMIT PERTAINS TOO? IT APPEARS TO
 BE THE STAGE 4? 107.2.1.3. ADDITIONAL INFORMATION IS
 REQUIRED.
  
 2) SHEET 0004_LSD101 (LEVEL 1) INDICATES A TEMPORARY
 2ND EXIT FROM THE KING GALLERY ROOM A105.
 SHEET 0022_D351 SHOWS THE ROOMS A103 & B145 THE
 INFORMATION DESK AND INFORMATION ROOMS BEING DEMOLISHED
 AND SHEET 0004_LSD LEVEL 1 SHOWS A TEMPORARY 2 HR.
 WALL. THERE IS NO DOORWAY LEADING TO THE EXTERIOR.
 SHEET 0039_D801 DOES SHOW A EGRESS CORRIDOR AND EXIT
 PASSAGEWAY TO THE EXIT.
  
 2A) SHEET 0039_D801. THE PLANS DO NOT INDICATE HOW HIGH
 THE DECK IS ABOVE THE FLOOR LEVEL ? WHAT TYPE OF DECK
 DOES THIS FIRE RATED ASSEMBLY FASTEN TOO? IS IT A FIXED
 ASSEMBLY OR DOES IT HAVE A B DECK TYPE BOTTOM ASSEMBLY?
 PLEASE PROVIDE DETAILS? EXIT PASSAGEWAYS SHALL BE BUILT
 AS FIRE BARRIERS IN ACCORDANCE WITH 2014 FBC-B707.
  
 2B) SHEET 0039_D801. DETAIL #5 SHOWS A NEW EXTERIOR
 OPENING BUT THERE IS NO INFORMATION OF HOW THIS OPENING
 HAS BEEN CREATED, FILLED CELL BLOCK WITH REBAR, HEADER,
 LINTEL, WIND DESIGN, NO BUILDING CRITERIA PROVIDE?
 107.3.5.1.1. MINIMUM CRITERIA FOR COMMERCIAL PLAN
 REVIEW. PART OF THE MWFRS (MAIN WIND FORCE RESISTING
 SYSTEM).
  
 2D) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.4.1 COMPONENTS & CLADDING
  
 2E) FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3
 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR
 CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)(A) EXTERIOR DOORS.
  
 2F) 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA
 RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN WRITING BY
 THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
  
 3) SHEET 0004_LSD101. THIS SHEET INDICATES BRINGING IN
 PORTABLE RESTROOMS? WILL THEY BE USED ONSITE MORE THAN
 6 MONTHS. A SEPARATE PERMIT WILL BE REQUIRED, TIE
 DOWNS, ACCESSIBLE RAMP AND STAIRS, ACCESSIBLE
 RESTROOMS, HANDRAIL/ GUARDRAIL SYSTEMS AS WELL. 2014
 ADMIN. CODE 105.1.
  
 4) ON QUITE A FEW OF THE VARIOUS SHEETS THERE IS
 GRAVESITE PROTOCOL BUT NOT SUPPLIED IN THESE DOCUMENTS
 HOW TO PROTECT. 107.2.1.3 ADDITIONAL INFORMATION IS
 REQUIRED.
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-03-18 Cont ID  
Sent By vperez Date 2016-03-18 Time 14:40 Rev Time 0.00
Received By vperez Date 2016-03-18 Time 11:43 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2016-05-23 Cont ID  
Sent By pleduc Date 2016-05-24 Time   Rev Time 0.00
Received By pleduc Date 2016-05-23 Time 15:12 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2016-04-15 Cont ID  
Sent By pleduc Date 2016-04-15 Time   Rev Time 0.00
Received By pleduc Date 2016-04-15 Time 12:01 Sent To  
Notes
2016-04-15 16:31:57THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) SHEET LSD 101 - A DOOR IS INDICATED IN A CORRIDOR TO
 REDUCE A DEADEND. ADDING A DOOR DOES NOT ALWAYS RELIEVE
 THE REQUIREMNT. PLEASE PROVIDE THE LIFE SAFETY CODE
 REFERENCE AND THE DIMENSIONS OF THE ENTIRE CORRIDOR. IT
 IS NOT ALWAYS APPROPRAITE TO JUST ADD A DOOR. THE DOOR
 MAY BE ABLE TO BE REMOVED BY PROVIDING A TEMPOARAY WALL
 AT THE RESTROOM C171 DOOR.
  
 2) SHEET LSD 101 - REVERSE SWING DOOR OR REMOVE IS
 INDICATED AT THE DOUBLE DOORS AT ROOM C105. REMOVING
 THOSE DOOR MAY NOT BE AN OPTION AS IT MAY BE A REQUIRED
 RATED SEPARATION. PLEASE REVIEW AND ADDRESS.
  
 3) SHEET LSD 101 - PROVIDE FOR AN EXIT SIGN AT THE
 DOUBLE DOORS AT ROOM C105 AND ALL OTHER REVERSED SWING
 DOORS APPROPRIATE IN THE CORRECT DIRECTION.
  
 4) SHEET LSD 101 - ENSURE THAT ALL REVERSED SWING DOOR
 AR INSTALLED WITH THE PROPER AND APPROPRAITE EXIT
 HARDWARE DEVICES AS REQUIRED BY NFPA 101, CHAPTER 7,
 MEANS OF EGRESS. I.E PANIC HARDWARE, DOOR CLOSERS.
  
 5) SHEET LSD 101 - AT EXIT E IT IS INDICATED EXIT
 DISCHARGE PROVIDED DURING CONSTRUCTION. PLEASE PROVIDE
 DETAIL OR AN EXPLANATION NOTE AS TO HOW IT IT WILL BE
 PROVIDED.
  
 6) SHEET D 0001 - ADD A NOTE FOR FIRE ALARM AND FIRE
 SPRINKLER REMAINING ACTIVE THAT INDICATES "ANY TIME
 THAT WORK ON THE LIFE SAFETY SYSTEM, EXCEEDS 4 HOURS, A
 FIRE WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL
 FULL AND COMPLETE PROTECTION IS RETURNED".
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-06-07 Cont ID  
Sent By cpuell Date 2016-06-07 Time 12:32 Rev Time 0.00
Received By cpuell Date 2016-05-12 Time 09:09 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-04-22 Cont ID  
Sent By cpuell Date 2016-04-22 Time 10:33 Rev Time 0.00
Received By cpuell Date 2016-03-11 Time 07:57 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2016-03-22 Cont ID  
Sent By hmoser Date 2016-03-22 Time 11:13 Rev Time 0.00
Received By hmoser Date 2016-03-22 Time 09:26 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-03-27 Cont ID  
Sent By tklarge Date 2016-03-27 Time 07:35 Rev Time 0.00
Received By tklarge Date 2016-03-27 Time 06:31 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2016-08-01 Cont ID  
Sent By skennedy Date 2016-08-01 Time 15:15 Rev Time 0.00
Received By skennedy Date 2016-07-20 Time 12:57 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2016-06-07 Cont ID  
Sent By jroach Date 2016-06-07 Time 11:53 Rev Time 0.00
Received By jroach Date 2016-06-07 Time 11:53 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2016-04-22 Cont ID  
Sent By jroach Date 2016-04-22 Time 10:05 Rev Time 0.00
Received By jroach Date 2016-04-22 Time 10:05 Sent To  
Notes
2016-04-22 10:07:58NO OBJECTIONS TO THE PROPOSED DEMOLITION. CITY STAFF IS
 MEETING WITH THE NORTON REPRESENTATIVES ON MAY 12, 2016
 TO FINALIZE STEPS AND PROCEDURES FOR PROCEEDING WITH
 DEMOLITIONS ON THE SITE AND PROTOCOL FOR HANDLING THE
 SENSITIVE NATURE OF THE PROPERTY. THIS REVIEW WILL
 "PASSED" ONCE ALL PARTIES ARE SATISFIED WITH THE
 ESTABLISHED PROTOCOL.
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 F: 561.822.1460
  
 E: [email protected]
  
 W: WPB.ORG
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved