Plan Review Details - Permit 16030393
Plan Review Stops For Permit 16030393 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2016-03-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-03-14 |
Time |
|
Rev Time |
|
Received By |
jwitmer |
Date |
2016-03-14 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2016-03-14 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-03-14 |
Time |
11:52 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-03-14 |
Time |
11:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2016-03-14 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2016-03-14 |
Time |
12:04 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2016-03-14 |
Time |
11:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-04-14 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-04-14 |
Time |
08:49 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-04-13 |
Time |
11:39 |
Sent To |
|
|
Notes |
2016-04-13 11:40:48 | RESUB ROUTED TO CCOLE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-03-26 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-03-26 |
Time |
04:30 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-03-09 |
Time |
14:35 |
Sent To |
|
|
Notes |
2016-03-14 11:52:53 | 3/14 TO B26 | 2016-03-09 14:35:33 | B26 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2016-03-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-03-14 |
Time |
09:33 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-03-14 |
Time |
09:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2016-04-14 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-04-14 |
Time |
08:48 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-04-14 |
Time |
08:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-03-17 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-03-17 |
Time |
06:59 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-03-17 |
Time |
06:59 |
Sent To |
|
|
Notes |
2016-03-17 07:05:38 | 1ST REVIEW: FBC 2014 MECHANICAL, EXISTING BUILDING, | | ENERGY CONSERVATION | | PERMIT #16030393 | | 3/17/16 | | | | 1) REFER TO SECTION 809.2 FBC-14 EXISTING BUILDING AND | | PROVIDE MINIMUM VENTILATION CALCULATIONS PER TABLE | | 403.3 FBC-14 MECHANICAL. | | 2) INDICATE THE SIZE OF THE O/A DUCTS AND PROVIDE | | MOTORIZED DAMPERS AT EACH AIR HANDLER LOCATION- SECTION | | C403.2.4.4 FBC-14 ENERGY CONSERVATION. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2016-03-26 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-03-26 |
Time |
04:30 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-03-26 |
Time |
04:25 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy